• 제목/요약/키워드: Ceramic crown

검색결과 229건 처리시간 0.018초

Ceramic molar crown reproducibility by digital workflow manufacturing: An in vitro study

  • Jeong, II-Do;Kim, Woong-Chul;Park, Jinyoung;Kim, Chong-Myeong;Kim, Ji-Hwan
    • The Journal of Advanced Prosthodontics
    • /
    • 제9권4호
    • /
    • pp.252-256
    • /
    • 2017
  • PURPOSE. This in vitro study aimed to analyze and compare the reproducibility of zirconia and lithium disilicate crowns manufactured by digital workflow. MATERIALS AND METHODS. A typodont model with a prepped upper first molar was set in a phantom head, and a digital impression was obtained with a video intraoral scanner (CEREC Omnicam; Sirona GmbH), from which a single crown was designed and manufactured with CAD/CAM into a zirconia crown and lithium disilicate crown (n=12). Reproducibility of each crown was quantitatively retrieved by superimposing the digitized data of the crown in 3D inspection software, and differences were graphically mapped in color. Areas with large differences were analyzed with digital microscopy. Mean quadratic deviations (RMS) quantitatively obtained from each ceramic group were statistically analyzed with Student's t-test (${\alpha}=.05$). RESULTS. The RMS value of lithium disilicate crown was $29.2\;(4.1){\mu}m$ and $17.6\;(5.5){\mu}m$ on the outer and inner surfaces, respectively, whereas these values were $18.6\;(2.0){\mu}m$ and $20.6\;(5.1){\mu}m$ for the zirconia crown. Reproducibility of zirconia and lithium disilicate crowns had a statistically significant difference only on the outer surface (P<.001). The outer surface of lithium disilicate crown showed over-contouring on the buccal surface and under-contouring on the inner occlusal surface. The outer surface of zirconia crown showed both over- and under-contouring on the buccal surface, and the inner surface showed under-contouring in the marginal areas. CONCLUSION. Restoration manufacturing by digital workflow will enhance the reproducibility of zirconia single crowns more than that of lithium disilicate single crowns.

코발트-크롬 합금으로 제작된 금속-도재관의 적합도 평가 (Evaluation of fitness of metal-ceramic crown fabricated by cobalt-chrome alloy)

  • 김재홍;김원수;김기백
    • 한국치위생학회지
    • /
    • 제13권2호
    • /
    • pp.361-368
    • /
    • 2013
  • Objectives : The purpose of this in vitro study was to evaluate the effect of firing cycles on the marginal and internal fit of metal ceramic crown. Methods : Ten same cases of stone models (abutment teeth 11) were manufactured. Ten cobalt-chrome cores were made per each models and the marginal and internal fit was evaluated through a silicone replica technique. The marginal and internal fit of specimens was measured twice. The first measurement was done after manufacturing cobalt-chrome alloy core and the second measurement was done after porcelain firing. T-test of paired sample for statistical analysis was executed with SPSS 12.0K for Windows (${\alpha}$=0.05). Results : Mean(SD) marginal and internal fit were 77.1(23.3) ${\mu}m$ for the cobalt-chrome alloy core group and 84.4(21.9) ${\mu}m$ for the metal-ceramic crown group. They were statistically significant differences between groups for marginal and internal fit (p<.05). Conclusions : All metal ceramic crowns showed marginal and internal fit ranged within the current clinical recommendations.

