• 제목/요약/키워드: Cast stainless steel

검색결과 111건 처리시간 0.03초

열화 주조 스테인리스강의 환경피로균열 진전 거동 (Environmental Fatigue Crack Propagation Behavior of Aged Cast Stainless Steel)

  • 정일석;이용성;김상재;송택호;조선영
    • 대한기계학회:학술대회논문집
    • /
    • 대한기계학회 2004년도 춘계학술대회
    • /
    • pp.78-83
    • /
    • 2004
  • Environmental fatigue crack propagation of CF8M and CF8A steels used in the domestic PWR were investigated on the simulated PWR condition(Temperature: $316^{\circ}C$, Pressure: 15MPa). The test equipment for environmental fatigue(high temperature-high pressure loop, autoclave, load frame, measurement system) were designed. As-received and 60-year aged specimens were used in the test. To compare with environmental fatigue test, another test was performed in the air condition. The fracture surface of specimens were difficult to verify the fracture modes such as striation, intergranular crack and cleavage and so on. As the ferrite content of CF8M is increased, more particles covered fracture surface were peeled.

  • PDF

주조 스테인리스강 CF8M의 43$0^{\circ}C$ 열화거동에 관한 연구 (II) -저사이클 피로특성 평가- (A Study on the 43$0^{\circ}C$ Degradation Behavior of Cast Stainless Steel(CF8M)(II)-Evaluation of Low Cycle Fatigue Characteristics-)

  • 권재도;우승완;박중철;이용선;박윤원
    • 대한기계학회논문집A
    • /
    • 제24권9호
    • /
    • pp.2183-2190
    • /
    • 2000
  • A thermal aging is observed in a primary reactor cooling system(RCS) made of a casting stainless steel when the RCS is exposed for long period at the reactor operating temperature, 290~3300C An investigation of effects of thermal aging on a low cycle fatigue characteristics included a stress variations caused by a reactor operation and trip, is required. The purpose of the present investigation is to find an effect of a thermal aging of the CF8M on a low cycle fatigue life. The specimen of CF8M are prepared by an artificially accelerated aging technique holding 300 and 1800hr at 4300C respectively. The low cycle fatigue tests for the virgin and two aged specimens are performed at the room temperature for various strain amplitudes($\varepsilon$ta), 0.3, 0.5, 0.8, 1.0, 1.2 and 1.5% strain. Through the experiment, it is found that the fatigue life is rapidly reduced with an creasing of the aging time. The experimental fatigue life estimation formulas between the virgin and two aged specimen are obtained and are proposed to a analysis purpose.

Cu-Sn 삽입금속을 이용한 DP강의 아크 브레이징 접합부의 미세조직과 인장특성 (Microstructure and Tensile Strength Property of Arc Brazed DP steel using Cu-Sn Insert Metal)

  • 조욱제;조영호;윤중길;강정윤
    • Journal of Welding and Joining
    • /
    • 제31권1호
    • /
    • pp.58-64
    • /
    • 2013
  • The following results were obtained, microstructures and tensile properties in arc brazed joints of DP(dual phase) steel using Cu-5.3wt%Sn insert metal was investigated as function of brazing current. 1) The Fusion Zone was composed of ${\alpha}Fe+{\gamma}Cu$ and Cu23Sn2. The reason for the formation of these solid solutions. Despite, Fe & Cu were impossible to solid solution at room temperature. It's melting & reaction to something of insert metal & Base Metal (DP Steel) by Arc. Brazing Process has faster cooling rate then Cast Process, Supersaturated solid solution at room temperature. 2) The increase Hardness of Fusion Zone was directly proportional to the rise of welding current. Because, ${\alpha}Fe+{\gamma}Cu$ phase (higher hardness than the Cu23Sn2.(104.1Hv < 271.9Hv)) Volume fraction was Growth, due to increasing the amount of base metal melting by High current. 3) The results of tensile shear test by Brazing, All specimens happen to fracture in Fusion Zone. On the other hand, when Brazing Current increasing tend to rise tensile load. but it was very small, about 26-30% of the base metal. 4) The result of fracture analysis, The crack initiate at Triple Point for meet to Upper B.M/Under B.M/Fusion Zone. This Crack propagated to Fusion zone. So ruptured by tensile strength. The Reason to in the fusion zone fracture, Fusion zone by Brazing of hardness (strength) was very lower then the base metal (DP steel). In addition the Fusion Zone's thickness in triple point was thin than the base metal's thickness in triple point.

