• 제목/요약/키워드: Capacitance Measurement

검색결과 397건 처리시간 0.024초

접지된 Shield Plate를 이용한 집적회로의 배선용량 측정 (Direct Measurement of the VLSI Interconnection Line Capacitances Using a Grounded Shield Plate)

  • 강래구;전성오;신윤승
    • 대한전자공학회논문지
    • /
    • 제25권3호
    • /
    • pp.302-307
    • /
    • 1988
  • A noble interconnection line capacitance measurement method to be able to remove the measurement errors from the probe pad to substrate stray capacitance has been proposed and verified. The measurement errors in the capacitance measurement, which usually be involved from the probe pad to substrate stray capacitance, can easily be removed by isolating the metal probe pad from the substrate with a grounded shield plate between the probe pad the substrate. The measurement results by using this improved capacitance measurement method were compared with the calculations by two-dimensional computer simulations.

  • PDF

Cross Capacitance 원리를 작용한 새로운 유전상수 측정방법 제안 (A New Measurement Method of Dielectric Constants Applied the Principles of Cross Capacitance)

  • 김한준;이래덕;강전흥;유광민;한상옥
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2002년도 하계학술대회 논문집 Vol.3 No.2
    • /
    • pp.1084-1087
    • /
    • 2002
  • The guard-ring type 3-terminal parallel plate electrodes proposed by ASTM D 150-81 and IEC 250 have been widely used for measurement of dielectric constants of solid dielectrics. However the method using this electrodes causes many uncertainty associated with the measurement errors of the diameter of the guarded electrode. the gap between guarded and guard-ring electrode. the distance of two active electrodes(the thickness of specimen), the roughness and contamination of surface of electrode and specimen. close adherence grade of electrode and specimen. In this paper. a new electrode system of cross capacitance type based on Thompson-Lampard theorem is designed and is employed for the measurement of dielectric constant. The results of simulation of guard-ring electrode and cross capacitance electrode using FEM program show that distance measurement between two electrodes in guard-ring electrode produces large uncertainty. on the other hand this effect in cross capacitance electrode is negligible. Furthermore. the air gap effects in the cross capacitance electrode is 5.6 times less sensitive than that in guard-ring electrode by assuming air gap of $50{\mu}m$.

  • PDF

펨토 패럿 측정을 위한 비율형 커패시턴스 측정 회로 (Ratio-type Capacitance Measurement Circuit for femto-Farad Resolution)

  • 정재웅;정인영
    • 한국정보통신학회논문지
    • /
    • 제16권5호
    • /
    • pp.989-998
    • /
    • 2012
  • 본 논문에서는 매우 작은 절대 값을 갖는 펨토 패럿 단위의 커패시턴스를 측정 할 수 있는 비율형 커패시턴스 측정 회로를 제안하였다. 제안한 측정 회로는 스위치 커패시터 적분기와 비교기 그리고 스위치를 제어하는 논리 회로와 카운터로 구성되어 있으며, 측정하고자 하는 커패시턴스와 이미 값이 알려진 온-칩 커패시터간의 비율을 측정하고 그 값을 디지털 신호로 출력한다. 그리고 이 비율 값을 통해 오차가 상당부분 제거된 펨토 패럿 단위의 커패시턴스를 구해낼 수 있다. 제안한 커패시턴스 측정 회로는 표준 CMOS $0.18{\mu}m$ 공정을 사용하여 설계되었으며, HSpice 시뮬레이션에서 5fF 이하의 아주 작은 커패시턴스를 오차율 ${\pm}0.3%$ 이내에서 측정이 가능함을 보였다.

Cross Capacitance 측정법을 이용한 유전상수 정밀측정 (Precise Measurement of Dielectric Constant Using Cross Capacitance Measurement Method)

  • 김한준;강전홍;유광민;이세현;구경완;한상옥
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2007년도 제38회 하계학술대회
    • /
    • pp.1287-1288
    • /
    • 2007
  • The cross capacitor electrode system applied Thompson-Lampard theorem for precise and accurate measurement of dielectric constants is studied in this study. The capacitance derived from cross capacitor is calculated by the equation of ($C=\frac{{\epsilon}ln2}{\pi}{\cdot}$ effectivelength of electrode) which is very different from the equation of capacitance derived from parallel plate capacitor. From above mentioned reason, the capacitance measurement uncertainty of cross capacitor can be reduced then that of the parallel plate capacitor. the measurement dielectric constant measured by cross capacitor electrode method is one order more accurate and precise than that of 3-electrode method.

  • PDF

A Study for Implementation of Density Measurement Equipment for Asphalt Pavement based on the electromagnetic capacitance

  • Park, Young-Ho;Kim, Gun-Kyun;Nor, Jeong-Keun;Ha, Jae-Kwon
    • International Journal of Contents
    • /
    • 제6권4호
    • /
    • pp.39-42
    • /
    • 2010
  • In this paper we developed density measurement equipment for Asphalt Pavement based on the electromagnetic capacitance. This kind of Non-Nuclear Density Gauges technology and products is used or studied in USA, Finland, Sweden as standardization of authorized method for pavement density measurement. Effective permitivity of pavement asphalt is characterized in electromagnetic capacitance by the asphalt material, mixed ratio, and harden grade of pavement asphalt. We can get a density value of asphalt by replacing value of electromagnetic capacitance with standard density value and characteristic transformation curve. We are conformed that measurement data according to temperature, humidity, and real field asphalt of our density measurement equipment can be a precise value.