열가압성형도재의 사용이 금속도재관 치경부 변연적합도에 미치는 영향 (The effect of heat and press-on-metal technique on marginal fit of metal-ceramic crown)

  • 김지은;김세연;이청희
    • 대한치과보철학회지
    • /
    • 제52권2호
    • /
    • pp.90-96
    • /
    • 2014
  • 연구 목적: 이 연구의 목적은 열가압성형기법이 금속도재관의 치경부 변연적합도에 미치는 영향을 확인하는 것이다. 연구 재료 및 방법: 실험에 앞서, 4개의 금속 주모형을 형성하였다. 각 모형은 각각chamfer, heavy chamfer, shoulder with bevel, shoulder (collarless)변연을 형성하였다. 각 변연당 10개씩의 금관을 제작하여, 총 40개를 제작하였다. Coping 단계에서, 그리고 금속도재관 완성 단계에서 주모형과 금관 사이의 변연간극은 100배율의 광학현미경 관찰을 통하여 측정되었다. Data분석은 paired t-test along with one-way ANOVA와 Duncan multiple comparison test를 이용하여 이루어졌다. 결과: 변연간극의 평균과 표준편차를 분석한 결과, 금속 코핑과 그 후 완성된 금속도재관, 모든 경우에서 변연부 간격은 임상적 허용범위 안에 있었다. Chamfer 변연 실험군의 경우 Heavy chamfer 변연 실험군에 비하여 금속도재관 완성 후 변연부 간격의 유의한 증가가 있었다. 그리고Shoulder 변연 실험군에서 도재로 처리된 변연이 Chamfer와 Shoulder변연 실험군의 금속변연에 비하여 변연부 간격이 유의하게 작게 나타났다. 결론: 열가압성형기법을 통하여 제작한 금속도재수복물의 변연적합도는 전통적인 방법으로 제작한 금속도재수복물의 변연적합도와 유의한 차이점이 없었다. 제작과정의 효율성으로, 열가압성형기법은 임상에서의 효과적인 사용법으로 고려될 수 있다.

도재전장주조관의 순측 치경부 변연 적합도에 관한 주사전자현미경적 연구 (FITNESS OF THE COLLARLESS METAL-CERAMIC RESTORATIONS AT LABIAL MARGINS: A SCANNING ELECTRON MICROSCOPE STUDY)

  • 김영한;이선형
    • 대한치과보철학회지
    • /
    • 제23권1호
    • /
    • pp.113-123
    • /
    • 1985
  • The purpose of this study was to evaluate the marginal fitness of collarless metal-ceramic crown formed with direct lift technique using wax compared with metal-ceramic crown with metal butt margin. Twenty crowns, ten were collarless metal-ceramic crowns and ten were metal-ceramic crowns with metal butt margins, were made and cemented on epoxy resin dies, and their marginal openings were measured on scanning electron microphotographic prints at x200 magnification. The results were as follows; 1. In the case of collarless metal-ceramic crowns, the mean marginal opeining was $43.78{\pm}17.67{\mu}m$, the mean maximum marginal opening was $52.81{\pm}19.81{\mu}m$, and the mean minimum marginal opening was $34.99{\pm}16.58{\mu}m$. 2. In the case of metal-ceramic crowns with metal butt margins, the mean marginal opening was $47.62{\pm}25.55{\mu}m$, the mean maximum marginal opening was $61.90{\pm}24.39{\mu}m$, and the mean minimum marginal opening was $34.86{\pm}24.92{\mu}m$. 3. There was no significant difference between two types of crowns at the 99% confidence level. 4. The marginal fitness of collarless metal-ceramic crown formed with direct lift technique using wax was clinically acceptable.

  • PDF

금속코핑 설계에 따른 Collarless Metal Ceramic Crown의 파절강도에 관한 연구 (A STUDY ON FRACTURE STRENGTH OF COLLARLESS METAL CERAMIC CROWN WITH DIFFERENT METAL COPING DESIGN)

