• 제목/요약/키워드: Caliper measurement

검색결과 55건 처리시간 0.033초

Effect of slice inclination and object position within the field of view on the measurement accuracy of potential implant sites on cone-beam computed tomography

  • Saberi, Bardia Vadiati;Khosravifard, Negar;Nourzadeh, Alireza
    • Imaging Science in Dentistry
    • /
    • 제50권1호
    • /
    • pp.37-43
    • /
    • 2020
  • Purpose: The purpose of this study was to evaluate the accuracy of linear measurements in the horizontal and vertical dimensions based on object position and slice inclination in cone-beam computed tomography (CBCT) images. Materials and Methods: Ten dry sheep hemi-mandibles, each with 4 sites (incisor, canine, premolar, and molar), were evaluated when either centrally or peripherally positioned within the field of view (FOV) with the image slices subjected to either oblique or orthogonal inclinations. Four types of images were created of each region: central/cross-sectional, central/coronal, peripheral/cross-sectional, and peripheral/coronal. The horizontal and vertical dimensions were measured for each region of each image type. Direct measurements of each region were obtained using a digital caliper in both horizontal and vertical dimensions. CBCT and direct measurements were compared using the Bland-Altman plot method. P values <0.05 were considered to indicate statistical significance. Results: The buccolingual dimension of the incisor and premolar areas and the height of the incisor, canine, and molar areas showed statistically significant differences on the peripheral/coronal images compared to the direct measurements (P<0.05). Molar area height in the central/coronal slices also differed significantly from the direct measurements (P<0.05). Cross-sectional images of either the central or peripheral position had no marked difference from the gold-standard values, indicating sufficient accuracy. Conclusion: Peripheral object positioning within the FOV in combination with applying an orthogonal inclination to the slices resulted in significant inaccuracies in the horizontal and vertical measurements. The most undesirable effect was observed in the molar area and the vertical dimension.

CEREC$^{(R)}$ AC system으로 채득된 디지털 인상의 재현성, 정확성 평가에 관한 연구 (Reliability, accuracy of evaluations obtained from CEREC$^{(R)}$ AC system digital impression: an in-vitro study)

  • 김재홍;김기백;김혜영;김정애;김웅철;김지환
    • 대한치과기공학회지
    • /
    • 제34권2호
    • /
    • pp.121-128
    • /
    • 2012
  • Purpose: The aim of this study was to determine the reliability and accuracy of measurements in digital models(CEREC$^{(R)}$ AC) compared to stone models. Methods: A master model(500B-1, Nissin Dental Product, Japan) with the prepared upper full arch tooth was used. Conventional impression and then stone model(n=10) were produced from this master model, and on the other hands, digital impressions were made with the CEREC$^{(R)}$ AC intra-oral scanner(n=10). One examiner measured two times the intercanine, intermolar distance, dental arch length. The stone model were measured using a digital caliper. The t-student test for paired samples and intraclass correlation coefficient(ICC) were used for statistical analysis. Results: The measurement of two methods showed very good reliability. At the intra-examiner reliability of measurement, ICC at the stone and CEREC$^{(R)}$ AC model were 0.81 and 0.94. The mean difference between measurements made directly on the stone models and those made on the CEREC$^{(R)}$ AC model was 0.20~0.28mm, and was statistically significant(P=0.001). Conclusion: These in vitro studies show that accuracy of the digital impression is similar to that of the conventional impression. These results will have to be confirmed in further clinical studies.

초음파상을 이용한 제주마의 난소, 난포 및 황체의 크기 측정 (Measurement of Size of Ovaries, Follicles, and Corpus Lutea by Ultrasonography with Jeju Horse)

  • 유재규;강민수;손우진;윤영민;이주명;강태영
    • 한국수정란이식학회지
    • /
    • 제22권3호
    • /
    • pp.191-194
    • /
    • 2007
  • 본 연구는 도축된 제주마의 난소를 이용하여 초음파 유도난포란 채취 기술을 확립하고자 난소, 난포 및 황체의 크기를 초음파상과 육안적 측정치를 비교하고자 하였다. 초음파상 측정치와 caliper를 이용한 실제 크기의 측정치 비교에서는 통계학적 차이는 보이지 않았다. 배란 직전의 난포를 조사한 결과, 초음파상에서 관찰한 것은 난소 한 개 당 평균 0.83개와 평균 크기는 2.86 m였으며, 육안으로 관찰된 것은 난소 한 개 당 평균 0.75개와 평균 크기는 2.3 cm였다. 난소 한 개 당 평균난포 수는 초음파상에서는 4.25개와 육안에서는 4.38개였다. 제주마 난소의 난포 크기 및 수를 초음파상과 육안으로 조사하였던 바, 유의적인 차이가 나타나지 않았다. 이러한 결과로 차후 초음파를 이용한 OPU와 말에서 번식 기술과 관련된 연구에 기초 정보가 제공되리라 사려된다.

