• 제목/요약/키워드: Calibration System

검색결과 2,053건 처리시간 0.026초

Development of computer integrated system for circular error diagnosis of CMM using calibrated ring gauges

  • 박희재;김종후
    • 한국정밀공학회:학술대회논문집
    • /
    • 한국정밀공학회 1992년도 춘계학술대회 논문집
    • /
    • pp.237-241
    • /
    • 1992
  • Error calibration and frequent reverification of coordinate measuring machines(CMMs) and machine tools are currently acknowledge as essential processes in order to maintain high performance of the machines and high quality of products. This paper shows a micro computer integrated circular error calibration system, which is fast and efficient error calibration system

철도교 상시계측시스템용 검교정기 제작 및 실험 (On the Calibration of Health Monitoring System installed in the Railway Bridges)

  • 박준오;이준석;최일윤
    • 한국철도학회:학술대회논문집
    • /
    • 한국철도학회 2002년도 추계학술대회 논문집(II)
    • /
    • pp.1053-1058
    • /
    • 2002
  • Calibration of the health monitoring system is considered in this study. For this, brief introduction on the realtime monitoring system, installed in some of the Korea Highspeed Railway bridges, is made and specifications of the calibrators are outlined. Calibration method is next explained for each sensor and detailed procedures are illustrated. Calibration results will be published elsewhere and modification of the gauge factors will also be investigated in detail.

  • PDF

초음파 탐촉자의 교정 시스템 개발 (Development of Calibration System for Contact Transducer)

  • 남영현;성운학
    • 비파괴검사학회지
    • /
    • 제19권4호
    • /
    • pp.294-299
    • /
    • 1999
  • 본 논문에서는 로타(rotor)의 초음파 탐상 결과의 신뢰성을 향상시키기 위하여 수직탐촉자에 대한 교정시스템을 개발하였다. 본 시스템은 신호처리부 (오실로스코프, 스펙트럼 분석기, 송/수신기), 표준시험편 프로그램으로 구성되어 있으며, 교정을 위한 신호처리는 높은 정밀도로 빠르게 수행할 수 있도록 구성되어 있다. 개발된 시스템을 이용하여 로타 검사에 사용되고 있는 초음파 탐촉자를 교정하고 있으며, 신뢰성 있는 정밀도와 감도를 얻을 수 있었다.

  • PDF

Lynx Mobile Mapper를 이용한 레이저스캐너 기반 차량 MMS의 캘리브레이션 (Calibration of Laser scanning Mobile Mapping System using Lynx Mobile Mapper)

  • 정태준;윤홍식;황진상;김용현;이하준
    • 한국측량학회:학술대회논문집
    • /
    • 한국측량학회 2010년 춘계학술발표회 논문집
    • /
    • pp.207-208
    • /
    • 2010
  • In this paper, we carried out calibration of laser scanning MMS(Mobile Mapping System) using Lynx Mobile Mapper, a new MMS developed at Optech Incorporated. Laser scanning MMS could be defined as an integration of several subsystems. Subsystems are composed of laser scanner, gps receiver and antenna, INS(Inertial Navigation System), DMI(Distance Measurement Instrument). These are obtained 3D spatial information by direct-georeferencing technology. To obtain 3D spatial information, calibration of laser scanning MMS is required prior to operation system, it is similar to airborme lidar system. 145 checkpoints were used to accuracy estimation. The accuracy results are about 5cm(RMSE) for calibration in all directions(east, north, ellipsoidal height).

  • PDF

CTD 교정 시스템 구축 및 불확도 평가 (Establishment of CTD Calibration System and Uncertainty Estimation)

  • 이정한;황근춘;김은수;이승훈
    • Ocean and Polar Research
    • /
    • 제36권1호
    • /
    • pp.77-85
    • /
    • 2014
  • The quality control of ocean observations data is becoming a major issue as real-time observational data and information services have increased recently. Therefore, it is necessary for oceanographic instruments to calibrate. In this paper, we first introduce the CTD calibration system and traceability. Next, CTD calibration procedures and estimation of uncertainty of measurement are described. The expanded uncertainty (k = 2) of the temperature, pressure and conductivity are 0.$0.003^{\circ}C$, $6.0{\times}10^{-5}$ and 0.006 mS/cm respectively. Finally, the excellence of CTD calibration and its measurement capability has been proven by comparing the inter-calibration result of KIOST and Sea-Bird Electronics (SBE). CTD calibration residuals are less than ${\pm}0.0001^{\circ}C$, ${\pm}0.001$ MPa, ${\pm}0.0001$ S/m for SBE 3plus temperature sensor, SBE 19plus pressure sensor and SBE 4C conductivity sensor respectively.