전부주조금관 치경부 변연의 형태가 치경부 변연적합에 미치는 영향 (THE EFFECT OF VARIOUS FINISH LINE PREPARATIONS ON THE MARGINAL SEAL OF FULL CROWN PREPARATIONS)

  • 김순영;이석현;조광헌
    • 대한치과보철학회지
    • /
    • 제28권2호
    • /
    • pp.165-174
    • /
    • 1990
  • 현재 임상에서 사용되고 있는 니켈-크롬합금(Washiloy Soft, Kamemizu Chemical Inc. Ltd., Japan)을 이용하여 Chamfer, shoulder, shoulder with a $45^{\circ}$ bevel의 각 치경부 변연의 형태에 따른 시멘트층 피막후경을 교합면 및 치경부에서 측정, 비교하여 다음과 같은 결론을 얻었다. 금관의 교합면 장착정도는 chamfer가 가장 우수하고, 다음으로는 shoulder, shoulder with a $45^{\circ}$ bevel의 순이며, 이들 간에는 유의성 있는 차이를 나타내었다(p<.05). 금관의 치경부 적합도는 chamfer가 가장 우수하고, 다음으로 shoulder with a $45^{\circ}$ vevel, shoulder의 순이며, 이들 간에는 유의성 있는 차이를 나타내었다(p<.05).

  • PDF

코어 형태와 시멘트 종류에 따른 전부주조금관의 유지력에 관한 연구 (A STUDY OF CORE TYPE AND LUTING CEMENTS ON COMPLETE CAST CROWN RETENTION)

  • 백상현;장익태;이선형;양재호;허성주
    • 대한치과보철학회지
    • /
    • 제38권2호
    • /
    • pp.169-177
    • /
    • 2000
  • The purpose of this study was to compare the retention of complete cast crown over amalgam ores, composite resin cores, and cast gold cores when cemented with three different luting agents. Eighteen core specimens each of amalgam(Bestaloy, Dong Myung, Seoul, Korea), composite resin (Z100, 3M Dental product, st. Paul, Minn) and type IV gold alloy (Ba-4, Heesung Engelhard Corp., Korea) were made in a customized milling stainless steel die. A wax pattern with a loop attached to occlusal surface was made for each core and a type II gold alloy casting was fabricated. The castings which had clinically acceptable marginal fit were used as test samples. The following luting cements were used to cement cast crowns on each core material : (1) zinc phosphate cement (Confi-dental Products Co., USA) (2) glass-ionomer cement (Fuji Plus, GC Industrial Corp., Tokyo, Japan) (3) resin cement (Panavia 21, Kuraray Co., USA). All cements were mixed according to manufacturers' instructions. A static load of 5kg was then applied for 10 minutes on the crowns. All specimens were stored in saline solution for 24 hours at $37^{\circ}C$ and thermocycled for 500 cycles. After storage and cycling, the tensile bond strengths were measured by using a universal testing machine (Instron Corp., Canton, Mass.) at a crosshead speed of 0.5mm/min. The results were as follows 1. The retentive strength of resin cement was the highest of alt three types of cement for resin core (p<0.05). 2. There was no statistical difference among the retentive strengths of three cements for amalgam core (p>0.05). 3. The retentive strength of resin cement was higher than that of zinc phosphate for cast core, but there was no difference between the retentive strength of glass ionomer cement and those of rein and zinc phosphate cement. 4. The retentive strength of the zinc phosphate cement for amalgam core was the highest of all type of cores.

  • PDF

유체 환경하에서의 고분자 기지 복합재료와 금속재의 캐비테이션 침식 특성 (Cavitation-Erosion Characteristics between Polymer Based Composites and Metals under the Various Condition of Fluid Systems)

  • 김윤해;손영준;엄수현;이정주
    • 대한기계학회논문집A
    • /
    • 제27권3호
    • /
    • pp.363-371
    • /
    • 2003
  • This study is mainly concerned with phenomenon of cavitation-erosion on the several materials and corrosive liquids which were applied with vibrator(suggested by ASTM G 32, 20KHz, 50$mu extrm{m}$). The maximum erosion rate by cavitation erosion in both of distilled water and sea water appeared to be proportioned to their hardness and tensile strength. Cavitation weight loss and rate of cast iron in sea water condition were greater(approximately 3 times) than that in distilled water condition, however in case of stainless steel and brass the cavitation weight loss of composite materials were not so different in both of their conditions. Cavitation weight loss of composite materials were shown as below on this test, Duratough DL : Weight loss in sea-water condition were greater (approximately 2.3 times) than it's distilled water condition. The main tendency of cavitation erosion for metals appeared that small damaged holes causing by cavitation erosion was observed with radial pattern. On the other hand, the tendency for composites appeared that small damaged holes were observed randomly.

