Comparisons of Image Quality and Entrance Surface Doses according to Care Dose 4D + Care kV in Chest CT (Chest CT에서 Care Dose 4D+Care kV에 따른 화질과 입사표면선량 비교)

  • Kang, Eun-Bo
    • Journal of the Korean Society of Radiology
    • /
    • v.16 no.1
    • /
    • pp.45-51
    • /
    • 2022
  • This study compared DLP values along with phantom entrance surface doses and the image quality of chest CT scans made using a Care Dose 4D+Care kV System, scans that are made using only the Care Dose 4D function, and scans that are made with changes made by applying 80 kVp, 100 kVp, 120 kVp, and 140 kVp to the Care Dose 4D and tube voltage to search for methods to maintain the highest image quality with minimal patient doses. It was shown that DLP values decreased 6.727% when scans were taken with Chest Care Dose 4D + Care kV semi 100 and 6.481% when scans were taken with Chest Care Dose 4D + Care kV. With Chest Non as a standard, skin surface doses decreased 16.519% when scans were taken with Chest Care Dose 4D + Care kV semi 100 and 15.705% when scans were taken with Chest Care Dose 4D + Care kV. With comparisons of image quality, when comparisons were made with Chest Non, comparisons made of SNR values and CNR values in all scanning conditions including Care Dose 4D + Care kV showed that there were no significant differences at P>0.05. Imaging using Chest Care Dose 4D + Care kV in chest CT showed that exposure doses decreased similarly to result values gained from the best conditions through manual adjustments of kV and mAS, and there were no significant differences in image SNR and CNR. If the Chest Care Dose 4D + Care kV function is used, image quality is maintained and patient exposure to radiation can be reduced.

Dose Reduction and Image Quality Assessment of the CareDose 4D Technique on Abdomen Liver Computed Tomography (복부 간 CT 검사에서 CareDose 4D 사용에 따른 선량 감소 및 화질 평가)

  • Seok, Jong-Min;Jeon, Woo-Jin;Park, Young-Joon;Lee, Jin
    • Journal of the Korean Society of Radiology
    • /
    • v.11 no.3
    • /
    • pp.109-115
    • /
    • 2017
  • The purpose of this study was to evaluate the clinical efficacy of 128 MDCT (multi-detector computed tomography) for reducing the CareDose 4D dose and comparing the image quality with the fixed tube current technique. For this purpose, we conducted the phantom and clinical studies to evaluate the exposure dose and image of the subject before and after applying the CareDose 4D system in abdominal examination using 128 MDCT. In the phantom study, ROI (Region of interest) was located at the center, 3, 6, 9, 12 o'clock, into two groups: group A without CareDose 4D and Group B applied were measured. In the clinical study, ROI was located at the liver 8 segments, divided into two groups too. The measured items were CT number, noise, and dose length product (DLP) dose. The result of CTDIvol (CT Dose Index volume) measurements in phantom and clinical studies were lower than those before CareDose 4D application, and dose and effective dose were also measured lower (p<.05). There was no difference in CT number before and after application (p>.05). In conclusion, using CareDose 4D, we can obtain optimal image information without deteriorating image quality while reducing patient dose.

Comparison of Noise and Doses of Low Dose and High Resolution Chest CT for Automatic Tube Current Modulation and Fixed Tube Current Technique using Glass Dosimetry (유리선량계를 이용한 관전류자동조절기법과 고정관전류기법에서 저선량 및 고해상 흉부CT의 노이즈 및 선량 비교)

  • Park, Tae Seok;Han, Jun Hee;Jo, Seung Yeon;Lee, Eun Lim;Jo, Kyu Won;Kweon, Dae Cheol
    • Journal of Radiation Industry
    • /
    • v.11 no.3
    • /
    • pp.131-137
    • /
    • 2017
  • To compare the radiation dose and image noise of low dose computed tomography (CT) and high resolution CT using the fixed tube current technique and automatic tube current modulation (CARE Dose 4D). Chest CT and human anthropomorphic phantom were used the RPL (radiophotoluminescence) dosimeters. For image evaluation, standard deviation of mean CT attenuation coefficient and CT attenuation coefficient was measured using ROI analysis function. The effective dose was calculated using CTDIvol and DLP. CARE Dose 4D was reduced by 74.7% and HRCT by 64.4% compared to the fixed tube current technique in low dose CT of chest phantom. In CTDIvol and DLP, the dose of CARE Dose 4D was reduced by fixed tube current technique. For effective dose, CARE Dose 4D was reduced by 47% and HRCT by 46.9% compared to the fixed tube current method, and the dose of CARE Dose 4D was significantly different (p<.05). Noise in the image was higher than that in the fixed tube current technique. Noise difference in the image of CARE Dose 4D in low dose CT was significant (p<.05). The low radiation dose and the noise difference of the CARE Dose 4D were compared with the fixed tube current technique in low dose CT and HRCT using chest phantom. The radiation doses using CARE Dose 4D were in accordance with the national and international dose standards. CARE Dose 4D should be applied to low dose CT and HRCT for clinical examination.

