• Title/Summary/Keyword: Cavity sensor

Search Result 146, Processing Time 0.026 seconds

Development of Die Technology of Mobile Phone Camera Module (모바일 폰 카메라 모듈 금형기술 개발)

  • Park, Joon-Hong;Jeon, Eon-Chan;Kim, Tae-Ho;Moon, Soon-Kyun
    • Journal of the Korean Society of Manufacturing Process Engineers
    • /
    • v.7 no.4
    • /
    • pp.17-23
    • /
    • 2008
  • Development of die technology for holder and barrel dies is necessary according to minimization of lens assembly, image sensor, and connectors. In these cases, there are two technical problems arising from die design. One is determination of knock-out pin location in die set. Minimization of lens assembly size make it difficult to obtain ejecting space. The other is whether or not high-precision die technology is possible to reduce torque variation when holer and barrel products is assembled. In this study, multi-cavity die set was developed taking advantage of gear-driven ejecting method. In the developed technology, die manufacturing technology was guaranteed with a high-precision level.

  • PDF

Quality Control System Based on Cbm in Injection Molding Product (CBM 기반의 사출품 품질 관리 시스템)

  • Park, Hong-Seok;Kim, Jong-Su
    • Transactions of the Korean Society of Machine Tool Engineers
    • /
    • v.18 no.2
    • /
    • pp.178-186
    • /
    • 2009
  • Most of automotive plastic parts are injection molding products. Inspection of total product is impossible, because number of product to inspect is too many and various. Condition-based Monitoring was proposed to decrease cost and time for inspecting. In this research, a system that predicts quality of part at fabrication point of time, and confirms informations through the internet was developed. Cavity sensors were installed inside of mold, and gathered signals as measuring, and through this process Sensor-based Monitoring system can be observed manufacturing of a part. Monitoring system transmits signals to client through the internet, and finally developed system provides manufacturing informations and predictions of quality as web-based monitoring.

A study on the air detector using relative dielectric constant (비유전율을 이용한 공기감지장치에 관한 연구)

  • Lee, Hyuk-Soo;Kim, Cheong-Worl
    • Journal of Sensor Science and Technology
    • /
    • v.16 no.5
    • /
    • pp.384-388
    • /
    • 2007
  • Air embolism can be a lethal complication of surgical procedures during which venous pressure at the site of surgery is sub-atmospheric or air is forced under pressure into a body cavity. To solve the problem, we developed the air detector using relative dielectric constant change, which is expected to be used broadly in industrial circles. We designed a detection circuit of sensing scheme. In experiments with a mock system, the proposed system showed a signal difference depending on the amount of air in the tygon tube of the mock system.

Technology of Mold Design and Manufacturing for Vacuum-Assisted Thermoforming Mold in Insert Film Injection Molding (INSERT FlLM 사출성형용 진공열성형 금형설계 및 제작기술)

  • Lee, S.H.;Ko, Y.B.;Lee, J.W.
    • 한국금형공학회:학술대회논문집
    • /
    • 2008.06a
    • /
    • pp.69-73
    • /
    • 2008
  • 본 연구에서는 고분자 플라스틱 부품의 친환경 외장성형공법인 Insert Film 사출성형공법중 첫 번째 공정인 진공성형공정에서 진공금형의 표면온도 균일화 기술에 대해 연구를 수행하였다. 진공금형의 온도분포 균일화를 위한 금형설계 및 설계된 금형에 대한 온도분포 평가를 위한 ANSYS를 이용한 유한요소열해석을 수행하였으며, 이때 정상상태 및 과도상태를 함께 평가하였다. 설계 결과를 바탕으로 금형을 제작하였으며, 생산성을 고려하여 4캐비티로 제작된 금형에 대해 금형표면의 온도분포 평가실험을 수행하였다. 또한 금형내 캐비티 온도센서 및 제어시스템을 설치하여 진공금형표면 온도분포가 항상 일정하게 유지될 수 있도록 금형시스템을 개발하였다. 결과적으로 일정한 온도범위의 금형표면온도제어가 가능하였다.

  • PDF

Synthesis of 6,7-Dibromo-1,4-dihydropentiptycene-1,4-epoxide (6,7-Dibromo-1,4-dihydropentiptycene-1,4-epoxide의 합성)

  • Yang, Jinseok;Um, Sungyong;Park, Cheolyoung
    • Journal of Integrative Natural Science
    • /
    • v.3 no.2
    • /
    • pp.103-106
    • /
    • 2010
  • Pentiptycene and its derivatives having cavity, ${\pi}-{\pi}$ stacking prohibition, and AIEE functionalities were synthesized. 6,7-Dibromo-1,4-dihydropentiptycene-1,4-epoxide was obtained from the reaction of 6,7-dibromo-1,4-dihydronaphthalene-1,4-epoxide and anthracene. All the synthesized compounds were characterized by fourier transform infrared spectroscopy (FTIR), 1H-NMR, and 13C-NMR spectroscopy. Prepared pentiptycene derivatives could be useful precursor for organofluorene compounds which could be an excellent candidate for electronic devices such as organic light-emitting diodes (OLED's) and chemical sensor.

