• Title/Summary/Keyword: Cellular band

Search Result 187, Processing Time 0.028 seconds

Coverage and Capacity Analysis for the Multi-layer CDMA Macro/Indoor-Pico Cell (중첩 설치된 CDMA 매크로/옥내 피코셀의 영역 및 용량 분석)

  • 최승욱
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.25 no.10B
    • /
    • pp.1641-1647
    • /
    • 2000
  • This paper presents an analysis of coverage and capacity for the multi-layer CDMA cellular system. The multi-layer CDMA system that shares a common frequency band consists of macrocells for outdoor users and picocells for indoor users. Though macrocells and picocells interfere with each other the capacity of the whole system can be increased, We have analyzed the effect of muual interference upon cell coverage soft handover areas and capacities. The parameters involved in the engineering of the system are discussed. The study results sow that we can control the service coverage of indoor picocells with the system parameters set properly. It is also show that the capacity of the whole system that the capacity of the whole system can be enhanced smoothly by deploying the indoor picocells within existing macrocells.

  • PDF

Prenatal Development of Gonadotropin Releasing Hormone (GnRH) Neurons in the Rat Brain (흰쥐 태아 뇌에서 GnRH 신경세포의 초기발생과정)

  • 이영기;최완성
    • The Korean Journal of Zoology
    • /
    • v.34 no.4
    • /
    • pp.491-499
    • /
    • 1991
  • The present experiment was carried out 1) to study the developmental topography of GnRH neuronal system and 2) to characterize the cellular localization of GnRH neurons in the prenatal brain development of the rat. At embryonic day (I) 14.5, immunoreactive cell bodies of GnRH were first seen in the nasal septum and in the ganglion terminate located in the ventral protion of the caudal olfactory bulb. Two days later (E 16.5), GnRH-containing neurons were observed at the level of olfactory tubercle and diagonal band of Broca, which is the first appearance in the intracerebral region. From 118.5, the topographic pattern of immunoreactive GnRH perikarya was similar to that of adult rats. The present data suggest that GnRH neurons were originated from the nasal septum and gradually extended to the hvpothalamic regions with increasing fetal age.

  • PDF

TDMA jammer suppression on CDMA overlay

  • 김동구;박형일
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.21 no.4
    • /
    • pp.961-971
    • /
    • 1996
  • The effect of inband TDMA narrow band jammers to DS-CDMA system performance and the suppression techniques are investigated using Monte Carlo simulations. TIA stantard North American Digital Cellular wea used as jammer. Levinson Dubin and conventional recursive least square algorithm were emphasized since these techniques can be implemented with a few DSPs for CDMA application. Two filter structures, i.e., complex suppression filter and real suppression filter in each inphase and quadrature channels, are investigated and their performances are compared. Complex suppression filter with Levinson Durbin algorithm of 20msec updata rate is the most promising with respect to implementation and performance poit of view. Implementation feasibility is discussed and the channel capacity lost by suppression is computed.

  • PDF

Assessment and Validation of the Reliability of Quality Measurement System for Wireless Data Services (무선데이터 서비스 품질 측정 시스템의 신뢰성 검증 및 평가)

  • Choi, Dong-Hwan;Park, Seok-Cheon
    • Journal of Information Technology Services
    • /
    • v.11 no.1
    • /
    • pp.239-246
    • /
    • 2012
  • The user increases around the WiBro and in which the mobile broad band service is the wireless internet base technology HSDPA, that is the cellular phone foundation technique, and moreover the issue about the user effective quality guarantee emerges but the quality control of the wireless network is the incomplete actual condition. Therefore, the reliability verification according to the development of the system for the performance measure for the continued wireless data service and it and evaluation are needed for the quality control. In this paper, the wireless data service quality measurement system was implemented with the design. The same test environment as the existing network performance measurement program was built for the reliability verification of the embodied device for measuring quality and evaluation and the cost performance was performed. It could confirm that design and embodied wireless data service quality measurement system operated accurately in this paper through the quality measure result value analysis.

