• 제목/요약/키워드: Carbon paste electrodes

검색결과 42건 처리시간 0.024초

전사 인쇄에 의한 3D와 다층의 Pt 전극의 CO가스 흡착 (CO Adsorption on Three-Dimensional and Multilayered Platinum Electrode Prepared through Transfer Printing)

  • 정윤서;최유정;신정희;정영훈;박종후;윤대호;조정호
    • 센서학회지
    • /
    • 제29권4호
    • /
    • pp.232-236
    • /
    • 2020
  • Three-dimensional (3D) multilayered Pt electrodes were fabricated to develop a porous electrode using a pattern-transfer printing process. The Pt thin films were deposited using a transferred sputtering pattern having a 250 nm line width on the substrate, and the uniform line patterns were efficiently transferred using our proposed method. Temperature-programmed desorption (TPD) analyses were used to evaluate the porosity of the electrodes. It was possible to distinguish between two resolved maxima at 168 and 227 ℃, which could be described in terms of desorption reactions on the Pt (111) planes. The results of the TPD analysis of the 3D and multilayered Pt electrodes prepared through transfer printing were compared to those of an electrode fabricated through screen printing using a commercial Pt-carbon paste commonly used as porous electrodes. It was confirmed that the 3D multilayered electrodes exhibited a desorption concentration approximately 100 times higher than that of the Pt-carbon composite electrode, and the desorption concentration increased by approximately 0.02 mg/mol per layer. The 3D multilayered electrode effectively functions as a porous electrode and a catalyst.

Voltammetric Assay of Antibiotics for Modified Carbon Nanotube Sensor

  • Ly, Suw-Young;Yoo, Hai-Soo;Lee, Chang-Hyun
    • 한국응용과학기술학회지
    • /
    • 제29권3호
    • /
    • pp.443-449
    • /
    • 2012
  • A investigation of electrochemical analysis of antibiotics Neomycin ($C_{23}H_{46}N_6O_{13}$) was searched using electrochemical square wave (SW) stripping and cyclic voltammetry (CV) using working sensor of the modified carbon nanotube combination electrodes, optimum diagnostic parameters were searched by anodic stripping, final conditions were attained to working range of 1.0-14.0 ng/L, detection limit (S/N) was found to be 0.6 ng/L. The developed method was discovered to be fitting in quality control in the food, pharmaceutical and other manufacturing sectors.

전기방사법으로 제작한 In2O3 나노섬유 기반 고감도 실내독성 CO 및 HCHO 가스센서 (Highly Sensitive Gas Sensors Based on Electrospun Indium Oxide Nanofibers for Indoor Toxic CO and HCHO Gases)

  • 임동하;황성환;권세훈;정현성
    • 한국전기전자재료학회논문지
    • /
    • 제29권12호
    • /
    • pp.803-808
    • /
    • 2016
  • In this work, one dimension $In_2O_3$ nanostructures as detecting materials for indoor toxic gases were synthesized by an electrospinning process. The morphology of electrospun $In_2O_3$ nanofibers was controlled by electrolyte composition, applied voltage and working distance between a nozzle and a substrate. The synthesized $In_2O_3$ nanofibers-based paste with/without carbon black additives was prepared for the integration on a sensor device. The integration of $In_2O_3$ sensing materials was conducted by a hand-printing of the paste into the interdigit Au electrodes patterned on Si wafer. Gas sensing properties on CO and HCHO gases were characterized at $300^{\circ}C$. The evaluated sensing properties such as sensitivity, response time and recovery time were improved in $In_2O_3$ nanofiber pastes with carbon black, compared to the paste without carbon black.

