• Title/Summary/Keyword: Calibration method

Search Result 2,828, Processing Time 0.039 seconds

Comparison and Analysis of Photon Beam Data for Hospitals in Korea and Data for Quality Assurance of Treatment Planning System (국내 의료기관들의 광자 빔 데이터의 비교 분석 및 치료계획 시스템 정도관리자료)

  • Lee, Re-Na;Cho, Byung-Chul;Kang, Sei-Kwon
    • Progress in Medical Physics
    • /
    • v.17 no.3
    • /
    • pp.179-186
    • /
    • 2006
  • Purpose: Photon beam data of linear accelerators in Korea are collected, analyzed, and a simple method for checking and verifying the dose calculations in a TPS are suggested. Materials and Methods: Photon beam data such as output calibration condition, output factor, wedge factor, percent depth dose, beam profile, and beam quality were collected from 26 institutions in Korea. In order to verify the accuracy of dose calculation, ten sample planning tests were peformed. These Include square, elongated, and blocked fields, wedge fields, off-axis dose calculation, SSD variation. The planned data were compared to that of manual calculations. Results: The average and standard deviation of photon beam quality for 6, 10, and 15 MV were $0.576{\pm}0.005,\;0.632{\pm}0.004,\;and\;0.647{\pm}0.006$, respectively. The output factors of 6 MV photon beam measured at depth of dose maximum for $5{\times}5cm,\;15{\times}15cm,\;20{\times}20cm\;were\;0.944{\pm}0.006,\;1.031{\pm}0.006,\;and\;1.055{\pm}0.007$. For 10 MV photon beam, the values were $0.935{\pm}0.006,\;1.031{\pm}0.007,\;1.054{\pm}0.0005$. The collected data were not enough to calculate average, the output factors for 15MV photon beam with field size of $5{\times}5cm,\;15{\times}15cm,\;20{\times}20cm\;were\;0.941{\pm}0.008,\;1.032{\pm}0.004,\;1.049{\pm}0.014$. There was seven institutions $e{\times}ceeding$ tolerance when monitor unit values calculated from treatment planning system and manually were compared. The measured average MU values for the machines calibrated at SAD setup were 3 MU and 5 MU higher than the machines calibrated at SSD for 6 MV and 10 MV, respectively except the wedge case. When the wedges were inserted, the MU values to deliver 100 cGy to 5 cm depends on manufactures. When the same wedge angle was used, Siemens machine requires more MUs then Varian machine. Conclusion: In this study, photon beam data are collected and analyzed to provide a baseline value for chocking beam data and the accuracy of dose calculation for a treatment planning system.

  • PDF

Studies on Simultaneous Determination of Chlorophyll a and b, Pheophorbide a, and $\beta-Carotene$ in Chlorella and Spirulina Products (클로렐라 및 스피루리나제품에 함유된 엽록소 a, b, 페오포르바이드 a 및 $\beta$-카로틴의 동시분석법에 관한 연구)

  • Lee Young Ja;Kim So Hee;Kim Jin-Sook;Han Jeong A;Seo Hae Jeom;Lim Hyo Jeong;Choi Soo Young
    • Journal of Food Hygiene and Safety
    • /
    • v.20 no.3
    • /
    • pp.141-146
    • /
    • 2005
  • A simple and sensitive analysis method based on reverse phase (RP) HPLC with UV detector was developed for simultaneous determination of chlorophyll a and b, pheophorbide a and $\beta-Carotene$ in Chlorella and Spirulina products. For added concentration $(50\;\mug/ml)$ of chlorophyll a and b, pheophorbide a and $\beta-Carotene$, recoveries of those were 70.3, 71.6, 60.1 and $90.5\%$, respectively, with relative standard deviations of 2.8,6.0, 10.6 and $10.4\%$. Limit of detection and quantification had ranges of $0.1\sim1.0\;\mug/ml$ and $0.2\sim2.0\;\mug/ml$, respectively. Calibration curve was linear with correlation coefficient of 0.995 for chlorophyll a and b, pheophorbide a and $\beta-Carotene$. Results of simultaneous determination in Chlorella and Spirulina products were showed ranges of $121.g\sim543.0\;\mug/ml$ for chlorophyll a,$0.6\sim160.0\;\mug/ml$ for chlorophyll b, $19.2\sim60.3\;\mug/ml$ for pheophorbide a and $383.6\sim1713.7\;\mug/ml$ for $\beta-Carotene$, respectively. Chlorophyll b contents in Chlorella products were detected above 30 times level to those in Spirulina products. $\beta-Carotene$ contents in Spirulina products were detected 2.7 times level to those in Chlorella products.

