Abstract
The pullout test is a nondestructive testing method certified by the American Society for Testing and Materials (ASTM) and British Standards (BS). Research has shown that it is very reliable in terms of evaluating the concrete strength of reinforced concrete members. However, the pullout test is rarely performed on domestic construction sites due to the complex procedures and high costs involved. This study proposes a new pullout test composed of a post installable break-off bolt, an insert nut, and a pullout tester, which satisfy both economical and practical purposes on a construction site. Three different types of special fastening methods, a temporary fixed bolt, a plastic fixed panel, and a fixed bar, have been developed. A pullout tester is proposed that is driven by the circle force introduced into a handle composed of eight gears without a load cell and a hydraulic cylinder. The serviceability and reliability of these instruments were investigated through experiments at construction sites. Furthermore, the sample pullout test with a wall specimen was conducted to estimate the usefulness of the temporary fixed bolt type of fastening methods and pullout devices. Eventually, the developed instruments will be useful on construction sites if minor requirements are met.
Keywords
pullout tester; post-installable break-off bolt; installable pullout insert nut; building construction;
Citations & Related Records
Times Cited By KSCI : 1  (Citation Analysis)
연도 인용수 순위
1 Stone WC, Carino NJ, Reeve CP. Statistical methods for in-place strength predictions by the pullout test. Proceedings Journal of American Concrete Institute. 1986 sept;83(5):745-56.
2 Stone WC, Reeve CP. New statistical method for prediction of concrete strength from in-place tests. Cement, Concrete, and Aggregates. 1986 July;8(1):3-12.   DOI   ScienceOn
3 Kim GD, Lee SH, Kang SK, Kim JH, Kim KJ. [Evaluation of in-situ concrete strength with pull-out testing at the early ages]. Proceedings of the Korea Concrete Institute; 2007 May 4-5; Daegu (Korea): KCI; 2007. p.1087-90. Korean.
4 Claus GP, Ervin P. Pull-out testing by LOK-test and CAP-test. Birkerod(Denmark). Dansk Betoninstitut A/S;1992. p.31-8.
5 Ko HB.[Evaluation for high strength concrete using pullout test]. Journal of Korea Institute of Building Construction 2008 June;8(3): 85-91. Korean   과학기술학회마을   DOI   ScienceOn
6 Lisa RF, Bartlett FM. Bond strength variability in pullout specimens with plain reinforcement. American Concrete Institute Structural Journal. 2005 Dec;102(6):860-7.
7 Malhotra VM, Carette G. Comparison of pullout strength of concrete with compressive strength of cylinders and cores, pulse, velocity, and rebound number. American Concrete Institute Journal. 1980 May-Jun;77(3):161-70.
8 Bocca P. The application of pull-out test to high strength concrete estimation. Materials and Structures. 1984 May;17(3):211-6.
9 Price WF, Hynes JP. In-situ strenght testing of high strength concrete. Magazine of Concrete Research. 1996 Sept;48(176) :189-97.   DOI   ScienceOn
10 ACI Committee 228. In-place methods to estimate concrete strength. Michigan: American Concrete Institute(US); 2004 sept. p. 6-9. Report No.: ACI 228.1R-03.
11 ASTM. Standard test method for pullout strength of hardened concrete(ASTM C 900-82). Annual Book of ASTM Standards. Philadelphia (US): ASTM; 1983. p.582-5.
12 Richards O. Pullout strength of concrete. Reproducibility and accuracy of mechanical tests: STP-626. Philadelphia (US): American Society for Testing and Materials; 1977. p.32-40.