• Title/Summary/Keyword: Cancer

Search Result 26,908, Processing Time 0.067 seconds

Effect of Hog Millet Supplementation on Hepatic Steatosis and Insulin Resistance in Mice Fed a High-fat Diet (고지방식이로 유도한 지방간 마우스에서 기장 첨가식이가 지방간 및 인슐린 저항성에 미치는 영향)

  • Park, Mi-Young;Jang, Hwan-Hee;Lee, Jin-Young;Lee, Young-Min;Kim, Jae-Hyun;Park, Jae-Hak;Park, Dong-Sik
    • Journal of the Korean Society of Food Science and Nutrition
    • /
    • v.41 no.4
    • /
    • pp.501-509
    • /
    • 2012
  • The dietary intake of whole grains is known to reduce the incidence of chronic diseases such as obesity, diabetes, cardiovascular disease, and cancer. In our previous study, hog millet (HM, $Panicum$ $miliaceum$ L.) water extract showed the highest anti-lipogenic activity among nine cereal types in 3T3-L1 cells. In this study, the effect of hog millet water extract on hepatic steatosis and lipid metabolism in mice fed a high fat diet was investigated. Mice were fed a normal-fat diet (ND), high-fat diet (HFD) or HFD containing 1% or 2% (w/w) HM for 7 weeks. Body weight and food intake were monitored during the study period. Insulin resistance by homeostasis model assessment (HOMA-IR), fasting lipid profile, hepatic fatty acid metabolism-related gene expression determined, and intraperitoneal glucose tolerance test (IGTT) were performed at the study's end. The results indicated that 1% and 2% HM diets effectively decreased liver weights, blood TG and T-cholesterol levels (p<0.05), while the HDL-cholesterol level was increased (p<0.05) compared to HFD-induced steatotsis mice. Hepatic lipogenic-related gene ($PPAR{\alpha}$, L-FABP, and SCD1) expressions decreased, whereas lipolysis- related gene (CPT1) expression increased in animals fed the 2% PME diet (p<0.05). In addition, mice fed 1% or 2% HM diet had markedly decreased IGTT and HOMA-IR, compared to the those of the HFD-induced hepatic steatosis control group (p<0.05). These results indicated that HM inhibited hepatic lipid accumulation by regulating fatty acid metabolism, and suggested that HM is useful in the chemoprevention or treatment of high fat-induced hepatic steatosis and hepatic steatosis-related disorders including hyperlipidemia, glucose sensitivity, and insulin resistance.

Antioxidant Activities and Induction of Apoptosis by Methanol Extracts from Avocado (아보카도 추출물의 Apoptosis 유도와 항산화 활성)

  • Lee, Sung-Gyu;Yu, Mi-Hee;Lee, Sam-Pin;Lee, In-Seon
    • Journal of the Korean Society of Food Science and Nutrition
    • /
    • v.37 no.3
    • /
    • pp.269-275
    • /
    • 2008
  • The avocado is a widely grown and consumed fruit that is high in nutrients and low in calories, sodium, and fats. In this study, antioxidant activities and induction of apoptosis by methanol extracts from sarcocarp, seed and peel of avocado were investigated in vitro. Contents of total polyphenols in methanol extracts from sarcocarp, seed and peel were 13.89, 137.12 and $223.45{\mu}g/mg$ respectively. Radical-scavenging activities of the methanol extracts were examined by using ${\alpha},{\alpha}$-diphenyl-${\beta}$-picrylhydrazyl (DPPH) radicals and 2,2'-azino-bis(3-ethylbenzthiazoline-6-sulfonic acid) (ABTS) assay. The methanol extracts from the peel of avocado showed higher scavenging activities against DPPH, ABTS than those from sarcocarp and seed. Apoptosis in MDA-MB-231 cells mediated by the methanol extracts of avocado was associated with the increase of activation of caspase-3 and caspase-3 target protein, PARP. Therefore, with more researches on identification and action mechanism of active compounds, the methanol extracts from peel and seed of avocado is expected to be a natural source for the developments of functional food and medical agents to prevent human breast cancer.