코 석고모형에서 간접인체계측법의 정확성 : 직접인체계측법과의 비교 (Accuracy of Indirect Anthropometry on Cast Model of The Nose: Comparison with Direct Anthropometry)

  • 백대향;한기환;원동철;최태현;김준형;손대구
    • Archives of Plastic Surgery
    • /
    • 제35권1호
    • /
    • pp.48-55
    • /
    • 2008
  • Purpose: We measured linear distances, angles and inclinations on the cast models of the noses, and compared these indirect measurements with the direct measurements obtained from the nose in order to validate the accuracy of the indirect anthropometry using the cast model. Methods: Subjects were 50 males and 50 females, medical students in twenties(mean 27.1 years). Cast models were made from the alginate impression material and the plaster. In direct anthropometry, 16 linear, 7 angular, and 2 inclination measurements between 11 landmarks on the nose were obtained using sliding caliper, spreading caliper, and fabric tape measure. At the same time, the same measurements were obtained from the cast models of the same people. Total 25 measurements were compared, and tested by the independent t-test of SPSS. Results: The standard values of Korean nose in twenties were obtained. 24 measurements except the columellar labial angle were not statistically different between the indirect anthropometry and the direct anthropometry. Conclusion: Indirect anthropometry on the cast model of the nose revealed no significant difference from the anthropometric measurement statistically, accounting for 24 in 25 measurements(96%). There are two possible reasons that caused the difference of columellar labial angle between direct and indirect anthropometry. First, the columellar labial angle could be decreased by protrusion of the lips which resulted from contracting mouth in which an drinking straw had been applied on the mouth corner for patients' respiration during making cast model. Second, it is generally known that the columellar labial angle could be measured larger when soft tissues were pressed by protractor in direct anthropometry. Using a drinking straw with greater diameter, and scheming respiration through the nostrils that patients don't feel discomfort, the more accurate data would be obtained from the indirect anthropometry using the cast models of the noses.

비만도에 따른 사상체질별 체형 특성 분석 (A Study on the Sasang Constitutional Characteristics by Obesity Grade)

  • 여혜린;김규곤;이명희;박윤창;전수형;권석동;정성일;김종원
    • 사상체질의학회지
    • /
    • 제20권1호
    • /
    • pp.89-99
    • /
    • 2008
  • 1. Objectives The objective of this study is to offer some standards for the distinction of Sasang Constitutions through analyzing the characteristics of their body shapes that are classified by BMI. 2. Methods The subject of this study were 1341 female and 927 male patients who aged from 17 to 80 in Seoul, Pusan, Daeku and Jeonju. They were treated with Sasang Constitutional medicine. 8 circumferences, 5 widths, weight, height of their body were measured with measuring tape, large sliding caliper, scale and anthropometer. Collected 15 anthropometric datas were analyzed by Analysis of Contingency table, ANOVA and Duncan test. 3. Results (1) The Body shapes according to obesity grade are classified Underweight type that BMI is less than 18.5, Normal weight type that BMI is $18.5{\sim}23.0$ and Overweight type that BMI is mote than 23.0. (2) Soeumin represents Underweight type and Taeeumin represents Overweight type regardless of gender differences. Soeumin stands for Normal weight type in women and Soyangin stands for Normal weight type in men. (3) In case of Underweight type, 13 measurements are not suitable to estimate Sasang Constitutions regardless of gender differences. (4) In case of Normal weight type, 12 measurements except for W3 in women and W7 in men are suitable to estimate Sasang Constitutions. And there are no gender differences in Soyangin and Soeumin, but there are gender differences in Taeyangin and Taeeumin. (5) In case of Overweight type, 9 measurements except for C2, C5, C6, W7 in women and 12 measurements except for W3 in men are suitable to estimate Sasang Constitutions. And there are no gender differences in 4 Sasang Constitutions. 4. Conclusions From the above results, we have to consider not only gender differences and age groups but also obesity grade when we distinguish Sasang Constitutions.