4갈락토오즈 측정을 위한 전기화학적 바이오센서 개발 (Development of electrochemical biosensor for determination of galactose)

  • 박갑수;조순삼;권덕;이재선;차근식;남학현
    • 분석과학
    • /
    • 제20권5호
    • /
    • pp.393-399
    • /
    • 2007
  • 본 연구에서는 갈락토오즈의 현장검사(point-of-care testing, POCT)를 위한 일회용 갈락토오즈 바이오센서 개발에 관해 논하고자 한다. Galactose oxidase(GAO)와 horseradish peroxidase(HRP) 두 효소를 0.05 M phosphate 완충용액에 용해시킨 후 스크린 프린팅(screen printing) 방법으로 제작한 전극위에 고정화하여 센서를 제작하였다. 이렇게 제작된 센서를 이용하여 $100{\mu}L$ 이하의 시료를 이용하여 갈락토오즈를 90초 이내에 측정하였다. 전극에서의 반응을 최적화하기 위하여 GAO 효소가 가장 우수한 활성을 나타내는 pH 7.0 완충용액을 이용하여 GAO와 HRP 효소를 1:1로 고정화하고, 1mM 1,1'-ferrocene-dimethanol 전자전달매개체를 도입하여 센서를 제작하였다. 유리 탄소전극의 경우 100 mV (vs Ag/AgCl), 스크린 프린트된 전극의 경우 -100 mV(vs Ag/AgCl)의 인가전압을 적용하였다. 본 연구에 의해 개발된 센서는 $0{\sim}400{\mu}M$의 갈락토오즈 농도에 대하여 우수한 직선성($r^2$ = 0.997, S/N = 3)을 나타내었고 낮은 인가전압을 적용하여 갈락토오즈를 측정하므로, ascorbic acid, uric acid 그리고 acetaminophen과 같은 방해물질의 영향을 최소화 할 수 있었다. 또한 갈락토오즈 표준 용액에 대하여 만족할 만한 재현성을 나타내었다(CV = 5%).

과산화수소 정량을 위한 서양고추냉이 과산화효소 대용 아카시아의 활용 (Application of Acacia as an Alternative to Horseradish Peroxidase for the Determination of Hydrogen Peroxide)

  • 윤길중
    • 공업화학
    • /
    • 제28권3호
    • /
    • pp.369-374
    • /
    • 2017
  • 바이오센서를 상업적으로 양산하고자 할 때 제작비의 경제성이 고려되어야 한다. 과산화수소를 정량하기 위한 효소전극 제작 시 필수적으로 사용되는, 서양고추냉이로부터 추출된 과산화효소는 대단히 고가이므로 탄소반죽법에 의한 전극제작의 제한 요인이 된다. 이 문제를 우회하고자 본 실험실에서는 생활주변에서 쉽게 얻을 수 있는 재료로 대체하기 위하여 아카시아 잎을 효소원으로 사용하여 과산화수소 센서를 제작하고 그것의 전기화학적 특성을 살펴보았다. 일정전압전류법으로 얻어진 10개 이상의 전기화학적 파라미터와 실험적 결과들은 효소전극이 정량적으로 그 기능을 발휘하고 있음을 보여주었다. 이런 사실들은 시판 과산화효소가 아카시아 잎으로 대체될 수 있음을 보여주는 것이다.

HDPE 가교 결합과 계면 접착력 변화에 따른 PTC 특성 연구 (Effects of Interfacial Adhesion and Chemical Crosslinking of HDPE Composite Systems on PTC Characteristics)