주조 스테인리스강 CF8M의 43$0^{\circ}C$ 열화거동에 관한 연구(I);열화기구.정적 및 피로강도평가 (A Study on the 43$0^{\circ}C$ Degradation Behavior of Cast Stainless Steel(CF8M)(I);Evaluation of Degradation mechanism, Static and Fatigue Strength)

  • 권재도;박중철;이용선;이우호;박윤원
    • 대한기계학회논문집A
    • /
    • 제24권8호
    • /
    • pp.1910-1916
    • /
    • 2000
  • The five classes of the thermally aged CF8M specimen are prepared using an artificially accelerated aging method. Namely, after the specimens are held for 100, 300, 900, 1800, and 3600hrs at 430$^{\circ}C$ respectively, the specimens are water-cooled to room temperature. The impact energy variations are measures for both the aged and virgin specimens through the Charpy impact tests in addition to the microstructure observation, tensile, hardness and fatigue crack growth tests. From the present investigation the following results are obtained : 1) The difference among the thermally degraded specimens can be distinguished through their microstructures, 2) Hardness and tensile strength are increased to 300hrs, degradation specimen, while elongation and reduction area are decreased to 3600hrs degradation specimen, and impact energy is decreased to 1800hrs degradation specimen, 3) The FCG rates for thermally degraded specimens are larger than that of the virgin specimen.

1000A용 버터플라이 밸브 주요부품의 구조해석 (Structural Analysis of 1000A Butterfly Valve Components)

  • 공유식;김선진;정민화
    • 한국해양공학회지
    • /
    • 제23권1호
    • /
    • pp.140-145
    • /
    • 2009
  • This paper deals with a stability evaluation of a butterfly valve using the body and disc of a valve seat. The experimental results of a strength evaluation are shown using STS316 stainless steel and spheroidal graphite cast iron (GCD450). The disc material was made from GCD450. The results of the strength analysis are as follows: Ultimate tensile strength 485MPa, Yield strength 370 MPa, Young's modulus $1.1{\times}10^5$, and Poisson's ratio v = 0.28. For the results of the disc analysis, the safety factor was about 4. This shows that a design was derived that satisfied the requirements of structural safety. However, some problems, such as the deflection and deformation of the disc, may occur when the sea water has back flow with a high pressure.

재질 열화와 프레팅 피로거동 평가에 관한 연구 (A Study on Material Degradation and Fretting Fatigue Behavior)

  • 권재도;최성종;성상석
    • 대한기계학회:학술대회논문집
    • /
    • 대한기계학회 2001년도 춘계학술대회논문집A
    • /
    • pp.157-162
    • /
    • 2001
  • Fretting is a potential degradation mechanism of structural components and equipments exposed to various environments and loading conditions. The fretting degradation, for example, can be observed in equipments of nuclear, fossil as well as petroleum chemical plants exposed to special environments and loading conditions. It is well known that a cast stainless steel(CF8M) used in a primary reactor coolant(RCS) degrades seriously when that material is exposed to temperature range ken $290^{\circ}C{\sim}390^{\circ}C$ for long period. This degradation can be resulted into a catastrophical failure of components. In the present paper, the characteristics of the fretting fatigue are investigated using the artificially aged CF8M specimen. The specimen of CF8M are prepared by an artificially accelerated aging technique holding 1800hr at $430^{\circ}C$ respectively. Through the investigations, the simple fatigue endurance limit of the virgin specimen is not altered from that obtained from the fatigue tests imposed the fretting fatigue. The similar tests are performed using the degraded specimen. The results are not changed from those of the virgin specimen. The significant effects of fretting fatigue imposed on both virgin and degraded specimen on the fatigue strength are not found.

