• Title/Summary/Keyword: Carbon reduction performance

Search Result 333, Processing Time 0.029 seconds

Improvement of Thermal Efficiency using Atkinson Cycle in a High-Compression Ratio, Spark-Ignition, Natural Gas Engine for Power Generation (고압축비 전기점화 천연가스 발전용 엔진에서 앳킨슨 사이클 적용을 통한 열효율 향상)

  • Junsun Lee;Hyunwook Park;Seungmook Oh;Changup Kim;Yonggyu Lee;Kernyong Kang
    • Journal of ILASS-Korea
    • /
    • v.28 no.2
    • /
    • pp.55-61
    • /
    • 2023
  • Natural gas is a high-octane fuel that is effective in controlling knocking combustion. In addition, as a low-carbon fuel with a high hydrogen-carbon ratio, it emits less carbon dioxide and almost no particulate matter compared to conventional fossil fuels. Stoichiometric combustion engines equipped with a three-way catalyst are useful in various fields such as transportation and power generation because of their excellent exhaust emission reduction performance. However, stoichiometric combustion engines have a disadvantage of lower thermal efficiency compared to lean combustion engines. In this study, a combination of high compression ratio and Atkinson cycle was implemented in a 11 liter, 6-cylinder, spark-ignition engine to improve the thermal efficiency of the stoichiometric engine. As a result, pumping and friction losses were reduced and the operating range was extended with optimized Atkinson camshaft. Based on the exhaust gas limit temperature of 730℃, the maximum load and thermal efficiency were improved to BMEP 0.66 MPa and BTE 35.7% respectively.

Fabrication and characterization of polymer-based carbon nanomaterial composites for thermal conductive adhesive application (열전도성 점착제 응용을 위한 고분자 기반 탄소나노소재 복합체 제조 및 특성 평가)

  • Lee, Byeong-Joo;Jo, Sung-Il;Yoon, Eun-Hye;Lee, Ae-Ri;Lee, Woo-Young;Heo, Sung-Gyu;Hwang, Jae-Sung;Jeong, Goo-Hwan
    • Journal of the Korean institute of surface engineering
    • /
    • v.53 no.4
    • /
    • pp.160-168
    • /
    • 2020
  • A polymer-based carbon nanomaterial composite was fabricated and characterized for the application of a thermal conductive adhesive. Low-dimensional carbon nanomaterials with excellent thermal conductivity such as carbon nanotube (CNT) and graphene were selected as a filler in the composite. Thermal, electrical and adhesive properties of the composite were investigated with respect to the morphology and content of the low-dimensional carbon nanomaterials. As a result, the composite-based adhesive fabricated by the loading of surface-treated MWCNTs of 0.4 wt% showed uniform dispersion, moderate adhesion and effective heat dissipation properties. Finally, it was confirmed through the thermal image analysis of LED module that the temperature reduction of 10℃ was achieved using the fabricated composite adhesive with MWCNT-6A. Expecially, heat dissipation performance of the optimized composite adhesive was evident at the hot spot in the module compared to other samples mixed with graphene or different MWCNT loading ratios.

Electrical resistivity characteristics for cement specimens with TiO2 according to activated carbon content (활성탄 함유량에 따른 광촉매(TiO2) 시멘트 시편의 전기비저항 특성)

