• Title/Summary/Keyword: Cavity detection

Search Result 183, Processing Time 0.032 seconds

Usefulness of Preoperative Breast MRI in Breast Cancer Diagnosed After Excisional Biopsy (유방 절제 생검 후 유방암이 진단된 환자에서 수술 전 자기공명영상의 유용성)

  • Wui, Jung-Hyun;Kang, Bong-Joo;Cha, Eun-Suk;Kim, Sung-Hun;Jung, Na-Young;Choi, Jae-Jeong
    • Investigative Magnetic Resonance Imaging
    • /
    • v.12 no.2
    • /
    • pp.161-169
    • /
    • 2008
  • Purpose : The aim of this study was to evaluate the usefulness of MRI performed after excisional biopsy to diagnose residual cancer and additional lesions. Materials and Methods : A total of 16 patients who had breast cancer diagnosed by excisional biopsy underwent preoperative breast MRI between March 2005 and August 2007 were included. MRI findings were considered positive for residual cancer if focal, thick, or irregular rim enhancement or adjacent enhancing lesion was identified around the postoperative biopsy cavity. And additional lesions separated from biopsy cavity including multifocal, multicentric, or contralateral lesion were evaluated. We evaluated the diagnostic accuracy of MRI, comparing MRI with histopathologic finding, and the impact of MRI on surgical planning. Results : The sensitivity and specificity of MRI for detecting residual disease considering rim enhancement were 85.7%(6/7) and 55.6%(5/9). Additional lesions including multifocal, multicentric, or contralateral lesion were found in 6 patients. In 7 patients, results of MRI findings changed surgical treatment planning. Conclusion : The pattern of rim enhancement on MRI after excisional biopsy is not differential point to evaluate remnant lesion. But MRI has an important role to help the detection of multifocal or multicentric, or contralateral breast malignancies, resulting in beneficial change in surgical treatment planning.

  • PDF

Fungal Osteomyelitis of Temporomandibular Joint and Skull Base Caused by Chronic Otitis Media

  • Kim, Bok Eum;Park, Keun Jeong;Lee, Jung Eun;Park, YounJung;Kwon, Jeong-Seung;Kim, Seong-Taek;Choi, Jong-Hoon;Ahn, Hyung-Joon
    • Journal of Oral Medicine and Pain
    • /
    • v.45 no.1
    • /
    • pp.12-16
    • /
    • 2020
  • Chronic otitis media (COM) is a chronic inflammatory disease which affects the middle ear, mastoid cavity. It presents hearing loss, ear pain, dizziness, headache, temporomandibular joint (TMJ) inflammation and intracranial complication. Intracranial complications such as skull base osteomyelitis (SBO) may occur secondary to COM due to transmission of infection by a number of possible routes. SBO is an uncommon condition with a significant morbidity and mortality if not treated in the early stages. We report a-67-year-old male patient with diabetes and untreated COM who presented atypical severe TMJ, periorbital and postmandibular pain. By computerized tomography (CT), magnetic resonance imaging (MRI) and whole body bone scan (WBBS), he was diagnosed with SBO spreading from untreated COM via infective arthritis of TMJ. Through this case, we suggest proper utilization of diagnostic imaging, especially CT or MRI for the early detection of SBO in the case of COM accompanying with the greater risk of infection developments such as diabetes.

Experimental Verification of Multipactor Sensitivity for S-band Diplexer (S 대역 Diplexer에 대한 Multipactor 민감도 시험)

  • Choi, Seung-Woon;Kim, Day-Young;Kwon, Ki-Ho;Lee, Yun-Ki
    • Aerospace Engineering and Technology
    • /
    • v.6 no.1
    • /
    • pp.83-91
    • /
    • 2007
  • An experimental verification of multipactor(MP) discharge for S-band diplexer as a sample DUT for space application by an in-house MP test facility is proposed. The designed diplexer having two BPFs for Rx and Tx is applied to a design of five pole inter-digital cavity type band pass filter with chebyshev response, it has 2.7 % bandwidth centered at 2.232 and 2.055 GHz for Rx, Tx, respectively. To avoid the MP discharge, the accurate design and analysis methods based on 3D EM field analysis are considered. The proposed in-house MP test facility consists of a phase detecting system using a doubly balanced mixer as a simple, low cost and real time MP test method compared with results of previously well-known MP detection systems as cross reference methods. The calculated MP threshold RF input power is 43.13 dBm. The measured one is 43 dBm and 44 dBm for CW, pulsed mode test, respectively.

