Semi-micro-HPLC using a column-switching technique was developed for simultaneous determination of vitamin A and E contents in infant formula. Vitamin A and E were extracted by PDA - HPLC with reversed phase column using organic solvent and their contents in Certified Reference Material (CRM) and infant formula were determined and compared with hydrolysis method and rapid extraction. Developed method has many advantages of simple and rapid sample preparation and simultaneous determination of vitamin A and E by micro-HPLC using reversed phase column.
This study was carried out to develop an accurate and rapid analysis method to measure the contents of iodide and chloride in infant formula using an ion selectivity electrode. The infant formula SRM 1846 (Standard Reference Material 1846, NIST, USA) was used as a CRM (Certified reference material). Samples were dissolved in water with 3% acetic acid and filtered through filter paper and adjusted to pH 7.0 with 0.1N NaOH. At pH 7.0, the iodide content of the CRM was $1.04{\pm}0.03\;mg/kg$ compared to the specification of $1.11{\pm}0.1\;mg/kg$ of CRM, and the recovery was $93.7{\pm}2.7%$. The chloride content was $5114.3{\pm}240\;mg/kg$ compared to the specification of $4,920{\pm}300mg/kg$ of CRM, and the recovery was $103.9{\pm}4.9%$. Ion selectivity electrodes could be successful1y used to determine the concentration of iodide and chloride ions in infant formula by a simple and rapid pretreatment of sample matrixes.
Kim, Yong-Doo;Bae, Hyun-Kil;Kim, Dalho;Oh, Sang-Hyub;Lee, Jin Hong;Lee, Sangil
Journal of the Korean Institute of Gas
/
v.22
no.2
/
pp.46-51
/
2018
Hydrogen sulfide from landfill and sewage treatment plant is a major odor component and causes many civil petitions. Rapidly developing industries release hydrogen sulfide, an odorous gas, to the atmosphere. This study aims to develop a $10{\mu}mol/mol$ concentration level hydrogen sulfide primary standard gas for odor measurement. The hydrogen sulfide gas was prepared at a nominal concentration of $10{\mu}mol/mol$ in nitrogen using the gravimetric method described in ISO 6142. Replicate standard gases were produced in 4 aluminium cylinders, and their concentrations were verified by GC-AED. The uncertainty of production was less than 0.50 %, and the variation of the 4 replicates was 0.22 %. The wall adsorption of hydrogen sulfide in cylinders was 0.10 % at 1500 psi, and the concentration was estimated to be long-term stable for one year. The relative expanded uncertainty of the preparation consistency, adsorption and long-term stability of this hydrogen sulfide standard gas was less than 1.05 % (95 % of confidence level, k=2).
A technique for the determination of trace Cu(II) in various real samples by FAAS after the column preconcentration onto p-dichlorobenzene-SA adsorbent, which is microcrystalline p-dichlorobenzene loaded with salicylaldoxime (SA) has been developed. Several experimental conditions such as pH of the sample solution, the amount of chelating agent salicylaldoxime, the amount of adsorbent p-dichlorobenzene-SA, and flow rate of sample solution were optimized. The interfering effects of various concomitant ions were investigated. $CN^-$ interfered more seriously than any other ions. However, the interference by $1\;{\mu}g\;mL^{-1}\;CN^-$ could be overcome completely by controlling the concentration of Ni(II) to $20\;{\mu}g\;mL^{-1}$. The linear range, correlation coefficient ($R^2$) and detection limit obtained by this technique were $3.0\sim100\;ng\;mL^{-1}$, 0.9901, and $3.1\;ng\;mL^{-1}$, respectively. For validating this technique, the aqueous samples (wastewater, reservoir water and stream water) and the food samples (orange juice, fresh egg and skim milk) were used. Recovery yields of 93~104% were obtained. These measured mean values were not differents from ICP-MS data at 95% confidence level. The good results were obtained from the experiments using the rice flour certified reference material (CRM) sample. Based on the experimental results, it was found that this technique could be applied to the preconcentration and determination of Cu(II) for various real samples.
