두개 안면부 내의 임의 부위를 평가시 정모두부 방사선 규격 사진과 측방 두부 방사선 규격 사진을 동시에 적절히 사용할시에는 3차원적 공간 개념을 인지함으로서 대상의 정확한 존재와 위치를 파악할 수 있다. 최근 교정학 분야에 있어서 점차 그 중요성과 사용 빈도가 증가하고 있는 정모 두부 방사선 규격 사진의 용도는 다음과 같다. 1. 교정 치료시 진단 및 치료 계획 과정에서의 이용 (1) 두부 안면부에서의 비대칭 부위와 양의 인지 (2) 교정 치료의 진단과 치료를 위한 therapeutic position의 평가 2. 교정 치료 mechanics의 성공 여부 평가 이같은 정모 두부 방사선 규격 사진을 측방두부 방사선 규격 사진과 등시에 적절히 사용 함으로서 정확한 진단과 그에 합당한 치료 계획을 수립할 수 있다.
The purpose of this study was to describe the morphologic differences between long-face adults and normal-face adults on the lateral and P-A cephalograms. Long-face and normal-face subifects were selected clinically, and then each of them was taken the lateral cephalogram. According to SN-MP angle and ATFH on the lateral cephalogram, long-face group and normal-face group were classified. 2 long-face adults and 18 normal-face adults were collected, and each of them was taken the P-A cephalogram. The results were as follows: 1. The morphologic differences between long-face adults and normal-face adults were closely related to mandibular morphology. 2. Long-face adults, compared with normal-face adults, demonstrated significant increase in ALFH, and significant decrease in ramus height. 3. Long-face adults, compared with normal-face adults, demonstrated significant increase in AUDH and, ALDH, especially in ALDH. 4. On the P-A cephalogram, no measures of transverse dimension demonstrated significant differences between two groups. 5. On the P-A cephalogram, facial height/facial width ratio was significantly larger than normal in the long-face adults, and in the normal-face adults, facial height/facial width ratio was approximately 90%. 6. In the correlation analysis of SN-MP angle and ATFH with all the other variables, the correlation coefficients of SN-MP angle and PTFH/ATFH that of ATFH and ALFH on the lateral cephalogram demonstrated the highest value, and on the P-A cephalogram, SN-MP angle and Cg-GA-Me (Lt.), ATFH and lower facial height demonstrated the highest value of correlation coefficients.
Journal of the Korean Association of Oral and Maxillofacial Surgeons
/
제29권4호
/
pp.239-244
/
2003
The common errors in preoperative treatment plan for the orthognathic surgery can be occurred during cast impression, cast mounting procedure with face-bow transfer, surgical stent fabrication, and so on. One of the most common errors exists during mounting process of the model on the articulator. Accurate mounting of dental casts to articulator should be achieved by transferring the 3-dimensional spatial relationship of the maxillary arch to an articulator. A face-bow is used for transfer this relationship to articulator, usually by relating the face-bow to a plane of reference of maxillary cast. The purpose of this study is evaluation of the accuracy of face-bow transferring of maxillary model to the articulator. The maxillary casts of thirty patients for orthognathic surgery were mounted on articulator with an face-bow instrument. The relationship of occlusal plane angle to Frankfort horizontal plane relations were compared the cephalogram with the cast-mounted articulator. As a result of this study, the significant difference between the maxillary occlusal planes angle in the cephalogram and articulator were found. The results were followed, 1. The mean occlusal plane angle in cast-mounted articulator was $13.5^{\circ}\;(SD{\pm}5.4)$. 2. The mean occlusal plane angle in cephalogram was $10.4^{\circ}\;(SD{\pm}4.3)$. 3. The mean difference of occlusal plane angle between cast-mounted articulator and cephalogram was $3.3^{\circ}\;(SD{\pm}4.6)$. According to the result, we should suggest that the occlusal plane angle to Frankfort plane in cast-mounted articulator is more steeper than that of cephalogram. And then, maxillofacial surgeon should try to get a more predictable result by suggesting the proper correction method and mounting the cast accurately.