  • Kong, Tae-Hyun;Lee, Jong-Won;Ye, Ji-Hun;Ahn, Jaehun;Oh, Tae-Min
    • Journal of Korean Tunnelling and Underground Space Association
    • /
    • v.22 no.5
    • /
    • pp.591-610
    • /
    • 2020
  • Concrete with activated carbon and titanium dioxide (TiO2) has been used to reduce the particulate matter (PM) in underground structures (e.g., tunnels) due to the high performance of nitrogen oxides (NOx) abatement. Damage (e.g. crack, spalling, or detachment) can be caused by the environmental and ageing effects on the surface of the particulate matter reduction concrete, installed on the tunnel lining. Therefore, it is important to evaluate the existence of spalling on the concrete surface for maintaining performance of NOx reduction. In this study, a basic research was performed for feasibility of spalling evaluation using electrical resistivity characteristics. Given the test results, the electrical resistivity was decreased as the ratios of activated carbon (0~15%) and TiO2 (0~25%) were increased for specimens. Under a dry condition, electrical resistivity of cement specimens, mixed with activated carbon and TiO2, was decreased up to 2.3 times, compared with the normal cement specimen. In addition, under saturation conditions (degree of saturation: 85~98%), electrical resistivity of cement specimens with activated carbon, was decreased up to 3.5 times, compared with the normal cement specimen. Regardless of the condition (dry or saturated), the difference of electrical resistivity values shows the range of 2.3~2.8 times between the mixing specimen (with activated carbon (15%) and TiO2 (25%)) and the normal cement specimen. This study can help to provide basic knowledge for spalling evaluation using the electrical resistivity on the surface of the particulate matter reduction concrete in tunnels.

Effects of N-acetylcystein on changes in parvalbumin-positive interneurons in the hippocampus after carbon monoxide poisoning (급성 일산화탄소 중독 후 해마에서 Parvalbumin 양성 중간뉴론의 변화에 대한 N-acetylcystein의 효과)

  • Kim, Seon Tae;Yoo, Su Jin
    • Journal of The Korean Society of Clinical Toxicology
    • /
    • v.19 no.2
    • /
    • pp.100-109
    • /
    • 2021
  • Purpose: The purpose of this study was to investigate effect of N-acetylcysteine (NAC) on the injury of putative parvalbumin positive interneurons defined by molecular marker and hippocampal long-term potentiation (LTP), a marker of neural plasticity following acute carbon monoxide (CO) poisoning. Methods: Adult Sprague-Dawley rats were exposed to 1100 ppm CO for 40 minutes followed by 3000 ppm CO for 20 minutes. Animals received daily intraperitoneal injection of NAC (150 mg/kg) for 5 days after CO exposure. Changes in learning and spatial memory were evaluated by Y-maze test 5 days after the poisoning. In vivo LTP in hippocampal CA1 area was evaluated by using extracellular electrophysiological technique. Immunohistochemical staining were adopted to observe expressional damages of parvalbumin (PV) immunoreactive interneurons in the hippocampus following the poisoning. Results: Acute CO intoxication resulted in no changes in memory performance at Y-maze test but a significant reduction of LTP in the in hippocampal CA1 area. There was also a significant reduction of PV (+) interneurons in the hippocampal CA1 area 5 days after CO poisoning. Daily treatment of NAC significantly improved hippocampal LTP impairment and reduced immunoreactivity for PV in the hippocampus following the acute CO poisoning. Conclusion: The results of this study suggest that reduction of hippocampal LTP and PV (+) interneurons in the hippocampus is sensitive indicator for brain injury and daily NAC injections can be the alternative therapeutics for the injury induced by acute CO poisoning.

Complementary measures for Environmental Performance Evaluation Index of External Space of Green Standard for Energy and Environmental Design for Apartment Complex - Focused on the Respect of Response to Climate Change - (공동주택 녹색건축인증기준의 외부공간 환경성능 평가지표 보완방안 - 기후변화 대응 측면을 중심으로 -)

