• Title/Summary/Keyword: Capacitance design

Search Result 532, Processing Time 0.028 seconds

A 2 GHz Compact Analog Phase Shifter with a Linear Phase-Tune Characteristic (2 GHz 선형 위상 천이 특성을 갖는 소형 아날로그 위상천이기)

  • Oh, Hyun-Seok;Choi, Jae-Hong;Jeong, Hae-Chang;Heo, Yun-Seong;Yeom, Kyung-Whan
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.22 no.1
    • /
    • pp.114-124
    • /
    • 2011
  • In this paper, we present a 2 GHz compact analog phase shifter with linear phase-tune characteristic. The compact phase shifter was designed base on a lumped all pass network and implemented using a ceramic substrate fabricated with thin-film technique. For a linear phase-tune characteristic, a capacitance of the varactor diode for a tuning voltage was linearized by connecting series capacitor and subsequently produced an almost linear capacitance change. The inductor and bias circuit in the all pass network was implemented using a spiral inductors for small size, which results in the size reduction to $4\;mm{\times}4\;mm$. In order to measure the phase shifter using the probe station, two CPW pads are included at the input and output. The fabricated phase shifter showed an insertion loss of about 4.2~4.7 dB at 2 GHz band and a total $79^{\circ}$ phase change for DC control voltage from 0 to 5 V, and showed linear phase-tune characteristic as expected in the design.

Estimation Error and Reliability of Measuring Unit Water Content Test Methods for Fresh Concrete Depending on Mix Design Factors at the Laboratory Level (실험실 수준에서 배합변수별 굳지 않은 콘크리트 단위수량 실험방법의 추정오차 및 신뢰성 검토)

  • Park, Min-Yong;Han, Min-Cheol
    • Journal of the Korean Recycled Construction Resources Institute
    • /
    • v.10 no.1
    • /
    • pp.101-110
    • /
    • 2022
  • In this study, water content tests were performed on various fresh concretes subjected to different binder compostions to review the estimation errors and reliability of water content test methods. Micro-oven drying method, air-meter method, capacitance method and microwave penetration method were used to estimate water content of fresh concrete. Errors in water content estimation were analyzed by each test method. Regardless of the test method of water content, the estimation error was less than 5 %, and in the case of the test using mortar, the error in the estimation value was relatively large. In addition, based on the test results of water content of various concrete, the probability density function in which the estimation error for each test method becomes the population was analyzed. Water content test methods of fresh concrete which using concrete samples showed high estimate reliability of 97 % within the estimation error range of ± 10 kg/m3. On the other hand, the reliability of water content test method using mortar samples was lower.

Optimal circuit desgn Taking into Account The frquency dependence of coil's Q (자심코일의 Q의 주파수특성을 고려한 회로의 최적화설계)

  • 박송배
    • Journal of the Korean Institute of Telematics and Electronics
    • /
    • v.11 no.4
    • /
    • pp.23-28
    • /
    • 1974
  • One of the consistent nuisances in accurate design of circuits containing coils with core is how to take into account the frequency dependence of Q of actual coils. The conventional equivalent circuit consisting of an inductance and a series (constant) resistance and possibly a parallel (constant) capacitance is of little use in this situation since the core loss itself is strongly dependent on the frequency. In order to circumvent this difficulty, in this paper, a mathematical expression for Q of a given core as a function of inductance and frequency is first assumed and parameters in this expression are optimiged so as to best fit the data provided by the core manufacturer or obtained experimentally. This expression is then utilized in accurate calculation of the frequency response of a given circuit required in the optimal design of circuits containing coils. In other words the proposed approach is an effective combination of an approximate expression of coil's Q and circuit optimisation technique, which seems to have solved, to a great extent, the stated difficulty associated with actual coils. As for the optimization technique, ths Fletcher-Powell procedure was employed and one example was given to illustrate the proposed approach.

