• Title/Summary/Keyword: Cam Analysis

Search Result 598, Processing Time 0.03 seconds

The Study on Marginal discrepancy of Manufactured Coping Crown according to Production method and materials by using CAD/CAM System (CAD/CAM System을 활용하여 제작된 Coping Crown의 제작방식 및 재료에 따른 변연 적합도에 관한 연구)

  • Lee, Hee-Sung;Shin, Seong-Hun;Song, Joon-Ki
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.18 no.10
    • /
    • pp.448-453
    • /
    • 2017
  • The purpose of this study was to compare the marginal discrepancy of coping crowns according to manufacturing method and materials by using the CAD/CAM system to compare the optimum manufacturing method and materials. The coping crowns were fabricated by using manufacturing methods and materials, and marginal fit was measured using the replica technique. For comparative analysis of manufacturing methods and materials, analysis of variance was performed. One-way ANOVA was performed to compare and analyze different mean values. For the milling method of the alloy, 114.6 was obtained for the MM group, 111.4 for the MS group, 67.2 for the MSC group, and 50.9 for the MSS group, respectively, using the milling/sintering method. In the milling/sintering method of ceramic, 35.6 and 36.3, respectively, were obtained for the SLME group and SLMR group, respectively. However,there was a significant difference according to the material. The milling/sintering method of the ceramic material gave the lowest value, and it was verified by the optimal method. However, marginal discrepancy of coping crowns fabricated using the CAD/CAM system is applicable to the clinic since it corresponds to acceptable numerical values in clinical practice.

Comparison of flexural strength according to thickness between CAD/CAM denture base resins and conventional denture base resins (CAD/CAM 의치상 레진과 열중합 의치상 레진의 두께에 따른 굴곡 강도 비교)

  • Lee, Dong-Hyung;Lee, Joon-Seok
    • Journal of Dental Rehabilitation and Applied Science
    • /
    • v.36 no.3
    • /
    • pp.183-195
    • /
    • 2020
  • Purpose: The purpose of this study is to compare the flexural strength of CAD/CAM denture base resins with conventional denture base resins based on their thicknesses. Materials and Methods: For the conventional denture base resins, Lucitone 199® (C-LC) was used. DIOnavi - Denture (P-DO) and DENTCA Denture Base II (P-DC) were taken for the 3D printing denture base resins. For the prepolymerized PMMA resins, Vipi Block Gum (M-VP) and M-IVoBase® CAD (M-IV) were used. The final dimensions of the specimens were 65.0 mm x 12.7 mm x 1.6 mm / 2.0 mm / 2.5 mm. The 3-point bend test was implemented to measure the flexural strength and flexural modulus. Microscopic evaluation of surface of fractured specimen was conducted by using a scanning electron microscope (SEM). After testing the normality of the data, one-way ANOVA was adopted to evaluate the differences among sample groups with a significance level of P = 0.05. The Tukey HSD test was performed for post hoc analysis. Results: Under the same thicknesses, there are significant differences in flexural strength between CAD/CAM denture base resins and conventional denture base resins except for P-DO and C-LC. M-VP showed higher flexural strength than conventional denture base resins, P-DC and M-IV displayed lower flexural strength than conventional denture base resins. Flexural modulus was highest in M-VP, followed by C-LC, P-DO, P-DC, M-IV, significant differences were found between all materials. In the comparison of flexural strength according to thickness, flexural strength of 2.5 mm was significantly higher than that of 1.6 mm in C-LC. Flexural strength of 2.5 mm and 2.0 mm was significantly higher than that of 1.6 mm in P-DC and M-VP. In M-IV, as the thickness increases, significant increase in flexural strength appeared. SEM analysis illustrates different fracture surfaces of the specimens. Conclusion: The flexural strength of different CAD/CAM denture base resins used in this study varied according to the composition and properties of each material. The flexural strength of CAD/CAM denture base resins was higher than the standard suggested by ISO 20795-1:2013 at a thickness of 1.6 mm or more though the thickness decreased. However, for clinical use of dentures with lower thickness, further researches should be done regarding other properties at lower thickness of denture base resins.