A Study on Various Automatic Exposure Control System in Multi-Detector Computed Tomography by Using Human Phantom (인체 모형을 이용한 다중 검출기 컴퓨터단층촬영기기의 다양한 자동노출제어 시스템에 대한 연구)

  • Kim, Yong-Ok;Seoung, Youl-Hun
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.13 no.4
    • /
    • pp.1714-1720
    • /
    • 2012
  • The purpose of the study was to evaluation of the radiation dose reduction and the possibility of the maintainability of the adequate image quality using various automatic exposure control (AEC) systems in multi-detector computed tomography (MDCT). We used three AEC systems for the study: General Electric Healthcare (Auto-mA 3D), Philips Medical systems (DoseRight) and Siemens Medical Solutions (Care Dose 4D). The general scanning protocol was created for the each examination with the same scanning parameters as many as possible. In the various AEC systems, the evaluation of reduced-dose was evaluated by comparing to fixed mAs with using human phantom. The image quality of the phantom was evaluated with measuring the image noise (standard deviation) by insert regions of interests. Finally, when we applied to AEC for three manufacturers, the radiation dose reduction decreased each 35.3% in the Auto-mA 3D, 58.2% in the DoseRight, and 48.6% in the Care Dose 4D. And, there was not statistical significant difference among the image quality in the Strong/Weak of the Care Dose 4D(P=.269). This applies to variety of the AEC systems which will be very useful to reduce the dose and to maintain the high quality.

Analysis of Dose Reduction Rate with Dose Modulation Technic Depending on BMI (PET/CT검사에서 Dose Modulation Technic 적용시 BMI에 따른 선량 감소율 분석)

  • Kim, Jung Wook;Park, Se Yun;Jo, Young Jun;Park, Jong Yeop
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.16 no.2
    • /
    • pp.25-28
    • /
    • 2012
  • Purpose : It is important to reduce radiation dose associated with computed tomography (CT) scanning to as low as reasonably achievable (ALARA). With Dose Modulation Technic, user select a desired image quality and the system adapts tube current to obtain the desired image quality with greater radiation dose efficiency. In this paper, we presents a comprehensive description of fundamentals, clinical applications and radiation dose benefits of Dose Modulation Technic depending on Body Mass Index(BMI). Materials and Methods : In this study, 149 patients were examined(The mean age : $58{\pm}12.4$ years old). Biograph True Point 40 (Siemens, USA) and Gemini TF 64 (Philips. Cleveland) were used for equipment. When we used Care Dose 4D (Siemens, USA) and D-dom (Philips, Cleveland), we measured dose reduction and Computed Tomography Dose Index (CTDI) depending on BMI. Then we analyze data using SPSS Ver.18. Results : When we used Care Dose 4D, p-value is considered statistically significant by groups with the result that we compared Care Dose 4D with D-dom. On the other hand, p-value isn't considered statistically significant by groups using D-dom. Conclusion : Dose modulation based on the projection angle didn't affect degree of obesity. And When using Care Dose 4D, dose reduction rate in the normal patients were higher than the obese. In this study, there are errors on somato type. So I think more research have to be done. Then application of Dose Modulation technic can help in maintaining acceptable image quality while reducing radiation dose by 20-60% in most instances.

  • PDF

Radiation Dose Comparison according to Different Organ Characteristics at Same Scan Parameters Using CareDose 4D: An Adult and Pediatric Phantom Evaluation (CareDose 4D 사용 시 동일한 스캔조건에서 조직기반설정을 다르게 적용함에 따른 선량 비교: 성인과 소아팬텀 연구)

  • Kong, Hyo-Geum;Lee, Ki-Baek
    • Journal of radiological science and technology
    • /
    • v.42 no.4
    • /
    • pp.271-277
    • /
    • 2019
  • CareDose 4D which is the Siemens's Automatic Exposure Control (AEC) can adjust the level of radiation dose distribution which is based on organ characteristic unlike other manufacturer's AEC. Currently, a wide scan range containing different organs is sometimes examined at once (defined as one scan). The purpose of this study was to figure out which organ characteristic option is suitable when one scan method is utilized. Two types of anthropomorphic phantoms were scanned in the same range which were from frontal bone to carina level according to three different organ characteristics such as Thorax, Abdomen, and Neck. All scans and image reconstruction parameters were equally applied and radiation dose were compared. Radiation dose with Thorax organ characteristic was lower than that with Neck. Also, that with Abdomen oran characteristic was lower than Thorax. There were significant differences in radiation dose according to different organ characteristics at the same parameters (P<0.05). Usage of Neck organ characteristic had a result of the highest radiation dose to all phantom. On the other hand, utilization of Abdomen organ characteristic showed the lowest radiation dose. As a result, it is desirable to set appropriate organ characteristic according to examined body part when you checkup patients. Also, when you implement one scan method, selection of Abdomen-based organ characteristic has reduced more radiation dose compared with two different organ characteristic.