Mandibular movements are guided mainly by three determinants, namely the two posterior controls (the Temporomandibular joints) and the anterior control (the incisal guidance). The aim of this study was to evaluate the incisal guide angle in effort to reconcile a patient's condylar guide angle and incisu guide angle, to develop criteria for incisal guidance in clinical practice. 48 subjects (male 33, female 15) with intact intercuspation, without past history and symptoms of stomatognathic system, were selected for this study. All of the subjects had not anterior prostheses. The sagittal condylar guide angles and incisal guide angles were measured and estimated statistically by cephalogram and articulator (Whip-Mix 8500A). The results of this study were as follows: 1. Average of condylar guide angle was 43.33 degree by cephalogram, and was 35.18 degree by articulator. 95% confidence interval was from 40.43 to 46.23 degrees in cephalogram and was from 32.98 to 37.38 degrees in articulator. 2. Average of incisal guide angle was 51.51 degree by cephalogram, and was 44.11 degree by articulator. 95% confidence interval was from 49.12 to 54.95 degrees in cephalogram and was from 40.67 to 47.56 douses in articulator. 3. Difference between condylar and incisal guide angle was 8.18 degree by cephalogram, and was 8.94 degree by articulator. 95% confidence interval was from 4.61 to 11.74 degrees in cephalogram and was from 4.90 to 12.98 degrees in articulator. 4. In case of the incisal guide angle steeper than condylar guide angle, subjects were 69% (33 of 48) in cephatogram and 75% (36 of 48) in articulator. 5. By the multiple regression equation, condylar guide angle was more influenced by the anterior teeth. 6. When the mandible protrudes from the intercuspal position to the edge to edge position the incisal linear movement was 4.18mm (S.D.:1.30mm) and the condylar linear movement was 4.38mm (S.D.:1.26mm).
6개의 건조두개골상의 중요한 방사선학적 계측점에 금속구를 위치시킨 후 3-D CT와 정모 및 측모 두부 방사선사진을 촬영하고 이를 바탕으로 만든 각각의 3차원 영상과 3차원 두부 방사선사진상의 각 계측점들이 3차원적으로 어느 정도의 정확성을 가지고 재현되는지를 알아보았다. 그리고 두 방법에 있어서의 계측점간의 거리계측을 실계측과 비교분석 함으로써 악안면부에서의 재현성과 정확성을 알아본 결과 다음과 같은 결과를 얻었다. 3-D CT와 3차원 두부 방사선사진상의 계측점들은 반복 계측시 각각 X축 방향으로 0.23 mm와 0.30 mm, Y축 방향으로 0.27 mm와 0.25 mm, 그리고 Z축 방향으로 0.27 mm와 0.31 mm의 표준편차를 보였다. 두 방법에서 모든 계측점이 0.5 mm 이하의 표준편차를 보였으며, 대부분의 계측점이 1 mm 이하의 범위를 보인 바, 두 방법 모두 통일한 건조두개골상의 계측점의 3차원적 위치 편차가 거의 없었다. 모든 계측항목에서 실측치와 3-D CT간의 차이는 평균 0.33 mm였으며, 실측치와 3차원 두부 방사선사진간의 차이는 평균 1.13 mm로 상대적으로 높게 나타났다. 가장 큰 차이를 보인 항목은 RGo과 LGo간으로 2.03 mm의 차이를 보였다. 그러나 두 방법 모두 모든 항목에서 실측치와 통계적으로 매우 높은 상관관계를 보였다(${\gamma}=0.976{\sim}1.000$, p<0.01).
At present, many orthodontists regard the root parallelism of the posterior teeth important not only in diagnosis and treatment planning but also for predicting posttreatment stability. To evaluate it, they usually refer to the orthopantomogram. At this study, 97 samples were collected from students of Yonsei University, who have well-proportioned face, Angle's class I canine & molar relationships and no crown axis deviation of the posterior teeth including canines. Reliability of the root parallelism observed from orthopantomogram was evaluated by comparison with $45^{\circ}$ oblique cephalogram. The results were as follows : 1. In comparing the differences between anglular measurements in $45^{\circ}$ oblique cephalogram & orthopantomogram with $5^{\circ}$, those to mandibular plane were significantly less than to occlusal plane in number of items which showed less differences than $5^{\circ}$. 2. Compared the root parallelisms in the orthopantomogram with those in $45^{\circ}$ oblique cephalogram with $1\%$ significance level, parallelism between upper canine & 1st premolar, lower canine & 1st premolar, lower 1st premolar & 2nd premolar, and lower right 2nd molar & 3rd molar showed statistically significant differences. 3. When the significance between the differences of the root parallelism between above two kinds of film and $5^{\circ}$ was verified by two sided paired t-test, more or less large difference was shown between lower right 2nd molar & 3rd molar, a little larger than $5^{\circ}$ between lower canine & 1st premolar, smaller at the rest of them. 4. In $45^{\circ}$ oblique cephalogram, lower canine & 1st premolar showed convergent root arrangements each other, while in orthopantomogram they were divergent each other. All the others except them showed convergency on the upper, divergency on the lower in both films.