  • Ye, Tae-Gon;Kim, Kwang-Hyun;Kwon, Young-Sang
    • Journal of the Architectural Institute of Korea Planning & Design
    • /
    • v.34 no.1
    • /
    • pp.3-14
    • /
    • 2018
  • An apartment complex is a building use with great potential to contribute to solving problems related to urban ecological environment and climate change. The first goal of this study is to grasp the current situation of application and limitations of the ecological area rate, which is a representative evaluation index used to evaluate the environmental performance of the external space of an apartment complex in Green Standard for Energy and Environmental Design (G-SEED). The second goal is to propose a prototype of the evaluation index for evaluating greenhouse gas (GHG) reduction performance in order to supplement the evaluation index for the environmental performance of the external space in terms of response to climate change. We analyzed 43 cases of apartment complexes certified according to G-SEED, which was enforced since July 1, 2010, and found application characteristics of each space type and the limitations of ecological area rate. We analyzed overseas green building certification systems such as LEED and BREEAM that derived implications for supplementing the limitations of ecological area rate, which is focused on the evaluation of soil and water circulation function, and set up a development direction of complementary measures. Through analysis of previous studies, relevant regulations and standards, and technical documents of the manufacturer, the heat island mitigation performance of the pavement and roof surfaces of the apartment complex and the carbon uptake performance of the trees in the apartment complex was selected as parameters to yield the GHG reduction performance of the external space of the apartment complex. Finally, a quantitative evaluation method for each parameter and a prototype of the evaluation index for the GHG reduction performance were proposed. As a result of applying the prototype to an apartment complex case, the possibility of adoption and applicability as an evaluation index of G-SEED were proved.

Electrochemical Performance of Hollow Silicon/Carbon Anode Materials for Lithium Ion Battery (리튬이차전지용 Hollow Silicon/Carbon 음극소재의 전기화학적 성능)

  • Jung, Min Ji;Lee, Jong Dae
    • Applied Chemistry for Engineering
    • /
    • v.27 no.4
    • /
    • pp.444-448
    • /
    • 2016
  • Hollow silicon/carbon (H-Si/C) composites as anode materials for lithium ion batteries were investigated to overcome the large volume expansion. H-Si/C composites were prepared as follows; hollow $SiO_2\;(H-SiO_2)$ was prepared by adding $NaBH_4$ to $SiO_2$ synthesized using $st{\ddot{o}}ber$ method followed by magnesiothermic reduction and carbonization of phenolic resin. The H-Si/C composites were analyzed by XRD, SEM, BET and EDX. To improve the capacity and cycle performance, the electrochemical characteristics of H-Si/C composites synthesized with various $NaBH_4$ contents were investigated by charge/discharge, cycle, cyclic voltammetry and impedance tests. The coin cell using H-Si/C composite ($SiO_2:NaBH_4=1:1$ in weight) in the electrolyte of $LiPF_6$ dissolved in organic solvents (EC : DMC : EMC = 1 : 1 : 1 vol%) has better capacity (1459 mAh/g) than those of other composition coin cells. It is found that the coin cell ($SiO_2:NaBH_4=1:1$ in weight) has an excellent capacity retention from 2nd cycle to 40th cycle.

Electrochemical Properties of SiOx Anode for Lithium-Ion Batteries According to Particle Size and Carbon Coating (입자 크기 및 탄소 코팅에 따른 리튬이온배터리용 SiOx 음극활물질의 전기화학적 특성)

  • Anna Park;Byung-Ki Na
    • Korean Chemical Engineering Research
    • /
    • v.62 no.1
    • /
    • pp.19-26
    • /
    • 2024
  • In this study, the electrochemical properties of SiOx@C composite materials were prepared to alleviate volume expansion and cycle stability of silicon and to increase the capacity of anode material for LIBs. SiO2 particles of 100, 200, and 500 nm were synthesized by the Stӧber method, and reduced to SiOx (0≤x≤2) through the magnesiothermic reduction method. Then, SiOx@C anode materials were synthesized by carbonization of PVC on SiOx. The physical properties of prepared SiOx and SiOx@C anode materials were analyzed by XRD, SEM, TGA, Raman spectroscopy, XPS and BET. The electrochemical properties were investigated by cycling performance, rate performance, CV and EIS test. As a result, the SiOx@C-7030 manufactured by coating carbon at SiOx : C = 70 : 30 on a 100 nm SiOx with the smallest particle size showed the best electrochemical properties with a discharge capacity of 1055 mAh/g and a capacity retention rate of 81.9% at 100 cycles. It was confirmed that cycle stability was impoved by reducing particle size and carbon coating.