In general, quantitative chemical analysis in various areas including food, the environment, in vitro diagnostics, etc., requires traceability in order to increase the reliability of the measurements. Measurement traceability is a property of an unbroken chain of comparisons relating an instrument's measurements to SI units. Purity analysis is the first process for establishing traceability to SI units in chemical measurements. The purpose of this study is to develop and validate a method of purity assignment for establishing the traceability of $17{\beta}$-estradiol measurements in an in vitro diagnostics field. The establishment of this method is very important as it can be applied to the development of CRM and to the analysis of the purity of other hormones. The method of assignment of the purity of $17{\beta}$-estradiol was developed using the mass balance method and was validated through participation in an International comparison. In the mass balance method, impurities are categorized into four classes as follows: total related structure impurities, water, residual organic solvents, and nonvolatiles/inorganics. In this study, total related structure impurities were characterized by a gas chromatography-flame ionization detector (GC-FID) and a high-performance liquid chromatography-ultraviolet (HPLC-UV) detector, water content was determined by a Karl-Fisher coulometer, and total residual solvents and nonvolatiles/inorganics were checked simultaneously by thermogravimetric analysis (TGA). The purity of the $17{\beta}$-estradiol was 985.6 mg/g and the expanded uncertainty was 2.1 mg/g at 95% confidence. The developed method can be applied to the development of certified reference materials, which play a critical role in traceability.
Park, Ji-Young;Lim, Jong-Myoung;Ji, Young-Yong;Lim, Chung-Sup;Jang, Byung-Uck;Chung, Kun Ho;Lee, Wanno;Kang, Mun-Ja
Journal of Radiation Protection and Research
/
v.41
no.4
/
pp.359-367
/
2016
Background: As new legislation has come into force implementing radiation safety management for the use of naturally occurring radioactive materials (NORM), it is necessary to establish a rapid and accurate measurement technique. Measurement of $^{238}U$ and $^{232}Th$ using conventional methods encounter the most significant difficulties for pretreatment (e.g., purification, speciation, and dilution/enrichment) or require time-consuming processes. Therefore, in this study, the applicability of ED-XRF as a non-destructive and rapid screening method was validated for raw materials and by-product samples. Materials and Methods: A series of experiments was conducted to test the applicability for rapid screening of XRF measurement to determine activity of $^{238}U$ and $^{232}Th$ based on certified reference materials (e.g., soil, rock, phosphorus rock, bauxite, zircon, and coal ash) and NORM samples commercially used in Korea. Statistical methods were used to compare the analytical results of ED-XRF to those of certified values of certified reference materials (CRM) and inductively coupled plasma mass spectrometry (ICP-MS). Results and Discussion: Results of the XRF measurement for $^{238}U$ and $^{232}Th$ showed under 20% relative error and standard deviation. The results of the U-test were statistically significant except for the case of U in coal fly ash samples. In addition, analytical results of $^{238}U$ and $^{232}Th$ in the raw material and by-product samples using XRF and the analytical results of those using ICP-MS ($R^2{\geq}0.95$) were consistent with each other. Thus, the analytical results rapidly derived using ED-XRF were fairly reliable. Conclusion: Based on the validation results, it can be concluded that the ED-XRF analysis may be applied to rapid screening of radioactivities ($^{238}U$ and $^{232}Th$) in NORM samples.
A method based on flow injection-isotope dilution-cold vapor-inductively coupled plasma mass spectrometry (FI-IDCV-ICP/MS) has been applied to determine trace level of mercury in fly ash. $^{200}Hg$ isotopic spike was added to 0.25 g of BCR176R fly ash and then decomposed by microwave digestion procedure with acid mixture A (8 mL $HNO_3$ + 2 mL HCl + 2 mL HF) and acid mixture B (8 mL $HNO_3$ + 2 mL $HClO_4$ + 2 mL HF) for applying IDMS. Mercury cold vapor was generated by using reductant solution of 0.2% (w/w) $NaBH_4$ and 0.05% (w/w) NaOH. The measurements of n($^{200}Hg$)/n($^{202}Hg$) isotope ratio was made using a quadrupole ICP/MS system. The accuracy in this method was verified by the analysis of certified reference material (CRM) of fly ash (BCR 176R). The indicative value of Hg in BCR 176R fly ash was $1.60{\pm}0.23$ mg/kg (k = 2). The determined values of Hg in BCR 176R fly ash by the method of FI-CV-ID-ICP/MS described in this paper were $1.60{\pm}0.24$ mg/kg (k = 3.18) and the analysis results were in well agreement with the indicative value within the range of uncertainty.