  • 김재철;이종훈;남재도
    • 폴리머
    • /
    • 제27권4호
    • /
    • pp.275-284
    • /
    • 2003
  • 접착성이 없는 고밀도 폴리에틸렌 (HDPE)과 나노입자 카본블랙 복합체를 대상으로 전극과의 계면 접착 향상과 고분자 가교 특성에 따른 양온도 계수 (PTC) 특성을 연구하였다. 은페이스트를 전극으로 사용하였을 때에는, 전극과 HDPE의 접착 계면 저항으로 인하여 카본함량이 45 wt% 이상에서 1 $\Omega$ 이었으나, 덴드라이트 (dendrite)된 구리 전극의 경우 HDPE와 전극간의 넓은 면적 접촉에 의한 계면 저항이 0.2 $\Omega$ 이하였다. HDPE와 은페이스트의 계면 저항의 증가로 인하여 구리 박막을 사용하였을 때보다 전체적으로 저항이 높게 나타났다. HDPE와 나노입자 카본블랙 복합체는 온도가 증가하여 HDPE의 비캣연화온도까지는 저항이 일정하게 유지하다가, HDPE의 연화점에서 증가하기 시작하여 용융점에서 극대 값을 나타내는 전형적인 PTC특성을 보여주었다. 일반적으로 HDPE의 용융점을 넘어서면 음온도 계수 (NTC) 현상이 나타나는데, 가교결합을 시킨 HDPE의 경우는, 용융점 이상에서 NTC 현상이 나타나지 않고 저항이 일정하게 유지되거나 증가하는 경향이 나타났다. 구리 (copper) 전극과 고분자와의 계면 접촉 면적을 증가시키기 위하여 크롬 (chromium)을 덴드라이트시킨 전극을 사용하여 계면 접촉 저항을 감소시켰다.

감광성 CNT 페이스트를 이용한 IED 폭발물 제거로봇 탐지전극 형성에 관한 연구 (A Study on the Formation of Detection Electrode for the IED Removal Robot by Using A Photosensitive CNT Paste)

  • 권혜진
    • 한국전기전자재료학회논문지
    • /
    • 제31권4호
    • /
    • pp.231-237
    • /
    • 2018
  • In this study, two important requirements for the home production of a robot to detect and remove improvised explosive devices (IEDs) are presented in terms of the total cost for robot system development and the performance improvement of the mine detection technology. Firstly, cost analyses were performed in order to provide a reasonable solution following an engineering estimate method. As a result, the total cost for a mass production system without the mine detection system was estimated to be approximately 396 million won. For the case including the mine detection system, the total cost was estimated to be approximately 411 million won, in which labor costs and overhead charges were slightly increased and the material costs for the mine detection system were negligible. Secondly, a method for fabricating the carbon nanotube (CNT) based gas detection sensor was studied. The detection electrodes were formed by a photolithography process using a photosensitive CNT paste. As a result, this method was shown to be a scalable and expandable technology for producing excellent mine detection sensors. In particular, it was found that surface treatments by using adhesive taping or ion beam bombardment methods are effective for exposing the CNTs to the ambient air environment. Fowler-Nordheim (F-N) plots were obtained from the electron-emission characteristics of the surface treated CNT paste. The F-N plot suggests that sufficient electrons are available for transport between CNT surfaces and chemical molecules, which will make an effective chemiresistive sensor for the advanced IED detection system.

Alga변성전극을 이용한 Cadmium(Ⅱ)의 양극벗김 전압-전류법적 정량 (Anodic Stripping Voltammetric Determination of Cadmium(Ⅱ) Using Alga-Modified Carbon Paste Electrodes)

  • 배준웅;최정은;장혜영
    • 대한화학회지
    • /
    • 제42권1호
    • /
    • pp.28-35
    • /
    • 1998
  • Alga와 같은 미생물은 중금속을 흡수한다. Alga(Anabaena)로 변성시킨 탄소반죽전극으로 Cd(Ⅱ)이온을 사전농축시켜서 Cd(Ⅱ)을 양극벗김 펄스차이 전압-전류법으로 정량하였다. Cd(Ⅱ)의 산화봉우리는 -0.75V vs. SCE.에서 나타났으며, 이 봉우리를 이용하여 Cd(Ⅱ) 정량의 최적조건을 조사하였다. 변성전극의 제작에 미치는 alga양의 영향과 Cd(Ⅱ)의 사전농축에 미치는 pH와 이온세기, 온도 및 사전농축시간에 대한 영향을 조사하였으며. 전극표면에 사전 농축시킨 Cd(Ⅱ)이온을 전해환원시키는 시간과 전위의 영향도 조사하였다. Cd(Ⅱ)을 정량하기 위한 검정선은 $1.0{\times}10^6\;M ~ 8.0{\times}10^6\;M$범위에서 직선성(상관계수는0.9978)이 성립하였고 검출한계는 $5.0{\times}10^{-7}\;M$이었다. $7.0{\times}10^{-6}\;M$ Cd(Ⅱ)용액에서 얻은 상대표준편차는 3.1%(n=6)이었다. Alga변성전극의 사용횟수는 0.1M HCl 용액으로 전극표면을 재생시킬 때에 10회까지 연속측정이 가능하였다.

