• 제목/요약/키워드: Calibration Factor(K-factor)

검색결과 278건 처리시간 0.028초

Determination of Microdosimetric Quantities of Several Neutron Calibration Fields at KAERI

  • Kim, B.H.;Kim, J.S.;Kim, J.L.;Chang, S.Y.;Cho, G.;McDonald, J.C.
    • Journal of Radiation Protection and Research
    • /
    • 제28권4호
    • /
    • pp.327-335
    • /
    • 2003
  • The commercially available neutron survey meter, the REM500, which uses a tissue equivalent proportional counter (TEPC) and the self-constructed TEPC were used to determine the microdosimetric quantities of several neutron calibration fields at Korea Atomic Energy Research Institute (KAERI). Microdosimetric spectra, absorbed dose, dose equivalent as well as quality factor were derived and compared with several neutron fields which were produced by using the shadow objects to make neutron scattered and being used as a kind of realistic neutron calibration fields at KAERI. The response of REM500 as a function of mean energy was evaluated with these neutron fields using the counts measured and the predetermined reference value. The response of the self-made TEPC and the REM500 was compared using one of the neutron calibration filelds of a $^{252}Cf$ source. The reference quantities of scattered neutron calibration fields were determined using a Bonner Sphere (BS). The value of frequency-mean lineal energy, dose-mean lineal energy and quality factor of two $^{252}Cf$ sources (unmoderated and $D_2O$ moderated) were determined to check the differences in the reference neutron fields between KAERI and Pacific Northwest National Laboratory (PNNL, USA) and the results were in good agreement within 1%. It means that there is no big difference in dosimetric quantifies of neutron calibration fields of two laboratories.

KSRBL Data Calibration and Note for Users

  • Bong, Su-Chan;Park, Sung-Hong;Hwangbo, Jung-Eun;Park, Young-Deuk;Lee, Dae-Young
    • 천문학회보
    • /
    • 제38권2호
    • /
    • pp.91.2-91.2
    • /
    • 2013
  • The Korean Solar Radio Burst Locator (KSRBL) is a solar radio spectrograph observing the frequency range between 0.245-18 GHz with the capability of locating the wideband gyrosynchrotron bursts. Its calibration process consists of antenna calibration, flux calibration, and demodulation. Antenna calibration is to determine the position, the width, and the peak value of the beam, flux calibration is to determine the conversion factor between the measured unit to the Solar Flux Unit (SFU), and demodulation is to determine the burst position and remove the modulation pattern. We introduce the current calibration software and some information that potential users may concern.

  • PDF

Bayesian Model Selection for Inverse Gaussian Populations with Heterogeneity

  • Kang, Sang-Gil;Kim, Dal-Ho;Lee, Woo-Dong
    • Journal of the Korean Data and Information Science Society
    • /
    • 제19권2호
    • /
    • pp.621-634
    • /
    • 2008
  • This paper addresses the problem of testing whether the means in several inverse Gaussian populations with heterogeneity are equal. The analysis of reciprocals for the equality of inverse Gaussian means needs the assumption of equal scale parameters. We propose Bayesian model selection procedures for testing equality of the inverse Gaussian means under the noninformative prior without the assumption of equal scale parameters. The noninformative prior is usually improper which yields a calibration problem that makes the Bayes factor to be defined up to a multiplicative constant. So we propose the objective Bayesian model selection procedures based on the fractional Bayes factor and the intrinsic Bayes factor under the reference prior. Simulation study and real data analysis are provided.

  • PDF

Bayesian Hypothesis Testing for Homogeneity of the Shape Parameters in the Gamma Populations

  • Kang, Sang-Gil;Kim, Dal-Ho;Lee, Woo-Dong
    • Journal of the Korean Data and Information Science Society
    • /
    • 제18권4호
    • /
    • pp.1191-1203
    • /
    • 2007
  • In this paper, we consider the hypothesis testing for the homogeneity of the shape parameters in the gamma distributions. The noninformative priors such as Jeffreys# prior or reference prior are usually improper which yields a calibration problem that makes the Bayes factor to be defined up to a multiplicative constant. So we propose the objective Bayesian testing procedure for the homogeneity of the shape parameters based on the fractional Bayes factor and the intrinsic Bayes factor under the reference prior. Simulation study and a real data example are provided.

