• Title/Summary/Keyword: Cartridge

Search Result 499, Processing Time 0.032 seconds

Development and Test of Gas Turbine Intake Air Filter Media (가스터빈 유입공기 정화용 에어 필터 여재 국산화 개발 기초 성능실험)

  • 박현설;박석주;김상도;최호경;임정환;박영옥
    • Proceedings of the Korea Air Pollution Research Association Conference
    • /
    • 2000.11a
    • /
    • pp.261-262
    • /
    • 2000
  • 항공기나 발전용 가스터빈(gas turbine) 및 대용량 압축기(compressor) 등과 같이 흡입공기의 유량이 매우 클 경우, 유입되는 공기 내부에 함유된 입자상 오염물질은 터빈의 기계적 성능에 큰 장애를 일으킬 수 있다(Klink and Schroth, 1996, Schroth, 1993). 이러한 입자상 오염물질을 효과적으로 제어하기 위해서는 처리기체의 유입구 부분에 대형 공기 정화용 여과시스템이 요구되며, 일반적으로 카트리지형 에어 필터(cartridge air filter)나 포켓형(pocket), 카세트형(cassette) 에어 필터가 적용 현장의 조건에 따라 사용된다. (중략)

  • PDF

A Study on the Effect of Storing Temperature and Humidity upon the Self Life of Propellant KM30Al (추진제 KM30Al의 저장 온도/습도와 저장수명과 관계 고찰)

  • Cho, Ki-Hong
    • Journal of the Korea Institute of Military Science and Technology
    • /
    • v.9 no.1 s.24
    • /
    • pp.13-23
    • /
    • 2006
  • A propellant mainly consisting of nitric ester including nitrocellulose and nitroglycerine is characteristic of being decomposed naturally. And this phenomenon is known as being affected mostly by its storing temperature and humidity. In this research, the effect of storing temperature and humidity on self life has been studied by measuring the contained quantity of residual stabilizer of propellant KM30Al, which are parts of 155MM propelling charge K676 and K677; the method for the measurement is acceleration aging test, and decomposition reaction equation, Eyring Equation and Berthlot Equation were used for the calculation. As result of this study, it was found that the storing temperature influenced seven times as large as the storing humidity upon the self life of the propellant KM30Al, Furthermore, especially in the high temperature region, the storing temperature had a dominant effect on the self life.

Ashpalt 2 Component Adhesive Leakage Repair Sealant Evaluation (아스팔트 2액형 점착재의 누수보수 평가에 관한 연구)

  • Cho, Il-Kyu;Kim, Keun-Hur;Oh, Sang-Keun
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2017.05a
    • /
    • pp.140-141
    • /
    • 2017
  • This study is based on the evaluation of a single component injection type adhesive repair material and a new 2 component type used in leakage of underground concrete structures. The studies showed that based on different mix ratio of the 2 component type adhesive sealant comprised of an asphalt main and latex mixture agent the viscosity of the material compound differed significantly. Based on a permeability testing, injection and economic efficiency, and performance, the appropriate ratio was determined to be 6:1 and was proceeded to the KS F 4935 evaluation method. The 2 component type adhesive sealant uses a static mixer and a cartridge type container for the injection procedure and was able to satisfy the evaluation criteria outlined in the KS F 4935 standard.

  • PDF

Occurrence of aflatoxin $M_1$ in milk determined by HPLC with derivatization method in Korea (1999-2000)

  • Kang, Hwan Goo;Cho, Joon Hyoung
    • Korean Journal of Veterinary Research
    • /
    • v.47 no.4
    • /
    • pp.389-393
    • /
    • 2007
  • In this study, the levels of aflatoxin $M_1$ ($AFM_1$) in milk were determined by HPLC with derivatization method. Milk samples were purified using $C_{18}$ disposable cartridge followed by derivatization with trifluoroacetic acid and analysed using HPLC with fluorescence detection. The recoveries of AFM1 from milk samples added $AFM_1$ at a level of 0.025~0.1 ng/ml were 94.7~98.0% with detection limit of 0.009 ng/ml. The amounts of $AFM_1$ were determined below 0.05 ng/ml for all tested samples of commercial milk collected in 1999 and 2000.

Sorbent Thermal Desorption/Gas Chromatography/Mass Selective Detection Method for Determination of Gaseous Polycyclic Aromatic Hydrocarbons in Indoor Air

  • Dai, Shugui;Zhang, Lin;Zhu, Tan
    • Analytical Science and Technology
    • /
    • v.8 no.4
    • /
    • pp.753-758
    • /
    • 1995
  • Thermal desorption/gas chromatography/mass selective detection method using Tenax cartridges for the determination of gaseous polycyclic aromatic hydrocarbons(PAH) is described. Glass fiber filter can collect only PAH in particulate. Gaseous PAH may penetrate the filter. Glass cartridge packed Tenax-GC was uses fur adsorption of gaseous PAH. The air of inhalation zone was collected fur 2-10 hours. Cartridges were thermally desorbed in the reverse direction to sample flow. The desorption conditions were as follows; desorption temperature; $300^{\circ}C$; desorption time; 20min; column head pressure; 30psi; inlet split vent; closed during desorption.

