• Title/Summary/Keyword: Camera Work

Search Result 500, Processing Time 0.025 seconds

Flow Pattern Analysis of Artificial Valves Using High Speed Camera and Image Processing Technique (고속 사진기와 영상처리 기법을 이용한 인공판막의 흐름 분석.)

  • Lee, Dong-Hyeok;Kim, Hee-Chan;Seo, Soo-Won;Min, Byoung-Goo
    • Proceedings of the KOSOMBE Conference
    • /
    • v.1993 no.11
    • /
    • pp.81-84
    • /
    • 1993
  • Artificial Heart Valve is the one of the most important artificial organ which has been implanted to many patients. The most important problems related to the artificial heart valve prosthesis are thrombosis and hemolysis. Usual method to test against this problem in vivo experiment, which is complex and hard work. Nowadays the request for In vitro Artificial Heart Valve testing system is increasing. Several papers has announced us flow pattern of Artificial Heart Valve is highly correlated with thrombosis and hemolysis. They usually gel flow pattern by LDA, it is also hard work and has narrow measuring region. In this reason we have determined to develop PTV(Particle Tracking Velocimetry). By using High-speed camera and image processing technique, flow pattern could be relatively easily obtained. Parachute and Bileaflet Artificial Heart Valve designed by SNU were testified.

  • PDF

Speeding up the KLT Tracker for Real-time Image Georeferencing using GPS/INS Data

  • Tanathong, Supannee;Lee, Im-Pyeong
    • Korean Journal of Remote Sensing
    • /
    • v.26 no.6
    • /
    • pp.629-644
    • /
    • 2010
  • A real-time image georeferencing system requires all inputs to be determined in real-time. The intrinsic camera parameters can be identified in advance from a camera calibration process while other control information can be derived instantaneously from real-time GPS/INS data. The bottleneck process is tie point acquisition since manual operations will be definitely obstacles for real-time system while the existing extraction methods are not fast enough. In this paper, we present a fast-and-automated image matching technique based on the KLT tracker to obtain a set of tie-points in real-time. The proposed work accelerates the KLT tracker by supplying the initial guessed tie-points computed using the GPS/INS data. Originally, the KLT only works effectively when the displacement between tie-points is small. To drive an automated solution, this paper suggests an appropriate number of depth levels for multi-resolution tracking under large displacement using the knowledge of uncertainties the GPS/INS data measurements. The experimental results show that our suggested depth levels is promising and the proposed work can obtain tie-points faster than the ordinary KLT by 13% with no less accuracy. This promising result suggests that our proposed algorithm can be effectively integrated into the real-time image georeferencing for further developing a real-time surveillance application.

Case Study Color Analysis of Work Clothes and Industrial Factories for Coordinating Environment Planning -Focus on Shipbuilding Companies- (통합환경 계획을 위한 작업복과 작업현장의 색채실태 사례연구 -조선업체를 중심으로-)

  • Park, Hye-Won
    • Journal of the Korean Society of Clothing and Textiles
    • /
    • v.34 no.3
    • /
    • pp.540-552
    • /
    • 2010
  • This research forms preliminary data for the coordination of environmental color planning in industry through a color analysis of work clothes and the work environment. A digital camera was used to study the work environment of two major shipbuilding companies located in Geoje city and Goseong county. The picture data was analyzed as G (ground: environment) and F (figure: clothes), and analyzed hue, value, and the chroma value through a Muncell conversion 9.0.6 from the color cluster, number of pixel, and RGB value. The results are as follows: First, GY, Y color were mostly used in the shipbuilding environment and work clothes. The color value was used in a relatively wide range but very low chroma (0-3), dark grayish, grayish tone dominated both fields. Second, the use of limited colors cannot be secured for safety in attention of the shipbuilding field. Third, unclear and vogue colors lessened the optical tiredness of workers that helped in the prevention of industrial accidents. Color combination and color selection should be considered for a secure safety color coordination between work clothes and the work environment when it comes to complicated color principles.