Journal of the Korean Association of Oral and Maxillofacial Surgeons
/
제37권1호
/
pp.21-29
/
2011
Introduction: To compare the change in frontal ramal inclination (FRI) in laterognathism after orthognathic surgery. Materials and Methods: Twenty four patients (10 men, 14 women; mean age, $22.8{\pm}5.2$ years) with minimal facial canting (${\leq}$ 2 mm) and apparent menton deviation ($5.9{\pm}2.4\;mm$) who had been operated on to correct facial asymmetry and skeletal CIII malocclusion, were selected. On a preoperative posteroanterior (PA) cephalogram, the FRI of the deviated side and non deviated side, L1 deviation amounts and menton deviation amounts were measured. The FRI differences between both sides were compared, and the correlations between the measured deviated elements and the FRI differences were analyzed. On a postoperative PA cephalogram, the shifting amount of L1, shifting amount of L7 and FRI of both sides were measured, and the correlations between the shifting elements and the change in FRI were analyzed. Results: On the preoperative PA cephalogram, the FRI of the non deviated side was significantly greater than those of the deviated side. The differences in FRI, with a menton deviation amount showed a significant correlation. On the postoperative PA cephalogram, the FRI differences between the deviated and non deviated side were decreased significantly and mandibular transverse movement toward central position was noted. The mean shifting amounts of L7 were associated with the amount of change in the deviated side of FRI. Conclusion: Transverse shifting of the mandible through orthognathic surgery decreases the FRI difference, which showed laterognathism, and improves the facial contour.
The purpose of this study was to evaluate the nasal deviation in mandibular prognathism with mandibulo-facial asymmetry. There were 40 patients whose mandibular prognathism with/without facial asymmetry were treated with orthognathic surgery from March 2002 to October 2003. The Group A(n=20) had a mandibulo-facial asymmetry over 6mm menton deviation in cephalogram PA and the Group B(n=20) had a mandibular prognathism. The preoperative frontal photograph, cephalogram PA and three dimensionalcomputed tomography(divided in hard tissuse image and soft tissue image) of two group was evaluated NDA(nasal deviation angle) and MDA(mandibular deviation angle). The NDA was statistical difference between asymmetry Group A and symmetry Group B(p<0.01), and was deviated in affected side of asymmetry. The MDA were also statistical difference between Group A and Group B(p<0.01), however the measurements of MDA between the frontal photograph, 3D-CT and cephalogram PA were similar to each others. The low correlation of NDA between frontal photograph and cephalogram PA in Group A and B demonstrate that we couldn't assess nasal deviation in cephalogram PA. It could be concluded that patients with mandibulo-facial asymmetry have a nasal deviation and clinician must remember this fact when they assess and treat patients.
Cephalogram is one of the most important tool in researching growth and development of craniofacial area, orthodontic diagnosis and treatment planning. But its inherent distortion of actual length and angles during projecting three dimensional object to two dimensional plane might cause errors in quantitative analysis of shape and size. three dimensional high quality images can be obtained using computerized tomogram and have reported in literatures. Considering its expenses and amount of exposure to radiation, limitations still remain to be solved in its application to routine practice. construction of three dimensional image using principle of orientator can be obtained by biplanar stereoradiography. Theoretically two images, lateral and P-A can be used to construct three dimensional image provided that those are taken at same time by two different focal spots. As two images(lateral and P-A) obtained by conventional cephalogram have different head posture, those need compensation to construct three dimensional images. This study introduced principle of computerized head posture compensation and showed that conventional cephalogram could be used to construct three dimensional image and could be applied to routine orthodontic practice.
Surveying the developmental degree of the crowns of mandibular first bicuspid in 566 korean children (264 males and 302 females) from 3 to 7 years of age by oblique cephalogram, the author got to the following results. 1. The developmental degree of the tooth crown of mandibular first bicuspid was earlier in female than in male. 2. The period of complete development of the crown of mandibular first bicuspid was 7 year 1 month in male and 6 year 3 month in female. 3. There was no significant difference in the period of complete development of the tooth crown compared with that of Japanese and American children.
본 웹사이트에 게시된 이메일 주소가 전자우편 수집 프로그램이나
그 밖의 기술적 장치를 이용하여 무단으로 수집되는 것을 거부하며,
이를 위반시 정보통신망법에 의해 형사 처벌됨을 유념하시기 바랍니다.