Influence analysis of continuous pile walls on the behavior of a soil tunnel at the shallow depth through a parametric study (민감도 분석을 통한 주열식벽체가 저토피 토사터널 거동에 미치는 영향 분석)

  • You, Kwang-Ho;Yoon, Woo-Jin
    • Journal of Korean Tunnelling and Underground Space Association
    • /
    • v.16 no.1
    • /
    • pp.75-89
    • /
    • 2014
  • In recent years, utilization of underground space has been increasing in various parts of the world. In particular, open-cut method is usually applied to the shallow depth excavation. However some problems such as extreme traffic congestion and unstability of adjacent structures etc. might occur. In order to cope with these problems, the M-CAM (Modified Cellular Arch Method) method was proposed to excavate soil tunnels at shallow depth with secured enough stability and minimized construction period. In this study, sensitivity analysis was performed to predict the influence of the size of CPW(Continuous Pile Wall) and ground conditions on the behavior of the tunnel. First of all, embedded depth and diameter (or thickness) of CPW, coefficient of lateral earth pressure, and ground conditions were selected as parameters that could affect tunnel stability. Meanwhile, FLAC 2D based on finite difference method was used for numerical analysis. As a result of this study, it was checked out that embedded depth among sizes of CPW had a greatest influence on the stability of a tunnel.

Biomechanical behavior of CAD/CAM cobalt-chromium and zirconia full-arch fixed prostheses

  • Barbin, Thais;Silva, Leticia Del Rio;Veloso, Daniele Valente;Borges, Guilherme Almeida;Presotto, Anna Gabriella Camacho;Barao, Valentim Adelino Ricardo;Groppo, Francisco Carlos;Mesquita, Marcelo Ferraz
    • The Journal of Advanced Prosthodontics
    • /
    • v.12 no.6
    • /
    • pp.329-337
    • /
    • 2020
  • PURPOSE. To verify the influence of computer-aided design/computer-aided manufacturing (CAD/CAM) implant-supported prostheses manufactured with cobalt-chromium (Co-Cr) and zirconia (Zr), and whether ceramic application, spark erosion, and simulation of masticatory cycles modify biomechanical parameters (marginal fit, screw-loosening torque, and strain) on the implant-supported system. MATERIALS AND METHODS. Ten full-arch fixed frameworks were manufactured by a CAD/CAM milling system with Co-Cr and Zr (n=5/group). The marginal fit between the abutment and frameworks was measured as stated by single-screw test. Screw-loosening torque evaluated screw stability, and strain analysis was explored on the implant-supported system. All analyses were performed at 3 distinct times: after framework manufacturing; after ceramic application in both materials' frameworks; and after the spark erosion in Co-Cr frameworks. Afterward, stability analysis was re-evaluated after 106 mechanical cycles (2 Hz/150-N) for both materials. Statistical analyses were performed by Kruskal-Wallis and Dunn tests (α=.05). RESULTS. No difference between the two materials was found for marginal fit, screwloosening torque, and strain after framework manufacturing (P>.05). Ceramic application did not affect the variables (P>.05). Spark erosion optimized marginal fit and strain medians for Co-Cr frameworks (P<.05). Screw-loosening torque was significantly reduced by masticatory simulation (P<.05) regardless of the framework materials. CONCLUSION. Co-Cr and Zr frameworks presented similar biomechanical behavior. Ceramic application had no effect on the biomechanical behavior of either material. Spark erosion was an effective technique to improve Co-Cr biomechanical behavior on the implant-supported system. Screw-loosening torque was reduced for both materials after masticatory simulation.