The analytical method of trace toxic metals in livestock products was confirmed and validated through certified reference material (CRM) and the international proficiency tests. There are some difficulties to determine low levels of toxic metals in livestock products because of interferences due to the matrix. The recoveries of CRM (NIST 1577c) ranged from 73.9 to 119% for lead and from 86.4 to 111% for cadmium in bovine liver. The international proficiency tests were carried out with the milk powder and cocoa powder samples including metals provided by Food Analysis Performance Assessment Scheme (FAPAS$^{(R)}$, UK). The test samples were prepared by microwave digestion using solution of $HNO_3:H_2O_2:H_2O$ (v/v/v = 5 : 2 : 4) and analyzed by ICP/MS. The analytical result of cadmium in milk powder was $121{\mu}g/kg$ with -0.3 of the z-score compared to the assigned value of $131{\mu}g/kg$ by FAPAS$^{(R)}$. The analytical results of lead and cadmium in cocoa powder were $29.2{\mu}g/kg$ and $97.6{\mu}g/kg$, respectively, which satisfied the assigned values of $34.2{\mu}g/kg$ for lead and $126{\mu}g/kg$ for cadmium by FAPAS$^{(R)}$. It is verified that the analytical method is accurate and reliable to determine trace lead and cadmium in livestock products by microwave digestion and ICP/MS.
In this study, the contents of ${\beta}$-carotene and cholesterol were evaluated in various types of agricultural and processed foods (vegetables, legume products, dairy products, and eggs). Certified reference material (CRM) with an assigned value was used for the validation of the ${\beta}$-carotene and cholesterol analytical methods. High recoveries (accuracy) of ${\beta}$-carotene (96%) and cholesterol (97%) were obtained from the quantitative analysis of the CRM, with a relative standard deviation (%) of 1.86 and 3.35% for the ${\beta}$-carotene and cholesterol, respectively. Vegetables contained relatively high concentrations of ${\beta}$-carotene (raw Toona sinensis, $1650.97{\mu}g/100g$, a raw small onion, $879.09{\mu}g/100g$, and a raw lettuce stem, $591.89{\mu}g/100g$). The ${\beta}$-carotene values in dried chickpeas ($22.94{\mu}g/100g$) and dried brown lentils ($21.98{\mu}g/100g$) were similar. The highest ${\beta}$-carotene value among the analyzed dairy products was found in banana milk ($234.21{\mu}g/100g$) while other flavored products (strawberry milk and chocolate milk) did not contain any ${\beta}$-carotene. Furthermore, ${\beta}$-carotene was not detected in goat milk and high calcium milk in this study. With regard to cholesterol among the analyzed samples, the highest cholesterol value was found in egg yolk (629.30 mg/100 g), and cooking methods (boiling and frying) had little effect on the cholesterol levels of eggs. In addition, the cholesterol content in vanilla ice cream was 28.77 mg/100 g which was the highest value among the analyzed dairy products.
Mass spectrometric analysis was carried out using multicollector inductively coupled plasma mass spectrometry (MC-ICP-MS) for the precise and accurate determination of the isotope ratios of ultratrace levels of uranium dissolved in 3% $HNO_3$. We used the certified reference material (CRM) 112-A at a trace level of 100 pg/mL for the uranium isotopic measurement. Multiple collectors were utilized for the simultaneous measurement of uranium isotopes to reduce the signal uncertainty due to variations in the ion beam intensity over time. Mass bias correction was applied to the measured U isotopes to improve the precision and accuracy. Furthermore, elemental standard solution with certified values of platinum, iridium, gold, and thallium dissolved in 3% $HNO_3$ were analyzed to investigate the formation rates of the polyatomic ions of $Ir^{40}$$Ar^+$, $Pt^{40}$$Ar^+$, $Tl^{40}$$Ar^+$, $Au^{40}$$Ar^+$ for the concentration range of 50-400 pg/mL. Those polyatomic ions have mass-to-charge ratios in the 230-245 m/z region that it would contribute to the increase of background intensity of uranium, thorium, plutonium, and americium isotopes. The effect of the polyatomic ion interference on uranium isotope measurement has been estimated.
본 웹사이트에 게시된 이메일 주소가 전자우편 수집 프로그램이나
그 밖의 기술적 장치를 이용하여 무단으로 수집되는 것을 거부하며,
이를 위반시 정보통신망법에 의해 형사 처벌됨을 유념하시기 바랍니다.
[게시일 2004년 10월 1일]
이용약관
제 1 장 총칙
제 1 조 (목적)
이 이용약관은 KoreaScience 홈페이지(이하 “당 사이트”)에서 제공하는 인터넷 서비스(이하 '서비스')의 가입조건 및 이용에 관한 제반 사항과 기타 필요한 사항을 구체적으로 규정함을 목적으로 합니다.