  • PDF

A New Type of 5-Pole Low Pass Filter Using Defected Ground Structure (결함 접지 구조를 이용한 새로운 5-단 저역 통과 여파기)

  • Lim Jong-Sik;Kim Chul-Soo;Ahn Dal;Jeong Yong-Chae;Nam Sangwook;Kim Kwangsoo
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.16 no.6 s.97
    • /
    • pp.594-602
    • /
    • 2005
  • In this paper, a new type of 5-pole low pass filter(LPF) having defected ground structure(DGS) and very wide transmission line elements is proposed. The previously presented design method of 3-stage LPF using DGS is generalized to design N-pole LPFs for $N\geq5$. As an example, a 5-pole LPF having DGS is designed and measured. The accurate curve-fitting method to determine the series inductors in the prototype filter, and ultimately the size of DGS is described. The proposed 5-pole LPF has transmission line elements with a very low impedance to realize the required shunt capacitance instead of open stubs. Therefore, open stub. Therefore, open stub, Tee-junction, Cross-junction, and high impedance line are not required for the proposed LPF, while they all have been essential in conventional LPFs.

Design of a MIMO Antenna Using a RF MEMS Element (RF MEMS 소자를 이용한 MIMO 안테나 설계)

  • Lee, Won-Woo;Rhee, Byung-Ho
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.24 no.12
    • /
    • pp.1113-1119
    • /
    • 2013
  • In this letter, a new approach is proposed for the design of a multi antenna for MIMO wireless devices. The proposed antenna covers various LTE(Long Term Evolution) service bands: band 17(704~746 MHz), band 13(746~787 MHz), band 5(824~894 MHz), and band 8(880~960 MHz). The proposed main antenna consists of a conventional monopole antenna with an inverted L-shaped slit for wideband operation. The proposed the LTE sub antenna is based on a switch loaded loop antenna structure, with a resonance frequency that can be controlled by capacitance of a logic circuit. The tuning technique for the LTE Rx antenna uses a RF MEMS(Micro-Electro mechanical system) to match the impedances to realize the bands of interest. Because the two proposed antennas are polarized orthogonally to each other, the ECC(Envelope Correlation Coefficient) characteristic between two antennas was measured to be very low (below 0.06) with an isolation characteristic below -20 dB between the two antennas in the operating overall LTE bands. The proposed antenna is particularly attractive for mobile devices that integrate LTE multiple systems.

Respiration Measurement System using Textile Capacitive Pressure Sensor (전기용량성 섬유 압력센서를 이용한 호흡측정 시스템)

  • Min, Se-Dong;Yun, Young-Hyun;Lee, Chung-Keun;Shin, Hang-Sik;Cho, Ha-Kyung;Hwang, Seon-Cheol;Lee, Myoung-Ho
    • The Transactions of the Korean Institute of Electrical Engineers P
    • /
    • v.59 no.1
    • /
    • pp.58-63
    • /
    • 2010
  • In this paper, we proposed a wearable respiration measurement system with textile capacitive pressure sensor. Belt typed textile capacitive pressure sensor approach of respiration measurement, from which respiration signatures and rates can be derived in real-time for long-term monitoring, are presented. Belt typed textile capacitive pressure sensor has been developed for this measurement system. the distance change of two plates by the pressure of motion has been used for the respiration measurement in chest area. Respiration rates measured with the textile capacitive pressure sensor was compared with standard techniques on 8 human subjects. Accurate measurement of respiration rate with developed sensor system is shown. The data from the method comparison study is used to confirm theoretical estimates of change in capacitance by the distance change. The current version of respiratory rate detection system using textile capacitive pressure sensor can successfully measure respiration rate. It showed upper limit agreement of $3.7997{\times}10^{-7}$ RPM, and lower limit of agreement of $-3.8428{\times}10^{-7}$ RPM in Bland-Altman plot. From all subject, high correlation were shown(p<0.0001). The proposed measurement method could be used to monitor unconscious persons, avoiding the need to apply electrodes to the directly skin or other sensors in the correct position and to wire the subject to the monitor. Monitoring respiration using textile capacitive pressure sensor offers a promising possibility of convenient measurement of respiration rates. Especially, this technology offers a potentially inexpensive implementation that could extend applications to consumer home-healthcare and mobile-healthcare products. Further advances in the sensor design, system design and signal processing can increase the range and quality of the rate-finding, broadening the potential application areas of this technology.

