1 |
Campbell SD, Sozio RB. Evaluation of the fit and strength of an all-ceramic fixed partial denture. J Prosthet Dent 1988;59:301-6.
DOI
|
2 |
Tinschert J, Natt G, Mautsch W, Augthun M, Spiekermann H. Fracture resistance of lithium disilicate-, alumina-, and zirconia-based three-unit fixed partial dentures: a laboratory study. Int J Prosthodont 2001;14:231-8.
|
3 |
Kohorst P, Herzog TJ, Borchers L, Stiesch-Scholz M. Load-bearing capacity of all-ceramic posterior four-unit fixed partial dentures with different zirconia frameworks. Eur J Oral Sci 2007;115:161-6.
DOI
|
4 |
Meyenberg KH, Luthy H, Scharer P. Zirconia posts: a new all-ceramic concept for nonvital abutment teeth. J Esthet Dent 1995;7:73-80.
DOI
|
5 |
Wagner WC, Chu TM. Biaxial flexural strength and indentation fracture toughness of three new dental core ceramics. J Prosthet Dent 1996;76:140-4.
DOI
|
6 |
Keith O, Kusy RP, Whitley JQ. Zirconia brackets: an evaluation of morphology and coefficients of friction. Am J Orthod Dentofacial Orthop 1994;106:605-14.
DOI
|
7 |
Tinschert J, Natt G, Mautsch W, Spiekermann H, Anusavice KJ. Marginal fit of alumina- and zirconia-based fixed partial dentures produced by a CAD/CAM system. Oper Dent 2001;26:367-74.
|
8 |
Oh W, Gotzen N, Anusavice KJ. Influence of connector design on fracture probability of ceramic fixed-partial dentures. J Dent Res 2002;81:623-7.
DOI
|
9 |
El-Ebrashi MK, Craig RG, Peyton FA. Experimental stress analysis of dental restorations. VII. structural design and stress analysis of fixed partial dentures. J Prosthet Dent 1970;23:177-86.
DOI
|
10 |
Fischer H, Weber M, Marx R. Lifetime prediction of all-ceramic bridges by computational methods. J Dent Res 2003;82:238-42.
DOI
|
11 |
Mahmood DJ, Linderoth EH, Von Steyern PV, Wennerberg A. Fracture strength of all-ceramic (YTZP) three- and four-unit fixed dental prostheses with different connector design and production history. Swed Dent J 2013;37:179-87.
|
12 |
Luthardt RG, Sandkuhl O, Herold V, Walter MH. Accuracy of mechanical digitizing with a CAD/CAM system for fixed restorations. Int J Prosthodont 2001;14:146-51.
|
13 |
Schmitter M, Mussotter K, Rammelsberg P, Gabbert O, Ohlmann B. Clinical performance of longspan zirconia frameworks for fixed dental prostheses: 5-year results. J Oral Rehabil 2012;39:552-7.
DOI
|
14 |
Sailer I, Feher A, Filser F, Luthy H, Gauckler LJ, Scharer P, Franz Hammerle CH. Prospective clinical study of zirconia posterior fixed partial dentures: 3-year follow-up. Quintessence Int 2006;37:685-93.
|
15 |
Guazzato M, Albakry M, Ringer SP, Swain MV. Strength, fracture toughness and microstructure of a selection of all-ceramic materials. Part II. Zirconia-based dental ceramics. Dent Mater 2004;20:449-56.
DOI
|
16 |
Al-Amleh B, Lyons K, Swain M. Clinical trials in zirconia: a systematic review. J Oral Rehabil 2010;37:641-52.
DOI
|
17 |
Dahlmo KI, Andersson M, Gellerstedt M, Karlsson S. On a new method to assess the accuracy of a CAD program. Int J Prosthodont 2001;14:276-83.
|
18 |
Moldovan O, Luthardt RG, Corcodel N, Rudolph H. Three-dimensional fit of CAD/CAM-made zirconia copings. Dent Mater. 2011;27:1273-8
DOI
|
19 |
Beuer F, Naumann M, Gernet W, Sorensen JA. Precision of fit: zirconia three-unit fixed dental prostheses. Clin Oral Investig 2009;13:343-9.
DOI
|
20 |
Manicone PF, Iommetti PR, Raffaelli L. An overview of zirconia ceramics: basic properties and clinical applications. J Dent 2007;35:819-26.
DOI
|
21 |
Tinschert J, Schulze KA, Natt G, Latzke P, Heussen N, Spiekermann H. Clinical behavior of zirconiabased fixed partial dentures made of DC-Zirkon: 3-year results. Int J Prosthodont 2008;21:217-22.
|
22 |
Seo HW. The effect of aging process on the flexural strength of airborne particle abraded zirconia ceramics. Master's thesis, Seoul Nat'l Univ. 2015.
|
23 |
Yusuke Takuma, Syuntaro Nomoto, Toru Sato, Naoki Sugihara. Effect of Framework Design on Fracture Resistance in Zirconia 4-unit All-ceramic Fixed Partial Dentures. Bull Tokyo Dent Coll 2013;54:149-56.
DOI
|
24 |
Seo JY, Park IN, Lee KW. Fracture strength between different connector designs of zirconia core for posterior fixed partial dentures manufactured with CAD/CAM system. J Korean Acad Prosthodont 2006;44:29-39.
|
25 |
Ogino Y, Nomoto S, Sato T. Effect of connector design on fracture resistance in zirconia-based fixed partial dentures for upper anterior region. Bull Tokyo Dent Coll 2016;57:65-74.
DOI
|
26 |
Hamza TA, Attia MA, El-Hossary MM, Mosleh IE, Shokry TE, Wee AG. Flexural strength of small connector designs of zirconia-based partial fixed dental prostheses. J Prosthetic Dent 2016;115:224-9.
DOI
|
27 |
Bok SB. Study on the fracture resistance and reliability of zirconia posterior fixed partial denture. Ph. D. thesis, Dankook University. 2009.
|
28 |
Jang KJ. Effect of infiltration with ferric oxide contaning glass on the color, microstructure and strength of zirconia. Master's thesis, Chonnam Nat'l Univ. 2015.
|
29 |
Kim MC. Effects of zirconia sintering condition on flexural strength and grain size. Master's thesis, Korea Univ. 2014.
|
30 |
Park JW. A Comparative Study on the fracture strength of the multi coloured monolithic zirconia restoration. Kyungpook Nat'l Univ. 2016.
|
31 |
Lohbauer U, Amberger G, Quinn GD, Scherrer SS. Fractographic analysis of a dental zirconia framework: a case study on design issues. J Mech Behav Biomed Mater 2010;3:623-9.
DOI
|
32 |
Sobrinho LC, Cattell MJ, Glover RH, Knowles JC. Investigation of the dry and wet fatigue properties of three all-ceramic crown systems. Int J Prosthodont 1998;11:255-62.
|
33 |
Lee HH. Recent Dental Ceramics: Processing and Strengthening. J Korean Res Soc Dent Mater 2000;27:1-11.
|
34 |
Ardlin BI. Transformation-toughened zirconia for dental inlays, crowns and bridges: chemical stability and effect of low-temperature aging on flexural strength and surface structure. Dent Mater 2002;18:590-5.
DOI
|