[게시일 2004년 10월 1일]
이용약관
제 1 장 총칙
제 1 조 (목적)
이 이용약관은 KoreaScience 홈페이지(이하 “당 사이트”)에서 제공하는 인터넷 서비스(이하 '서비스')의 가입조건 및 이용에 관한 제반 사항과 기타 필요한 사항을 구체적으로 규정함을 목적으로 합니다.
제 2 조 (용어의 정의)
① "이용자"라 함은 당 사이트에 접속하여 이 약관에 따라 당 사이트가 제공하는 서비스를 받는 회원 및 비회원을
말합니다.
② "회원"이라 함은 서비스를 이용하기 위하여 당 사이트에 개인정보를 제공하여 아이디(ID)와 비밀번호를 부여
받은 자를 말합니다.
③ "회원 아이디(ID)"라 함은 회원의 식별 및 서비스 이용을 위하여 자신이 선정한 문자 및 숫자의 조합을
말합니다.
④ "비밀번호(패스워드)"라 함은 회원이 자신의 비밀보호를 위하여 선정한 문자 및 숫자의 조합을 말합니다.
제 3 조 (이용약관의 효력 및 변경)
① 이 약관은 당 사이트에 게시하거나 기타의 방법으로 회원에게 공지함으로써 효력이 발생합니다.
② 당 사이트는 이 약관을 개정할 경우에 적용일자 및 개정사유를 명시하여 현행 약관과 함께 당 사이트의
초기화면에 그 적용일자 7일 이전부터 적용일자 전일까지 공지합니다. 다만, 회원에게 불리하게 약관내용을
변경하는 경우에는 최소한 30일 이상의 사전 유예기간을 두고 공지합니다. 이 경우 당 사이트는 개정 전
내용과 개정 후 내용을 명확하게 비교하여 이용자가 알기 쉽도록 표시합니다.
제 4 조(약관 외 준칙)
① 이 약관은 당 사이트가 제공하는 서비스에 관한 이용안내와 함께 적용됩니다.
② 이 약관에 명시되지 아니한 사항은 관계법령의 규정이 적용됩니다.
제 2 장 이용계약의 체결
제 5 조 (이용계약의 성립 등)
① 이용계약은 이용고객이 당 사이트가 정한 약관에 「동의합니다」를 선택하고, 당 사이트가 정한
온라인신청양식을 작성하여 서비스 이용을 신청한 후, 당 사이트가 이를 승낙함으로써 성립합니다.
② 제1항의 승낙은 당 사이트가 제공하는 과학기술정보검색, 맞춤정보, 서지정보 등 다른 서비스의 이용승낙을
포함합니다.
제 6 조 (회원가입)
서비스를 이용하고자 하는 고객은 당 사이트에서 정한 회원가입양식에 개인정보를 기재하여 가입을 하여야 합니다.
제 7 조 (개인정보의 보호 및 사용)
당 사이트는 관계법령이 정하는 바에 따라 회원 등록정보를 포함한 회원의 개인정보를 보호하기 위해 노력합니다. 회원 개인정보의 보호 및 사용에 대해서는 관련법령 및 당 사이트의 개인정보 보호정책이 적용됩니다.
제 8 조 (이용 신청의 승낙과 제한)
① 당 사이트는 제6조의 규정에 의한 이용신청고객에 대하여 서비스 이용을 승낙합니다.
② 당 사이트는 아래사항에 해당하는 경우에 대해서 승낙하지 아니 합니다.
- 이용계약 신청서의 내용을 허위로 기재한 경우
- 기타 규정한 제반사항을 위반하며 신청하는 경우
제 9 조 (회원 ID 부여 및 변경 등)
① 당 사이트는 이용고객에 대하여 약관에 정하는 바에 따라 자신이 선정한 회원 ID를 부여합니다.
② 회원 ID는 원칙적으로 변경이 불가하며 부득이한 사유로 인하여 변경 하고자 하는 경우에는 해당 ID를
해지하고 재가입해야 합니다.
③ 기타 회원 개인정보 관리 및 변경 등에 관한 사항은 서비스별 안내에 정하는 바에 의합니다.
제 3 장 계약 당사자의 의무
제 10 조 (KISTI의 의무)
① 당 사이트는 이용고객이 희망한 서비스 제공 개시일에 특별한 사정이 없는 한 서비스를 이용할 수 있도록
하여야 합니다.
② 당 사이트는 개인정보 보호를 위해 보안시스템을 구축하며 개인정보 보호정책을 공시하고 준수합니다.
③ 당 사이트는 회원으로부터 제기되는 의견이나 불만이 정당하다고 객관적으로 인정될 경우에는 적절한 절차를
거쳐 즉시 처리하여야 합니다. 다만, 즉시 처리가 곤란한 경우는 회원에게 그 사유와 처리일정을 통보하여야
합니다.
