• 제목/요약/키워드: Calibration chamber system

검색결과 78건 처리시간 0.031초

Large Calibration Chamber의 개발 (Development of Large Calibration Chamber System)

  • 정충열;김태준;김대규;이우진
    • 한국지반공학회:학술대회논문집
    • /
    • 한국지반공학회 2002년도 봄 학술발표회 논문집
    • /
    • pp.673-678
    • /
    • 2002
  • Laboratory calibration chamber tests for cone penetrometers, pressuremeters and dilatometers in cohesionless soil specimens have been conducted by numerous researchers. However, there have been only few applications to compacted or preconsolidated cohesive soils. Therefore, for the first time, Calibration Chamber System was developed in Korea University. This can be attributed to the extremely time consuming and laborious process involved in the preparation of large cohesive soil specimens in addition to other complexities involving instrumentation for pore pressure monitoring and the need for maintaing saturation by back pressure. Chamber System with similar principle as LSU Chamber System was made of more strengthen and complementary form by increasing system diameter(1.2m), carrying out 1st and 2nd consolidation process in one system for smooth and safe work, accurate Data Aquisition.

  • PDF

PSP 압력 측정 Calibration 시스템 구축 및 적용 (Application and Construction of PSP Calibration System)

  • 전영진;서형석;변영환;이재우
    • 한국추진공학회:학술대회논문집
    • /
    • 한국추진공학회 2007년도 제29회 추계학술대회논문집
    • /
    • pp.99-102
    • /
    • 2007
  • Pressure Sensitive Paint(PSP)는 압력에 반응하는 도료를 뜻한다. PSP를 이용하여 압력을 측정 하기 위해서는 paint calibration과 PSP를 도포한 모델의 풍동실험이 필요하다. PSP는 이 두 가지의 결과를 이용한 이미지의 후처리과정을 통하여 압력정보를 포함한 이미지를 얻을 수 있는 신기술이다. 본 연구에서는 PSP에 필요한 장치 및 설비들을 구성하고 PSP를 이용하여 calibration 실험을 실시하였다. 본 연구를 통해 얻어진 calibration chamber의 설계 및 제작 방법으로 진보된 calibration 시스템을 연구할 수 있는 능력을 배양하였다.

  • PDF

Calibration Chamber System을 이용한 KICT-type LPT 장비의 거동분석 (Evaluation of KICT-type Large Penetration Test using Calibration Chamber System)

  • 김영석;김영진;이우진;안신환
    • 한국지반공학회:학술대회논문집
    • /
    • 한국지반공학회 2008년도 추계 학술발표회
    • /
    • pp.1359-1364
    • /
    • 2008
  • It is well known that the standard penetration test (SPT) has been used in all over the world to get geotechnical properties of the ground. However, it is difficult to apply the SPT to the dense sand, gravel, weathered rock, etc. For the application of the SPT in these grounds, it is necessary to change in the diameter and the impact energy of the SPT. For the improvement of site investigation technology, Large Penetration Testing device (KICT-type LPT) was developed and applied to the in situ condition. The drop height and weight of the hammer in developed system were decided as 760mm and 150kg, respectively. And the developed sampler has the inner diameter of 63 mm and the length of 500 mm with the adjustment of energy ratio to the SPT of 1.5. In this study, the performance of KICT-type LPT was evaluated by using a calibration chamber system and pile driving analyzer (PDA)

  • PDF

점성토에 있어서 지반의 비등방성을 고려한 콘 관입속도에 관한 연구 (Study on Cone Penetration Rate and Anisotropy in Cohesive Soils)

  • Kim, Dae-Kyu;Lee, Woo-Jin
    • 한국지반공학회:학술대회논문집
    • /
    • 한국지반공학회 2000년도 봄 학술발표회 논문집
    • /
    • pp.559-566
    • /
    • 2000
  • 본 연구에서는 비등방성 응력조건 하에서 콘 관입속도가 콘 관입시험 결과에 미치는 영향을 연구하기 위하여 유한요소해석 및 Calibration Chamber를 이용한 Miniature Piezocone의 관입시험이 수행되었으며 그 결과를 비교 분석하였다. 비등방성을 고려하기 위하여 Anisotropic Soil Model이 유한요소해석에 이용되었으며 LSU/CALCHAS(Louisiana State University Calibration Chamber System)가 Miniature Piezocone의 관입시험에 이용되었다. 콘 관입속도의 영향이외에도 OCR 및 필터위치의 영향을 고찰하였다.

  • PDF

추력측정장치의 신뢰도 향상 방안에 관한 연구 (A Study on improving the Reliability of Thrust Measurement System)

  • 강동혁;주성민;김종규;최환석
    • 한국추진공학회:학술대회논문집
    • /
    • 한국추진공학회 2017년도 제48회 춘계학술대회논문집
    • /
    • pp.1188-1191
    • /
    • 2017
  • 추력은 연소기 개발시험 시 연소 성능을 확인하기 위한 매우 중요한 항목이다. 따라서 정확한 추력을 측정하는 것은 매우 중요하다. 정확한 추력을 측정하기 위해 추력측정장치 시스템 특성, 저항 및 선형성 등을 파악하기 위해 단계적으로 교정 시험을 수행하였다. 추력 교정식으로 산출된 추력과 이론 추력과 비교하여 약 6.9%~8.6%의 오차를 확인하였고, 연소기의 정확한 추력을 측정하기 위해서는 추진제 배관이 연결된 상태에서의 교정이 필요함을 확인하였다.

