• Title/Summary/Keyword: Cell Load

Search Result 1,194, Processing Time 0.036 seconds

Development of control system for complex microbial incubator (복합 미생물 배양기의 제어시스템 개발)

  • Hong-Jik Kim;Won-Bog Lee;Seung-Ho Lee
    • Journal of IKEEE
    • /
    • v.27 no.1
    • /
    • pp.122-126
    • /
    • 2023
  • In this paper, a control system for a complex microbial incubator was proposed. The proposed control system consists of a control unit, a communication unit, a power supply unit, and a control system of the complex microbial incubator. The controller of the complex microbial incubator is designed and manufactured to convert analog signals and digital signals, and control signals of sensors such as displays using LCD panels, water level sensors, temperature sensors, and pH concentration sensors. The water level sensor used is designed and manufactured to enable accurate water level measurement by using the IR laser method with excellent linearity in order to solve the problem that existing water level sensors are difficult to measure due to foreign substances such as bubbles. The temperature sensor is designed and used so that it has high accuracy and no cumulative resistance error by measuring using the thermal resistance principle. The communication unit consists of two LAN ports and one RS-232 port, and is designed and manufactured to transmit signals such as LCD panel, PCT panel, and load cell controller used in the complex microbial incubator to the control unit. The power supply unit is designed and manufactured to supply power by configuring it with three voltage supply terminals such as 24V, 12V and 5V so that the control unit and communication unit can operate smoothly. The control system of the complex microbial incubator uses PLC to control sensor values such as pH concentration sensor, temperature sensor, and water level sensor, and the operation of circulation pump, circulation valve, rotary pump, and inverter load cell used for cultivation. In order to evaluate the performance of the control system of the proposed complex microbial incubator, the result of the experiment conducted by the accredited certification body showed that the range of water level measurement sensitivity was -0.41mm~1.59mm, and the range of change in water temperature was ±0.41℃, which is currently commercially available. It was confirmed that the product operates with better performance than the performance of the products. Therefore, the effectiveness of the control system of the complex microbial incubator proposed in this paper was demonstrated.

Viral Load Dynamics After Symptomatic COVID-19 in Children With Underlying Malignancies During the Omicron Wave

  • Ye Ji Kim;Hyun Mi Kang;In Young Yoo;Jae Won Yoo;Seong Koo Kim;Jae Wook Lee;Dong Gun Lee;Nack-Gyun Chung;Yeon-Joon Park;Dae Chul Jeong;Bin Cho
    • Pediatric Infection and Vaccine
    • /
    • v.30 no.2
    • /
    • pp.73-83
    • /
    • 2023
  • Purpose: This study aimed to investigate the viral load dynamics in children with underlying malignancies diagnosed with symptomatic coronavirus disease 2019 (COVID-19). Methods: This was a retrospective longitudinal cohort study of patients <19 years old with underlying hemato-oncologic malignancies that were diagnosed with their first symptomatic severe acute respiratory syndrome coronavirus 2 polymerase chain reaction (PCR)-confirmed COVID-19 infection during March 1 to August 30, 2022. Review of electronic medical records and telephone surveys were undertaken to assess the clinical presentations and transmission route of the patients. Thresholds of negligible likelihood of infectious virus was defined as E gene reverse transcription (RT)-PCR cycle threshold (Ct) value ≥25. Results: During the 6-month study period, a total of 43 children with 44 episodes of COVID-19 were included. Of the 44 episodes, the median age of the patients included was 8 years old (interquartile range [IQR], 4.9-10.5), and the most common underlying disease was acute lymphoid leukemia (n=30, 68.2%), followed by patients post-hematopoietic stem cell transplantation (n=8, 18.2%). Majority of the patients had mild COVID-19 (n=32, 72.7%), and three patients (7.0%) had severe/critical COVID-19. Furthermore, 2.3% (n=1) died of COVID-19 associated acute respiratory distress syndrome. The largest percentage of the patients showed E gene RT-PCR Ct value ≥25 between 15-21 days (n=13, 39.4%), followed by 22-28 days (n=10, 30.3%). In 15.2% (n=5), E gene RT-PCR Ct value remained <25 beyond 28 days after initial positive PCR. Refractory malignancy status (β, 67.0; 95% confidence interval, 7.0-17.0; P=0.030) was significantly associated with prolonged duration of E gene RT-PCR <25. A patient with prolonged duration of E gene RT-PCR Ct value <25 was suspected to have infectivity shown by the transmission of the virus to his mother at day 86 after his initial positive test. Conclusions: Children that acquire symptomatic COVID-19 during refractory malignancy state are at a high risk for prolonged shedding warranting PCR-based transmission precautions in this cohort of patients.

