• Title/Summary/Keyword: Cell Chip

Search Result 457, Processing Time 0.029 seconds

Fabrication of Current Intensity Convertible CLD of Large Current Intensity for LED Network Application (전류세기 조정이 가능한 대전력 발광다이오드 광원 회로용 정전류 다이오드 제작)

  • Park, Hwa-Jin;Yu, S.J.;Anil, K.;Yi, Yong-Gon;Kim, J.H.;Han, T.S.
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.25 no.9
    • /
    • pp.723-726
    • /
    • 2012
  • A current intensity convertible CLD chip was fabricated using small and large FET cell configuration. Pinch-off current of 8.82 mA and 11.56 mA were obtained for small and large cell in the CLD chip, respectively. Constant current was fairly maintained until the breakdown voltage of 60 V. Measured knee voltage, $V_k$ were 3.8 V and 4.5 V for small and large cell, respectively. We configured current amplifying chip with parallel connection of each cells, by connecting 8 individual large cells in parallel network, 92.0 mA of current was obtained. The pinch-off constant current of CLD chip was varied very linearly with respect to the number of parallel connected cell.

Effects of PCB Patterns on EMI Measurement in TEM Cell and Proposal of PCB Design Guidelines (TEM 셀에서 PCB 패턴이 EMI 측정에 미치는 영향 및 PCB 설계 가이드라인 제시)

  • Choi, Minkyoung;Shin, Youngsan;Lee, Seongsoo
    • Journal of IKEEE
    • /
    • v.21 no.3
    • /
    • pp.272-275
    • /
    • 2017
  • Recently, semiconductor integration density enormously increases and its interconnection width is significantly narrowed, which leads to EMI (electromagnetic interference) problems on chip level. Chip manufacturer exploits TEM cell (transverse electromagnetic cell) to measure EMI on chip level, which requires PCB (printed circuit board) for measurement purpose. However, it is often neglected to consider that PCB patterns and other factors can affect on EMI measurement. In this paper, several test patterns are designed for different PCB design variables, and effects of PCB patterns on EMI measurement in TEM cell are analyzed. Based on these analyses, PCB design guidelines are also proposed to minimize the effects on EMI measurements.

Analysis of Combined Yeast Cell Cycle Data by Using the Integrated Analysis Program for DNA chip (DNA chip 통합분석 프로그램을 이용한 효모의 세포주기 유전자 발현 통합 데이터의 분석)

  • 양영렬;허철구
    • KSBB Journal
    • /
    • v.16 no.6
    • /
    • pp.538-546
    • /
    • 2001
  • An integrated data analysis program for DNA chip containing normalization, FDM analysis, various kinds of clustering methods, PCA, and SVD was applied to analyze combined yeast cell cycle data. This paper includes both comparisons of some clustering algorithms such as K-means, SOM and furry c-means and their results. For further analysis, clustering results from the integrated analysis program was used for function assignments to each cluster and for motif analysis. These results show an integrated analysis view on DNA chip data.

  • PDF

Vision Chip for Edge and Motion Detection with a Function of Output Offset Cancellation (출력옵셋의 제거기능을 가지는 윤곽 및 움직임 검출용 시각칩)

  • Park, Jong-Ho;Kim, Jung-Hwan;Suh, Sung-Ho;Shin, Jang-Kyoo;Lee, Min-Ho
    • Journal of Sensor Science and Technology
    • /
    • v.13 no.3
    • /
    • pp.188-194
    • /
    • 2004
  • With a remarkable advance in CMOS (complimentary metal-oxide-semiconductor) process technology, a variety of vision sensors with signal processing circuits for complicated functions are actively being developed. Especially, as the principles of signal processing in human retina have been revealed, a series of vision chips imitating human retina have been reported. Human retina is able to detect the edge and motion of an object effectively. The edge detection among the several functions of the retina is accomplished by the cells called photoreceptor, horizontal cell and bipolar cell. We designed a CMOS vision chip by modeling cells of the retina as hardwares involved in edge and motion detection. The designed vision chip was fabricated using $0.6{\mu}m$ CMOS process and the characteristics were measured. Having reliable output characteristics, this chip can be used at the input stage for many applications, like targe tracking system, fingerprint recognition system, human-friendly robot system and etc.

Detection of ${\alpha}-Cyclodextrin$ and E.coli Cell Using Polydiacetylene Supramolecules

  • Lee, Gil-Sun;Choi, Hyun;Lee, Chung-Wan;Ahn, Dong-June;Oh, Min-Kyu;Kim, Jong-Man
    • Proceedings of the Polymer Society of Korea Conference
    • /
    • 2006.10a
    • /
    • pp.306-306
    • /
    • 2006
  • We immobilized and patterned PDA vesicles on solid substrate using micro arrayer, which have moieties to react with chemical and biological materials. Immobilized vesicle system was developed since it possesses many advantages in multiple screening, durable stability, and higher sensitivity. We applied polydiacetylene supramolecules to chemical and biological sensors for detection of ${\alpha}-cyclodextrin$ and E.coli cell selectively. This detection method could be applied as DNA chip, protein chip, and cell chip for multiple screening as well as chemical sensor by modifying the functional groups of diacetylene monomer.