Structural Analysis of S-cam Brake Shoe for Commercial Vehicle by FEM (FEM을 이용한 상용차용 S-cam 브레이크슈의 구조해석)

  • Suh, Chang-Min;Jee, Hyun-Chul
    • Journal of Ocean Engineering and Technology
    • /
    • v.23 no.4
    • /
    • pp.69-77
    • /
    • 2009
  • Structural analysis of a brake shoe for commercial vehicle was performed using finite element method. Since the strength of a brake shoe is affected by the magnitude and distribution shape of the contact pressure with the drum, the contact pressure between the shoe friction material and drum was calculated using a 2-Dimensional non-linear contact analysis in a state. And the brake was actuated by input air pressure and the drum of it was calculated both stationary and dynamic based on forced torque applied to the drum during the static state analysis. The results of the above analysis were then used as the load boundary conditions for a 3-Dimensional shoe model analysis to determine the maximum strain on the shoes. In the analysis model, the values of tensile test were used for the material properties of the brake shoes and drum, while the values of compression test were used for the friction material. We assumed it as linear variation, even though the properties of friction material were actually non-linear. The experiments were carried out under the same analysis conditions used for fatigue test and under the same brake system which equipped with a brake drum based on the actual axle state in a vehicle. The strains were measured at the same locations where the analysis was performed on the shoes. The obtained results of the experiment matched well with those from the analysis. Consequently, the model used in this study was able to determine the stress at the maximum air pressure at the braking system, thereby a modified shoe model in facilitating was satisfied with the required endurance strength in the vehicle.

Locomotion Mechanism Using a Combination Cam with Multi-Phases (다중 위상차를 갖는 조합형 캠을 이용한 다족형 이동 메커니즘)

  • Kim, Kyung-Dae;Jeong, Youn-Koo;Kim, Byung-Kyu;Park, Jong-Oh
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.26 no.12
    • /
    • pp.2598-2604
    • /
    • 2002
  • Robots that can move along the narrow and rough tube are very important as the request for the inspection increases. It is necessary for the inspection robots to have a capability to move successfully at even overturned situation and have a simple mechanism to reduce the unexpected failure possibility fer the successful completion of the given mission. Through this paper, the authors propose a novel and simple mechanism using a combination cam device to generate the locomotive motion of multi-legs. This robot uses one DC motor and one combination cam shaft to generate the locomotive motion and can move rough tubes without failure even at the overturned situation. The robot also shows enough fragging force fer the connected line that is very important for a wired inspection robot. Kinematics analysis to design the specification of the robot will be followed and several applications show this robot's potential capabilities.

THE INTEGRATION OF CAD/CAM/CAE BASED ON MULTI MODEL TECHNOLOGY IN THE DEVELOPMENT OF CYLINDER HEAD

  • Xu, Xiangyang;Weiss, Ulrich;Gao, Guoan
    • International Journal of Automotive Technology
    • /
    • v.3 no.2
    • /
    • pp.47-52
    • /
    • 2002
  • The integration of CAD/CAM/CAE in product development is the key to realize concurrent engineering. Generally, different systems are employed in product development departments. These different systems create a lot of trout)toes such as difficulty in communication, misunderstanding and so on. A new approach to integrate CAD/CAM/CAE in one system based on CATIA thor the end-to-end process in cylinder head development is presented. Hulti Model Technology (MMT) is used to create consistent and associated CAD models for the end-to-end process in cylinder head development. The concept and method to create and organize multi models are discussed. A typical four-layer structure of HHT for mechanical products is defined. The multi level structure of the cylinder head models based on MMT is provided. The CAD models of cylinder head created based on MMT can be used as the consistent model. All models in the downstream of cylinder head development such as structure analysis, CFD, sand core design , casting simulation and so oil are associated with the CAD models. Practice shows the approach in this paper enables the development process to be carried concurrently and can obviously shorten time to the market, reduce product cost and improve product quality.