H2AX Directly Interacts with BRCA1 and BARD1 via its NLS and BRCT Domain Respectively in vitro (H2AX의 BRCA1 NLS domain과 BARD1 BRCT domain 각각과의 in vitro 상호 결합)

  • Bae, Seung-Hee;Lee, Sun-Mi;Kim, Su-Mi;Choe, Tae-Boo;Kim, Cha-Soon;Seong, Ki-Moon;Jin, Young-Woo;An, Sung-Kwan
    • KSBB Journal
    • /
    • v.24 no.4
    • /
    • pp.403-409
    • /
    • 2009
  • H2AX, a crucial component of chromatin, is implicated in DNA repair, cell cycle check point and tumor suppression. The aim of this study was to identify direct binding partners of H2AX to regulate cellular responses to above mechanisms. Literature reviews and bioinformatical tools were attempted intensively to find binding partners of H2AX, which resulted in identifying two potential proteins, breast cancer-1 (BRCA1) and BRCA1-associated RING domain 1 (BARD1). Although it has been reported in vivo that BRCA1 co-localizes with H2AX at the site of DNA damage, their biochemical mechanism for H2AX were however only known that the complex monoubiquitinates histone monomers, including unphosphorylated H2AX in vitro. Therefore, it is important to know whether the complex directly interacts with H2AX, and also which regions of these are specifically mediated for the interaction. Using in vitro GST pull-down assay, we present here that BRCA1 and BARD1 directly bind to H2AX. Moreover, through combinational approaches of domain analysis, fragment clonings and in vitro binding assay, we revealed molecular details of the BRCA1-H2AX and BARD1-H2AX complex. These data provide the potential evidence that each of the BRCA1 nuclear localization signal (NLS) and BARD1 BRCA1 C-terminal (BRCT) repeat domain is the novel mediator of H2AX recognition.

A Study on the State of Smoking and Smoking-Related Oral Health Knowledge Level among Some Adolescents (일부 청소년의 흡연 실태와 흡연 관련 구강건강지식수준에 관한 연구)

  • Lee, Hyun-Ok;Chun, Ju-Yeon;Ju, On-Ju
    • Journal of dental hygiene science
    • /
    • v.11 no.6
    • /
    • pp.535-542
    • /
    • 2011
  • The purpose of this study was to examine the state of smoking among adolescents and their smoking-related oral health knowledge. The subjects in this study were the teens who were selected by convenience sampling from among the students who were in their first, second and third years in four different middle schools in the city of Iksan, North Jeolla Province. A self-administered survey was conducted from June 14 to July 12, 2011, and the answer sheets from 1,219 respondents were selected for analysis. The collected data were analyzed by the statistical package 12.0, and the findings of the study were as follows: 1. The smoker students accounted for 10.6 percent. The boys and girls who smoked respectively represented 16.0 and 5.4 percent. 2. As for the period of smoking, the largest group that accounted for 51.6 percent smoked for less than a year. Concerning the amount of daily smoking, the greatest group that accounted for 91.9 percent smoked less than 10 cigarettes. As to the motivation of smoking, the biggest group that represented 52.8 percent started to smoke out of curiosity. 3. Regarding smoking-related oral health knowledge, they got a mean of 0.85. Their scores in knowledge of oral malodor(0.95), oral cavity cancer(0.94) and periodontal diseases(0.93) were above the average, and their scores in knowledge of dental caries(0.70) and blunting of taste(0.77) were below the average. 4. The seventh graders got the best score of 5.28 in smoking-related oral health knowledge(p<0.01), and the students who were more satisfied with their life had a better oral health knowledge(p<0.05). 5. The senior students were more dependent on nicotine(p<0.01), and the number of smoking days(${\beta}=0.407$, p<0.001) and the period of smoking(${\beta}=0.235$, p<0.01) affected their nicotine dependence.