제 2 조 (용어의 정의)
① "이용자"라 함은 당 사이트에 접속하여 이 약관에 따라 당 사이트가 제공하는 서비스를 받는 회원 및 비회원을
말합니다.
② "회원"이라 함은 서비스를 이용하기 위하여 당 사이트에 개인정보를 제공하여 아이디(ID)와 비밀번호를 부여
받은 자를 말합니다.
③ "회원 아이디(ID)"라 함은 회원의 식별 및 서비스 이용을 위하여 자신이 선정한 문자 및 숫자의 조합을
말합니다.
④ "비밀번호(패스워드)"라 함은 회원이 자신의 비밀보호를 위하여 선정한 문자 및 숫자의 조합을 말합니다.
제 3 조 (이용약관의 효력 및 변경)
① 이 약관은 당 사이트에 게시하거나 기타의 방법으로 회원에게 공지함으로써 효력이 발생합니다.
② 당 사이트는 이 약관을 개정할 경우에 적용일자 및 개정사유를 명시하여 현행 약관과 함께 당 사이트의
초기화면에 그 적용일자 7일 이전부터 적용일자 전일까지 공지합니다. 다만, 회원에게 불리하게 약관내용을
변경하는 경우에는 최소한 30일 이상의 사전 유예기간을 두고 공지합니다. 이 경우 당 사이트는 개정 전
내용과 개정 후 내용을 명확하게 비교하여 이용자가 알기 쉽도록 표시합니다.
제 4 조(약관 외 준칙)
① 이 약관은 당 사이트가 제공하는 서비스에 관한 이용안내와 함께 적용됩니다.
② 이 약관에 명시되지 아니한 사항은 관계법령의 규정이 적용됩니다.
제 2 장 이용계약의 체결
제 5 조 (이용계약의 성립 등)
① 이용계약은 이용고객이 당 사이트가 정한 약관에 「동의합니다」를 선택하고, 당 사이트가 정한
온라인신청양식을 작성하여 서비스 이용을 신청한 후, 당 사이트가 이를 승낙함으로써 성립합니다.
② 제1항의 승낙은 당 사이트가 제공하는 과학기술정보검색, 맞춤정보, 서지정보 등 다른 서비스의 이용승낙을
포함합니다.
제 6 조 (회원가입)
서비스를 이용하고자 하는 고객은 당 사이트에서 정한 회원가입양식에 개인정보를 기재하여 가입을 하여야 합니다.
제 7 조 (개인정보의 보호 및 사용)
당 사이트는 관계법령이 정하는 바에 따라 회원 등록정보를 포함한 회원의 개인정보를 보호하기 위해 노력합니다. 회원 개인정보의 보호 및 사용에 대해서는 관련법령 및 당 사이트의 개인정보 보호정책이 적용됩니다.
제 8 조 (이용 신청의 승낙과 제한)
① 당 사이트는 제6조의 규정에 의한 이용신청고객에 대하여 서비스 이용을 승낙합니다.
② 당 사이트는 아래사항에 해당하는 경우에 대해서 승낙하지 아니 합니다.
- 이용계약 신청서의 내용을 허위로 기재한 경우
- 기타 규정한 제반사항을 위반하며 신청하는 경우
제 9 조 (회원 ID 부여 및 변경 등)
① 당 사이트는 이용고객에 대하여 약관에 정하는 바에 따라 자신이 선정한 회원 ID를 부여합니다.
② 회원 ID는 원칙적으로 변경이 불가하며 부득이한 사유로 인하여 변경 하고자 하는 경우에는 해당 ID를
해지하고 재가입해야 합니다.
③ 기타 회원 개인정보 관리 및 변경 등에 관한 사항은 서비스별 안내에 정하는 바에 의합니다.
제 3 장 계약 당사자의 의무
제 10 조 (KISTI의 의무)
① 당 사이트는 이용고객이 희망한 서비스 제공 개시일에 특별한 사정이 없는 한 서비스를 이용할 수 있도록
하여야 합니다.
② 당 사이트는 개인정보 보호를 위해 보안시스템을 구축하며 개인정보 보호정책을 공시하고 준수합니다.
③ 당 사이트는 회원으로부터 제기되는 의견이나 불만이 정당하다고 객관적으로 인정될 경우에는 적절한 절차를
거쳐 즉시 처리하여야 합니다. 다만, 즉시 처리가 곤란한 경우는 회원에게 그 사유와 처리일정을 통보하여야
합니다.