  • PDF

목재수축률 측정에 대한 총설 (Review on The Measurement of Wood Shrinkage)

  • 이소선;소원택;정기영
    • Journal of the Korean Wood Science and Technology
    • /
    • 제43권6호
    • /
    • pp.746-756
    • /
    • 2015
  • 본 논문에서는 목재 수축률에 관한 1976-2015년도에 발표된 목재공학회지 논문을 정리하였다. 국내산 낙엽송(Larix kaempferi) 수축률을 측정한 연구자들간에 접선방향 수축률은 4.21%-9.79%, 방사방향 수축률은 2.09%-4.67%, 섬유방향 수축률은 0.17%-0.33%로 접선방향 2.3배, 방사방향 2.2배, 섬유방향 1.9배로 연구자들마다 측정 값에 차이가 나타났다. 소나무(Pinus densiflora) 시편 크기가 $20{\times}20{\times}20mm$에서 $100{\times}100{\times}100mm$로 증가함에 따라 접선방향, 방사방향, 부피수축률은 2.61%, 1.32%, 0.80% 감소하였다. 아피통(Dipterocarpus grandiflorus)을 밀폐건조, 오븐건조, 실온건조 하였을 때 부피수축률은 31.6%, 26.5%, 21.0%로 건조방법에 따라 5.5%-10.6% 차이가 나타났으며 건조온도가 $115^{\circ}C$, $120^{\circ}C$, $125^{\circ}C$로 증가함에 따라 낙엽송의 수축률은 일정한 증가, 감소 경향이 보이지 않았다. $20mm^3$ 크기의 삼나무(Cryptomeria japonica) 시편을 한국산업규격(KS F 2203, 2004)에서 제시하는 정밀도 0.01 mm의 길이측정도구로 수축률을 측정하였을 때, 방사, 섬유방향 수축률 측정오차는 1.97%, 35.7%로 크게 나타났다. 목재의 수축률은 시편 크기, 건조방법, 측정방법에 영향을 받는 것으로 나타났다.

경사진 임플란트에서 임플란트 인상의 정확도 평가를 위한 역공학 기법 (Reverse engineering technique on the evaluation of impression accuracy in angulated implants)

  • 정홍택;이기선;송소연;박진홍;이정열
    • 대한치과보철학회지
    • /
    • 제59권3호
    • /
    • pp.261-270
    • /
    • 2021
  • 목적: 본 연구의 목적은 (1) 기존에 존재하던 몇 가지 다른 임플란트 인상의 정확도 평가방법들과 역공학 기술을 비교하고 (2) 역공학 기술로 임플란트 식립 방향 및 임플란트 인상용 코핑의 종류에 따른 인상 채득의 정확도를 평가하는 것이다. 재료 및 방법: 임플란트 식립 방향에 따른 세 가지 다른 마스터 모델을 제작하였고, 그 중 임플란트를 평행하게 식립한 마스터 모델에서 두 임플란트 중심점 사이의 거리를 다음과 같은 세 가지 방법으로 측정하였다 (디지털 캘리퍼를 이용한 측정 방법(그룹 DC), 광학 사진을 이용한 측정 방법(그룹 OM) 및 역공학 기술을 이용한 측정 방법(그룹 RE)). 세 종류의 마스터 모델 별로 각각 세 가지 유형의 임프레션 코핑을 이용하여 인상을 채득한 후 총 90개의 실험 모델을 제작하였으며 각 실험 모델들과 마스터 모델 간의 각도 및 거리의 오차율(error rate)을 계산하였다. 세 가지 평가 방법 간의 비교에는 One-way ANOVA가 사용되었다 (P < .05). 각 실험 그룹들의 오차율은 two-way ANOVA를 이용하여 분석하였다 (P < .05). 결과: 그룹 DC의 오차율과 그룹 RE의 오차율 간에는 통계적으로 유의한 차이가 있었지만 (P < .05), 그룹 OM의 오차율을 다른 그룹들과 비교하였을 때는 통계적으로 유의한 차이가 없었다(P > .05). 역공학 기술로 측정한 오차율의 표준 편차는 디지털 캘리퍼 및 광학 사진 측정으로 계산한 오차율의 표준 편차보다 상당히 낮았다. 하이브리드 인상용 코핑 그룹은 거리 오차율에서 픽업 인상용 코핑 그룹과 큰 차이가 없었다 (P > .05). 결론: 본 실험을 통해 역공학 기술이 임플란트 인상의 삼차원적인 정확도 평가 기법으로서의 잠재력이 있음을 확인하였다.