제 11 조 (회원의 의무)
① 이용자는 회원가입 신청 또는 회원정보 변경 시 실명으로 모든 사항을 사실에 근거하여 작성하여야 하며,
허위 또는 타인의 정보를 등록할 경우 일체의 권리를 주장할 수 없습니다.
② 당 사이트가 관계법령 및 개인정보 보호정책에 의거하여 그 책임을 지는 경우를 제외하고 회원에게 부여된
ID의 비밀번호 관리소홀, 부정사용에 의하여 발생하는 모든 결과에 대한 책임은 회원에게 있습니다.
③ 회원은 당 사이트 및 제 3자의 지적 재산권을 침해해서는 안 됩니다.
제 4 장 서비스의 이용
제 12 조 (서비스 이용 시간)
① 서비스 이용은 당 사이트의 업무상 또는 기술상 특별한 지장이 없는 한 연중무휴, 1일 24시간 운영을
원칙으로 합니다. 단, 당 사이트는 시스템 정기점검, 증설 및 교체를 위해 당 사이트가 정한 날이나 시간에
서비스를 일시 중단할 수 있으며, 예정되어 있는 작업으로 인한 서비스 일시중단은 당 사이트 홈페이지를
통해 사전에 공지합니다.
② 당 사이트는 서비스를 특정범위로 분할하여 각 범위별로 이용가능시간을 별도로 지정할 수 있습니다. 다만
이 경우 그 내용을 공지합니다.
제 13 조 (홈페이지 저작권)
① NDSL에서 제공하는 모든 저작물의 저작권은 원저작자에게 있으며, KISTI는 복제/배포/전송권을 확보하고
있습니다.
② NDSL에서 제공하는 콘텐츠를 상업적 및 기타 영리목적으로 복제/배포/전송할 경우 사전에 KISTI의 허락을
받아야 합니다.
③ NDSL에서 제공하는 콘텐츠를 보도, 비평, 교육, 연구 등을 위하여 정당한 범위 안에서 공정한 관행에
합치되게 인용할 수 있습니다.
④ NDSL에서 제공하는 콘텐츠를 무단 복제, 전송, 배포 기타 저작권법에 위반되는 방법으로 이용할 경우
저작권법 제136조에 따라 5년 이하의 징역 또는 5천만 원 이하의 벌금에 처해질 수 있습니다.
제 14 조 (유료서비스)
① 당 사이트 및 협력기관이 정한 유료서비스(원문복사 등)는 별도로 정해진 바에 따르며, 변경사항은 시행 전에
당 사이트 홈페이지를 통하여 회원에게 공지합니다.
② 유료서비스를 이용하려는 회원은 정해진 요금체계에 따라 요금을 납부해야 합니다.
제 5 장 계약 해지 및 이용 제한
제 15 조 (계약 해지)
회원이 이용계약을 해지하고자 하는 때에는 [가입해지] 메뉴를 이용해 직접 해지해야 합니다.
제 16 조 (서비스 이용제한)
① 당 사이트는 회원이 서비스 이용내용에 있어서 본 약관 제 11조 내용을 위반하거나, 다음 각 호에 해당하는
경우 서비스 이용을 제한할 수 있습니다.
- 2년 이상 서비스를 이용한 적이 없는 경우
- 기타 정상적인 서비스 운영에 방해가 될 경우
② 상기 이용제한 규정에 따라 서비스를 이용하는 회원에게 서비스 이용에 대하여 별도 공지 없이 서비스 이용의
일시정지, 이용계약 해지 할 수 있습니다.
제 17 조 (전자우편주소 수집 금지)
회원은 전자우편주소 추출기 등을 이용하여 전자우편주소를 수집 또는 제3자에게 제공할 수 없습니다.
제 6 장 손해배상 및 기타사항
제 18 조 (손해배상)
당 사이트는 무료로 제공되는 서비스와 관련하여 회원에게 어떠한 손해가 발생하더라도 당 사이트가 고의 또는 과실로 인한 손해발생을 제외하고는 이에 대하여 책임을 부담하지 아니합니다.
제 19 조 (관할 법원)
서비스 이용으로 발생한 분쟁에 대해 소송이 제기되는 경우 민사 소송법상의 관할 법원에 제기합니다.
[부 칙]
1. (시행일) 이 약관은 2016년 9월 5일부터 적용되며, 종전 약관은 본 약관으로 대체되며, 개정된 약관의 적용일 이전 가입자도 개정된 약관의 적용을 받습니다.