• Title/Summary/Keyword: Central X-ray

Search Result 272, Processing Time 0.024 seconds

Dosimetric Characteristics of Dual Photon Energy Using Independent Collimator Jaws (고에너지 선형가속기의 Independent Collimator를 이용한 비대칭 방사선 조사시 방사선량 결정에 미치는 요인에 관한 연구)

  • Kim Jeung-kee;Choi Young-Min;Lee Hyung-Sik;Hur Won-Joo
    • Radiation Oncology Journal
    • /
    • v.14 no.3
    • /
    • pp.237-244
    • /
    • 1996
  • Purpose : The accurate dosimetry of independent collimator equipped for 6MV and 15MV X-ray beam was investigated to search for the optimal correction factor. Materials and Methods : The field size factors, beam quality and dose distribution were measured by using 6MV, 15MV X-ray Field size factors were measured from $3{\times}3cm^2$ to $35{\times}35cm^2$ by using 0.6cc ion chamber (NE 2571) at Dmax. Beam qualities were measured at different field sizes, off-axis distances and depths. Isodose distributions at different off-axis distance using $10\times10cm^2$ field were also investigated and compared with symmetric field. Result: 1) Relative field size factors was different along lateral distance with maximum changes in $3.1\%$ for 6MV and $5\%$ for 15MV. But the field size factors of asymmetric fields were identical to the modified central-axis values in symmetric field, which corrected by off-axis ratio at Dmax. 2) The HVL and PDD was decreased by increasing off-axis distance. PDD was also decreased by increasing depth For field size more than $5{\times}cm^2$ and depth less than 15cm, PDD of asymmetric field differs from that of symmetric one ($0.5\~2\%$ for 6MV and $0.4\~1.4\%$ for 15MV). 3) The measured isodose curves demonstrate divergence effects and reduced doses adjacent to the edge close to the flattening filter center was also observed. Conclusion . When asymmetric collimator is used, calculation of MU must be corrected with off-axis and PDD with a caution of underdose in central axis.

  • PDF

A Study on Design and Application of Tissue Compensator for 6MV X-rays (6MV X-선에 대한 조직 보상체의 제작 및 응용에 관한 연구)

  • Chai Kyu Young;Choi Eun Kyung;Chung Woong Ki;kang Wee Saing;Ha Sung Whan;Park Charn Il
    • Radiation Oncology Journal
    • /
    • v.7 no.1
    • /
    • pp.123-132
    • /
    • 1989
  • A radiation beam incident on an irregular or sloping surface produces the non-uniformity of absorded dose. The use of a tissue compensator can partially correct this dose inhomogeneity. The tissue compensator is designed based on the patient's three dimensional contour. After required compensator thickness was determined according to tissue deficit at $25cm\pm25cm$ field size, 10cm depth for 6MV x-rays, tissue deficit was mapped by isoheight technique using laser beam system. Compensator was constructed along the designed model using 0.8mm lead sheet or 5mm acryl plate. Dosimetric verification were peformed by film dosimetry using humanoid phantom. Dosimetric measurements were normalized to central axis full phantom readings for both compensated and non-compensated field. Without compensation, the percent differences in absorbed dose ranged as high as $12.1\%$ along transverse axis, $10.8\%$ along vertical axis. With the tissue compensators in place, the difference was reduced to $0\~43\%$ Therefore, it can be concluded that the compensator system constructed by isoheihnt technique can produce good dose distribution with acceptible inhomogeneity, and such compensator system can be effectively applied to clinical radiotherapy.

  • PDF

The width of the incisive canal and labial alveolar bone of the incisive canal: an assessment on CT images (전산화단층영상에서 절치관 및 순측 치조골 폭경에 관한 연구)

  • Roh Yang-Gyun;Jang Hyun-Seon;Kim Byung-Ock;Kim Jin-Soo
    • Imaging Science in Dentistry
    • /
    • v.36 no.3
    • /
    • pp.145-149
    • /
    • 2006
  • Purpose : To assess the width of the labial alveolar bone of the incisive canal and the width of the incisive canal on spiral computed tomographic images of the anterior portion of the maxilla. Materials and Methods : Study materials included 38 CT scans taken for preoperative planning of implant placement. Axial cross-sectioned image entirely showing the incisive canal was selected and scanned with 600 DPI resolution. The width of the labial alveolar bone of the incisive canal at an orifice to the oral cavity, middle portion, and an orifice to the nasal cavity and the diameter of the incisive canal at the middle portion were determined by two specialist using Digora for Windows 2.1 The statistical analyses were carried out using SPSS 12.0.1. Results : When the maxillary central incisors remained, the mean labial alveolar bone width were $6.81{\pm}1.41mm,\;6.46{\pm}1.33mm$, and $7.91{\pm}1.33mm$. When the maxillary central incisors were missed the mean width were $5.42{\pm}2.20mm,\;6.23{\pm}2.29mm$, and $7.89{\pm}2.13mm$. Conclusions : The labial alveolar bone width at middle portion and an orifice to the nasal cavity were of no statistical significant difference according to presence of the maxillary central incisors (P>0.05). The width between oral cavity and nasal cavity, middle portion and to nasal cavity revealed statistically significant difference (P<0.05).