Performance and emission characteristics of biodiesel blends in a premixed compression ignition engine with exhaust gas recirculation

  • Kathirvelu, Bhaskar;Subramanian, Sendilvelan
    • Environmental Engineering Research
    • /
    • v.22 no.3
    • /
    • pp.294-301
    • /
    • 2017
  • This paper is based on experiments conducted on a stationary, four stroke, naturally aspirated air cooled, single cylinder compression ignition engine coupled with an electrical swinging field dynamometer. Instead of 100% diesel, 20% Jatropha oil methyl ester with 80% diesel blend was injected directly in engine beside 25% pre-mixed charge of diesel in mixing chamber and with 20% exhaust gas recirculation. The performance and emission characteristics are compared with conventional 100% diesel injection in main chamber. The blend with diesel premixed charge with and without exhaust gas recirculation yields in reduction of oxides of nitrogen and particulate matter. Adverse effects are reduction of brake thermal efficiency, increase of unburnt hydrocarbons (UBHC), carbon monoxide (CO) and specific energy consumption. UBHC and CO emissions are higher with Diesel Premixed Combustion Ignition (DPMCI) mode compared to compression ignition direct injection (CIDI) mode. Percentage increases in UBHC and CO emissions are 27% and 23.86%, respectively compared to CIDI mode. Oxides of nitrogen ($NO_x$) and soot emissions are lower and the percentage decrease with DPMCI mode are 32% and 33.73%, respectively compared to CIDI mode.

Investigation of Mix Design Method in Concrete Mixed with SSPCM Based on Mechanical Behaviors (SSPCM 혼입 콘크리트의 역학적 성능 기반 배합설계기법 연구)

  • Min, Hae-Won;Kim, Hee-Sun
    • Journal of the Korean Society for Advanced Composite Structures
    • /
    • v.6 no.2
    • /
    • pp.1-7
    • /
    • 2015
  • As energy consumption of building and the reduction of carbon dioxide emissions have been emphasized, phase change materials(PCM) have been introduced as building materials due to its high heat storage performance. Using shape-stabilizing technique, octadecane/xGnP shape-stabilized PCM(SSPCM) can prevent leakage and improve heat storage performance. The objectives of this study are to propose mix design method of concrete mixed with SSPCM and to evaluate mechanical behaviors of the concrete mixed with SSPCM manufactured according to the proposed mix design. Based on the previously reported material test result, the existing mix design of plain concrete(Concrete standard specification, 2009) is modified to consider reduction of strength in concrete due to the addition of SSPCM. To verify the proposed mix design, specimens are fabricated according to the proposed mix design and axial strength tests and three-point loading tests are performed. Test results show that compressive strengths of the tested specimens reach the designed strength even when two different mix ratios of SSPCM are used. From three-point loading tests, flexural stresses decrease as mix ratio of SSPCM increases.

Production of Precast Concrete using Eco-friendly Lightweight Concrete (친환경 경량콘크리트를 이용한 프리캐스트 콘크리트 제작)

  • Lee, Soo-Hyung;Lee, Han-Baek
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2016.05a
    • /
    • pp.179-180
    • /
    • 2016
  • This study has a purpose of producing precast concrete for rapid construction of urban railway system. However, previous precast concrete has problem of its weight itself and there has been a keen interest in effect of carbon emission reduction and eco-friendly in our society. Therefore, in order to solve these two problems, we are about to produce precast concrete using lightweight aggregate and eco-lightweight concrete, with which much mineral had been replaced. As a result, we could confirm that it was possible to produce RMC B/P production satisfying the requirement performance of eco-lightweight concrete, which is replaced with a great amount of mineral for reduction of precast concrete's weight and environmental performance. Also, by confirming the possibility of producing precast concrete which lightweight concrete is used, if producing precast concrete by using eco-lightweight concrete, it would be effective to avoid destruction of environment and much useful to use multiple tower crane when constructing. Afterward, we will proceed our study by constructing precast concrete at which eco-lightweight concrete is used for continuous quality improvement.

  • PDF