Dose Distribution and Design of Dynamic Wedge Filter for 3D Conformal Radiotherapy (방사선 입체조형치료를 위한 동적쐐기여과판의 고안과 조직내 선량분포 특성)

  • 추성실
    • Progress in Medical Physics
    • /
    • v.9 no.2
    • /
    • pp.77-88
    • /
    • 1998
  • Wedge shaped isodoses are desired in a number of clinical situations. Hard wedge filters have provided nominal angled isodoses with dosimetric consequences of beam hardening, increased peripheral dosing, nonidealized gradients at deep depths along with the practical consequendes of filter handling and placement problems. Dynamic wedging uses a combination of a moving collimator and changing monitor dose to achieve angled isodoses. The segmented treatment tables(STT) that monitor unit setting by every distance of moving collimator, was induced by numerical formular. The characteristics of dynamic wedge by STT compared with real dosimetry. Methods and Materials : The accelerator CLINAC 2100C/D at Yonsei Cancer Center has two photon energies (6MV and 10MV), currently with dynamic wedge angles of 15$^{\circ}$, 30$^{\circ}$, 45$^{\circ}$ and 60$^{\circ}$. The segmented treatment tables(STT) that drive the collimator in concert with a changing monitor unit are unique for field sizes ranging from 4.0cm to 20.0cm in 0.5cm steps. Transmission wedge factors were measured for each STT with an standard ion chamber. Isodose profiles, isodose curves, percentage depth dose for dynamic wedge filters were measured with film dosimetry. Dynamic wedge angle by STT was well coincident with film dosimetry. Percent depth doses were found to be closer to open field but more shallow than hard wedge filter. The wedge transmission factor were decreased by increased the wedge angle and more higher than hard wedge filters. Dynamic wedging probided more consistent gradients across the field compared with hard wedge filters. Dynamic wedging has practical and dosimetric advantages over hard filters for rapid setup and keeping from table collisions. Dynamic wedge filters are positive replacement for hard filters and introduction of dynamic conformal radiotherapy and intensity modulation radiotherapy in a future.

  • PDF

Dosimetric Analysis of Respiratory-Gated RapidArc with Varying Gating Window Times (호흡연동 래피드아크 치료 시 빔 조사 구간 설정에 따른 선량 변화 분석)

  • Yoon, Mee Sun;Kim, Yong-Hyeob;Jeong, Jae-Uk;Nam, Taek-Keun;Ahn, Sung-Ja;Chung, Woong-Ki;Song, Ju-Young
    • Progress in Medical Physics
    • /
    • v.26 no.2
    • /
    • pp.87-92
    • /
    • 2015
  • The gated RapidArc may produce a dosimetric error due to the stop-and-go motion of heavy gantry which can misalign the gantry restart position and reduce the accuracy of important factors in RapidArc delivery such as MLC movement and gantry speed. In this study, the effect of stop-and-go motion in gated RapidArc was analyzed with varying gating window time, which determines the total number of stop-and-go motions. Total 10 RapidArc plans for treatment of liver cancer were prepared. The RPM gating system and the moving phantom were used to set up the accurate gating window time. Two different delivery quality assurance (DQA) plans were created for each RapidArc plan. One is the portal dosimetry plan and the other is MapCHECK2 plan. The respiratory cycle was set to 4 sec and DQA plans were delivered with three different gating conditions: no gating, 1-sec gating window, and 2-sec gating window. The error between calculated dose and measured dose was evaluated based on the pass rate calculated using the gamma evaluation method with 3%/3 mm criteria. The average pass rates in the portal dosimetry plans were $98.72{\pm}0.82%$, $94.91{\pm}1.64%$, and $98.23{\pm}0.97%$ for no gating, 1-sec gating, and 2-sec gating, respectively. The average pass rates in MapCHECK2 plans were $97.80{\pm}0.91%$, $95.38{\pm}1.31%$, and $97.50{\pm}0.96%$ for no gating, 1-sec gating, and 2-sec gating, respectively. We verified that the dosimetric accuracy of gated RapidArc increases as gating window time increases and efforts should be made to increase gating window time during the RapidArc treatment process.