  • PDF

Hydroxyapatite prepared from eggshell and mulberry leaf extract by precipitation method

  • Wu, Shih-Ching;Hsu, Hsueh-Chuan;Hsu, Shih-Kuang;Liu, Mei-Yi;Ho, Wen-Fu
    • Biomaterials and Biomechanics in Bioengineering
    • /
    • v.4 no.1
    • /
    • pp.21-32
    • /
    • 2019
  • Eggshell is a waste material after the usage of egg. In this work, biowaste chicken eggshells were used for preparing carbonated hydroxyapatite (HA) nanoparticles of high purity through aqueous precipitation method at room temperature. The eggshell-derived HA will be a cost-effective bioceramics for biomedical applications and an effective material-recycling technology. Additionally, mulberry leaf extract was used as a template to regulate the morphology, size and crystallinity of HA, and the effects of pH value were also examined. Characterization of the samples was performed by X-ray diffraction (XRD) and Fourier transform infrared (FT-IR) spectroscopy. Scanning electron microscopy (SEM) was used to determine the size, shape and morphology of HA. The results indicate that only one phase of HA were synthesized in the both absence and presence of mulberry leaf extract at pH of 7 and above, while DCPD or DCPA/DCPD phase was observed at pH 4 condition. The crystallite sizes of the HA samples obviously decreased when adding mulberry leaf extract as a template, while they decreased gradually as the solution pH levels increased. With increasing pH level from 7 to 14, the rod-like HA nanoparticles gradually changed to spherical shape at pH 14. Note that, the obtained product is Mg and Sr containing A- and B-type carbonate HA at alkaline pH and it can be a potential material for biomedical applications.

Characterization of Microstructure and Mechanical Properties of Mg-8Li-3Al-1Y Alloy Subjected to Different Rolling Processes

  • Zhou, Xiao;Liu, Qiang;Liu, Ruirui;Zhou, Haitao
    • Metals and materials international
    • /
    • v.24 no.6
    • /
    • pp.1359-1368
    • /
    • 2018
  • The mechanical properties and microstructure evolution of Mg-8Li-3Al-1Y alloy undergoing different rolling processes were systematically investigated. X-ray diffraction, optical microscope, scanning electron microscopy, transmission electron microscopy as well as electron backscattered diffraction were used for tracking the microstructure evolution. Tensile testing was employed to characterize the mechanical properties. After hot rolling, the $MgLi_2Al$ precipitated in ${\beta}-Li$ matrix due to the transformation reaction: ${\beta}-Li{\rightarrow}{\beta}-Li+MgLi_2Al+{\alpha}-Mg$. As for the alloy subjected to annealed hot rolling, ${\beta}-Li$ phase was clearly recrystallized while recrystallization rarely occurred in ${\alpha}-Mg$ phase. With regard to the microstructure undergoing cold rolling, plenty of dislocations and dislocation walls were easily observed. In addition, the microstructure of alloys subjected to annealed cold rolling revealed the formation of new fresh ${\alpha}-Mg$ grains in ${\beta}-Li$ phase due to the precipitation reaction. The mechanical properties and fracture modes of Mg-8Li-3Al-1Y alloys can be effectively tuned by different rolling processes.

Investigating the Effect of Homogenization Heat Treatment on the Microstructure and Texture of Magnesium Alloy Sheet Manufactured via Twin Roll Casting (트윈롤 주조법으로 제조된 마그네슘합금 판재의 균질화 열처리에 따른 미세조직 및 집합조직 발달)

  • Lee, Hee Jae;Park, No Jin
    • Journal of the Korean Society for Heat Treatment
    • /
    • v.34 no.3
    • /
    • pp.122-129
    • /
    • 2021
  • This study focuses on the microstructural development of 99% magnesium alloy sheet manufactured using twin roll casting (TRC) process. Herein, a plate with a thickness of 5 mm was manufactured using the TRC process, homogenization heat treatment was performed at 400℃ for 2-32 h, and finally, the change in microstructure was evaluated via optical microscopy and textural analysis. The results suggest that the plate manufactured using the TRC process was not destroyed and was successfully rolled into a plate. Microscopic observation suggested that the dendritic cast structure was arranged along the rolling direction. And the central layer of the rolled plate, where was present in a liquid state at the beginning of rolling, solidified later during the TRC process to form central segregation. The initial cast structure and inhomogeneous structure of the plate were recrystallized by homogenization heat treatment for only 2 h, and it was confirmed that the segregated part of the central layer became homogeneous and recrystallization occurred. Grain growth occurred as the heat treatment time increased, and secondary recrystallization occurred, wherein only some grains were grown. The textural analysis, which was conducted via X-ray diffraction, confirmed that the relatively weak basal plane texture developed using the TRC process was formed into a random texture after heat treatment.