High Efficiency Resonant Asymmetrical Half-Bridge Flyback Converter (고효율 공진형 비대칭 하프브리지 플라이백컨버터)

  • Jeong, Gang-Youl;Yoo, Doo-Hee
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.24 no.4
    • /
    • pp.81-94
    • /
    • 2010
  • This paper presents a high efficiency resonant asymmetrical half-bridge flyback converter. The primary half-bridge circuit of the converter operates by a soft-switching type using the asymmetrical pulse-width modulation (PWM) method with the resonant capacitance and transformer leakage inductance. The secondary flyback circuit of the proposed converter utilizes a synchronous rectifier, which operates by a new voltage-driven method with a simple drive circuit. Thus the proposed converter improves the total efficiency. This paper explains the operational principle of the proposed converter by each mode and shows the converter design consideration and a design example for the prototype converter, respectively. After that, the proposed simple driving technique of the synchronous rectifier by a voltage-driven method is explained, briefly. The designed prototype converter has wide input voltage (AC $V_{in,rms}$=75~265[V]), 5[V] DC output voltage, and 100[W] output power. To verify the excellent performance of the proposed converter, the designed prototype is implemented and experimented. The good performance of the proposed converter is shown through the experimental results.

Design of a Waveguide Band-Pass Filter Using a Modified H-type Resonant Iris (변형된 H-형 공진 아이리스를 이용한 도파관 대역 통과 여파기 설계)

  • Park, Kyoung-Je;Lee, Jong-Ig;Kim, Byung-Mun;Cho, Young-Ki
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 2018.05a
    • /
    • pp.59-60
    • /
    • 2018
  • In this paper, we studied a design method for a band-pass waveguide filter with a modified H-type resonant iris (RI) placed in a thin transverse wall of a rectangular waveguide. The horizontal straight gap at the center of a conventional H-shaped iris is modified to a U-shaped one to increase the equivalent capacitance, and the equivalent inductance is improved by changing the vertical two straight slots into C-shaped ones. A third-order band pass filter using the proposed modified H-shaped iris was designed and, it was observed that the filter operated in the frequency range of 9.22-9.75 GHz with its insertion loss of 0.5 dB and return loss of 17 dB.

  • PDF

Research and Development of High Performance 50-inch HD Plasma Display Panel

  • Choi, Kwang-Yeol;Min, Woong-Kee;Rhee, Byung-Joon;Ahn, Byung-Nam;Kim, Je-Seok;Moon, Won-Seok;Park, Min-Soo;Ryu, Byung-Gil;Kim, Sung-Tae;Ahn, Young-Joon;Yang, Sung-Soo;Kim, Kyung-Tae;Lee, Kyu-Sung
    • 한국정보디스플레이학회:학술대회논문집
    • /
    • 2008.10a
    • /
    • pp.1547-1550
    • /
    • 2008
  • We are suggesting a new index to represent the performance of PDP, such as Specific Performance Index (SPI) that includes luminous efficacy and panel reflectance. High Xe gas mixture and low panel capacitance are well known as key factors to improve luminous efficacy of PDP [1]. However, higher driving voltage and longer discharge time lag is an obstacle when applying these technologies. Modified cell design, new materials and driving waveform enable us to overcome these obstacles. High efficient phosphor is also a key material to improve luminous efficacy. Phosphors coated with pigment are used to reduce panel reflectance. High performance 50-inch HD PDP with luminous efficacy of 2.3 lm/W has been developed.

  • PDF

A Design and Implementation of 4×10 Gb/s Transimpedance Amplifiers (TIA) Array for TWDM-PON (TWDM-PON 응용을 위한 4×10 Gb/s Transimpedance Amplifier 어레이 설계 및 구현)

  • Yang, Choong-Reol;Lee, Kang-Yoon;Lee, Sang-Soo
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.39B no.7
    • /
    • pp.440-448
    • /
    • 2014
  • A $4{\times}10$ Gb/s Transimpedance Amplifier (TIA) array is implemented in $0.13{\mu}m$ CMOS process technology, which will be used in the receiver of TWDM-PON system. A technology for bandwidth enhancement of a given $4{\times}10$ Gb/s TIA presented under inductor peaking technology and a single 1.2V power supply based low voltage design technology. It achieves 3 dB bandwidth of 7 GHz in the presence of a 0.5 pF photodiode capacitance. The trans-resistance gain is $50dB{\Omega}$, while 48 mW/ 1channel from a 1.2 V supply. The input sensitivity of the TIA is -27 dBm. The chip size is $1.9mm{\times}2.2mm$.