  • PDF

Performance Comparison between Optical Fiber Type ESPI and Bulk Type ESPI for the Internal Defect in Pressure Vessel (광섬유형과 벌크형 ESPI를 이용한 압력용기 내부 결함 측정에 관한 비교 연구)

  • Kim, Seong-Jong;Kang, Young-June;Hong, Kyung-Min;Lee, Jae-Hoon;Choi, Nak-Jung
    • Journal of the Korean Society for Nondestructive Testing
    • /
    • v.32 no.2
    • /
    • pp.177-184
    • /
    • 2012
  • An optical defect detection method using ESPI(electronic speckle pattern interferometry) is proposed. ESPI is widely used as a non-contact measurement system which show deformation and phase map in real time. ESPI can be divided as the in-plane, out-of-plane and shearography by operation principle and target object and also divided with bulk type and optic fiber type by the optic configurations. This paper is focused on optic fiber type out-of-plane ESPI, which has the following advantages: (1) low cost; (2) reduction of the unreliable factors generated by separated optic components; (3) simplification of the optic configuration; (4) great reduction of volume; (5) flexibility, to be easily designed into different structures to adapt to inaccessible environments such as pipeline cavity and so on.

Single-frequency Wavelength Tunable Erbium-doped Fiber Ring Laser (단일 주파수로 발진하는 파장 가변 어븀 첨가 광섬유 링 레이저)

  • Kim, Ryun-Kyung;Chu, Su-Ho;Han, Young-Geun
    • Korean Journal of Optics and Photonics
    • /
    • v.21 no.5
    • /
    • pp.185-189
    • /
    • 2010
  • We demonstrate a single-frequency wavelength tunable erbium-doped fiber (EDF) ring laser. We used an unpumped-EDF as a saturable-absorber in order to obtain a stable single-frequency with a narrow-linewidth single-polarization mode in the ring cavity. The lasing wavelength was controlled by using bending-induced strain, such as tension and compression strain corresponding to the bending direction, applied to the fiber gratings. The fiber laser exhibited an output power of -1.85 dBm at a wavelength of 1540.72 nm for a pumping power of ~400 mW. An extinction ratio was measured to be more than 60 dB. The proposed tunable fiber laser maintains nearly the same output power while its lasing wavelength is controlled over in a wavelength range of 5 nm.

Production of antibodies for saxitoxin analysis and sensitivity analysis of anti-saxitoxin antiserum (삭시톡신 분석을 위한 항체의 제조 및 항-삭시톡신 항혈청의 민감도 분석)

  • Chang, Man;Lee, Gunsup;Moh, Sang Hyun;Shin, Kyoungsoon;Auh, Chung-Kyoon;Lee, Taek-Kyun
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.13 no.12
    • /
    • pp.6208-6214
    • /
    • 2012
  • The most essential but missing components to understand and use toxic substances from marine microalgae are developing the fast, easy and economical determining technology for detecting it. In this paper we produced the antibodies against saxitoxin (STX). Mariculture keyhole limpet hemocyanin (mcKLH) and ovalbumin (OVA) were used as carrier proteins. mcKLH-STX conjugates were injected into the peritonial cavity of BALB/c mouse for immunization. After bleeding from mouse, anti-STX antiserum was isolated. Indirect enzyme-linked immunosorbent assays (ELISA) was performed to determine antiserum titer using the microtiter plate coated with free STX and OVA-STX. A goat anti-mouse IgG-phosphatase conjugate was used as secondary antibody to enable chromogenic reaction. Reactions of anti-STX antiserum were very specific on the OVA-STX and free STX. Sensitivity of anti-STX antiserum on STX was very high and STX detection limit was to be 64.9 ng/kg for indirect ELISA.

Stage-Wise Presentation of Non-Metastatic Head and Neck Cancer: an Analysis of Patients from the Kumaon Hills of India

  • Pandey, Kailash Chandra;Revannasiddaiah, Swaroop;Pant, Nirdosh Kumar;Bhatt, Harish Chandra
    • Asian Pacific Journal of Cancer Prevention
    • /
    • v.15 no.12
    • /
    • pp.4957-4961
    • /
    • 2014
  • Background: Head and neck cancer without distant metastases is amenable to various modalities of treatment. However, the stage at presentation is a very important determinant for treatment success. The present study was conducted to determine the stage-wise presentation of non-metastatic head and neck cancer patients from the hilly regions in Kumaon division of Uttarakhand, India. Materials and Methods: The hospital records for non-metastatic head and neck cancer patients from the only functional cancer centre of the region for the period of two-years (January 2012-December 2013) were included. Nasopharyngeal carcinoma was excluded due to its staging system being different. Non-squamous histopathologies were also excluded. Patients hailing from nearby regions of Uttar Pradesh and Nepal were excluded, as were patients from non-hilly regions of Kumaon. Results: Of the 271 patients of head and neck cancer, 27 with distant metastases at diagnosis were excluded from the analysis. Of the 244 eligible patient records, 90.1% (n=222) were male, and 9.9% (n=22) were female. The proportions of patients with carcinoma of the larynx, oropharynx, oral cavity, hypopharynx and maxillary antrum were 31.9% (n=78), 27.9% (n=68), 20.5% (n=50), 12.7% (n=31) and 1.2% (n=3). A further 5.7% (n=14) were diagnosed as having secondary involvement of neck nodes with unknown primaries. The proportion of patients presenting in stages I, II, III, IVA and IVB were 0.8% (n=2), 2.5% (n=6), 9.4% (n=23), 51.6% (n=126) and 35.7% (n=87) respectively. Conclusions: An abysmally low proportion (3.3%) of non-metastatic head and neck cancer patients presented in the early stages (I and II). A vast majority of the patients (88.1%) presented with stages IVA and IVB. Not only does this reflect a poor therapeutic outlook, but also exposes the dire need for programmes focusing on cancer awareness and early detection in the region.