Correlation Analysis of Factors Affecting the Collimator Size used during Lumbar Spine Lateral Examination in Digital Radiography System (디지털 방사선 장비에서 요추 측면 검사 시 사용되는 조사야 크기에 영향을 미치는 요인의 상관관계 분석)

  • Young-Cheol Joo;Sin-Young Yu
    • Journal of the Korean Society of Radiology
    • /
    • v.18 no.4
    • /
    • pp.345-353
    • /
    • 2024
  • The purpose of this study was to suggest an appropriate collimation size and central X-ray incidence point by analyzing the correlation between the collimation size used in lumbar lateral examination and factors affecting the collimation size. the lumbar lateral examination results of 148 patients suitable for the purpose of this study were analyzed. The measurement method was to set the total horizontal width shown in the image to the size of the irradiation field(collimation) used during the examination. The distance connected vertically from the end of the dorsal field to the apophyseal joint of the third lumbar vertebra(AJD), the distance from the dorsal end of the image field to the center of the body of the third lumbar vertebra(BD), and the distance from the end of the dorsal field of the image to the center of the pedicle of the third lumbar vertebra(PD). The distance was measured. For comparative analysis of the mean values of dependent variables according to gender, age, height, weight, and body mass index, the mean values were compared using the independent samples t test and one-way ANOVA. For post hoc analysis, duncan was used. The correlation between independent and dependent variables was analyzed using Pearson correlation analysis. In this study, statistical significance was set at a p value of 0.05 or lower. The average value of the collimation size during the lumbar spine lateral examination was 252.45 mm, AJD was 102.11 mm, BD was 141.17 mm, and PD was 119.73 mm. The mean values of collimation size, AJD, BD, and PD were larger in men than in women, but statistical significance for the difference in mean values by gender was found only in BD (p<0.05). There was a slight difference in the mean value of each group according to age, but there was no statistical significance (p>0.05). The collimation size and mean values of AJD, BD, and PD according to height, weight, and body mass index differed depending on the independent variables, and the differences were all statistically significant (p<0.05). As a result of the correlation analysis, field size and AJD, BD, and PD showed no correlation with gender and age, a weak positive correlation with height, and a medium positive correlation with weight and body mass index. The results of this study showed that CS was correlated with height, weight, and BMI during lumbar lateral examination. If the entrance point of the central X-ray is moved to the appophyseal joint by considering weight and BMI when adjusting the collimation size in clinical practice, it is expected that the collimation size can be reduced bu about 5%.

Is a Camera-Type Portable X-Ray Device Clinically Feasible in Chest Imaging?: Image Quality Comparison with Chest Radiographs Taken with Traditional Mobile Digital X-Ray Devices (카메라형 휴대형 X선 장치는 흉부 촬영에서 임상적 사용이 가능한가?: 기존의 이동형 디지털 X선 장치로 촬영한 흉부 X선 사진과 영상품질 비교)

  • Sang-Ji Kim;Hwan Seok Yong;Eun-Young Kang;Zepa Yang;Jung-Youn Kim;Young-Hoon Yoon
    • Journal of the Korean Society of Radiology
    • /
    • v.85 no.1
    • /
    • pp.138-146
    • /
    • 2024
  • Purpose To evaluate whether the image quality of chest radiographs obtained using a camera-type portable X-ray device is appropriate for clinical practice by comparing them with traditional mobile digital X-ray devices. Materials and Methods Eighty-six patients who visited our emergency department and underwent endotracheal intubation, central venous catheterization, or nasogastric tube insertion were included in the study. Two radiologists scored images captured with traditional mobile devices before insertion and those captured with camera-type devices after insertion. Identification of the inserted instruments was evaluated on a 5-point scale, and the overall image quality was evaluated on a total of 20 points scale. Results The identification score of the instruments was 4.67 ± 0.71. The overall image quality score was 19.70 ± 0.72 and 15.02 ± 3.31 (p < 0.001) for the mobile and camera-type devices, respectively. The scores of the camera-type device were significantly lower than those of the mobile device in terms of the detailed items of respiratory motion artifacts, trachea and bronchus, pulmonary vessels, posterior cardiac blood vessels, thoracic intervertebral disc space, subdiaphragmatic vessels, and diaphragm (p = 0.013 for the item of diaphragm, p < 0.001 for the other detailed items). Conclusion Although caution is required for general diagnostic purposes as image quality degrades, a camera-type device can be used to evaluate the inserted instruments in chest radiographs.