Studies on Ancylostomiasis I. An Experimental Study on Hookworm Infection and Anemia (구충증(鉤蟲症)에 관(關)한 연구(硏究) 제1편(第1篇) 구충(鉤蟲)의 감염(感染) 및 구충성빈혈(鉤蟲性貧血)에 관(關)한 고찰(考奈))

  • Lee, Mun-Ho;Kim, Dong-Jip;Lee, Jang-Kyu;Seo, Byong-Sul;Lee, Soon-Hyung
    • The Korean Journal of Nuclear Medicine
    • /
    • v.1 no.1
    • /
    • pp.55-66
    • /
    • 1967
  • In view of its prevalence in the Far East area, a more detailed knowledge on the hookworm infection is one of the very important medical problems. The present study was aimed to; determine the infectivity of the artificially hatched ancylostoma duodenale larvae in man after its oral administration, evaluate the clinical symptomatology of such infection, determine the date of first appearance of the ova in the stool, calculate the blood loss per worm per day, assess the relation-ships between the ova count, infectivity(worm load), blood loss and severity of anemia. An erythrokinetic study was also done to analyse the characteristics of hookworm anemia by means of $^{59}Fe\;and\;^{51}Cr$. Materials and Methods Ten healthy male volunteers(doctors, medical students and laboratory technicians) with the ages ranging from 21 to 40 years were selected as the experimental materials. They had no history of hookworm infection for preceding several years, and care was taken not to be exposed to reinfection. A baseline study including a through physical examinations and laboratory investigations such as complete blood counts, stool examination and estimation of the serum iron levels was done, and a vermifuge, bephenium hydroxynaphoate, was given 10 days prior to the main experiment. The ancylostoma duodenale filariform larvae were obtained in the following manner; The pure ancylostoma duodenale ova were obtained from the hookworm anemia patients and a modified filter paper method was adopted to harvest larger number of infective larvae, which were washed several times with saline. The actively moving mature larvae were put into the gelatine capsules, 150 in each, and were given to the volunteers in the fasting state with 300ml. of water. The volunteers were previously treated with intramuscular injection of 15mg. of chlorpromazine in order to prevent the eventual nausea and vomiting after the larvae intake. The clinical symptoms and signs mainly of the respiratory and gastrointestinal tracts, appearance of the ova and occult blood in the stool etc. were checked every day for the first 20 days and then twice weekly until the end of the experiment, which usually lasted for about 3 months. Roentgenological survey of the lungs was also done. The hematological changes such as the red blood cell, white blood cell and eosinophil cell counts, hemoglobin content and serum iron levels were studied. The appearance of the ova in the stool was examined by the formalin ether method and the ova were counted in triplicate on two successive days using the Stoll's dilution method. The ferrokinetic data were calculated by the modified Huff's method and the apparent half survival time of the red blood cells by the modified Gray's method. The isotopes were simultaneously tagged and injected intravenously, and then the stool and blood samples were collected as was described by Roche et al., namely, three separate 4-day stool samples with the blood sample drawing before each 4-day stool collection. The radio-activities of the stools ashfied and the blood were separately measured by the pulse-height analyser. The daily blood loss was calculated with the following formula; daily blood loss in $ml.=\frac{cpm/g\;stool{\times}weight\;in\;g\;of\;4-day\;stool}{cpm/ml\;blood{\times}4}$ The average of these three 4-day periods was given as the daily blood loss in each patient. The blood loss per day per worm was calculated by simply dividing the daily blood loss by the number of the hookworm recovered after the vermifuge given twice a week at the termination of the experiment. The iron loss in mg. through the gastrointestinal tract was estimated with the daily iron loss in $mg=\frac{g\;Hgb/100ml{\times}ml\;daily\;blood\;loss{\times}3.40}{100}$ 3.40=mg of iron per g Hgb following formula; Results 1. The respiratory symptoms such as cough and sputum were noted in almost all cases within a week after the infection, which lasted about 2 weeks. The roentgenological findings of the chest were essentially normal. A moderate degree of febril reaction appeared within 2 weeks with a duration of 3 or 4 days. 2. The gastrointestinal symptoms such as nausea, epigastric fullness, abdominal pain and loose bowel appeared in all cases immediately after the larvae intake. 3. The reduction of the red blood cell count was not remarkable, however, the hemoglobin content and especially the serum iron level showed the steady decreases until the end of the experiment. 4. The white blood cells and eosinophil cells, on the contrary, showed increases in parallel and reached peaks in 20 to 30 days after the infection. A small secondary rise was noted in 2 months. 5. The ova first appeared in the stool in 40. 1 days after the infection, ranging from 29 to 51 days, during which the occult blood reaction of the stool became also positive in almost cases. 6. The number of ova recovered per day was 164, 320 on the average, ranging from 89,500 to 253,800. The number of the worm evacuated by vermifuge was in rough correlation with the number of ova recovered. 7. The infectivity of ancylostoma duodenale was 14% on the average, ranging from 7.3 to 20.0%, which is relatively lower than those reported by other workers. 8. The mean fecal blood loss was 5.78ml. per day, with a range of from 2.6 to 11.7ml., and the mean blood loss per worm per day was 0.30ml., with a range of from 0.13 to 0.73ml., which is in rough coincidence with those reported by other authors. There appeared to exist, however, no correlation between the blood loss and the number of ova recovered. 9. The mean fecal iron loss was 2.02mg. per day, with a range of from 1.20 to 3.89mg., which is less than those appeared in the literature. 10. The mean plasma iron disappearance rate was 0.80hr., with a range of from 0.62 to 0.95hr., namely, a slight accerelation. 11. The hookworm anemia appeared to be iron deficiency in origin caused by continuous intestinal blood loss.