A CMOS Wideband RF Energy Harvester Employing Tunable Impedance Matching Network for Video Surveillance Disposable IoT Applications (가변 임피던스 매칭 네트워크를 이용한 영상 감시 Disposable IoT용 광대역 CMOS RF 에너지 하베스터)

  • Lee, Dong-gu;Lee, Duehee;Kwon, Kuduck
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.68 no.2
    • /
    • pp.304-309
    • /
    • 2019
  • This paper presents a CMOS RF-to-DC converter for video surveillance disposable IoT applications. It widely harvests RF energy of 3G/4G cellular low-band frequency range by employing a tunable impedance matching network. The proposed converter consists of the differential-drive cross-coupled rectifier and the matching network with a 4-bit capacitor array. The proposed converter is designed using 130-nm standard CMOS process. The designed energy harvester can rectify the RF signals from 700 MHz to 900 MHz. It has a peak RF-to-DC conversion efficiency of 72.25%, 64.97%, and 66.28% at 700 MHz, 800 MHz, and 900 MHz with a load resistance of 10kΩ, respectively.

Alignment of transmitters in indoor visible light communication for flat channel characteristics

  • Curuk, Selva Muratoglu
    • ETRI Journal
    • /
    • v.44 no.1
    • /
    • pp.125-134
    • /
    • 2022
  • Visible light communication (VLC) systems incorporate ambient lighting and wireless data transmission, and the experienced channel in indoor VLC is a major topic that should be examined for reliable communication. In this study, it is realized that multiple transmitters in classical alignment are the forceful factors for channel characteristics. In the frequency band, fluctuations with sudden drops are observed, where the fluctuation shape is related to the source layout and receiver location. These varying frequency-selective channels need solutions, especially for mobile users, because sustained channel estimation and equalization are necessary as the receiver changes its location. It is proven that using light-emitting diodes (LEDs) with highly directional beams as sources or using a detector with a narrow field of view (FOV) in the receiver may help partially alleviate the problem; the frequency selectivity of the channel reduces in some regions of the room. For flat fading channel characteristics all over the room, LEDs should be aligned in hexagonal cellular structure, and detector FOV should be arranged according to the cell dimension outcomes.

APPLICATION OF TIME-OF-FLIGHT NEAR INFRARED SPECTROSCOPY TO WOOD

  • Tsuchikawa, Satoru;Tsutsumi, Shigeaki
    • Proceedings of the Korean Society of Near Infrared Spectroscopy Conference
    • /
    • 2001.06a
    • /
    • pp.1182-1182
    • /
    • 2001
  • In this study, the newly constructed optical measurement system, which was mainly composed of a parametric tunable laser and a near infrared photoelectric multiplier, was introduced to clarify the optical characteristics of wood as discontinuous body with anisotropic cellular structure from the viewpoint of the time-of-flight near infrared spectroscopy (TOF-NIRS). The combined effects of the cellular structure of wood sample, the wavelength of the laser beam λ, and the detection position of transmitted light on the time resolved profiles were investigated in detail. The variation of the attenuance of peak maxima At, the time delay of peak maxima Δt and the variation of full width at half maximum Δw were strongly dependent on the feature of cellular structure of a sample and the wavelength of the laser beam. The substantial optical path length became about 30 to 35 times as long as sample thickness except the absorption band of water. Δt ${\times}$ Δw representing the light scattering condition increased exponentially with the sample thickness or the distance between the irradiation point and the end of sample. Around the λ=900-950 nm, there may be considerable light scattering in the lumen of tracheid, which is multiple specular reflection and easy to propagate along the length of wood fiber. Such tendency was remarkable for soft wood with the aggregate of thin layers of cell walls. When we apply TOF-NIRS to the cellular structural materials like wood, it is very important to give attention to the difference in the light scattering within cell wall and the multiple specular-like reflections between cell walls. We tried to express the characteristics of the time resolved profile on the basis of the optical parameters for light propagation determined by the previous studies, which were absorption coefficient K and scattering coefficient S from Kubelka-Munk theory and n from nth power cosine model of radiant intensity. The wavelength dependency of the product of K/S and n, which expressed the light-absorbing and -scattering condition and the degree of anisotropy, respectively, was similar to that of the time delay of peak maxima Δt. The variation of the time resolved profile is governed by the combination of these parameters. So, we can easily find the set of parameters for light propagation synthetically from Δt.