Calculation of Bulk and Solution Electrical Conductivity of Soil Using Time Domain Reflectometry Measurements (TDR을 이용한 토양 총전기전도도 및 용액전기전도도 측정)

  • Bae, Byung-Sul;Choi, Woo-Jung;Han, Gwang-Hyun;Han, Kyung-Hwa;Yoo, Sun-Ho;Ro, Hee-Myong
    • Korean Journal of Soil Science and Fertilizer
    • /
    • v.36 no.1
    • /
    • pp.1-7
    • /
    • 2003
  • Time domain reflectometry (TDR) is a newly developed method for measuring simultaneously solute concentrations and volumetric water content of soil. Bulk electrical conductivity ($EC_a$) of soil is obtained from TDR signal using several equations proposed, and electrical conductivity of soil solution ($EC_w$) can be calculated using the linear relationship $EC_a=EC_w\theta(a\theta+b)+EC_s$ between $EC_a$ and $EC_w$ at constant soil water content. The objectives of this study were to evaluate $EC_a$ proposed by several workers and to obtain the empirical constants (a, b, and $EC_s$) for $EC_w$ of the soils from A, Bl, and B2 horizon of an agricultural field (Coarse loamy, Fluvaquentic Eutrudepts). The $EC_a$ proposed by Yanuka et al. responded most sensitively to the KCl solute concentrations. The empirical constants of a, b, and $EC_s$ for $EC_w$ were -0.249, 1.358, and 0.054 for A horizon, -2.518, 2.708, and 0.097 for Bl horizon, and 2.490, -0.250, and 0.103 for B2 horizon, respectively. Therefore, the results of this study showed that Yanuka et al. equation was most useful one in determining $EC_a$, from TDR signal for agricultural soil with low salinity and that the empirical constants for the calculation of $EC_w$, from $EC_a$ can be obtained through a simple calibration experiment.

Quantitative Analysis of Paeoniflorin and Paeonol in Peony Extracts and Quality Control Standards (모란 추출액에서 paeoniflorin과 paeonol 동시 정량 분석 및 화장품 원료의 품질관리 기준 설정)

  • Yun, Ki-Hun;Chi, Yong-Ha;Lee, Dong-Kyu;Paik, Soo-Heui
    • Journal of the Korean Applied Science and Technology
    • /
    • v.35 no.1
    • /
    • pp.235-246
    • /
    • 2018
  • Paeony has pharmacological activities such as anti-inflammatory, anti-allergic, anti-bacterial, central inhibitory, gastric secretion inhibition, and antispasmodic activities. In addition, its antioxidant activity and whitening effect being reported, thus it is being explored as raw materials for cosmetics. We compared the changes in the contents of paeoniflorin and paeonol in Peony extracts, depending on the changes of extracting solvents, temperature and time. The HPLC method was set up for simultaneous analysis, the system suitabilities were confirmed by using the calibration curves and the QC samples for each assay batch. Paeonol was detected only in roots, and paeoniflorin was higher in leaf and flower than root. Higher concentrations of both ingredients were extracted when the root was used after grinding to a suitable size, and when 30% 1,3-butylene glycol was used as the extraction solvent. Also the concentrations tended to increase at higher temperature and longer time, but the increase was gradual at over $75^{\circ}C$ and 4 hours. The ratio of root, leaf and flower was determined to be 2+2+1g/0.5kg of batch, reaching the contents criteria of paeoniflorin and paeonol. Finally, we selected as the best extraction condition when the raw materials are mixed with 2+2+1g/0.5kg and extracted with 30% 1,3-butylene glycol as an extraction solvent at $75^{\circ}C$ for 4 hours, considering both the concentrations of two components and the cost of raw materials and manufacturing process, The extraction units were scaled up to 10 kg under this condition.