  • PDF

Implementation of Radix-2 structure to reduce chip size (Chip면적 감소를 위한 Radix-2구조 구현)

  • 최영식;한대현
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 1999.05a
    • /
    • pp.407-410
    • /
    • 1999
  • Viterbi decoder is implemented with a Radix-4 architecture at 0.5$\mu\textrm{m}$ process even though the delay time of standard tell is big and it causes a bigger chip size. As process develops, the delay time of standard cells is getting smaller. Therefore, the requirement of speed and chip size is satisfied by using Radix-2 algorithm to implement Viterbi decoder.

  • PDF

1Kbit single-poly EEPROM IC design (1Kbit single-poly EEPROM IC 설계)

  • Jung, In-Seok;Park, Keun-Hyung;Kim, Kuk-Hwan
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2008.06a
    • /
    • pp.249-250
    • /
    • 2008
  • In this paper, we propose the single polycrystalline silicon flash EEPROM IC with a new structure which does not need the high voltage switching circuit. The design of high voltage switching circuits which are needed for the data program and erase, has been an obstacle to develop the single-poly EEPROM. Therefore, we has proposed the new cell structure which uses the low voltage switching circuits and has designed the full chip. A new single-poly EEPROM cell is designed and the full chip including the control block, the analog block, row decoder block, and the datapath block is designed. And the each block is verified by using the computer simulation. In addition, the full chip layout is performed.

  • PDF

Differential Gene Expression after Adenovirus-Mediated p16 Gene Transfer in Human Non-Small Cell Lung Cancer Cells (폐암세포주에서 아데노바이러스 매개 p16 유전자 전달로 인한 유전자 발현의 변화)

  • 박미선;김옥희;박현신;지승완;엄미옥;염태경;강호일
    • Toxicological Research
    • /
    • v.20 no.2
    • /
    • pp.109-116
    • /
    • 2004
  • For the safety evaluation of adenovirus-mediated gene transfer, we investigated differential gene expressions after transfecting adenoviral vector containing p16 tumor suppressor gene (Ad5CMV-p16) into human non-small cell lung cancer cells. In the previous study, we showed adenovirus-mediated $p16^{INK4a}$ gene transfer resulted in significant inhibition of cancer cell growth. We investigated gene expression changes after transfecting Ad5CMV-p16, Ad5CMV (null type, a mock vector) into A549 cells by using cDNA chip and oligonucleotide microarray chip (1200 genes) which carries genes related with signal transduction pathways, cell cycle regulations, oncogenes and tumor suppressor genes. We found that $p16^{INK4a}$ gene transfer down regulated 5 genes (cdc2, cyclin D3, cyclin B, cyclin E, cdk2) among 26 genes involved in cell cycle regulations. Compared with serum-free medium treated cells, Ad5CMV-p16 changed 27 gene expressions, two fold or more on oligonucleotide chip. In addition, Ad5CMV-p16 did not seem to increase the tumorigenicity-related gene expression in A549 cells. Further studies will be needed to investigate the effect of Ad5CMV-p16 on normal human cells and tissues for safety evaluation.

New GGNMOS I/O Cell Array for Improved Electrical Overstress Robustness

  • Pang, Yon-Sup;Kim, Youngju
    • JSTS:Journal of Semiconductor Technology and Science
    • /
    • v.13 no.1
    • /
    • pp.65-70
    • /
    • 2013
  • A 0.18-${\mu}m$ 3.3 V grounded-gate NMOS (GGNMOS) I/O cell array for timing controller (TCON) application is proposed for improving electrical overstress (EOS) robustness. The improved cell array consists of 20 GGNMOS, 4 inserted well taps, 2 end-well taps and shallow trench isolation (STI). Technology computer-aided design (TCAD) simulation results show that the inserted well taps and extended drain contact gate spacing (DCGS) is effective in preventing EOS failure, e.g. local burnout. Thermodynamic models for device simulation enable us to obtain lattice temperature distributions inside the cells. The peak value of the maximum lattice temperature in the improved GGNMOS cell array is lower than that in a conventional GGNMOS cell array. The inserted well taps also improve the uniformity of turn-on of GGNMOS cells. EOS test results show the validity of the simulation results on improvement of EOS robustness of the new GGNMOS I/O cell array.