Comparison of Dose Distributions Calculated by Anisotropic Analytical Algorithm and Pencil Beam Convolution Algorithm at Tumors Located in Liver Dome Site (간원개에 위치한 종양에 대한 Anisotropic Analyticalal Algorithm과 Pencil Beam Convolution 알고리즘에 따른 전달선량 비교)

  • Park, Byung-Do;Jung, Sang-Hoon;Park, Sung-Ho;Kwak, Jeong-Won;Kim, Jong-Hoon;Yoon, Sang-Min;Ahn, Seung-Do
    • Progress in Medical Physics
    • /
    • v.23 no.2
    • /
    • pp.106-113
    • /
    • 2012
  • The purpose of this study is to evaluate the variation of radiation dose distribution for liver tumor located in liver dome and for the interest organs(normal liver, kidney, stomach) with the pencil beam convolution (PBC) algorithm versus anisotropic Analyticalal algorithm (AAA) of the Varian Eclipse treatment planning system, The target volumes from 20 liver cancer patients were used to create treatment plans. Treatment plans for 10 patients were performed in Stereotactic Body Radiation Therapy (SBRT) plan and others were performed in 3 Dimensional Conformal Radiation Therapy (3DCRT) plan. dose calculation was recalculated by AAA algorithm after dose calculation was performed by PBC algorithm for 20 patients. Plans were optimized to 100% of the PTV by the Prescription Isodose in Dose Calculation with the PBC algorithm. Plans were recalculated with the AAA, retaining identical beam arrangements, monitor units, field weighting and collimator condition. In this study, Total PTV was to be statistically significant (SRS: p=0.018, 3DCRT: p=0.006) between PBC and AAA algorithm. and in the case of PTV, ITV in liver dome, plans for 3DCRT were to be statistically significant respectively (p=0.013, p=0.024). normal liver and kidney were to be statistically significant (p=0.009, p=0.037). For the predictive index of dose variation, CVF ratio was to be statistically significant for PTV in the liver dome versus PTV (SRS r=0.684, 3DCRT r=0.732, p<0.01) and CVF ratio for Tumor size was to be statistically significant (SRS r=-0.193, p=0.017, 3DCRT r=0.237, p=0.023).

Analysis on the Dosimetric Characteristics of Tangential Breast Intensity Modulated Radiotherapy (유방암의 접선 세기조절 방사선치료 선량 특성 분석)

  • Yoon, Mee Sun;Kim, Yong-Hyeob;Jeong, Jae-Uk;Nam, Taek-Keun;Ahn, Sung-Ja;Chung, Wong-Ki;Song, Ju-Young
    • Progress in Medical Physics
    • /
    • v.23 no.4
    • /
    • pp.219-228
    • /
    • 2012
  • The tangential breast intensity modulated radiotherapy (T-B IMRT) technique, which uses the same tangential fields as conventional 3-dimensional conformal radiotherapy (3D-CRT) plans with physical wedges, was analyzed in terms of the calculated dose distribution feature and dosimetric accuracy of beam delivery during treatment. T-B IMRT plans were prepared for 15 patients with breast cancer who were already treated with conventional 3D-CRT. The homogeneity of the dose distribution to the target volume was improved, and the dose delivered to the normal tissues and critical organs was reduced compared with that in 3D-CRT plans. Quality assurance (QA) plans with the appropriate phantoms were used to analyze the dosimetric accuracy of T-B IMRT. An ionization chamber placed at the hole of an acrylic cylindrical phantom was used for the point dose measurement, and the mean error from the calculated dose was $0.7{\pm}1.4%$. The accuracy of the dose distribution was verified with a 2D diode detector array, and the mean pass rate calculated from the gamma evaluation was $97.3{\pm}2.9%$. We confirmed the advantages of a T-B IMRT in the dose distribution and verified the dosimetric accuracy from the QA performance which should still be regarded as an important process even in the simple technique as T-B IMRT in order to maintain a good quality.