EVALUATION OF VOLUME VELOCITY OF A LOUDSPEAKER IN A CHAMBER

  • Lee, J.S.;Ih, J.G.
    • Proceedings of the Acoustical Society of Korea Conference
    • /
    • 1994.06a
    • /
    • pp.770-774
    • /
    • 1994
  • The volume of an acoustic source is important in determining various acoustic parameters. One of the suggested techniques is the internal pressure method incorporating a loudspeaker attached to a chamber wall and a microphone inserted into the cavity. Although the method is easy to handle with a very simple measurement setup, the coupling effects between the dynamic system of the loudspeaker and acoustic field, and the effects of higher order modes introduced by the discontinuities in the acoustic field, and the effects of higher order modes introduced by the discontinuities in the acoustic field should be considered for precise result. In this study, higher order modes due to the discontinuities of loudspeaker and microphone boundaries are included and the electro-acoustic coupling effects are compensated for by using the results of two cylinders with different lengths. The volume velocity of a loudspeaker thus obtained agrees very with that measured by laser sensor.

  • PDF

One-Step Nanoscale Patterning of Silver Ionic Ink via Elastic Mold Deformation (탄성 몰드 변형을 이용한 은 이온 잉크의 원-스텝 나노스케일 패터닝)

  • Yong Suk Oh
    • Journal of Sensor Science and Technology
    • /
    • v.32 no.4
    • /
    • pp.252-256
    • /
    • 2023
  • A one-step method for nanoscale patterning of silver ionic ink on a substrate is developed using a microscale, elastic mold deformation. This method yields unique micro/nanoscale metallic structures that differ from those produced using the original molds. The linewidth of these metallic structures is significantly reduced (approximately 10 times) through the sidewall deformation of the original mold cavity on a thin liquid film, as verified by finite element analysis. The process facilitates the fabrication of various, isolated and complex micro/nanoscale metallic structures with negligible residual layers at low cost and high throughput. These structures can be utilized for various applications, including optoelectronics, wearable sensors, and metaverse-related devices. Our approach offers a promising tool for manipulation and fabrication of micro/nanoscale structures of various functional materials.

Fast Neutron Flux Determination by Using Ex-vessel Dosimetry (노외 감시자를 이용한 압력용기 중성자 조사량 결정)

  • Yoo, Choon-Sung;Park, Jong-Ho
    • Journal of Radiation Protection and Research
    • /
    • v.32 no.4
    • /
    • pp.158-167
    • /
    • 2007
  • It is required that the neutron dosimetry be present to monitor the reactor vessel throughout its plant life. The Ex-vessel Neutron Dosimetry Systems which consist of sensor sets, radiometric monitors, gradient chains, and support hardware have been installed for 3-Loop plants after a complete withdrawal of all six in-vessel surveillance capsules. The systems have been installed in the reactor cavity annulus in order to characterize the neutron energy spectrum over the beltline region of the reactor vessel. The installed dosimetry were withdrawn and evaluated after a irradiation during one cycle and then compared to the cycle specific neutron transport calculations. The reaction rates from the measurement and calculation were compared and the results show good agreements each other.

The Analysis of Resonance Characteristics of Asymmetric Dielectric Rod Resonator by Using Eigenfunction Expansion Method (고유함수 전개법을 이용한 비대칭 유전체 원주공진기의 공진특성 해석)

  • Min, Kyung-Ho;Ryu, Won-Yul;Choi, Hyun-Chul
    • Journal of Sensor Science and Technology
    • /
    • v.8 no.5
    • /
    • pp.407-413
    • /
    • 1999
  • The resonant frequency of dielectric rod resonator can be calculated very accurately by means of the concept of electric and magnetic walls from the symmetry. But in a real situation, when the supporter is placed in the cavity, asymmetry appears due to the supporter and its dielectric constant. Then we need research into the resonance characteristic of asymmetric dielectric resonator. In this paper, for the dielectric rod resonator which is placed in the asymmetric position in the conducting cavity, the equation for resonance characteristic was derived and the resonant frequency was calculated with the eigenfunction expansion method. We found that the calculated resonant frequency is very accurate when it was compared with the experimental result and that asymmetry affects the resonant frequency more in TM mode than in TE or in hybrid mode.

  • PDF

Development of Non-Contact Fiber Jumper Cord and Evaluation of Light Transmission Performance (비접촉식 광 점퍼 코드 개발 및 광 전송 성능 평가)

  • Kim, Heonyoung;Kang, Donghoon
    • Journal of the Korean Society for Nondestructive Testing
    • /
    • v.36 no.5
    • /
    • pp.399-405
    • /
    • 2016
  • Recently, fiber optic sensors, which have many advantages are being applied in various fields by replacing conventional electric sensors. To transmit the light signals between an interrogator and a sensor head, optical components such as an optical adaptor and optical jumper cords are generally used. When signals are transmitted using an adaptor, the end surface of each jumper cord is faced together. If alien substances exist on the core surface of an optical fiber, those can cause light transmission loss and signal disappearance. For this reason, non-contact fiber jumper cords are developed to overcome the problems that require continual attention. The light transmission performance of non-contact fiber jumper cords are also evaluated. From the test results, conventional fiber jumper cords are unable to transmit the signals over 2 mm cavity between the ends of both cords. Otherwise, non-contact fiber jumper cords can transmit the signals with stability up to the cavity of 7 mm though they have more transmission loss than the conventional ones. Consequently, non-contact fiber jumper cords that have better signal stability than conventional ones in environments are highly recommended in field applications, especially if they play a role as a cable for signal transmission between fiber optic sensors.