A Follow-up Study on the Personal Noise Exposed Dose and Hearing Loss (개인 소음폭로량과 청력손실에 관한 추적조사)

  • Kim, Won-Sool;Hong, Young-Seoub;Kim, Yang-Seak;Lee, Sang-Ju;Park, Kyung-Il;Jung, Kap-Yull;Kim, Joon-Youn
    • Journal of Preventive Medicine and Public Health
    • /
    • v.27 no.2 s.46
    • /
    • pp.286-298
    • /
    • 1994
  • For the purpose of presenting the basic data for the establishment of control measures on the long-term noise exposed workers, this study was carried out on the relationship between personal noise exposed dose and hearing loss on the 67 male workers whose hearing threshold had exceeded 40 dB in 4,000 Hz, from 1990 to 1992. Conclusively, the level of hearing loss was significantly related to personal noise exposed dose in follow-up period. We considered that personal noise exposed dose which was measured by the personal noise dosemeter was more efficient rather than the noise level of workplace for the evaluating the long-term change of hearing acuity. And although in the case of not-diagnosed as noise induced hearing loss. it was suspected that the active control programs such as improvement of noisy environment or early transfer to proper workplace were needed on the workers who exposed with over 90 dB in personal noise exposed dose.

  • PDF

Improved postoperative recovery profile in pediatric oral rehabilitation with low-dose dexmedetomidine as an opioid substitute for general anesthesia: a randomized double-blind clinical trial

  • Naveen, Naik B;Jaiswal, Manoj Kumar;Ganesh, Venkata;Singh, Ajay;Meena, Shyam Charan;Amburu, Vamsidhar;Soni, Shiv Lal
    • Journal of Dental Anesthesia and Pain Medicine
    • /
    • v.22 no.5
    • /
    • pp.357-367
    • /
    • 2022
  • Background: Low-dose dexmedetomidine may be a suitable alternative to opioids for pediatric ambulatory procedures under general anesthesia (GA). However, the recovery profile remains unclear. Herein, we aimed to evaluate the effects of low-dose dexmedetomidine on the recovery profile of children. Methods: Seventy-two children undergoing ambulatory oral rehabilitation under GA were randomly and equally distributed into two groups (D and F). Group D received an infusion of dexmedetomidine 0.25 ㎍/kg for 4 min for induction, followed by maintenance of 0.4 ㎍/kg/h. Group F received an infusion of fentanyl 1 ㎍/kg over 4 min for induction, followed by maintenance at 1 ㎍/kg/h. The primary outcome was the extubation time. The secondary outcomes were awakening time, end-tidal sevoflurane (ET-Sevo) requirement, change in hemodynamic parameters, Richmond Agitation-Sedation Scale (RASS), Children's Hospital of Eastern Ontario pain scale (CHEOPS) score, length of PACU stay, and incidence of adverse events. Results: Statistically significant differences were observed in the recovery profile between the groups: the median time for extubation was 3.65 (3.44-6.2) vs. 6.25 (4.21-7) minutes in groups D vs. F (P=0.001), respectively, while the corresponding awakening times were 19 (18.75-21) and 22.5 (22-24) minutes, respectively (P < 0.001). The mean ET-Sevo was low in group D (1.1 vs. 1.2; P < 0.001). The heart rate was significantly low across all time points in group D, without resulting in bradycardia. The median RASS and CHEOPS scores were also significantly lower in group D. No significant differences were observed in the mean arterial pressure, incidence of adverse events, or length of PACU stay. Conclusion: Low-dose dexmedetomidine was more effective than fentanyl as an opioid substitute at providing a better recovery profile in pediatric ambulatory oral rehabilitation under GA. Dexmedetomidine also significantly reduced sevoflurane consumption without causing adverse events or prolonging hospital stay.

Distribution and Management of Spatial Dose Rate in Neuro Angio Room (두개부 혈관조영실에서 공간산란선량의 분포와 관리)

  • Lee, Mi-Hwa;Jung, Hong-Ryang;Lim, Cheong-Hwan;Hong, Dong-Hee;Kim, Ki-Jeong;Kim, Sang-Hyun
    • Journal of Digital Convergence
    • /
    • v.12 no.4
    • /
    • pp.427-435
    • /
    • 2014
  • This study is performed in the intervention unit, during interventional procedures and in accordance with the direction and distance during the exposure indoor space is to measure the dose. I was classified at an angle of $45^{\circ}$ counterclockwise from the phantom. Seven(A, B, C, D, E, F, G) were classified as direction. Length was measured from the center of the phantom. Each direction 50cm, 100cm, 150cm, 200cm were classified. I was analyzed by measuring of frontal, lateral, Bi-plan fluoroscopic Spatial dose rate in all 28 points. Measured dose was the highest at 50cm and over 200cm, dose was rapidly decreasing as increased distance. Dose was different more than nine times depending on the distance and direction, Installation of shielding wall can reduce exposure about 84.52% to 93.54%.