Antioxidant activities of commonly used Brassica spp. sprout vegetables in Korea (국내 다소비 십자화과 새싹채소 추출물의 항산화 활성)

  • Shin, Gi-Hae;Lee, Young-Jun;Kim, Jae-Hwan;Kim, Young-Hyoun;Kim, Dan-Bi;Lee, Jong Seok;Lim, Jeong-Ho;Lee, Ok-Hwan
    • Food Science and Preservation
    • /
    • v.21 no.4
    • /
    • pp.587-592
    • /
    • 2014
  • Brassica spp. vegetables have been known to have biological activities such as anti-cancer and anti-inflammatory activities. In this study, we investigated the in vitro physicochemical characteristics and antioxidant activities of commonly used Brassica spp. sprout vegetables such as kohlabi (Brassica oleracea var. gongyloides), red radish (Raphanussativus L. var. sativus), broccoli (B. oleracea var. italica), cabbage (B. rapavar. glabra Regel), rape (B. napus), radish (R. sativus), and tatsoi (B. campestris var. narinosa) sprouts. Our results showed that the vegetables with the highest total phenolics contents were the radish sprout ($24.40{\pm}1.24mg\;TAE/g$) and kohlabi sprout extracts ($23.97{\pm}0.46mg\;TAE/g$). Furthermore, the vegetable with the highest total flavonoid content was the radish sprout extract ($15.30{\pm}1.35mg\;CE/g$). However, the kohlabi sprout extract showed the highest DPPH radical scavenging value ($IC_{50}=1.95mg/mL$) and ORAC value (79.03 mM TE/g). In addition,the six kinds of Brassica spp. sprout vegetable extracts, except tatsoi, significantly inhibited the reactive oxygen species (ROS) production and showed that intracellular oxidative stress is closely related tothe accumulation of differentiated adipocytes and fat during the adipogenesis of 3T3-L1 preadipocytes. These results suggest that Brassica spp. sprout vegetables, especially kohlabi and radish sprout extracts, can be used to develop natural antioxidants.

A Study on the Status of Recognition and Practical Application of Oral Hygiene Devices : with outpatient as the central figure (치과병·의원 내원환자의 구강위생용품에 대한 인지도 및 사용실태에 관한 연구)

  • Kim, Soo-Kyung
    • Journal of dental hygiene science
    • /
    • v.2 no.2
    • /
    • pp.95-103
    • /
    • 2002
  • This study was carried out to investigate recognition level and practical application status of oral hygiene devices through making a survey of Seoul inhabitants. And survey was implemented in order to propose oral hygiene device for household health care activities. The following results were obtained by analyzing personal interviews of 347 commuting patients at two university hospitals and seven dental clinics. 1) The average length of toothbrush head was estimated as 22.3 mm and average changing cycle was 2.3 months. The user ratio of flat-headed brush was estimated as 51.9% and 46.7% were using fluoridated toothpaste. 2) Generally the ratio of toothpick users was higher than other device users. But the user ratio of dental floss was higher than toothpick in case of patients under orthodontic treatment. 3) The patients under orthodontic treatment were not familiar with handling orthodontic toothbrush. Though 45.8% among orthodontic patients recognized this type of toothbrush, only 25.4% of them knew how exactly to use it. 4) It was shown very low user ratio of oral hygiene devices that the patients who had periodontal problem, hypersensitive trouble, halitosis, implant or denture 5) The patients who had halitosis showed the highest user ratio of toothpick. The patients who had separation of teeth showed the highest user ratio of dental floss. The patients who're under orthodontic treatment showed the highest user ratio of interproximal brush and motorized brush. 6) In response to the most interesting dental disease, it's surveyed as follows; 60.3% of dental caries, 24.0% of periodontal disease, 14.8% of false occlusion and 0.9% of oral cancer. 7) Regarding the motivation of using those oral hygiene devices, 45% responded that it was because of recommendation by dental clinics. Among the negative answers, 38.6% responded that it was because of no selection guidance. 31.3% answered that they didn't use hygiene device because it's inconvenient. 12.0% answered that it's difficult to buy and expensive. 7.8% responded that they didn't feel significant improvement. 4.8% answered that dental hospitals and clinics didn't even introduce those hygiene devices. Therefore efficient campaign for those hygiene devices over all Korea nation should be developed and education program must be prepared for each case of patients in every dental hospitals and clinics.

  • PDF