Synthesis, Potentiometric, Spectral Characterization and Microbial Studies of Transition Metal Complexes with Tridentate Ligand (세자리 리간드의 전이금속 착물에 대한 합성과 전위차 및 분광학적 확인 그리고 미생물학적 연구)

  • Jadhav, S.M.;Munde, A.S.;Shankarwar, S.G.;Patharkar, V.R.;Shelke, V.A.;Chondhekar, T.K.
    • Journal of the Korean Chemical Society
    • /
    • v.54 no.5
    • /
    • pp.515-522
    • /
    • 2010
  • A relation between antimicrobial activities and the formation constants of solid complexes of Cu(II), Ni(II), Co(II), Mn(II) and Fe(III) with tridentate Schiff base ligand, 4-hydroxy-3(1-{2-(benzylideneamino)-phenylimino}-ethyl)-6-methyl-2Hpyran-2-one (HL) derived from o-phenylene diamines, dehydroacetic acid (DHA) and p-chloro benzaldehyde have been studied. The ligand and metal complexes were characterized by elemental analysis, conductivity, magnetic susceptibility, thermal analysis, X-ray diffraction, IR, $^1H$-NMR, UV-vis and mass spectra. From the analytical data, the stiochiometry of the complexes was found to be 1:2 (metal:ligand) with octahedral geometry. The molar conductance values suggest the nonelectrolytic nature of metal complexes. The X-ray diffraction data suggests monoclinic crystal system for Ni(II) and orthorhombic crystal system for Cu(II) and Co(II) complexes. The IR spectral data suggest that the ligand behaves as tridentate ligand with ONN donor atoms sequence towards central metal ion. Thermal behavior (TG/DTA) and kinetic parameters calculated by Coats-Redfern method suggests more ordered activated state in complex formation. The protonation constants of the complexes were determined potentiometrically in THF:water (60:40) medium at $25^{\circ}C$ and ionic strength ${\mu}=0.1\;M$ ($NaClO_4$). Antibacterial activities in vitro were performed against Staphylococcus aureu and Escherichia coli. Antifungal activities were studied against Aspergillus Niger and Trichoderma. The effect of the metal ions and stabilities of complexes on antimicrobial activities are discussed.

A study on enamel thickness of maxillary incisors using X-ray micro computed tomography (MicroCT를 이용한 상악 전치의 법랑질 두께에 관한 연구)

  • Cho, Young-Won;Cho, Jin-Hyun;Lee, Kyu-Bok
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.48 no.4
    • /
    • pp.301-307
    • /
    • 2010
  • Purpose: The objectives of the current study are to assess the accuracy of X-Ray Micro Computed Tomography (microCT) in measuring enamel thickness and to evaluate enamel thickness in maxillary incisors of Koreans. Materials and methods: Five maxillary incisors were embedded in resin block. These teeth were longitudinally sectioned labiolingually through the medial axis. After polishing, the teeth were scanned using a microCT (X-EYE SYSTEM; DRGEM, Seoul, Korea). On a scanning electron microscope (S-4300; Hitachi, Tokyo, Japan) (${\times}20$) and a microCT, nearly identical planes were reconstructed. In each tooth, the thickness of labial enamel was measured 1, 3 and 5 mm above the cementoenamel junction (CEJ). Thus, the accuracy of the microCT was evaluated. In addition, using 26 maxillary central incisors and 11 maxillary lateral incisors, in the medial axis and 2 mm remote areas mesially and distally from the medial axis, the thickness of labial enamel was measured 1, 3 and 5 mm above the CEJ along the long axis of the teeth. Results: Measurements from nearly identical planes in physical and microCT sections differed by 3.81%. An independent t-test was performed and this showed that there were no significant differences in the measurements between the two methods. Mean values of labial enamel thickness in maxillary central incisors 1, 3 and 5 mm above the CEJ were $0.32{\pm}0.01$, $0.50{\pm}0.0.2$ and $0.70{\pm}0.02\;mm$, respectively. Mean values of labial enamel thickness in maxillary lateral incisors 1, 3 and 5 mm above the CEJ were $0.30{\pm}0.01$, $0.55{\pm}0.03$ and $0.80{\pm}0.02\;mm$, respectively. Conclusion: In measuring enamel thickness, microCT is one of useful way of measurement. So according to the results of this research, when restoring a porcelain laminate veneer on maxillary incisors in Koreans, careful consideration is needed in the amount of enamel reduction.