  • PDF

Default Bayesian testing for scale parameters in the log-logistic distributions

  • Kang, Sang Gil;Kim, Dal Ho;Lee, Woo Dong
    • Journal of the Korean Data and Information Science Society
    • /
    • 제26권6호
    • /
    • pp.1501-1511
    • /
    • 2015
  • This paper deals with the problem of testing on the equality of the scale parameters in the log-logistic distributions. We propose default Bayesian testing procedures for the scale parameters under the reference priors. The reference prior is usually improper which yields a calibration problem that makes the Bayes factor to be defined up to a multiplicative constant. Therefore, we propose the default Bayesian testing procedures based on the fractional Bayes factor and the intrinsic Bayes factor under the reference priors. To justify proposed procedures, a simulation study is provided and also, an example is given.

Objective Bayesian Testing for Effect Size in Paired Study

  • Kang, Sang-Gil;Kim, Dal-Ho;Lee, Woo-Dong
    • Journal of the Korean Data and Information Science Society
    • /
    • 제19권4호
    • /
    • pp.1477-1489
    • /
    • 2008
  • This article deals with the problem of testing whether the effect size in paired study exists. We propose Bayesian hypothesis testing procedures for the effect size in paired study under the noninformative prior. The noninformative prior is usually improper which yields a calibration problem that makes the Bayes factor to be defined up to a multiplicative constant. So we propose the objective Bayesian hypothesis testing procedures based on the fractional Bayes factor and the intrinsic Bayes factor under the reference prior. Simulation study and a real data example are provided.

  • PDF

Default Bayesian one sided testing for the shape parameter in the log-logistic distribution

  • Kang, Sang Gil
    • Journal of the Korean Data and Information Science Society
    • /
    • 제26권6호
    • /
    • pp.1583-1592
    • /
    • 2015
  • This paper deals with the problem of testing on the shape parameter in the log-logistic distribution. We propose default Bayesian testing procedures for the shape parameter under the reference priors. The reference prior is usually improper which yields a calibration problem that makes the Bayes factor to be defined up to a multiplicative constant. We can solve the this problem by the intrinsic Bayes factor and the fractional Bayes factor. Therefore we propose the default Bayesian testing procedures based on the fractional Bayes factor and the intrinsic Bayes factors under the reference priors. Simulation study and an example are provided.

Evaluation of Field Calibration Test on Rail for Train Wheel Force Measurement

  • Sim, Hyoung-Bo;Yeo, Inho
    • International Journal of Railway
    • /
    • 제8권1호
    • /
    • pp.1-4
    • /
    • 2015
  • An accurate measurement of the train-track interaction forces is important for track performance evaluation. In the field calibration test as a wheel load measurement process, the calibration system creates a different boundary condition in comparison with that in the train wheel passage. This study aims to evaluate a reliability of the field calibration test in the process of wheel load measurement. Finite element models were developed to compare the deformed shapes, bending moment and shear force profiles on the rail section. The analysis results revealed that the deformed shapes and their associated bending moment profiles on the rail are significantly different in two numerical simulations of the calibration test and the train wheel load passage. However, the shear stress profile on the rail section of the strain gauge installation in the field was almost identical, which may imply that the current calibration test is sufficiently reliable.