BURR SIZE MEASUREMENT USING A CAPACITANCE SENSOR

  • Lee, Seoung-Hwan
    • 한국생산제조학회지
    • /
    • 제8권4호
    • /
    • pp.29-37
    • /
    • 1999
  • This paper involves the "on-line" measurement of burrs using a capacitance sensor. A non-contact capacitance gauging sensor is attached to an ultra precision milling machine which was used as a positioning system The setup is used to measure burr profiles along machined workpiece edges. Experimental procedures and results as well as the basic theoretical principles of the capacitance sensor and specifications of related equipment are presented. The proposed scheme is shown to be accurate easy to setup and with minor modifications readily applicable to automatic deburring processes.processes.

  • PDF

The thermal effect on electrical capacitance sensor for two-phase flow monitoring

  • Altabey, Wael A.
    • Structural Monitoring and Maintenance
    • /
    • 제3권4호
    • /
    • pp.335-347
    • /
    • 2016
  • One of major errors in flow rate measurement for two-phase flow using an Electrical Capacitance Sensor (ECS) concerns sensor sensitivity under temperature raise. The thermal effect on electrical capacitance sensor (ECS) system for air-water two-phase flow monitoring include sensor sensitivity, capacitance measurements, capacitance change and node potential distribution is reported in this paper. The rules of 12-electrode sensor parameters such as capacitance, capacitance change, and change rate of capacitance and sensitivity map the basis of Air-water two-phase flow permittivity distribution and temperature raise are discussed by ANSYS and MATLAB, which are combined to simulate sensor characteristic. The cross-sectional void fraction as a function of temperature is determined from the scripting capabilities in ANSYS simulation. The results show that the temperature raise had a detrimental effect on the electrodes sensitivity and sensitive domain of electrodes. The FE results are in excellent agreement with an experimental result available in the literature, thus validating the accuracy and reliability of the proposed flow rate measurement system.

A Compact and Fast Measurement System for the Detection of Small Capacitance

  • Youngshin Woo;Sung, Man-Young
    • Transactions on Electrical and Electronic Materials
    • /
    • 제2권1호
    • /
    • pp.16-21
    • /
    • 2001
  • A new technique to measure low level capacitance variations of a gyroscope is proposed. It is based on the improved CVC(capacitance to voltage converter) biased by a d.c. current source and the peak detector without any low pass filter. This setup of the measurement system makes it possible to provide higher speed of measurement and wide operation range. The d,c, drift of the conventional CVC and stray capacitances are automatically compensated. Key parameters that affect the performance of the measurement system are illustrated and computer simulation results are presented. The demonstrated measurement system for micromachined gyroscope applications shows a linearity of 0.99972 and a resolution of 0.67fF from 10 fF to 120 fF at 10 kHz.

  • PDF

정전용량에 따른 단위수량 측정기법의 영향인자에 대한 실험적 연구 (A Study on Influencing Factors of Unit-Water Measurement method according to Electrostatic capacity)

  • 위준우;이영진;김정진
    • 한국건축시공학회:학술대회논문집
    • /
    • 한국건축시공학회 2013년도 춘계 학술논문 발표대회
    • /
    • pp.232-233
    • /
    • 2013
  • The unit-water content in fresh concrete determines consistency, and play an important role in condensing the structure of concrete and enhancing the durability of concrete. The capacitance measurement method measure quickly unit-water content and is the best way to apply to construction site. In this study, the unit-water content of capacitance measurement method is estimated according to types and replacemment ratio of admixture. and the field application of capacitance measurement method is reviewed.

  • PDF

오염지반 조사를 위한 전기비저항/정전용량 측정콘의 적용성 평가 (Applicability of Resistivity/Capacitance Measurement on CPT Module for Investigation of Subsurface Contamination)

  • 오명학;김용성;유동주;박준범
    • 한국지반공학회:학술대회논문집
    • /
    • 한국지반공학회 2006년도 춘계 학술발표회 논문집
    • /
    • pp.330-337
    • /
    • 2006
  • Resistivity cone penetrometer test (RCPT) can be employed at a relatively low cost for delineation of subsurface contamination in situ, and then be supplemented with a minimum confirmatory sampling and laboratory testing program. While the resistivity measurement have potential to investigate the subsurface contamination, resistivity measurements alone will lead to some degree of ambiguity in the results. In this study, capacitance measurement was incorporated into the RCPT to overcome the ambiguity inherent in electrical resistivity measurements for delineating the subsurface contamination. This study is focused on verifying the applicability of resistivity and capacitance measurements on CPT module to provide information on contaminated subsurface by heavy metal and petroleum hydrocarbon. Laboratory model tests were performed to evaluate the sensitivity of the measured resistivity and relative capacitance on the water content and different types of contaminants. Test results show that simultaneous measurement of electrical resistivity and capacitance can give more reliable information on subsurface contamination.

  • PDF