제 11 조 (회원의 의무)
① 이용자는 회원가입 신청 또는 회원정보 변경 시 실명으로 모든 사항을 사실에 근거하여 작성하여야 하며,
허위 또는 타인의 정보를 등록할 경우 일체의 권리를 주장할 수 없습니다.
② 당 사이트가 관계법령 및 개인정보 보호정책에 의거하여 그 책임을 지는 경우를 제외하고 회원에게 부여된
ID의 비밀번호 관리소홀, 부정사용에 의하여 발생하는 모든 결과에 대한 책임은 회원에게 있습니다.
③ 회원은 당 사이트 및 제 3자의 지적 재산권을 침해해서는 안 됩니다.
제 4 장 서비스의 이용
제 12 조 (서비스 이용 시간)
① 서비스 이용은 당 사이트의 업무상 또는 기술상 특별한 지장이 없는 한 연중무휴, 1일 24시간 운영을
원칙으로 합니다. 단, 당 사이트는 시스템 정기점검, 증설 및 교체를 위해 당 사이트가 정한 날이나 시간에
서비스를 일시 중단할 수 있으며, 예정되어 있는 작업으로 인한 서비스 일시중단은 당 사이트 홈페이지를
통해 사전에 공지합니다.
② 당 사이트는 서비스를 특정범위로 분할하여 각 범위별로 이용가능시간을 별도로 지정할 수 있습니다. 다만
이 경우 그 내용을 공지합니다.
제 13 조 (홈페이지 저작권)
① NDSL에서 제공하는 모든 저작물의 저작권은 원저작자에게 있으며, KISTI는 복제/배포/전송권을 확보하고
있습니다.
② NDSL에서 제공하는 콘텐츠를 상업적 및 기타 영리목적으로 복제/배포/전송할 경우 사전에 KISTI의 허락을
받아야 합니다.
③ NDSL에서 제공하는 콘텐츠를 보도, 비평, 교육, 연구 등을 위하여 정당한 범위 안에서 공정한 관행에
합치되게 인용할 수 있습니다.
④ NDSL에서 제공하는 콘텐츠를 무단 복제, 전송, 배포 기타 저작권법에 위반되는 방법으로 이용할 경우
저작권법 제136조에 따라 5년 이하의 징역 또는 5천만 원 이하의 벌금에 처해질 수 있습니다.
제 14 조 (유료서비스)
① 당 사이트 및 협력기관이 정한 유료서비스(원문복사 등)는 별도로 정해진 바에 따르며, 변경사항은 시행 전에
당 사이트 홈페이지를 통하여 회원에게 공지합니다.
② 유료서비스를 이용하려는 회원은 정해진 요금체계에 따라 요금을 납부해야 합니다.
제 5 장 계약 해지 및 이용 제한
제 15 조 (계약 해지)
회원이 이용계약을 해지하고자 하는 때에는 [가입해지] 메뉴를 이용해 직접 해지해야 합니다.
제 16 조 (서비스 이용제한)
① 당 사이트는 회원이 서비스 이용내용에 있어서 본 약관 제 11조 내용을 위반하거나, 다음 각 호에 해당하는
경우 서비스 이용을 제한할 수 있습니다.
- 2년 이상 서비스를 이용한 적이 없는 경우
- 기타 정상적인 서비스 운영에 방해가 될 경우
② 상기 이용제한 규정에 따라 서비스를 이용하는 회원에게 서비스 이용에 대하여 별도 공지 없이 서비스 이용의
일시정지, 이용계약 해지 할 수 있습니다.
제 17 조 (전자우편주소 수집 금지)
회원은 전자우편주소 추출기 등을 이용하여 전자우편주소를 수집 또는 제3자에게 제공할 수 없습니다.
제 6 장 손해배상 및 기타사항
제 18 조 (손해배상)
당 사이트는 무료로 제공되는 서비스와 관련하여 회원에게 어떠한 손해가 발생하더라도 당 사이트가 고의 또는 과실로 인한 손해발생을 제외하고는 이에 대하여 책임을 부담하지 아니합니다.
제 19 조 (관할 법원)
서비스 이용으로 발생한 분쟁에 대해 소송이 제기되는 경우 민사 소송법상의 관할 법원에 제기합니다.
[부 칙]
1. (시행일) 이 약관은 2016년 9월 5일부터 적용되며, 종전 약관은 본 약관으로 대체되며, 개정된 약관의 적용일 이전 가입자도 개정된 약관의 적용을 받습니다.