  • PDF

The Effect on the Lower Limbs Joint as the Landing Height and Floor Pattern (착지 높이와 지면 형태가 하지 관절에 미치는 영향)

  • Kim, Eun-Kyong
    • Korean Journal of Applied Biomechanics
    • /
    • v.21 no.4
    • /
    • pp.437-447
    • /
    • 2011
  • In this study, the lower limbs joints were analyzed for features based on the biomechanical characteristics of landing techniques according to height and landing on the ground type (flats and downhill). In order to achieve the objectives of the study, changes were analyzed in detail contents such as the height and form of the first landing on the ground at different angles of joints, torso and legs, torso and legs of the difference in the range of angular motion of the joint, the maximum angular difference between joints, the lower limbs joints difference between the maximum moment and the difference between COM changes. The subjects in this study do not last six months did not experience joint injuries 10 males in 20 aged were tested. Experimental tools to analyze were the recording and video equipment. Samsung's SCH-650A model camera was used six units, and the 2 GRF-based AMTI were used BP400800 model. 6-unit-camera synchronized with LED (photo cell) and Line Lock system were used. the output from the camera and the ground reaction force based on the data to synchronize A/D Syc. box was used. To calculate the coordinates of three-dimensional space, $1m{\times}3m{\times}2m$ (X, Y, Z axis) to the size of the control points attached to the framework of 36 markers were used, and 29 where the body was taken by attaching a marker to the surface. Two kinds of land condition, 40cm and 60cm in height, and ground conditions in the form of two kinds of flat and downhill slopes ($10^{\circ}$) of the landing operation was performed and each subject's 3 mean two-way RM ANOVA in SPSS 18.0 was used and this time, all the significant level was set at a=.05. Consequently, analyzing the landing technique as land form and land on the ground, the changes of external environmental factors, and the lower limbs joints' function in the evaluation were significantly different from the slopes. Landing of the slop plane were more load on the joints than landing of plane. Especially, knee extensor moment compared to the two kinds of landing, slopes plane were approximately two times higher than flat plane, and it was statistical significance. Most of all not so much range of motion and angular velocity of the shock to reduce stress was important. In the further research, front landing as well as various direction of motion of kinetic, kinetic factors and EMG variables on lower limbs joints of the study in terms of injury-prevention-approach is going to be needed.

Application of Vision-based Measurement System for Estimation of Dynamic Characteristics on Hanger Cables (행어케이블의 동특성 추정을 위한 영상계측시스템 적용)