유치의 치아크기에 관한 연구 (A STUDY ON THE SIZE OF THE DECIDUOUS TEETH)

  • 백병주;전소희;김재곤;김영신
    • 대한소아치과학회지
    • /
    • 제29권3호
    • /
    • pp.382-388
    • /
    • 2002
  • 전라북도 전주시 유치원 어린이 650명을 대상으로 구강내 검사 실시하여 평균 연령 4.5세 어린이 100명(남아 50명, 여아 50명)의 유치열 석고모형을 계측하여 다음과 같은 결과를 얻었다. 1. 유치의 계측자내 오차는 제1유구치에서 다소 크고, 총평균치는 0.255mm이었다. 2. 유치의 근원심 및 순(협)설측 치관 직경은 전체 유치에서 남아가 여아보다 컸다. 3. 변동계수(coefficient variation)는 남 여아 모두 유전치부위가 유구치부위에 비해 다소 큰 경향을 보였고, 근원심 및 순(협)설측 치관 직경 모두 제2유구치에서 크기변화가 가장 적게 나타났다. 4. 좌, 우측 동명치 사이의 차이를 나타내는 비대칭성에서는 상악 근원심 크기 측정을 제외하고는 근원심 및 협설측 치관 크기 측정 모두에서 제2유구치가 제1유구치보다 보다 덜 비대칭적이었다. 5. Crown index는 상악의 경우 여아보다 남아에서 큰 반면, 하악의 경우에는 유견치를 제외하고는 여아에서 컸다. Crown module은 여아보다 남아에서 컸고, 일반적인 치아크기가 유중절치에서부터 제2유구치까지 점차 증가하였다. Crown area도 여아보다 남아에서 컸으며 하악 유중절치가 가장 적은 면적을 나타냈고, 상악 제2유구치가 가장 큰 면적을 나타냈다.

  • PDF

CS-3500 구강 내 스캐너로 채득된 디지털 인상의 신뢰도 및 정확도 평가 (Reliability and Accuracy of Digital Impression Obtained from CS-3500 Intraoral Scanner)

  • 김사학;김재홍;김종견
    • 치위생과학회지
    • /
    • 제15권5호
    • /
    • pp.673-678
    • /
    • 2015
  • 본 연구는 최신 경향의 구강 내 스캐너로 채득된 3차원 디지털 인상의 정확도와 신뢰도를 평가하기 위해 4가지 계측 지점을 통하여 분석하였다. 주 모형과 비교하였을 때, 디지털 인상이 작게 계측되는 경향을 나타내었고, 각 계측지점별로 0.06~0.12 mm 범위의 차이를 보였다. 선행연구의 결과에 의해 임상적으로 오차범위를 허용할 수 있는 것으로 나타났으며, 환자의 진단이나 치아 교정치료 계획 수립 시 사용되는 모형에는 큰 영향이 없음을 확인할 수 있었다. 실험에서는 구강 내 상황이나 해부학적 구조를 무시하고 진행하였지만, 실제 임상에서 사용 시에는 구강 내 협소한 공간, 타액 등으로 인한 치아면의 난반사 증가, 혀 등의 해부학적 구조물로 인한 작업 방해 등의 여러 가지 요인이 인상과정에 영향을 줄 수 있을 것이라 판단된다. 추후 실험에서는 가능한 구강 내 상황을 재현한 상태에서 실험을 진행하면 좀 더 임상 적용에 도움이 될 것으로 생각된다.

구순구개열의 비구순변형에서 3차원 입체 laser 스캐너를 이용한 계측분석 프로그램의 개발 (Development of Computerized Anthropometric Analysis Model in Cleft Lip Nasal Deformity Using 3D Laser Scanned Facial Cast Model)

  • 김석화;박종림;김재찬;백승학;손우길
    • Archives of Plastic Surgery
    • /
    • 제35권3호
    • /
    • pp.303-308
    • /
    • 2008
  • Purpose: The purpose of this study is to develop three-dimensional computerized anthropometry(3DCA) and to compare its reliability and accuracy 3DCA with manual anthropometry(MA) for measurement of lips and nasal deformities in unilateral cleft lips and palate(UCLP) patients. Methods: Samples were consisted of six UCLP patients whose facial plaster models were available immediately before and 3 months after the cleft lip surgery. MA of the facial plaster models was carried out using an electronic caliper. In 3DCA, three-dimensional auto-measuring program was used to digitize landmarks and to measure three-dimensional virtual facial models (3DVFM), which was generated with a laser scanner and 3D virtual modeling program. Intraclass correlation coefficients(ICC) were calculated to evaluate reliability and reproducibility of the variables in both methods, and Wilcoxon's signed rank test was done to investigate the difference in values of the same variables of facial models of each patient between two methods. Results: All ICC values were higher than 0.8, so both methods could be considered reliable. Although most variables showed statistical differences between two methods(p<0.05), differences between mean values were very small and could be considered not significant in clinical situation. Conclusion: In clinical situation, 3DCA can be an objective, reliable and accurate tool for evaluation of lips and nasal deformities in the cleft patients.