In vivo Optical Coherence Tomography Imaging of the Mesothelium Using Developed Window Models

  • Ahn, Yeh-Chan;Chae, Yu-Gyeong;Hwang, Sang Seok;Chun, Bong-Kwon;Jung, Maan Hong;Nam, Sung Jin;Lee, Hae-Young;Chung, Jae Min;Oak, Chulho;Park, Eun-Kee
    • Journal of the Optical Society of Korea
    • /
    • v.19 no.1
    • /
    • pp.69-73
    • /
    • 2015
  • The mesothelium is an essential lining for maintaining the normal homeostasis of the closed body cavity and a central component of pathophysiologic processes. The mesothelium has been known as the end target for asbestos which induces asbestos-related lung diseases. Malignant mesothelioma (MM) is a rare and fatal neoplasm predominantly due to asbestos exposure. Adaptation of an advanced and reliable technology is necessary for early detection of MM because it is difficult to diagnose this disease in its early stages. Optical coherence tomography (OCT) provides cross-sectional images of micro-tissue structures with a resolution of $2-10{\mu}m$ that can image the mesothelium with a thickness of ${\sim}100{\mu}m$ and, therefore, enable investigation of early development of MM. The mesothelium is typically located at the pleura and tunica vaginalis of the scrotum. In this study, we developed animal window models in the above two anatomical sites to visualize mesothelial layers within the mesothelium. OCT images at the two locations were also acquired.

THE CHANGES OF C-REACTIVE PROTEIN IN THE PATIENTS ASSOCIATED WITH MANDIBULAR FRACTURE (하악골 골절 환자에서의 C-Reactive Protein의 변화)

  • Gwak, Jong-Min;Kim, Chul-Hwan;Kim, Kyung-Wook
    • Maxillofacial Plastic and Reconstructive Surgery
    • /
    • v.28 no.1
    • /
    • pp.35-41
    • /
    • 2006
  • It is well known that concentration of C-reactive protein(CRP) in the serum increase as nonspecific reaction of the various tissue injury. The CRP, synthesized in the hepatocyte, is one of 'acute phase proteins' in the serum. The main signal patterns of this protein are regulated by synthesis of interleukin-I secreted from macrophage in the area of tissue injury. Many studies were performed for quantitative analysis for CRP according to various surgical operation, but the study for fracture patients associated with trauma, especially in mandible, are rare. The mandible fracture have intrinsic danger for infection in oral bacteria associated with open wound in oral cavity, and, are difficult for detection of tissue reaction between surgical swelling and infection by facial swelling. In this study, quantitative analysis for CRP associated tissue injury in mandibular fracture and surgical intervention was done, the results were as follows: 1. After initial mandibular trauma, the value of serum CRP diminished sequentially, most high value was presented in post-traumatic 2 days. 2. The CRP was diminished significantly 2 days after surgical intervention, and maintained normal value in 5 days after surgery. 3. The change of CRP are higher value in surgical intervention than initial trauma, it suggested that tissue injury from surgery was severe than trauma. 4. The high value of CRP was obtained in mandibular fracture combined soft tissue injury than no associated soft tissue injury. 5. In measurement of CRP according to surgical approach, highest serum value in patients of combined intra-oral and extra-oral approach was showed, and intra-oral approach, extra-oral approach, in sequential orders. 6. The CRP value are more higher in patient of 2 fracture site than only one fracture site. From the results obtained in this study, CRP has showed different values in mandibular fracture associated with severity of tissue injury and surgical intervention, and quantitative analysis of CRP value in serum can be applied to the clinical management of mandibular fracture.

Development of Dental Light Robotic System using Image Processing Technology (영상처리 기술을 이용한 치과용 로봇 조명장치의 개발)

  • Moon, Hyun-Il;Kim, Myoung-Nam;Lee, Kyu-Bok
    • Journal of Dental Rehabilitation and Applied Science
    • /
    • v.26 no.3
    • /
    • pp.285-296
    • /
    • 2010
  • Robot-assisted illuminating equipment based on image-processing technology was developed and then its accuracy was measured. The current system was designed to detect facial appearance using a camera and to illuminate it using a robot-assisted system. It was composed of a motion control component, a light control component and an image-processing component. Images were captured with a camera and following their acquisition the images that showed motion change were extracted in accordance with the Adaboost algorithm. Following the detection experiment for the oral cavity of patients based on image-processing technology, a higher degree of the facial recognition was obtained from the frontal view and the light robot arm was stably controlled.