  • PDF

3차원 스캐너를 이용한 상악 제1유구치 치관의 크기와 형태에 관한 연구 (A MORPHOMETRIC STUDY OF THE MAXILLARY PRIMARY FIRST MOLARS USING THREE-DIMENSIONAL SCANNER)

  • 이종범;김종철;한세현;이상훈
    • 대한소아치과학회지
    • /
    • 제33권4호
    • /
    • pp.643-652
    • /
    • 2006
  • 본 연구의 목적은 상악 제1유구치 치관의 크기와 형태적 특성을 3차원 스캐너를 미용하여 계측하고 국정 금속관과의 크기와 형태학적인 차이를 비교하는 것이다. 3차원 레이저 스캐너(Breuckmann opto Tep-HE100, INUS. Korea)로 스캔한 132aud 어린이들의 상악 제1유구치 경석고 모형을 Rapidform 2004 프로그램(INUS, Korea)을 이용하여 각 치아의 근원심경과 협설경, 교합면-치경부간 거리, 근원심경에 대한 협설경의 비율을 계측하고 평균치를 얻었으며, 남녀 상악 제1유구치의 평균적인 크기와 형태를 얻고 기성 금속관과 비교하여 다음과 같은 결과를 얻었다. 1. 상악 제1유구치 디관의 좌우측 크기에 있어서 유의한 차이를 보이지 않았다(p<0.05). 2. 상악 제1유구치 치관의 남녀간 크기에 있어서 남자의 치관 크기가 유의하게 더 큰 값을 보였고(p<0.05), 치관의 형태에 유의한 치이는 보이지 않았다(p>0.05). 3. 3차원 이미지로 상악 제1유구치를 재구성하여 나타낸 평균적인 남녀 상악 제1유구치의 크기는 3M의 기성 금속관과 비교 시, 남자는 기성 금속관의 4, 5번 사이, 여자는 기성 금속관의 4번과 유사하였고, 일성의 기성 금속관과 비교 시 기성 금속관의 근원심경이 커서 협설경을 기준으로 남자는 5번, 여자는 4번과 유사한 크기를 보였다. 4. 3M의 기성 금속관에 비해 재구성한 평균치의 치관 형태가 근심 설측 우각 부위, 원심 설측 우각 부위에서 더 풍융하였고, 협측 치은 융기의 치경부 1/3부위가 더 풍융한 양상을 보였으며, 남자의 치관보다 더 풍융한 양상을 보였다. 일성의 기성 금속관은 평균치의 치관 형태보다 정사각형의 형태를 나타냈고, 근원심경이 더 긴 양상을 나타냈다.하악 유견치의 치근 흡수의 완료는 하악 제 1 유구치 보다 빨랐으며, 하악 유견치에서 치근 흡수에 소요된 총 기간은 가장 짧았다. 5. 치근 흡수의 속도는 흡수 말기가 초기에 비해 빠른 경향을 나타냈다. 정확한 유치 치근의 흡수시기에 대해 알기 위해서는 정기적이면서 종적인 연구가 필요하리라 생각한다.ture model index(SMI), degree of anisotropy (DA)는 두 군 사이에 유의한 차이를 보이지 않았다(p>0.05). 4. 조직 절편을 관찰한 결과, 부드러운 사료를 먹인 실험군에서 하악 과두의 연골층의 증식 층과 전체 두께가 상당히 감소하였다.항성에 있어 유의한 차이를 보이지 않았다. 8379, 근심면 평균 0.8223, 설면 평균 0.7766, 원심면 평균 0.6781 순으로 나타났다. 4. 치아 우식증 진단율을 비교한 결과 교합면, 협면, 설면에서는 $DIFOTI^{TM}$ 이미지 판독이 가장 우수한 것으로 나타났으며(p<0.05), 근심면과 원심면에서는 방사선 판독이 가장 우수한 것으로 나타났다(p<0.05).는 P=0.009로 나타났다. 임상생징후 변화는 유의성이 없었다. 4. 종양환자의 검사치간의 시기별에 따른 상관관계를 조사한 결과 유의확률이 0.05 이하인 수치들은 Hb과 Albumin, K, Na간, Neutrophil과 Leukocyte간이었고 상관계 수치는 $0.370{\sim}0.442$ 사이로 나타났다. 유의확률 0.01이하로 조사된 수치는 Cholesterol과 ALT간, LDH와 Platelet, Creatinine간, Platelet와 BUN간, Na와 K수치간 이었으며 상관계수는 $0.531{\sim}0.866$사이로 나타났다.

  • PDF