  • PDF

Low cost, highly sensitive and selective electrochemical detection of arsenic (III) using silane grafted based nanocomposite

  • Lalmalsawmi, Jongte;Zirlianngura, Zirlianngura;Tiwari, Diwakar;Lee, Seung-Mok
    • Environmental Engineering Research
    • /
    • 제25권4호
    • /
    • pp.579-587
    • /
    • 2020
  • Novel silane grafted bentonite was obtained using the natural bentonite as precursor material. The material which is termed as nanocomposite was characterized by the Fourier Transform Infra-red (FT-IR) and X-ray diffraction (XRD) methods. The surface imaging and elemental mapping was performed using Scanning Electron Microscopic (SEM/EDX) technique. The electroanalytical studies were performed using the nanocomposite electrode. The electroactive surface area of nanocomposite electrode was significantly increased than the pristine bentonite or bare carbon paste based working electrode. The impedance spectroscopic studies were conducted to simulate the equivalent circuit and Nyquist plots were drawn for the carbon paste electrode and nanocomposite electrodes. A single step oxidation/reduction process occurred for As(III) having ΔE value 0.36 V at pH 2.0. The anodic stripping voltammetry was performed for concentration dependence studies of As(III) (0.5 to 20.0 ㎍/L) and reasonably a good linear relationship was obtained. The detection limit of the As(III) detection was calculated as 0.00360±0.00002 ㎍/L having with observed relative standard deviations (RSD) less than 4%. The presence of several cations and anions has not affected the detection of As(III) however, the presence of Cu(II) and Mn(II) affected the detection of As(III). The selectivity of As(III) was achieved using the Tlawng river water sample spiked with As(III).

Electrochemical Detection of Hydroxychloroquine Sulphate Drug using CuO/GO Nanocomposite Modified Carbon Paste Electrode and its Photocatalytic Degradation

  • G. S. Shaila;Dinesh Patil;Naeemakhtar Momin;J. Manjanna
    • 전기화학회지
    • /
    • 제27권1호
    • /
    • pp.15-31
    • /
    • 2024
  • The antimalarial drug hydroxychloroquine sulphate (HCQ) has taken much attention during the first COVID-19 pandemic phase for the treatment of severe acute respiratory infection (SARI) patients. Hence it is interest to study the electrochemical properties and photocatalytic degradation of the HCQ drug. Copper oxide (CuO) nanoparticles, graphene oxide (GO) and CuO/GO NC (nanocomposite) modified carbon paste electrodes (MCPE) are used for the detection of HCQ in an aqueous medium. Electrochemical behaviour of HCQ (20 μM) was observed using CuO/MCPE, GO/MCPE and CuO/GO NC/MCPE in 0.1 M phosphate buffer at pH 7 with a scan rate of 20 to 120 mV s-1 by cyclic voltammetry (CV). Differential pulse voltammetry (DPV) of HCQ was performed for 0.6 to 16 μM HCQ. The CuO/GO NC/MCPE showed a reasonably good sensitivity of 0.33 to 0.44 μA μM cm-2 with LOD of 69 to 92 nM for HCQ. Furthermore, the CuO/GO NC was used as a catalyst for the photodegradation of HCQ by monitoring its UV-Vis absorption spectra. About 98% was degraded in about 34 min under visible light and after 4 cycles it was 87%. The improved photocatalytic activity may be attributed to decrease in bandgap energy and enhanced ability for the electrons to migrate. Thus, CuO/GO NC showed good results for both sensing and degradation applications as well as reproducibility.