Multi-camera System Calibration with Built-in Relative Orientation Constraints (Part 1) Theoretical Principle

  • Lari, Zahra;Habib, Ayman;Mazaheri, Mehdi;Al-Durgham, Kaleel
    • 한국측량학회지
    • /
    • 제32권3호
    • /
    • pp.191-204
    • /
    • 2014
  • In recent years, multi-camera systems have been recognized as an affordable alternative for the collection of 3D spatial data from physical surfaces. The collected data can be applied for different mapping(e.g., mobile mapping and mapping inaccessible locations)or metrology applications (e.g., industrial, biomedical, and architectural). In order to fully exploit the potential accuracy of these systems and ensure successful manipulation of the involved cameras, a careful system calibration should be performed prior to the data collection procedure. The calibration of a multi-camera system is accomplished when the individual cameras are calibrated and the geometric relationships among the different system components are defined. In this paper, a new single-step approach is introduced for the calibration of a multi-camera system (i.e., individual camera calibration and estimation of the lever-arm and boresight angles among the system components). In this approach, one of the cameras is set as the reference camera and the system mounting parameters are defined relative to that reference camera. The proposed approach is easy to implement and computationally efficient. The major advantage of this method, when compared to available multi-camera system calibration approaches, is the flexibility of being applied for either directly or indirectly geo-referenced multi-camera systems. The feasibility of the proposed approach is verified through experimental results using real data collected by a newly-developed indirectly geo-referenced multi-camera system.

기록치 오차와 유역모형의 검정(II) - 모니터링 검정방법 - (Errors in Recorded Information and Calibration of a Catchment Modelling System(II) - Monitoring Calibration Approach -)

  • Choi, Kyung Sook
    • 한국농공학회지
    • /
    • 제45권5호
    • /
    • pp.117-125
    • /
    • 2003
  • Since the recorded information used for operation of a catchment modelling system contain errors that influence the calibration of catchment modelling system control parameter values, the accurate estimation of these parameters is difficult. Despite these influences, existing traditional calibration approaches focus only on achieving the best "curve fitting" between simulated and recorded data, and not on generic evaluation of control parameter values. This paper introduces an Early Stopping Technique which is aimed at avoiding the procedure of curve-fitting through monitoring improvements in the objective function used for assessing the optimal parameter set. Application of this approach to the calibration of SWMM (Storm Water Management Model) on the Centennial Park catchment in Sydney, Australia is outlined. outlined.

신경회로망을 이용한 카메라 교정과 2차원 거리 측정에 관한 연구 (Neural Network Based Camera Calibration and 2-D Range Finding)

  • 정우태;고국원;조형석
    • 한국정밀공학회:학술대회논문집
    • /
    • 한국정밀공학회 1994년도 추계학술대회 논문집
    • /
    • pp.510-514
    • /
    • 1994
  • This paper deals with an application of neural network to camera calibration with wide angle lens and 2-D range finding. Wide angle lens has an advantage of having wide view angles for mobile environment recognition ans robot eye in hand system. But, it has severe radial distortion. Multilayer neural network is used for the calibration of the camera considering lens distortion, and is trained it by error back-propagation method. MLP can map between camera image plane and plane the made by structured light. In experiments, Calibration of camers was executed with calibration chart which was printed by using laser printer with 300 d.p.i. resolution. High distortion lens, COSMICAR 4.2mm, was used to see whether the neural network could effectively calibrate camera distortion. 2-D range of several objects well be measured with laser range finding system composed of camera, frame grabber and laser structured light. The performance of 3-D range finding system was evaluated through experiments and analysis of the results.

  • PDF

In-situ 진공게이지 교정장치 개발 (Development of an Apparatus for In-situ Vacuum Gauge Calibration)

  • 홍승수;임인태;조문재;정원호
    • 한국진공학회지
    • /
    • 제15권6호
    • /
    • pp.605-611
    • /
    • 2006
  • 정적법(constant volume method)을 이용하여 $1Pa\sim100kPa$ 영역에서 진공게이지의 직접교정 (direct calibration) 장치를 개발하였다. 이 장치는 피 교정 게이지의 이동 없이 in-situ 상태에서 비교교정(comparison calibration)도 가능하다. 이 장치가 개발됨으로서 산업체 교정기관의 생산성을 높이고 개발도상국에 국가 진공표준과 교정기술을 보급할 수 있게 되었다.

자동 보정형 디지털 제어기 설계에 관한 연구 (A Study on the Design of Digital Controllers with Automatic Calibration)

  • 나승유;박민상
    • 대한전자공학회:학술대회논문집
    • /
    • 대한전자공학회 1998년도 추계종합학술대회 논문집
    • /
    • pp.413-416
    • /
    • 1998
  • Sensitivity and calibration considerations are most important in the design and implementation of real control systems. Ideally parameter changes due to various causes should not appreciably affect the system's performances. But all the values of physical components of the plants and controllers as well as the relevant environmental conditions change in time, thus the output performance can be deteriorated during the operating span of the system. Naturally the duty of calibration or the prevention of performance deterioration due to excessive component sensitivity should be provided to the control system. In this paper, we propose a digital controller which has the capability of calibration and gain adjustment as well as the execution of control law. Specifically the problems of gain adjustment and offset calibration in the light source and CdS sensor module for position measurement in a flexible link system are considerably resolved. The parameters of measurement module are prone to change due to environmental brightness conditions resulting in poor steady state performance of the overall control system. Thus a proper method is necessary to provide correction to the changed values of gain and offset in the position measurement module. The proposed controller, whenever necessary, measures the open-loop characteristics, andthen calculates the offset and sensor gain correction values based on the prepared standard measurements. It is applied to the control of a flexible link system with the gain and offset calibration porblems in the light sensor module for position to show the applicability.

  • PDF