현시선호와 진술선호 자료의 결합을 통한 조건부 가치측정법 소득조정계수의 추정 (An Empirical Test for CVM Calibration Factor through Combining Revealed and Stated Preferences Data)

  • 엄영숙
    • 자원ㆍ환경경제연구
    • /
    • 제13권3호
    • /
    • pp.337-366
    • /
    • 2004
  • 비시장재 가치평가기법 중의 하나인 조건부 가치평가법(CVM)은 응답자들이 가상적 환경질 변화에 대한 지불의사를 표시할 때 현실적 예산제약조건에 기초하지 않기 때문에 과다평가피는 경향이 있다는 비판을 받아왔다. 본 연구는 여행비용법에 기초한 레크리에이션 수요함수와 조건부 가치평가법에 기초한 지불의사함수를 효용이론의 틀 안에서 결합 추정하는 과정에서 CVM 응답과 관련된 소득조정계수(income calibration factor)를 추정함으로써 CVM의 유효성과 타당성을 분석하고자 한다. 수요함수와 지불의사함수의 결합추정모형은 최근 새만금 사업과 관련하여 논란이 되고 있는 만경강 유역의 수질개선을 사례로 분석하였다. 결함추정의 결과 중요 경제변수인 가격과 소득 그리고 수질변수들은 경제이론이 설명하는 바대로 수요함수와 지불의사 함수에 통계적으로 유효한 영향을 미쳤다. 소득조정계수 역시 통계적으로 1과 다르지 않은 것으로 나타나 실제 레크리에이션 수요행동에 비추어 가상적 수질개선에 대한 지불의사를 진술하는데 있어서, 적어도 예산과장의 측면에서 체계적인 편의는 관찰되지 않았다. 이러한 본 연구의 결과는 주의 깊게 설계된 CVM 연구가 비시장재인 환경질의 변화에 대한 소비자들의 지불의사를 도출하는데 유용한 자료를 제공할 수 있음을 실증적으로 시사하고 있다.

  • PDF

Geiger-Muller 계수관을 이용한 베타선측정에서 디텍터 보호유무에 따른 계수율 분석 (Analysis of Counting Rate according to Presence or Absence of Detector's Protector in Beta-rays Measurement using Geiger-Muller Counter)

  • 장지용;정문택;송종남;하재준;한재복
    • 한국방사선학회논문지
    • /
    • 제12권1호
    • /
    • pp.31-37
    • /
    • 2018
  • 단창형의 Geiger-Muller 계수관을 이용한 표면오염검사에서 베타선을 측정하기 위해 외부로 노출된 디텍터를 보호하는 방법으로 랩을 사용하고 있는데 이 방법이 측정계수율과 교정인자에 미치는 영향을 분석하고 방사선작업종사자에게 과도한 랩의 사용은 베타선의 측정값에 영향을 줄 수 있음을 인지시켜주고자 하였다. 실험방법은 3 KBq, 1.5 KBq, 0.3 KBq의 에너지가 다른 베타선을 이용하여 랩 두께에 따른 베타선 측정계수율과 교정인자의 변화를 비교 분석하였다. 실험 대상으로는 2012년 3월 한국인정기구 (KOLAS) 인증을 받은 교정센터에서 보유한 단창형의 Geiger-Muller 계수관을 대상으로 하였으며, Cl-36(Chlorine)과 Sr-90(Strontium)을 베타선 방사선원으로 사용하였다. 측정계수율은 랩 두께가 증가할수록 감소함을 확인 할 수 있었고 교정인자는 랩 두께가 증가할수록 증가하는 것을 알 수 있었다. 측정계수율의 감소와 교정인자의 변화는 기기지시값의 정확도를 감소시킬 수 있지만 디텍터의 오염 및 손상 또한 베타선 측정에서 중요한 영향을 주기 때문에 어느 정도 두께의 랩을 사용함이 가장 효과적인지 알아볼 필요성이 있다. 측정계수율과 교정인자의 낮은 변화율을 보여주는 두께의 랩을 사용한다면 디텍터를 보호하면서 베타선의 측정값에도 영향을 최소한으로 줄 수 있을 것으로 사료된다.