  • PDF

유동센서 보정용 캘리브레이션 제트 시스템 개발 (Development of Calibration Jet System for Calibrating a Flow Sensor)

  • 장조원;변영환
    • 한국항공운항학회지
    • /
    • 제11권1호
    • /
    • pp.41-55
    • /
    • 2003
  • A calibration jet system using separate blower is developed to calibrate a flow sensor effectively. Designed open circuit type mini calibration jet system, which has the dimension of $0.5m(W){\times}1.17m(H)$ is small compared with conventional calibration jet systems. The exit of nozzle has exchangeable contractions with a cross section area of $38.5cm^2$ , and a cross section area of $113.1cm^2$, respectively. The ranges of wind speed at exit of exchangeable nozzles are $7.5{\sim}42\;m/s$ and $1.8{\sim}16.5\;m/s$, respectively. The input power for the high pressure blower is 1.18kW. The turning vanes for corner was rolled flat plate parallel to the flow direction. The flow conditioning screen was located immediately downstream of the wide-angle diffuser. The honeycomb and two flow conditioning screens were located in the stagnation chamber. From the economical point of view and the simplicity of the calibration jet system set up and handling, it can be said that the developed calibration jet system is an effective calibration jet system. This system can also be used to calibrate the flow sensor with high resolution.

  • PDF

고선량률(HDR) 근접치료의 동위원소 Ir-192에 대한 측정방법에 관한 고찰 (A Study on Calibration Procedures for Ir-192 High Dose Rate Brachytherapy Sources)

  • 백태성;이승욱;나수경
    • 대한방사선치료학회지
    • /
    • 제19권1호
    • /
    • pp.19-26
    • /
    • 2007
  • 목 적: Ir-192 고선량율 근접치료(HDR Brachytherapy)선원에 대한 다양한 측정절차의 효율을 서로 비교할 것이며, 측정 장비의 추가 구입 없이 대안으로 새롭게 만든 PMMA (polymethylmethacrylateplastics: $C_5H_8O_2$) plate phantom에 대한임상에서의 적합성과 유용성을 알아 보았다. 대상 및 방법: 세 가지 형태(Well type chamber, Source calibration jig, PMMA plate phantom)의 측정 시스템을 이용하여 측정값을 비교하였다. Source calibration jig와 PMMA plate phantom을 사용 했을 때에는 Farmer type chamber를 이용하여 측정하였으며, 각각 5회씩 측정하여 제조업체의 측정치와 비교하였다. 또한 새로운 선원을 교환 할 때마다 제조업체로부터 선원과 함께 제공되는 제조업체의 측정치를 본 연구의 측정치와 비교하여 방사능의 정확도를 평가 하였다. 결 과: Well type chamber, Source calibration jig, PMMA plate phantom를 사용한 Ir-192 선원의 측정결과 제조업체 측정치와의 상대오차에 대한 RMS (Root Mean Square)값은 Well type chamber에서 0.6%, Source calibration jig에서 1.57%, PMMA plate phantom에서는 2.1%를 나타내었다. 또한 평균 오차에 대한 편차는 Well type chamber에서 $-0.2{\pm}0.5%$, Source calibration jig에서 $0.97{\pm}1.23%$, PMMA plate phantom에서는 $-0.89{\pm}1.87%$를 나타내었다. 결 론: 본 연구를 통해 실험한 세 가지 형태(Well type chamber, Source calibration jig, PMMA plate phantom)의 측정 시스템의 결과에서 나타난 것처럼, Well type chamber를 이용한 측정결과가 가장 우수하게 나타났다. 또한 측정 장비를 구입하지 않고 대안으로 새롭게 만든 PMMA plate phantom의 결과 권고안 ${\pm}5%$를 초과하지 않으므로 임상에서 유용하게 사용 할 수 있을 것이라 생각되어진다.