  • 윤종욱;양재호;장익태;이선형;정헌영
    • 대한치과보철학회지
    • /
    • 제37권4호
    • /
    • pp.454-464
    • /
    • 1999
  • The metal ceramic crown is currently the most popular complete veneer restoration in dentistry, but in many cases, the metal cervical collar at the facial margin is unesthetic and unacceptable. Facial porcelain margin has been used in place of it. But this dose not solve the problems, such as dark gingival discoloration and cervical opaque reflection of porcelain veneer. Recently, metal copings which were designed to terminate its labio-cervical end on the axial walls coronal to the shoulder have been clinically used to solve the esthetic problem of metal ceramic crown. But in this design, porcelain veneer of labio-cervical area which is not supported by metal may not be able to resist the stress during cementation and mastication. The purpose of this study was to evaluate fracture strength and fractured appearance of crowns according to different coping designs. A resin maxillary left central incisor analogue was prepared for a metal ceramic crown, and metal dies were made with duplication mold. Metal copings were made and assigned to one of four groups based on facial framework designs: group 1, coping with 0.5mm metal collar; group 2, metal extended to the shoulder; group 3, metal extended to 1mm coronal tn the shoulder: group 4, metal extended to 2mm coronal to the shoulder. Copings and crowns were adjusted to be same size and thickness, and cemented to metal dies with zinc phosphate cement by finger pressure. Fracture strength was measured with Instron Universal Testing Machine. Metal dies were anchored in Three-way-vice at 3mm below finish line and at $130^{\circ}$ inclined to the long axis of the crown. Load was directed lingually at 2mm below midincisal edge. Load value at initial crack and at catastrophic fracture was recorded. The results obtained were as follows : 1. Fracture strength values at initial crack were higher in groups 1, 2 than in groups 3, 4 but this difference was not statistically significant(P<0.05). 2. Conventional metal collared crown had greater catastrophic fracture strength than any other collarless crowns. 3. The greater the labial metal coping reduction, the lower the catastrophic fracture strength of crowns but when more than 1mm of labial metal reduction was done, the difference in strengths was not statistically significant(p<0.05). 4. The strongest collarless coping design was group 2.

  • PDF

도재용 코발트-크롬 금속관의 변연적합도 비교 (Comparison of the Marginal Fitness of Ceramic Co-Cr Metal Crown)

  • 전병욱;김부섭
    • 대한치과기공학회지
    • /
    • 제37권2호
    • /
    • pp.69-76
    • /
    • 2015
  • Purpose: In this study, the marginal fitness of ceramic Co-Cr metal crown made by precision casting, milling, and selective laser melting method were compared. Methods: The ceramic Co-Cr metal crown manufactured by precision casting used the lost wax(LC specimen) method. The abutment were scanned and then made by milling(CM specimen), selective laser melting(CS specimen) method. The specimen were cut bucco-lingual and mesio-distal, and absolute marginal discrepancy and marginal gap were measured using a digital microscope. The surface roughness of the crown was also observed. Results: On the bucco-lingual axial, absolute marginal discrepancy was the LC specimen $31.72({\pm}4.58){\mu}m$, the CM specimen $78.29({\pm}3.28){\mu}m$ and the CS specimen $143.13({\pm}3.83){\mu}m$, respectively. On the bucco-lingual axial, marginal gap was the LC specimen $22.70({\pm}1.46){\mu}m$, the CM specimen $22.70({\pm}1.49){\mu}m$ and CS specimen $99.60({\pm}1.57){\mu}m$, respectively. Conclusion: For ceramic Co-Cr metal crowns, LC specimen was superior for absolute marginal discrepancy and marginal gap. The surface of metal crowns by selective laser melting were the roughest.

