• 제목/요약/키워드: Cascading Method

검색결과 49건 처리시간 0.023초

Cascading 방식을 적용한 펄스발생기의 펄스전압 변성 및 Cascading 비율 특성 (A Study on the Pulse Peak Voltage and Cascading Ratio of Compact Pulse Generator using Cascading Method)

  • 정종한;김희제
    • 대한전기학회논문지:전기물성ㆍ응용부문C
    • /
    • 제50권7호
    • /
    • pp.329-333
    • /
    • 2001
  • The pulsed poser system has been widely used to many applications, such as E/P(Electrostatic Precipitator), DeNox/DeSOx power system, ozon generator, etc. A pulse energy efficiency for load depends on the rising time, peak value, pulse duration and impedance matching, etc. The pulse generator generally required for short pusle duration and high peak value was forced to consider its volume and economy. In this study, developing a compact pulse generator that applied for cascading method to be made of two pulse transformers, we compared cascading voltage with non cascading one by applying the pulse energy to load. Adopting cascading technique to pulse transformer, we found that average cascading voltage was about 60[%] of theoretical value. Maximum cascading ratio was calculated at 60 times compared with non cascading voltage.

  • PDF

Cascading Chebyshev filter를 이용한 리플 제거에 관한 연구 (A Study on the ripple cancellation using two cascading Chebyshev filters)

  • 신승식
    • 전기학회논문지
    • /
    • 제61권11호
    • /
    • pp.1700-1705
    • /
    • 2012
  • This study is focusing on ripple elimination in the band pass filter. There are generally two design methods in IIR filter design, which are a direct method and an indirect one. The indirect design method that designs the digital IIR LPF using the prototype analog LPF is applied to this study. A Butterworth filter and a Chebyshev filter are the typical prototype analog LPFs. This study shows characteristics of the digital IIR LPFs that are transformed from the prototype analog LPFs. The designed Butterworth and Chebyshev IIR LPFs are also designed as the band pass filters by frequency transformation in order to compare with the proposed cascading Chebyshev BPFs. This study shows frequency characteristics between the transformed IIR BPFs and the proposed cascading Chebyshev BPFs as well. The proposed cascading Chebyshev BPF is designed by cascading the different orders of Chebyshev BPFs. The aspect of the cascading filter is offsetting the ripples to descend them while the pass band ripples of the Chebyshev filter are ascending and vice versa. The designed cascading Chebyshev filter shows the flatness and the sharpness, which represent the advantages of Butterworth filter in the pass band and of Chebyshev filter in the transition band respectively. This result verifies the validity of the designed filter.

안정한 종속 BPF의 성능에 관한 연구 (A Study on the Performance of the Stable Cascading BPF)

  • 김정환;신승식
    • 전기학회논문지
    • /
    • 제62권12호
    • /
    • pp.1758-1763
    • /
    • 2013
  • This paper is a study on the performance of the stable cascading BPF. There are generally two methods of designing IIR filter, which are a direct method and an indirect one. The indirect design method that is transformed into the BPF by frequency transformation using the prototype analog LPF which is satisfied for designing specifications is applied to this study. As typical prototype analog LPFs, there are the Butterworth filter, the Chebyshev filter and the elliptic filter. In this study, we connect the frequency transformed BPFs (to the cascade form) which have been converted from the stable Butterworth filter and Chebyshev filter. Three classified simulations are conducted in this study, which are the cascading Butterworth BPF Only, the cascading Chebyshev BPF Only and the cascading Butterworth and Chebyshev BPFs. As a result of the simulation, this study shows that a ripple size of the cascading Chebyshev BPF Only is about 1[dB] smaller than that of the cascading Butterworth and Chebyshev BPFs and also the skirt characteristic of the cascading Chebyshev BPF in the transition band is most outstanding and has the widest bandwidth. The result of performance comparison shows the validity of specifications required in the workplace.

종속고장을 고려한 전력시스템의 신뢰도 평가 (Reliability Analysis of Power System with Dependent Failure)

  • 손현일;권기량;김진오
    • 조명전기설비학회논문지
    • /
    • 제25권9호
    • /
    • pp.62-68
    • /
    • 2011
  • Power system needs to sustain high reliability due to its complexity and security. The reliability prediction method is usually based on independent failure. However, in practice, the Common Cause Failures(CCF) and Cascading failure occur to the facilities in power system as well as independent failures in many cases. The CCF and Cascading failure turn out the system collapse seriously in a wide range. Therefore to improve the reliability of the power system practically, it is required that the analysis is conducted by using the CCF and Cascading failure. This paper describes the CCF and Cascading failure modeling combined with independent failure. The incorporated model of independent failure, CCF and cascading failure is proposed and analyzed, and it is applied to the distribution power system in order to examine this method.

소형트랜스의 Cascading 방식을 적용한 임펄스 출력특성 (The Impulse Output Characteristics using Cascading Method of Compact Transformer)

  • 정종한;김휘영;홍정환;박구렬;김희제;조정수
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2000년도 하계학술대회 논문집 C
    • /
    • pp.1865-1867
    • /
    • 2000
  • The pulse power system has been widely used to many applications. such as E/P(Electrostatic Precipitator), DeNOx/DeSOx power system, ozon generator. etc. A pulse energy efficiency for load depend on the rising time, peak value, pulse duration, impedance matching. etc. The pulse generator generally required for short pulse duration, high peak value was forced to consider its size and economy. In this study, developing a compact pulse generator that applied for Cascading method to be made of two pulse transformer, we compared cascading voltage with no cascading one by applying the pulse energy to load.