  • PDF

콘 관입시험을 이용한 연약지반 압밀특성 평가 (Determination of Consolidation Characteristics in Fine Soils Evaluated by Piezocone Tests)

  • Lim, Beyong-Seock
    • 한국지반공학회:학술대회논문집
    • /
    • 한국지반공학회 2000년도 연약지반처리위원회 학술세미나
    • /
    • pp.42-58
    • /
    • 2000
  • 본 연구의 목적은 연약지반의 압밀계수 측정에 있어 Piezocone 관입시험을 이용할 때 관입시험자체의 정확성과 시험결과들에 미치는 여러 가지 지반공학적 영향요소들을 고려하려는데 있다. 본 연구의 연구실험방법으로는, Piezocone 관입을 위한 연약모형지반 조성을 위하여 초대형 Slurry Consolidometer에 Free Stress 상태의 Slurry를 45일간 압밀시킨 후 Automatic Computer Control Calibration Chamber (LSU/CALCHAS; Louisiana State University Calibration Chamber System)에 옮긴후 다시한번 압밀시키는 Two-Stage Consolidation Method를 사용하였다 동시에 연약모형지반내에 8개의 Piezometer를 설치하여 Piezocone 관입시 유발되는 지반 내에서의 과잉간극수압의 변환을 측정하였다. 총 25개의 Piezocone 시험중 4개는 Standard 10$\textrm{cm}^2$ Piezocone이고, 나머지 21개는 Miniature Piezocone이 사용되었다. 모형지반은 여러 가지 Boundary Condition들과 Stress Condition 그리고 Stress History등을 고려하여 조성되었다. 또한 Dissipation Test직후의 압밀특성을 확인하기 위하여 0.01초당 한 개이상의 실측점을 측정할 수 있는 Digital-Oscilloscope를 이용하였다. 특히 Dissipation Test, 즉시 Piezocone의 Filter Element에 잡히지 않는 과잉간극수압의 Initial Drop 존재에 관한 기존의 추측을 실제 실험치로 확인할 수 있었다.

  • PDF

고선량률 근접조사치료용 이리듐-192 방사성동위원소의 교정방법 비교연구 (Comparison of Calibration Methods of $^{192}\textrm{Ir}$ Sources for High Dose Rate Brachytherapy)

  • 허현도;박성용;이레나;신동오;권수일;노준규;최진호
    • 한국의학물리학회지:의학물리
    • /
    • 제15권4호
    • /
    • pp.192-196
    • /
    • 2004
  • 본 연구는 국내에서 이용되고 있는 고선량률 근접치료기에 사용되는 Ir-192 선원에 대하여 Farmer type전리함과 우물형 전리함을 이용하여 선원의 세기를 측정하여 제조사에서 제공된 값과의 오차를 확인하고 두 증기간의 오차를 비교하였다. 동일한 Ir-192가 장착되어 가동 중인 6개의 병원의 고선량률 근접치료기(microSelctron, Nucletron, Netherlands)를 대상으로 선원의 모델별로 구분하여 상품화된 교정 Jig와 우물형 전리함 시스템을 이용, 선원의 세기를 측정하고 제조사에서 제공된 값과 비교하여 오차를 구하였다. 교정용 Jig를 이용한 선원 세기의 오차범위는 -2.40~+3.12%이고 우물형 전리함의 경우 오차범위는 -3.31~0.00%를 나타내었다. 측정 결과 두 장비 모두 제조사에서 제공된 값과 비교하였을 때 ${\pm}5%$의 오차를 넘지 않았으므로 임상 적용에는 문제가 없다. 외국의 사고 사례 보고에 따르면 계산 값에 의존하지 말고 새로운 선원이 교체될때 반드시 치료에 사용되기 전에 측정 도구를 이용하여 방사능의 세기를 측정하고 계산된 값과 비교하여 오차범위 내에서 일치하는지에 대한 확인 절차과정을 거치는 것이 필요하다.

  • PDF

확장한 진공용기 내부의 압력구배 측정 (Extending the Pressure Limit for Turbomolecular Pump up to 133 Pa by using Conductance-Reducer and Measuring the Pressure Differences in Vacuum Chamber)

  • 홍승수;와킬 칸;강상우;윤주영;신용현
    • 한국진공학회지
    • /
    • 제19권1호
    • /
    • pp.1-9
    • /
    • 2010
  • 진공게이지의 비교교정 방법으로 교정이 가능하고-비교교정은, 2차표준기라고 부르는 교정되어진 게이지와 교정할 다른 게이지의 지시값을 읽어 비교는 방법- 다른 진공관련 실험을 할 수 있는 기체 유량 시스템을 개발하였다. 교정시스템에의 진공용기는 터보분자펌프(TMP)에 의해서 배기하고, 후면에 스크롤펌프를 배치하여 배기시스템을 꾸몄다. 터보분자펌프의 최대허용가능 압력은 펌프의 주입구에서 0.1 Pa까지이며, 이보다 압력이 높아지면 배기속도가 감소하며 압력대 이하의 환경을 조절하기가 매우 어렵게 된다. 현재 133 Pa까지의 높은 압력을 발생시킬 수 있는 새롭게 개발된 기체유량조절시스템은 바이패스 라인에 맞도록 설계된 컨덕턴스-리듀서를 설치하여 터보분자펌프를 안전하게 운용할 수 있도록 하였다. 추가로 진공용기안에 전체압력 범위(0.1 Pa ~ 133 Pa)의 압력을 생성하며 기체 주입과 압력구배를 연구하였다. 압력의 최대 편차는 용기의 위쪽 방향에 위치한 가스 주입구에서 가까운 위치 C에서 1.6%로 나타났다.