Study on Behavior Analysis of Crash Cushion Using Analysis Data of High-Speed Camera (고속카메라 영상분석 데이타를 이용한 충격흡수시설의 충돌거동 분석에 관한 연구)

  • Jang, Dae-Young;Ko, Man-Gi;Lee, Yoon-Ki;Joo, Jae-Woong
    • International Journal of Highway Engineering
    • /
    • v.11 no.2
    • /
    • pp.75-83
    • /
    • 2009
  • Collision behavior of clash cushion occurs for a second of less than 0.4sec usually so that it is too hard to calculate numerically. Therefore, for development of trash cushion, it rely on full-scale vehicle crash test without any design procedure. Occupant safety indices if calculated from acquired data by data measurement system and collision behavior of vehicle and crash cushion is filming using high-speed camera in the crash test. But practical ufo scope of high-speed camera is limited and it is not using to calculated the occupant safety indices or analyzed the energy dissipated mechanism of crash cushion. This work is to estimate to be suitable or not for compare the data from measurement system with the data from high-speed camera. And also it is to grope for practical use scheme to calculation of occupant safety indices or analysis of collision behavior.

  • PDF

Damage Degree Valuation of Forest Using NDVI from Near Infrared CCD Camera and Spectral Radiometer in a Forest Fire Area (근적외 CCD카메라와 분광반사계의 식생지수를 이용한 산불 발생지역에서의 산림 피해도 평가)

  • Choi, Seung-Pil;Kim, Dong-Hee;Park, Jong-Sun
    • Journal of the Korean Society of Surveying, Geodesy, Photogrammetry and Cartography
    • /
    • v.23 no.4
    • /
    • pp.367-374
    • /
    • 2005
  • Recently, forest damage has occurred often and made big issues. Among them, the damage by forest fire is not only damage of itself but also being connected with secondary damage like a flood. This is the fact that a forest fire is caused rather artificially by people than nature. In this study, we try to investigate damage of a forest fire through spectral reflectance of a plant community surveyed using a near infrared CCD camera and a SPM (Spectral Radiometer) as advanced work to use satellite image data. That is, damage of a forest fire by the naked eye observation was divided into the No damage, the light damage, the serious damage and we estimated activity of forest and grasped revival possibility of forest. Through correlation analysis between the spectral reflectance by SPM and the near infrared CCD camera, we could get high correlation in the No damage and light damage. Therefore, when we surveyed damage of a forest fire, we could grasp damage, that is hardly observed by the naked eye by, using jointly the spectral radiometer and the near infrared CCD camera.

Depthmap Generation with Registration of LIDAR and Color Images with Different Field-of-View (다른 화각을 가진 라이다와 칼라 영상 정보의 정합 및 깊이맵 생성)

  • Choi, Jaehoon;Lee, Deokwoo
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.21 no.6
    • /
    • pp.28-34
    • /
    • 2020
  • This paper proposes an approach to the fusion of two heterogeneous sensors with two different fields-of-view (FOV): LIDAR and an RGB camera. Registration between data captured by LIDAR and an RGB camera provided the fusion results. Registration was completed once a depthmap corresponding to a 2-dimensional RGB image was generated. For this fusion, RPLIDAR-A3 (manufactured by Slamtec) and a general digital camera were used to acquire depth and image data, respectively. LIDAR sensor provided distance information between the sensor and objects in a scene nearby the sensor, and an RGB camera provided a 2-dimensional image with color information. Fusion of 2D image and depth information enabled us to achieve better performance with applications of object detection and tracking. For instance, automatic driver assistance systems, robotics or other systems that require visual information processing might find the work in this paper useful. Since the LIDAR only provides depth value, processing and generation of a depthmap that corresponds to an RGB image is recommended. To validate the proposed approach, experimental results are provided.

Real Time Pothole Detection System based on Video Data for Automatic Maintenance of Road Surface Distress (도로의 파손 상태를 자동관리하기 위한 동영상 기반 실시간 포트홀 탐지 시스템)

  • Jo, Youngtae;Ryu, Seungki
    • KIISE Transactions on Computing Practices
    • /
    • v.22 no.1
    • /
    • pp.8-19
    • /
    • 2016
  • Potholes are caused by the presence of water in the underlying soil structure, which weakens the road pavement by expansion and contraction of water at freezing and thawing temperatures. Recently, automatic pothole detection systems have been studied, such as vibration-based methods and laser scanning methods. However, the vibration-based methods have low detection accuracy and limited detection area. Moreover, the costs for laser scanning-based methods are significantly high. Thus, in this paper, we propose a new pothole detection system using a commercial black-box camera. Normally, the computing power of a commercial black-box camera is limited. Thus, the pothole detection algorithm should be designed to work with the embedded computing environment of a black-box camera. The designed pothole detection algorithm has been tested by implementing in a black-box camera. The experimental results are analyzed with specific evaluation metrics, such as sensitivity and precision. Our studies confirm that the proposed pothole detection system can be utilized to gather pothole information in real-time.