Evaluation of Usefulness on In-vivo Diode Dosimetry for Measuring the Tumor Dose of Oral Cancer Patient (구강암 환자의 종양 선량 측정을 위한 In-vivo Diode Dosimetry의 유용성 평가)

  • Na Kyung-Su;Lee Je-Hee;Park Heung-Deuk
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.17 no.2
    • /
    • pp.133-140
    • /
    • 2005
  • Purpose : This test is designed to identify the validity of treatment plan by implementing real-time dosimetry by means of dose that is absorbed into PTV and OAR when preparing doses of 3D and POP plans. Materials and Methods : In treatment. error can be calculated be comparing Exp. Dose with the actual dose, which has been converted from 'the reading value obtained by placing diode detector on the area to be measured'. Same test can be repeated using Alderson-Rando phantom. Results : Errors were found: A patient(POP plan): 197.6/199=-1.2%, B patient(3D-plan): 199.9/198.7=+0.6%, C patient: 196/200=-1.5%. In addition, considering the resulted value of measuring OAR besides target-dose for C patient showed 96/200, representing does of 47%, the purpose of protection was judged to be duly accomplished. Also it was acknowledged the resulted value of -3.7% met the targeted dose within the range of ${\pm}5%$. Conclusion : Aimed for identifying the usefulness of pre-treatment dose measurement using diode detector, this test was useful to evaluate the validity of curing because it resulted in the identification of category to be protected as well as t dose. Moreover, it is thought to have great advantage in ascertaining the dose of target, dose of which is not calculated yet. Similar to L-gram before treatment, this test is thought to be very effective so that it can bring great advantages in the aspects such as validity of curing method and post-treatment plan as well.

  • PDF

Studies on Solvent Extraction and Analytical Application of Metal-dithizone Complexes(I). Separation and Determination of Trace Heavy Metals in Urine (Dithizone 금속착물의 용매추출 및 분석적 응용(제1보). 뇨중 흔적량 중금속 원소의 분리 정량)

  • Jeon, Moon-Kyo;Choi, Jong-Moon;Kim, Young-Sang
    • Analytical Science and Technology
    • /
    • v.9 no.4
    • /
    • pp.336-344
    • /
    • 1996
  • The extraction of trace cobalt, copper, nickel, cadmium, lead and zinc in urine samples of organic and alkali metal matrix into chloroform by the complex with a dithizone was studied for graphite furnace AAS determination. Various experimental conditions such as the pretreatment of urine, the pH of sample solution, and dithizone concentration in a solvent were optimized for the effective extraction, and some essential conditions were also studied for the back-extraction and digestion as well. All organic materials in 100 mL urine were destructed by the digestion with conc. $HNO_3$ 30 mL and 30% $H_2O_2$ 50 mL. Here, $H_2O_2$ was added dropwise with each 5.0 mL, serially. Analytes were extracted into 15.0 mL chloroform of 0.1% dithizone from the digested urine at pH 8.0 by shaking for 90 minutes. The pH was adjusted with a commercial buffer solution. Among analytes, cadmium, lead and zinc were back-extracted to 10.00 mL of 0.2 M $HNO_3$ from the solvent for the determination, and after the organic solvent was evaporated, others were dissolved with $HNO_3-H_2O_2$ and diluted to 10.00 mL with a deionized water. Synthetic digested urines were used to obtain optimum conditions and to plot calibration-eurves. Average recoveries of 77 to 109% for each element were obtained in sample solutions in which given amounts of analytes were added, and detection limits were Cd 0.09, Pb 0.59, Zn 0.18, Co 0.24, Cu 1.3 and Ni 1.7 ng/mL, respectively. It was concluded that this method could be applied for the determination of heavy elements in urine samples without any interferences of organic materials and major alkaline elements.