MARGINAL FIT OF THE DIGIDENT CAD/CAM ZIRCONIA CERAMIC CROWNS

  • Kim Yong-Sun;Yang Jae-Ho
    • 대한치과보철학회지
    • /
    • 제44권3호
    • /
    • pp.275-283
    • /
    • 2006
  • Statement of problem. There have been many studies about marginal discrepancy of single restorations made by various systems and materials. However most of the statistical inferences are not definite because of sample size, measurement number, measuring instruments, etc, and there have been few studies about the marginal fit of the Digident CAD/ CAM zirconia ceramic crowns. Purpose. The purpose of this study was to compare the marginal fit of the anterior single restorations made by using the Digident CAD / CAM zirconia ceramic crowns with metal-ceramic restorations and to obtain more accurate information by using a large enough sample size and by making sufficient measurements per specimen. Material and Methods. The crowns were made from one extracted maxillary central incisor pre-pared with a 1mm shoulder margin and $6^{\circ}$ taper walls by milling machine. The in vitro marginal discrepancies of the digident CAD / CAM zirconia ceramic crowns and control groups(metal ceramic crowns) were evaluated and compared. Twenty crowns per each system were fabricated. Measurements of a crown were recorded at 50 points that were randomly selected for marginal gap evaluation. Parametric statistical analysis was performed for the results. Conclusion. Within the limitations of this in vitro study, the following conclusions were drawn: 1. Mean gap dimensions and standard deviations at the marginal opening for maxillary incisal crowns were $88{\pm}10{\mu}m$ for the control (metal-ceramic crowns), $92{\pm}4{\mu}m$ for Digident CAD / CAM zirconia ceramic crowns. 2. Marginal gap between Digident CAD / CAM zirconia ceramic crowns and metal ceramic crowns did not show significant difference (P>.05). 3. The Digident CAD/ CAM zirconia ceramic crowns and metal ceramic crowns showed clinically acceptable marginal discrepancy.

포스트의 종류에 따른 Empress 2 도재관의 색상에 관한 비교연구 (COLOR COMPARISON OF VARIOUS POST SYSTEMS WITH EMPRESS 2 CROWNS)

  • 이영수;유동엽
    • 대한치과보철학회지
    • /
    • 제39권2호
    • /
    • pp.197-207
    • /
    • 2001
  • Development of new ceramics and esthetic needs of patients increase the use of all ceramic restorations. Fractured teeth often need metal post and core as foundation for final restoration. When all ceramic restorations are planned, metal post and core may lead to compromised esthetics because of opacity and gray color of metal post and core. Many techniques have been proposed to solve this problem such as application of an opaque porcelain to the metal core or all ceramic post and core. This study was performed to evaluate effect on color of Empress 2 crown according to various post systems. Color was evaluated by the CIE $L^*a^*b^*$ systems and measured by spectrophotometer (Model CM-3500, Minolta, Japan). Specimens were divided into 4 groups as follows Group 1 : gold cast post specimen + Empress 2 crown specimen Group 2 : application of an opaque porcelain to gold cast post specimen + Empress 2 crown specimen Group 3 : cosmopost specimen + Empress 2 crown specimen Group 4 : In-ceram post specimen + Empress 2 crown specimen. The results obtained as follows, 1. $L^*$ Values showed that group 2, 3, 4 were higher than group 1 with significant difference and group 2, 3, 4 were not significantly different. 2. $a^*$ Values and $b^*$ values also showed that group 2. 3, 4 were higher than group 1 with significant difference and group 2, 3, 4 were not significantly different. 3. ${\Delta}E^* ab$ Values showed that ${\Delta}E^* ab$ 3 was the highest value and ${\Delta}E^* ab$ 5 was the lowest value.

  • PDF

치아 부위에 따른 지르코니아 도재관의 파절강도 (Fracture strength of zirconia ceramic crowns according to tooth position)