A Study of Optical System Design for a Retinal Camera (망막 카메라용 광학계 설계)

  • Hong, Kyung-Hee
    • Korean Journal of Optics and Photonics
    • /
    • v.17 no.2
    • /
    • pp.113-119
    • /
    • 2006
  • We need a good image of the retina of the human eye in order to inspect or cure it. In this work, an optical system design for a retinal camera is studied and the finite schematic eye model made by Sang Gee Kim and Sung Chan Park is used. The optical system is composed of four lens groups. The rays of the entire object field are collected on the center by the 1st group and the objective is imaged by all the other groups. The image is detected by the CCD array and displayed by a monitor The 1st lens group is employed singlet and other groups are employed triplets. Ray aberrations, spot diagrams, diffraction line spread functions and MTFs are calculated for optical performance assessment. This design may be very useful for the development of a retinal camera with high performance.

Uncooled Microbolometer FPA Sensor with Wafer-Level Vacuum Packaging (웨이퍼 레벨 진공 패키징 비냉각형 마이크로볼로미터 열화상 센서 개발)

  • Ahn, Misook;Han, Yong-Hee
    • Journal of Sensor Science and Technology
    • /
    • v.27 no.5
    • /
    • pp.300-305
    • /
    • 2018
  • The uncooled microbolometer thermal sensor for low cost and mass volume was designed to target the new infrared market that includes smart device, automotive, energy management, and so on. The microbolometer sensor features 80x60 pixels low-resolution format and enables the use of wafer-level vacuum packaging (WLVP) technology. Read-out IC (ROIC) implements infrared signal detection and offset correction for fixed pattern noise (FPN) using an internal digital to analog convertor (DAC) value control function. A reliable WLVP thermal sensor was obtained with the design of lid wafer, the formation of Au80%wtSn20% eutectic solder, outgassing control and wafer to wafer bonding condition. The measurement of thermal conductance enables us to inspect the internal atmosphere condition of WLVP microbolometer sensor. The difference between the measurement value and design one is $3.6{\times}10-9$ [W/K] which indicates that thermal loss is mainly on account of floating legs. The mean time to failure (MTTF) of a WLVP thermal sensor is estimated to be about 10.2 years with a confidence level of 95 %. Reliability tests such as high temperature/low temperature, bump, vibration, etc. were also conducted. Devices were found to work properly after accelerated stress tests. A thermal camera with visible camera was developed. The thermal camera is available for non-contact temperature measurement providing an image that merged the thermal image and the visible image.

A Method for Quantitative Measurement of Lateral Flow Immunoassay Using Color Camera (컬러 카메라를 이용한 측면유동 면역 어세이 정량분석 방법)

  • Park, Jongwon
    • Journal of Biomedical Engineering Research
    • /
    • v.35 no.1
    • /
    • pp.1-7
    • /
    • 2014
  • Among semi-quantitative or fully quantitative lateral flow assay readers, an image sensor-based instrument has been widely used because of its simple setup, cheap sensor price, and compact equipment size. For all previous approaches, monochrome CCD or CMOS cameras were used for lateral flow assay imaging in which the overall intensities of all colors were taken into consideration to estimate the analyte content, although the analyte related color information is only limited to a narrow wavelength range. In the present work, we introduced a color CCD camera as a sensor and a color decomposition method to improve the sensitivity of the quantitative biosensor system which utilizes the lateral flow assay successfully. The proposed setup and image processing method were applied to achieve the quantification of imitatively dispensed particles on the surface of a porous membrane first, and the measurement result was then compared with that using a monochrome CCD. The compensation method was proposed in different illumination conditions. Eventually, the color decomposition method was introduced to the commercially available lateral flow immunochromatographic assay for the diagnosis of myocardial infarction. The measurement sensitivity utilizing the color image sensor is significantly improved since the slopes of the linear curve fit are enhanced from 0.0026 to 0.0040 and from 0.0802 to 0.1141 for myoglobin and creatine kinase (CK)-MB detection, respectively.