  • PDF

The Study on the Electrical Characteristics of the Pulse Generator adopted Cascading Technique

  • Joung, Jong-Han;Kim, Moon-Hwan
    • Journal of Power Electronics
    • /
    • 제4권2호
    • /
    • pp.112-116
    • /
    • 2004
  • The pulsed power systems have been widely used many other countries and their new applications have been developed by many researchers, such as E/P(Electrostatic Precipitator) to remove the industrial dust, DeNOx/DeSOx power systems, ozone generators and power sources of the laser beam, etc. In this paper, we studied the cascading technique as a new technology consisted of two pulse transformers and obtained their experimental data and results. To obtain the high pulsed voltage adopted cascading technique, we designed our compact pulse generator and tested by adjusting the value of the load resistors to obtain high pulsed voltage with steep rising time and duration time. We explained their experimental results that obtained by adopting cascading technique. Also, we compared theoretical value with measured value obtained by using the cascading method.

4-Bit 카운터 74LS163의 연결방법에 대한 분석 (Analysis of the Method of Cascading 74LS163 4-Bit Binary Counters)

  • 유준복;정태상
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2000년도 추계학술대회 논문집 학회본부 D
    • /
    • pp.794-796
    • /
    • 2000
  • This paper analyzes the method of cascading 74LS163 4-Bit Binary Counters. The 74LS163 4-Bit Binary Counter has synchronous LD. CLR functions and especially ENT, ENP, RCO to cascade some chips in order to count more 4bit binary number. The maximum operating frequency may vary according to the method of cascading. The Data sheet from Texas Instruments introduces two methods, The Ripple Carry Mode Circuit and The Carry Look Ahead Circuit, and shows that The Carry Look Ahead Circuit is more efficient than the other. However, there are only little information for user to understand and apply this to other circuits. Thus, we not only analyzed the two methods but also compared with each other in the point of performance.

  • PDF

Microwave Studio와 전달행렬 캐스케이딩을 이용한 케이블 누화 시뮬레이션 방법과 직선구간을 포함하는 Twisted Wire Pairs(TWP) 누화 분석 (A Cable Crosstalk Simulation method using Microwave Studio & T-matrix Cascading and Crosstalk Analysis of Twisted Wire Pairs(TWP) including Straight Sections)

  • 민태홍
    • 한국시뮬레이션학회논문지
    • /
    • 제26권1호
    • /
    • pp.47-54
    • /
    • 2017
  • 본 논문에서는 3차원 전자파 해석 툴인 Microwave Studio(MWS)와 Matlab을 이용한 케이블 누화 시뮬레이션 방법에 대해 소개하고 이를 이용하여 항공 및 군용에 사용되는 Twisted Wire Pair(TWP)로 구성된 케이블 조립체의 누화특성을 분석한다. TWP는 한 방향으로 길게 꼬여있는 구조로 3차원 전자파 해석 툴만을 이용하여 분석 시 Mesh의 기하급수적인 증가로 인해 메모리가 많이 필요해 해석이 불가능한 경우가 발생한다. 전달행렬(Transmission Matrix)은 주기적인 구조를 해석하는데 효율적이며, 단위 구조 결과를 캐스케이딩(Cascading)하여 전체 구조의 해석을 빠른 시간에 할 수 있어 구조가 반복적인 케이블 시뮬레이션에 적합하다. 본 논문에서는 케이블 누화 시뮬레이션 방법을 이용하여 케이블 조립체를 직선구간을 포함된 TWP로 모델링 하여 누화 특성을 분석하였다.

도로자산관리를 위한 서비스수준 기반 균형성과표 평가체계 개발 (Development of an Evaluation System of a LOS-based Balanced Scorecard for Road Infrastructure Asset Management)

  • 한대석;유인균;이수형
    • 한국도로학회논문집
    • /
    • 제17권3호
    • /
    • pp.13-25
    • /
    • 2015
  • PURPOSES : This paper aims at the implementation of a balanced scorecard that can be widely applied to modern business management for use in the public road management sector. METHODS : This study applied the newly developed LOS-based balanced scorecard system instead of a traditional Key Performance Index (KPI) for better decision making in asset management planning. As an evaluation technique, a" hierarchical alignment and cascading method" is also suggested. Finally, the suggested system has been empirically applied to a regional government. RESULTS : To provide stable and sustainable road services, the balanced scorecard informs the regional government of needed improvements in its asset management plans regarding budget optimization, structural management, the development of inner-business processes, and human resources. CONCLUSIONS : An LOS-based balanced scorecard for managing road services and organizations in a quantitative manner has been successfully developed and tested through a field study. The developed scorecard is a timely topic and a useful analytical tool for coping with the new phases of an aging infrastructure, tighter budgets, and demand for greater public accountability.

정규화된 고차 inverse Chebyshev함수를 이용한 능동 필터 설계 (An Active filter Design using Normalized High Order Inverse Chebyshev Functions)

  • 신홍규;김동용
    • 한국통신학회논문지
    • /
    • 제13권4호
    • /
    • pp.322-331
    • /
    • 1988
  • 본 논문에서는 고차 inverse Chebyshev 함수를 이용하여 능동 RC필터로 설계할 때 최대 동적범위를 갖고, 감도가 낮은 종속연결법으로 실현하는 방법을 제시하였다. 이때, 최대 동적범위를 만족시키도록 평탄행렬에 의한 최적 극점-영점 결합과 종속 연결순서 및 이득 분배에 대한 알고리즘을 제시하였으며, 능동 RC 회로의 단점인 감도 문제를 향상시키기 위하여 부 궤환을 갖는 2차 블록과 1차 블록을 설계하였다. 제시된 설계 방법을 이용하여 규준화된 7차 inverse Chebyshev함수의 능동 RC저역통과 필터를 설계한 결과 주어진 설계 명세조건과 일치함을 보였다.

  • PDF