  • PDF

Operator Exposure to Indoxacarb Wettable Powder and Water Dispersible Granule during Mixing/loading and Risk Assessment (Indoxacarb의 수화제 및 입상수화제 살포액 조제 시 농작업자의 노출량 측정 및 위해성 평가)

  • Kim, Eunhye;Hwang, Yon-Jin;Kim, Suhee;Lee, Hyeri;Hong, Soonsung;Park, Kyung-Hun;Kim, Jeong-Han
    • The Korean Journal of Pesticide Science
    • /
    • v.16 no.4
    • /
    • pp.343-349
    • /
    • 2012
  • Exposure and risk assessments were conducted to evaluate the relative safety of mixing/loading work of indoxacarb between wettable powder (WP) and water dispersible granule (WG). Hand exposure was monitored using cotton gloves while inhalation exposure was measured using personal air monitor. Method validation for the exposure monitoring was established successfully through several experiments. Limit of determination and limit of quantitation were 0.25 and 1 ng, respectively. $R^2$ of calibration curve linearity was more than 0.9999 and reproducibility was 0.7-6. Recovery of indoxacarb from gloves, solid sorbent and glass fiber filter at three different levels was 81.5-108.8%. Trapping efficiency and breakthrough tests gave 981.5-108.8% of recovery. During mixing/loading procedure, hand exposure amount (75 percentile of 30 repetitions) for indoxacarb WP was 6 folds (459.8 mg/kg a.i) than that of WG (81.4 mg/kg a.i). This result indicates that WG has less drift than WP thanks to its granular type of formulation. Inhalation amount was $10^{-8}-10^{-7}%$ of spray mixture prepared and $10^{-4}-10^{-3}%$ of hand exposure. In inhalation case, no significant differences were observed between two formulations. Margin of safety was calculated for risk assessment using male Korean average body weight and acceptable operator exposure level as the important exposure factors. Mixing/loading procedures for both of the formulations were considered to be of least risk because calculated MOS values were more than 1.

Quantitative determination of inosine 5'-monophosphate dehydrogenase activity in human peripheral blood mononuclear cells by ion-pair reversed-phase high-performance liquid chromatography (이온쌍 역상 HPLC를 이용한 인체 말초혈액단핵구에서 이노신 5'-일인산 탈수소효소 활성의 정량적 측정)

  • Shin, Hye-Jin;Kwon, Soon-Ho;Park, Ji-Myeong;Kwon, Soon-Hyo;Lee, Kyoung-Ryul;Kim, Young-Jin;Lee, Sang-Hoo
    • Analytical Science and Technology
    • /
    • v.23 no.6
    • /
    • pp.531-536
    • /
    • 2010
  • A quantitative analytical method has been established for the measurement of inosine 5'-monophosphate dehydrogenase (IMPDH) activity in human peripheral blood mononuclear cells (PBMCs) by ion-pair reversed-phase high performance liquid chromatography equipped with ultraviolet detection (HPLC/UV). IMPDH is a ${\beta}$-nicotinamide adenine dinucleotide hydrate (NAD+)-dependent dehydrogenase in which the enzyme converts inosine 5'-monophosphate (IMP) into xanthosine 5'-monophosphate (XMP). Its activity was measured by quantifying a HPLC chromatogram corresponding to XMP produced during the incubation of lysed PBMCs with IMP as a substrate and $NAD^+$ as a coenzyme. XMP produced was detected at a wavelength of 260 nm. The mobile phase was composed of a mixture of 37 mM potassium dihydrogen phosphate containing 7 mM tetra-n-butylammonium hydrogen sulfate adjusted to pH 5.5 and methanol (85:15, v/v) with a flow rate of 1 mL/min. The calibration curve was linear ($r^2$=0.999999) in the range of $0.2-50.0\;{\mu}M$ and the limit of quantification (LOQ) was $0.2\;{\mu}M$. The intra- and inter-day precisions were between 0.88-1.47% and 0.85-5.24%, respectively. The intra- and inter-day accuracies were between 98.74-99.99% and 99.95-101.65%, respectively. IMPDH activity in 11 Korean healthy volunteers ranged from 18.29 to 36.60 nmol/h/mg protein (mean = $27.70{\pm}6.28\;nmol/h/mg$ protein).