  • PDF

A Compact 370 W High Efficiency GaN HEMT Power Amplifier with Internal Harmonic Manipulation Circuits (내부 고조파 조정 회로로 구성되는 고효율 370 W GaN HEMT 소형 전력 증폭기)

  • Choi, Myung-Seok;Yoon, Tae-San;Kang, Bu-Gi;Cho, Samuel
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.24 no.11
    • /
    • pp.1064-1073
    • /
    • 2013
  • In this paper, a compact 370 W high efficiency GaN(Gallium Nitride) HEMT(High Electron Mobility Transistor) power amplifier(PA) using internal harmonic manipulation circuits is presented for cellular and L-band. We employed a new circuit topology for simultaneous high efficiency matching at both fundamental and 2nd harmonic frequency. In order to minimize package size, new 41.8 mm GaN HEMT and two MOS(Metal Oxide Semiconductor) capacitors are internally matched and combined package size $10.16{\times}10.16{\times}1.5Tmm^3$ through package material changes and wire bonded in a new package to improve thermal resistance. When drain biased at 48 V, the developed GaN HEMT power amplifier has achieved over 80 % Drain Efficiency(DE) from 770~870 MHz and 75 % DE at 1,805~1,880 MHz with 370 W peak output power(Psat.). This is the state-of-the-art efficiency and output power of GaN HEMT power amplifier at cellular and L-band to the best of our knowledge.

Correlation between Magnifying Narrow-band Imaging Endoscopy Results and Organoid Differentiation Indicated by Cancer Cell Differentiation and its Distribution in Depressed-Type Early Gastric Carcinoma

  • Tatematsu, Hidezumi;Miyahara, Ryoji;Shimoyama, Yoshie;Funasaka, Kohei;Ohno, Eizaburou;Nakamura, Masanao;Kawashima, Hiroki;Itoh, Akihiro;Ohmiya, Naoki;Hirooka, Yoshiki;Watanabe, Osamu;Maeda, Osamu;Ando, Takafumi;Goto, Hidemi
    • Asian Pacific Journal of Cancer Prevention
    • /
    • v.14 no.5
    • /
    • pp.2765-2769
    • /
    • 2013
  • Background: A close association between patterns identified by magnifying narrow-band imaging (M-NBI) and histological type has been described. M-NBI patterns were also recently reported to be related to the mucin phenotype; however, detials remain unclear. Materials and Methods: We investigated the cellular differentiation of gastric cancer lesions, along with their mucosal distribution observed by M-NBI. Ninety-seven depressed-type early gastric cancer lesions (74 differentiated and 23 undifferentiated adenocarcinomas) were visualized by M-NBI. Findings were divided into 4 patterns based on abnormal microvascular architecture: a chain loop pattern (CLP), a fine network pattern (FNP), a corkscrew pattern (CSP), and an unclassified pattern. Mucin phenotypes were judged as gastric (G-type), intestinal (I-type), mixed gastric and intestinal (M-type), and null (N-type) based on 4 markers (MAC5AC, MUC6, MUC2, and CD10). The relationship of each pattern of microvascular architecture with organoid differentiation indicated by cancer cell differentiation and its distribution in each histological type of early gastric cancer was investigated. Results: All CLP and FNP lesions were differentiated. The cancer cell distribution showed organoid differentiation in 84.2% (16/19) and 61.1% (22/36) of the two types of lesions, respectively, and there was a significant difference from the unclassified pattern with organoid differentiation (p<0.001). Almost all (94.7%; 18/19) CSP lesions were undifferentiated, and organoid differentiation was observed in 72.2% (13/18). There was a significant difference from the unclassified pattern with organoid differentiation (p<0.05). Conclusions: Cellular differentiation and distribution are associated with microvascular architecture observed by M-NBI.

The Design of Predistortion Linearizer with Polar Function Generator for Cellular Band Using Even Order Harmonic Signals (2차 고조파 신호를 이용한 극 함수 발생기를 갖는 셀룰라 밴드용 전치 왜곡 선형화기 설계)

  • Kim, Ell-Kou;Jeon, Ki-Kyoung;Kim, Young;Kwon, Sang-Keun;Yoon, Young-Chul
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.17 no.11 s.114
    • /
    • pp.1050-1057
    • /
    • 2006
  • This paper proposes a new predistortion linearizer with amplitude modulator and PFG(Polar Function Generator) using second order harmonic signals. This linearizer consists of PFG that combine with in-phase and quadrature-phase of second harmonic signals and amplitude modulator in main path. The predistorted third order intermodulation distortion(IMD3) signals that are generated by amplitude modulator with fundamental and PFG signals, improve a amplifier nonlinear characteristics. The proposed linearizer and amplifier have been manufactured and tested to operate in cellular base-station transmitting band$(869\sim894MHz)$. The test results show that IMD3 can be removed by more than 22.5 dB in case of CW 2-tone signals ${\Delta}f=1$ MHz, and the adjacent channel power ratio(ACPR) also can be improved by more than 8.4 dB for CDMA IS-95 1FA signals.