  • Kim, Sung-Wan;Kim, Nam-Sik
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • v.32 no.1A
    • /
    • pp.1-10
    • /
    • 2012
  • Along with the development of coasts, islands and mountains, the demand of long-span bridges increases which, in turn, brings forth the construction of cable-supported bridges like suspension and cable-stayed bridges. There are various types of statically indeterminate structures widely applied that supported the main girder with stay cables, main cables, hanger cables with aesthetic structural appearance. As to the cable-supported bridges, the health monitoring of a bridge can be identified by measuring tension force on cable repeatedly. The tension force on cable is measured either by direct measurement of stress of cable using load cell or hydraulic jack, or by vibration method estimating tension force using cable shape and measured dynamic characteristics. In this study, a method to estimate dynamic characteristics of hanger cables by using a digital image processing is suggested. Digital images are acquired by a portable digital camcorder, which is the sensor to remotely measure dynamic responses considering convenient and economical aspects for use. A digital image correlation(DIC) technique is applied for digital image processing, and an image transform function(ITF) to correct the geometric distortion induced from the deformed images is used to estimate subpixel. And, the correction of motion of vision-based measurement system using a fixed object in an image without installing additional sensor can be enhanced the resolution of dynamic responses and modal frequencies of hanger cables.

Design of eFuse OTP Memory with Wide Operating Voltage Range for PMICs (PMIC용 넓은 동작전압 영역을 갖는 eFuse OTP 설계)

  • Jeong, Woo-Young;Hao, Wen-Chao;Ha, Pan-Bong;Kim, Young-Hee
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.18 no.1
    • /
    • pp.115-122
    • /
    • 2014
  • In this paper, reliability is secured by sensing a post-program resistance of several tens of kilo ohms and restricting a read current flowing over an unblown eFuse within $100{\mu}A$ since RWL driver and BL pull-up load circuits using a regulated voltage of V2V ($=2V{\pm}10%$) are proposed to have a wide operating voltage range for eFuse OTP memory. Also, when a comparison of a cell array of 1 row ${\times}$ 32 columns with that of 4 rows ${\times}$ 8 columns is done, the layout size of 4 rows ${\times}$ 8 columns is smaller with $187.065{\mu}m{\times}94.525{\mu}m$ ($=0.01768mm^2$) than that of 1 row ${\times}$ 32 columns with $735.96{\mu}m{\times}61.605{\mu}m$ ($=0.04534mm^2$).

Effect of the Moisture Content and Pellet Mill Type on the Physical and Chemical Characteristics of Italian ryegrass Pellet (펠렛밀과 수분함량이 이탈리안 라이그라스 펠렛의 물리적 특성 및 화학적 성상에 미치는 영향)

  • Moon, Byeong Heoun;Shin, Jong Seo;Park, Hyung Soo;Park, Byeong Ki;Kim, Jong Geun
    • Journal of The Korean Society of Grassland and Forage Science
    • /
    • v.36 no.4
    • /
    • pp.271-279
    • /
    • 2016
  • The objective of this study was to determine the effect of the moisture content and pellet mill type on the physical and chemical characteristics of Italian ryegrass (IRG) pellet. Moisture content of raw material significantly (p<0.05) affected IRG pellet formation. Moisture content at 25% was the best condition for IRG pellet formation in terms of shape, power load and temperature changes. The hardness of pellet was decreased when moisture content was increase. However, the hardness of pellet was not affected by pellet mill type. Moisture content at 30% dramatically (p<0.05) decreased the durability compared to moisture content at 25%. Dry matter content of IRG pellet was increased (p<0.05) after pelleting. Total count of microorganism was decreased in pellet due to pressure heat and moisture losses during the pelleting process. These results indicated that the proper moisture content of Italian ryegrass pelleting would be at 25%. In addition, Roll & flat die type would be more suitable than Ring die and Die & flat die type in IRG pelleting. Pelleting works would be beneficial for improving forage quality and long storage.

Study of the fracture resistance of zirconia on posterior fixed partial dentures based on inter-abutment distance (지르코니아 고정성 국소의치의 지대치간 거리에 따른 파절저항성에 관한 연구)

  • Park, Gi-Beom;Shin, Soo-Yeon
    • Journal of Dental Rehabilitation and Applied Science
    • /
    • v.36 no.2
    • /
    • pp.61-69
    • /
    • 2020
  • Purpose: Zirconia fixed partial dentures with mandibular 2nd premolar and 2nd molar as abutments are fabricated and then the effects of inter-abutment distance on fracture resistance of zirconia fixed partial dentures is studied. Materials and Methods: The materials used in this study are Cameleon S zirconia block and S2 zirconia block, which are divided into CS Group and S2 Group applying different inter-abutment distance for each material, and the sintered zirconia fixed partial denture was luted to the epoxy resin die using a temporary luting cement, and then the fracture resistance was measured by placing a 6 mm diameter hardened steel ball on the occlusal surfaces of the pontics and applying pressure at a cross head speed of 1.0 mm/min on a universal testing machine with a load cell of 5.0 kN. Results: The fracture resistance of zirconia fixed partial dentures is not significantly affected by inter-abutment distance The fracture resistance of zirconia fixed partial dentures in CS Group was significantly higher in 15 mm of inter-abutment distance than in 13 mm and 17 mm of inter-abutment distance (P < 0.05). The fracture resistance of zirconia fixed partial dentures in S2 Group was not significantly different between the three groups (P > 0.05). Conclusion: The fracture resistance of zirconia fixed partial dentures with mandibular 2nd premolar and 2nd molar as abutments does not significantly affected by the inter-abutment distance.