Monitoring of Heavy Metals Migrated from Glassware, Ceramics, Enamelware, and Earthenware (유리제, 도자기제, 법랑 및 옹기류 재질의 식품용 기구 및 용기·포장의 중금속 이행량 모니터링)

  • Cho, Kyung Chul;Jo, Ye-Eun;Park, So-Yeon;Park, Yongchjun;Park, Se-Jong;Lee, Hye Young
    • Journal of Food Hygiene and Safety
    • /
    • v.35 no.1
    • /
    • pp.23-30
    • /
    • 2020
  • This study investigated the migration levels of lead (Pb), cadmium (Cd), and arsenic (As) from food contact articles (glassware, ceramics, enamelware, and earthenware) into a food stimulant (4% v/v, acetic acid). Migration tests were performed at 25℃ for 24 h and all analyses were performed using Inductively-Coupled Plasma Mass Spectrometry (ICP-MS). The method was validated by linearity of calibration curves, limit of detection (LOD), limit of quantification (LOQ), recovery, precision, and uncertainty. In glassware, the migration concentrations ranged from not-detected (N.D.) to 752.21 ㎍/L and N.D. to 1.99 ㎍/L for Pb and Cd, respectively. In ceramics, the migration concentrations ranged from N.D. to 1,955.86 ㎍/L, N.D. to 74.06 ㎍/L, and N.D. to 302.40 ㎍/L for Pb, Cd, and As, respectively. In enamelware, the migration concentrations ranged from N.D. to 4.48 ㎍/L, N.D. to 7.00 ㎍/L, and N.D. to 52.00 ㎍/L for Pb, Cd, and Sb, respectively. In earthenware, the migration concentrations ranged from N.D. to 13.68 ㎍/L, N.D. to 0.04 ㎍/L, and N.D. to 6.71 ㎍/L for Pb, Cd, and As, respectively. All results were below the migration limits of Korea standards and specifications for food utensils, containers, and packages.

Monitoring and Risk Assessment of Pesticide Residues on Stalk and Stem Vegetables Marketed in Incheon Metropolitan Area (인천광역시 유통 엽경채류 농산물의 잔류농약 실태조사 및 위해성 평가)

  • Park, Byung-Kyu;Jung, Seung-Hye;Kwon, Sung-Hee;Ye, Eun-Young;Lee, Han-Jung;Seo, Soon-Jae;Joo, Kwang-Sig;Heo, Myung-Je
    • Journal of Food Hygiene and Safety
    • /
    • v.35 no.4
    • /
    • pp.365-374
    • /
    • 2020
  • This study was conducted to monitor the residual pesticides on a total of 320 stalk and stem vegetables from January 2019 to December 2019 in the Incheon metropolitan area. Pesticide residues in samples were analyzed by the multi-residue method for 373 pesticides using GC-MS/MS, LC-MS/MS, GC-ECD, GC-NPD and HPLC-UVD. Risk assessment was also carried out based on the amount of stalk and stem vegetables consumed. The linearity correlation coefficient for the calibration curve was 0.9951 to 1.0000, LOD 0.002 to 0.022 mg/kg, LOQ 0.005 to 0.066 mg/kg and recovery was 82.0 to 108.0%. According to the monitoring of pesticides, 36 (11.3%) of 320 were detected with pesticide residues and 3 (0.9%) samples exceeded the maximum residual limit. The detection frequency for Chinese chives and Welsh onion was higher than that for other stalk and stem vegetables. The frequently detected pesticides were etofenprox, procymidone, fludioxonil, and pendimethalin. As a tool of risk assessment through the consumption of pesticide detectable agricultural products, the ratio of estimated daily intake (EDI) to acceptable daily intake (ADI) was calculated in the range of 0.0062-24.1423%. These results indicate that there is no particular health risk through consumption of commercial stalk and stem vegetables detected with pesticide residues.