  • PDF

Simultaneous determination of bisphenol A, chlorophenols and alkylphenols by solid-phase extraction and HPLC

  • Lee, Taejoon;Park, Keun-Young;Pyo, Dongjin
    • Analytical Science and Technology
    • /
    • v.30 no.1
    • /
    • pp.20-25
    • /
    • 2017
  • An analytical method for determining potential endocrine disruptors (bisphenol A, 2-chlorophenol, 2,4-dichlorophenol, 2,4,6-trichlorophenol, pentachlorophenol, p-t-butylphenol, p-pentylphenol, p-hexylphenol, p-t-octylphenol, p-heptylphenol, nonylphenol) by solid-phase extraction (SPE) and High Perfomance Liquid Chromatography(HPLC) equipped with fluorescence and variable wavelength detector has been developed. The SPE process for sample concentration was performed on a commercially available Oasis HLB cartridge packed with polymeric sorbents. The effect of elution solvent and elution volume on the recoveries of the analytes were investigated with HPLC. Average recovery of >85% was achieved with 60mg sorbents using 5mL of methanol as elution solvent. Phenolic compounds in canned drinks, beverages and water samples were surveyed by this proposed method.

Decoupling effects on the level of blasting vibration (발파진동의 크기에 미피는 기커플링 효과의 연구(화약))

  • 김당수
    • Explosives and Blasting
    • /
    • v.15 no.3
    • /
    • pp.20-32
    • /
    • 1997
  • The pressure-time profile of the explosion gases can be controlled fot the use of cartridge explosives with two techniques Known as Decoupling and Spacing the charges. Decoupling consists in leaving and empty space between the explosive column and wall of the blast hole. Four different decoupling index, 1.4, 1.8, 2.34, 3.0 are selected in this field study. The level of ground vibrations with each decoupling index are measured and the empirical particle vibrations with each decoupling index are measured and the empirical particle velocity equation from these data was obtained. The condition of new cracks at blast hole are also examined. As the decoupling index in increased, the level of the blast vibration is decreased,. But the cracks in rock masses are efficiently formed to remove the broken rock. The vibration constant associated with a given site $K=1564.5(D.I)^{-1.3233}$ in terms of D.I(decopling index).

  • PDF

Development of a Flow Injection Analysis Technique for On-line Monitoring of Xylitol Concentrations (자일리톨 농도의 온라인 모니터링을 위한 흐름주입분석기술 개발)

  • 이종일
    • KSBB Journal
    • /
    • v.17 no.4
    • /
    • pp.339-344
    • /
    • 2002
  • Flow injection analysis technique for monitoring of xylitol concentrations in biological processes has been developed using xylitol oxidase (XYO) immobilized on VA-Epoxy Biosynth carrier. The immobilized XYO cartridge has been integrated into a FIA system with an oxygen electrode and systematically investigated with regards to the factors which can affect the activity of the immobilized XYO, such as pH, temperature, salt concentration etc. The activity of the immobilized XYO increased with the temperature ($19.0 - 29.0^{circ}C$) and sample injection volume ($75-250\muL$) and molarity of potassium phosphate buffer (0.1-1 M), but it reached the highest value at pH 8.5. The XYO-FIA system has been also applied for on-line monitoring of xylitol concentrations in a reactor and showed good operational stability and agreement with off-line data measured with HPLC.

Study on Boiling Heat Transfer of FC-77 in Spray Cooling (FC-77의 분무냉각 비등열전달 특성에 관한 연구)

  • Kim, Yeung-Chan
    • Journal of ILASS-Korea
    • /
    • v.12 no.4
    • /
    • pp.179-184
    • /
    • 2007
  • The boiling heat transfer was experimentally investigated for the FC-77 sprays impacting a square heated test surface in a downward direction. Full cone spray nozzles were employed for the spray cooling experiment, and experiments were made under the test conditions of $Q=3.32{\times}10^{-6}{\sim}2.30{\times}10^{-5}\;m^3/s$, ${\Delta}T_{sub}=20{\sim}70^{\circ}C$. Also, heat transfer measurements were made using the copper block of $10{\times}10\;mm^2$ test area heated by nine cartridge heater. From the experimental results, correlation between the Nusselt number and Reynolds number based on droplet-flow-rate was developed. The correlation shows good predictions with ${\pm}30%$ error for FC-77.

  • PDF

Experimental Analysis of Droplet Formation Process for Inkjet Printhead (잉크젯 헤드를 이용한 액적 토출 현상의 실험적 분석)

  • Jo, Y.M.;Park, S.J.
    • Journal of ILASS-Korea
    • /
    • v.15 no.4
    • /
    • pp.163-169
    • /
    • 2010
  • Jetting stability is the most important factors in inkjet printing because printing quality is totally determined by shape of the droplets on the substrate. In order to acquire stable jet, viscosity and dynamic behavior of the ink must be considered. In addition, waveform to drive the inkjet printhead is also to be controlled. In this study, the driving waveform composed of rising time, dwell time and falling time is optimized to obtain a stable jetting using drop watcher system. Also, effect of ink viscosity on jetting is experimentally investigated by changing the temperature of ink cartridge. As a result, jetted drop having uniform velocity is acquired.