Development of Post-installable Pullout Bolts and a Loading Device for Evaluating Concrete Strength (콘크리트 강도평가를 위한 인발장치와 후매입 인발볼트의 개발)

  • Ko, Hune-Bum;Lee, Ghang;Won, Jong-Sung
    • Journal of the Korea Institute of Building Construction
    • /
    • v.11 no.3
    • /
    • pp.229-237
    • /
    • 2011
  • The pullout test is a nondestructive testing method certified by the American Society for Testing and Materials (ASTM) and British Standards (BS). Research has shown that it is very reliable in terms of evaluating the concrete strength of reinforced concrete members. However, the pullout test is rarely performed on domestic construction sites due to the complex procedures and high costs involved. This study proposes a new pullout test composed of a post installable break-off bolt, an insert nut, and a pullout tester, which satisfy both economical and practical purposes on a construction site. Three different types of special fastening methods, a temporary fixed bolt, a plastic fixed panel, and a fixed bar, have been developed. A pullout tester is proposed that is driven by the circle force introduced into a handle composed of eight gears without a load cell and a hydraulic cylinder. The serviceability and reliability of these instruments were investigated through experiments at construction sites. Furthermore, the sample pullout test with a wall specimen was conducted to estimate the usefulness of the temporary fixed bolt type of fastening methods and pullout devices. Eventually, the developed instruments will be useful on construction sites if minor requirements are met.

Development of Diagnostic Techniques for Newcastle Disease in Chickens by In Situ RT-PCR and In Situ Hybridization (In situ RT-PCR 및 In situ hybridization 기법에 의한 닭 뉴캣슬병의 진단법 개발)

  • Park, Nam-Yong;Choi, Hyo-Im;Cho, Ho-Seong;Kang, Sung-Kwi;Cho, Kyoung-Oh;Brown, Corrie
    • Korean Journal of Veterinary Research
    • /
    • v.42 no.3
    • /
    • pp.351-362
    • /
    • 2002
  • Newcastle disease (ND) is a highly contagious infection of poultry, Two pathology-based techniques, in situ RT-PCR and in situ hybridization (ISH) were applied to formalin-fixed, paraffin-embedded tissues from chickens naturally infected with velogenic ND virus (VNDV). Two pairs of primers and a probe for ISH and in situ RT-PCR, respectively, were selected from highly conserved region of matrix gene of NDV. The ISH experiment was carried out using MicroProbe$^{TM}$ capillary action system within 2 hours. In situ RT-PCR was performed using MicroProbe$^{TM}$ capillary action system and GeneAmp In Situ PCR system. With ISH and in situ RT-PCR, viral nucleic acid was detected in the central nervous system of chickens from infected with neurotropic velogenic Newcastle disease virus (NVNDV), whereas viral nucleic acid was detected in various organs or tissues of chickens from infected with viscerotropic velogenic Newcastle disease virus (VVNDV). In the NVND group, positive signals were characteristically defined in the cytoplasm of neuron, vascular endothelial cells, and perivascular mononuclear macrophages in the central nervous system. One of NVND group, chicken from one farm exhibited positive signals in the bronchial epithelium. The VVND group chickens showed positive reaction in the macrophages, vascular endothelium, and bronchiolar epithelium. Markedly, viral nucleic acid was detected in the macrophages of morphologically normal tissues which were peripheral or located in distant areas from lesions. The central nervous system of chickens infected with VVND virus had positive signals in the vascular endothelial cell, perivascular mononuclear macrophages and some neuron. The number and intensity of the positive cells by in situ RT-PCR were more and stronger, respectively, in comparison with those by ISH. Particularly, positive reaction was detected in macrophages infiltrating in cardiac muscle by in situ RT-PCR, but not obtained by ISH. Therefore, these results demonstrated that ISH is a rapid diagnostic method for detection of NDV and in situ RT-PCR can be used as an efficient method for detection of low viral load infection or subclinical viral infection of NDV.