  • 이인섭;김정미;동진근
    • 대한치과보철학회지
    • /
    • 제48권2호
    • /
    • pp.94-100
    • /
    • 2010
  • 연구목적: 본 연구는 상악과 하악의 각 치아부위에 $Lava^{TM}$ All-Ceramic System을 이용하여 지르코니아 전부도재관을 제작하고 각각의 파절강도를 알아보고자 하였다. 연구방법:중절치와 견치는 절단연의 삭제량을 2.0 mm, 소구치와 대구치는 교합면의 삭제량을 1.5 mm, 그리고 축면 경사도는 $8^{\circ}$로하여모두8군의 실험군을 설정하였다. 금속 다이와 지르코니아 도재관을 제작한 후 레진시멘트 (Rely $X^{TM}$ Unicem)를 이용하여 합착하고 만능시험기상에서 치아 장축에 $30^{\circ}$경사지게 하여 중절치와 견치에 제작된 지르코니아 도재관은 절단연 중앙 부위에 하중을 가하였고, 소구치와 대구치에 제작된 지르코니아 도재관은 기능교두의 협설측 경사면 중앙부위에 하중이 가해지도록 한 후 파절강도를 측정하였다. 결과:1. 지르코니아 도재관의 평균 파절강도는 하악 제1대구치에서 2963 N으로 가장 높게 나타났으며, 하악 중절치에서 1035 N으로 가장 낮게 나타났다. 2. 지르코니아 도재관과 IPS Empress 도재관과의 평균 파절강도는 모든 치아에서 지르코니아 도재관이 더 크게 나타났다. 3. 지르코니아 도재관의 파절 양상은 하중이 가해진 중앙 부위에서 치아 장축으로 수직적인 파절상을 보였다. 4. 상악과 하악의 동일 부위에 제작된 지르코니아 도재관의 파절강도는 소구치에서 상악이 하악에 비하여 낮은 것으로 나타났으며 (P< .05), 다른 부위에서는 유의한 차이가 없었다 (P> .05). 결론: 본 실험의 결과로 지르코니아 도재관은 임상에서 활용하기에 만족할 만한 강도를 갖고 있음을 알 수 있었다.

보철물 변연의 위치가 abfraction된 치아의 응력 분포에 미치는 영향에 대한 유한요소법적 분석 (Effect of the marginal position of prosthesis on stress distribution of teeth with abfraction lesion using finite element analysis)

  • 김명현;이청희
    • 대한치과보철학회지
    • /
    • 제52권3호
    • /
    • pp.202-210
    • /
    • 2014
  • 목적: 이 연구의 목적은 abfraction병소가 있는 금속도재관수복 치아를 수복하거나 하지 않을 때 나타나는 응력집중과 분포를 유한요소분석으로 평가하는 것이다. 재료 및 방법: 상악 제1 소구치를 선정하여 총 10개의 유한요소모델을 만들었다. 모델 1은 자연치; 모델 2는 협측과구개측 백악법랑경계 상방 2 mm에 변연이 위치한 금속도재관; 모델 3은 협측과구개측 백악법랑경계에 변연이 위치한 금속도재관; 모델 4는 abfraction병소를 가진 자연치; 모델 5와 6은 다른 조건은 각각 모델 2와 3과 동일하면서 abfraction병소를 가진 치아; 모델 7은 abfraction병소를 가지고 composite resin으로 수복된 자연치;모델 8과 9는 각각 모델 5와 6과 동일한 모델에 abfraction병소를 composite resin으로 수복한 후 금속도재관 장착한 치아; 모델 10은 composite resin으로 abfraction lesion을 수복하고 금속도재관의변연을 abfraction병소보다 하방에 위치시킨 치아였다. 위치를 서로 달리한 하중 load A와 load B를 가하여, 각 기준점에서의 von Mises stress값들을 측정하여 비교하였다. 결과: Abfraction병소가 있는 치아에 load A 또는 load B를 주었을 때, 응력은 lesion의 apex에 집중되었다. 반면, abfraction병소를 composite resin으로 충전한 치아에 load A 또는 load B를 주었을 때 응력값은 apex에서 감소하였다. 결론: Abfraction이 있는 치아는 복합 레진으로 수복해주는 것이 응력의 집중을 줄여서 병소의 예후에 유리한 것으로 나타났으며, Abfraction이 발생된 치아를 금속 도재관으로 수복할 경우 협측변연을 법랑질 상에 위치시키는 것이 유리하였다.