Comparative Study on the Color Stability of Temporary Prosthetic Materials for Dental CAD-CAM (치과 CAD-CAM용 임시 수복재의 색 안정성 비교 연구)

  • Lee, Hye-Eun;Kim, Won-Soo;Kim, Jung-suk;Lee, Ju-hee;Won, Seuck-Jae
    • Journal of Technologic Dentistry
    • /
    • v.38 no.3
    • /
    • pp.165-173
    • /
    • 2016
  • Purpose: This study was conducted to examine the color stability of temporary prosthetic materials for dental CAD-CAM. Method: 2 kinds of existing acrylic resin temporary filling materials and 2 kinds of polymer prosthetic materials for dental CAD-CAM were used for testing, and five specimens respectively were absorbed in soy sauce, red pepper paste, and coffee. A Chroma Meter was used as analysis equipment. The color change of the specimens was observed to calculate ${\Delta}E$ value throughout 2 days, 3 days, 4 days, and 5 days and this was analyzed and the following result was obtained. Results: Snap's ${\Delta}E$ value was bigger than Vipi block(p<0.05). Red pepper paste had the largest impact on the color change of resin(${\Delta}E$), followed by soy sauce and coffee(p<0.000). With the passage of time, ${\Delta}E$ value was inversely(-) related and decreased somewhat(p<0.000).

Structure and expression analysis of the OsCam1-1 calmodulin gene from Oryza sativa L.

  • Phean-o-pas, Srivilai;Limpaseni, Tipaporn;Buaboocha, Teerapong
    • BMB Reports
    • /
    • v.41 no.11
    • /
    • pp.771-777
    • /
    • 2008
  • Calmodulin (CaM) proteins, members of the EF-hand family of $Ca^{2+}$-binding proteins, represent important relays in plant calcium signals. Here, OsCam1-1 was isolated by PCR amplification from the rice genome. The gene contains an ORF of 450 base pairs with a single intron at the same position found in other plant Cam genes. A promoter region with a TATA box at position-26 was predicted and fused to a gus reporter gene, and this construct was used to produce transgenic rice by Agrobacterium-mediated transformation. GUS activity was observed in all organs examined and throughout tissues in cross-sections, but activity was strongest in the vascular bundles of leaves and the vascular cylinders of roots. To examine the properties of OsCaM1-1, the encoding cDNA was expressed in Escherichia coli. The electrophoretic mobility shift when incubated with $Ca^{2+}$ indicates that recombinant OsCaM1-1 is a functional $Ca^{2+}$-binding protein. In addition, OsCaM1-1 bound the CaMKII target peptide confirming its likely functionality as a calmodulin.

Determining the optimal range of vitamin C for early red drum (Sciaenops ocellatus) juveniles

  • Nguyen Thi Thuy;Khuong V. Dinh;Ngo Van Manh;Trung Si Trang
    • Fisheries and Aquatic Sciences
    • /
    • v.26 no.9
    • /
    • pp.525-534
    • /
    • 2023
  • Vitamin C plays an important role for fish survival, growth and disease resistance. However, the optimal vitamin C for rearing red drum Sciaenops ocellatus juveniles in Vietnam is not known. To address this issue, a 70-day feeding trial was conducted to evaluate the optimal dietary vitamin C requirements for red drum juveniles. Seven isonitrogenous (55.35% protein) and isolipidic (9.07% lipid) diets were formulated to include graded vitamin C concentrations of 23.2, 124.5, 235.2, 423.8, 626.7, 824.6, and 1,027.3 mg/kg, respectively. The results showed that fish fed on 423.8 mg/kg vitamin C diet had the highest growth rate, which can be linked to the increased feed utilization. Broken-line analysis indicated that the optimal dietary vitamin C requirements of red drum juveniles were 342.92 and 405.80 mg/kg for growth parameters, feed utilization, body composition and biochemical parameters of serum. Based on these parameters the optimal vitamin C supplementation level for red drum juveniles was estimated in the range of 342.92-405.80 mg/kg vitamin C in the diets with direct applications in producing artificial feed for rearing juveniles of this species in Vietnam.