• Title/Summary/Keyword: Cadaver Test

Search Result 23, Processing Time 0.025 seconds

Effect of Education in Cadaver Practice on the Self-efficacy, Attitudes to death and Professional self -concept of Nursing students (카데바 실습교육이 간호대학생의 자기효능감, 죽음태도 및 간호전문직 자아개념에 미치는 효과)

  • Seo, Young-Sook;Jeong, Chu-yeong;Kwon, Young-Chae
    • Journal of Digital Convergence
    • /
    • v.15 no.5
    • /
    • pp.317-324
    • /
    • 2017
  • The purpose of this study was to examine the effect of cadaver practice education on self-efficacy, attitude to death, and nursing professional self-concept of nursing students. The study was designed using a non-equivalent control group pretest-posttest design, data was collected November 1 and 30, 2016. The participants were 59, 2-year nursing students (29 in the experimental group and 30 in the control group) attending 1 university located in D City. Cadaver practice education program was performed 3 sessions combined 3 hours theoretical explanation and 4 hours cadaver practice a session. The data were analyzed using descriptive analysis, ${\chi}^2$ test, and t-test with the SPSS/WIN 21.0 program. The results of the study indicate that the cadaver practice education were effective in the experimental group reported a significant increase in self-efficacy(t=2.62, p=.028), attitude to death(t=5.67, p=.000), and nursing professional self-concept(t=2.57, p=.013) compared to students in the control group in nursing students. The results of the study indicate that the cadaver practice education was effective in increasing self-efficacy, attitude to death, and nursing professional self-concept of nursing students. These results provide basic data to develop future anatomy practice curriculum.

The effect of formaldehyde on neurobehavioral performance of student during cadaver dissection (해부 실습 시 포름알데히드 노출이 학생들의 신경행동기능에 미치는 영향)

  • Sakong, Yong;Jo, Hee-Yoon;Lee, In-Gook;Lee, Kyeong-Soo;Jun, Man-Joong
    • Journal of Yeungnam Medical Science
    • /
    • v.33 no.2
    • /
    • pp.85-89
    • /
    • 2016
  • Background: Formaldehyde is used to preserve cadaver in medical schools, and students are exposed to formaldehyde during cadaver dissection classes. When humans are exposed to formaldehyde, it induces mucosal inflammation, skin inflammation, and declining of neurobehavioral function including attention and memory executive functions. The purpose of this study is to identify the effects of formaldehyde exposure on student's neurobehavioral performance during cadaver dissection classes. Methods: The level of formaldehyde was measured in a cadaver dissection class. A total of 16 students were randomly divided into two groups. One group wore respiratory protection masks, while the other group did not. Among many subtests in Korean Computerized Neurobehavioral test, backward digit span was tested on all subjects before and after the class. Results: The length of memorized digit span between the two groups was not significant; however there was a greater decrease in neurobehavioral function after formaldehyde exposure in the non-mask group than the mask group. Conclusion: Formaldehyde exposure during cadaver dissection may likely decrease neurobehavioral performance of students. Therefore, proper ventilation system and respiratory protective equipment are necessary to protect medical school students from adverse effects of formaldehyde exposure.

A Study on Development of Humeral Intramedullary Fixation Nail based on Korean Cadaver Tests (한국인 Cadaver Test에 대한 상완골 골수정 개발에 관한 연구)

  • Chon, Chang-Soo;Lee, Jae-Won;Ko, Cheol-Woong;Oh, Jong-Keon;Woo, Soo-Heon;Lee, Sung-Jae
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.28 no.8
    • /
    • pp.984-991
    • /
    • 2011
  • The aim of this study is to develop a humeral Intramedullary fixation nail (HIFN) suitable for Korean people. In this study, CT images were obtained from 72 Korean cadaveric humeral bones and 3D Korean humeral bone models were reconstructed based on the CT images to investigate anatomical characteristics. Major design parameters of HIFN were selected using the morphological measurement information of the Korean humeral bone models. Through finite element analysis and mechanical tests, the developed HIFN prototype was compared with the Polarus HIFN ($ACUMED^{(R)}$, USA), and it was found that the HIFN prototype showed similar and/or superior mechanical performance compared to the Polarus HIFN. Also, clinical validation for the HIFN prototype was carried out to check predictable troubles in surgical operations. Finally, optimal design modification was proposed to prevent the possible axillary nerve injury due to the locking screw system of the HIFN prototype.

The accuracy of linear measurements of maxillary and mandibular edentulous sites in conebeam computed tomography images with different fields of view and voxel sizes under simulated clinical conditions

  • Ganguly, Rumpa;Ramesh, Aruna;Pagni, Sarah
    • Imaging Science in Dentistry
    • /
    • v.46 no.2
    • /
    • pp.93-101
    • /
    • 2016
  • Purpose: The objective of this study was to investigate the effect of varying resolutions of cone-beam computed tomography images on the accuracy of linear measurements of edentulous areas in human cadaver heads. Intact cadaver heads were used to simulate a clinical situation. Materials and Methods: Fiduciary markers were placed in the edentulous areas of 4 intact embalmed cadaver heads. The heads were scanned with two different CBCT units using a large field of view ($13cm{\times}16cm$) and small field of view ($5cm{\times}8cm$) at varying voxel sizes (0.3 mm, 0.2 mm, and 0.16 mm). The ground truth was established with digital caliper measurements. The imaging measurements were then compared with caliper measurements to determine accuracy. Results: The Wilcoxon signed rank test revealed no statistically significant difference between the medians of the physical measurements obtained with calipers and the medians of the CBCT measurements. A comparison of accuracy among the different imaging protocols revealed no significant differences as determined by the Friedman test. The intraclass correlation coefficient was 0.961, indicating excellent reproducibility. Inter-observer variability was determined graphically with a Bland-Altman plot and by calculating the intraclass correlation coefficient. The Bland-Altman plot indicated very good reproducibility for smaller measurements but larger discrepancies with larger measurements. Conclusion: The CBCT-based linear measurements in the edentulous sites using different voxel sizes and FOVs are accurate compared with the direct caliper measurements of these sites. Higher resolution CBCT images with smaller voxel size did not result in greater accuracy of the linear measurements.

Evaluation of the Educational Efficacy of a Cadaver-based Model for Teaching a Simple Suture Technique to Medical Students (임상실습과정 의과대학생을 대상으로 카데바 모델을 이용한 단순 봉합술 교육의 효율성)

  • Do, Hyun Soo;Min, Jin Hong;Hong, Seung Woo;Han, Sang Kyoon;Kim, In Soo;Ryu, Seung;Lee, Jin Woong;Kim, Seung Whan;Yoo, In Sool
    • Journal of Trauma and Injury
    • /
    • v.19 no.2
    • /
    • pp.121-125
    • /
    • 2006
  • Purpose: There is ongoing demand to deliver better procedural training to medical students in the emergency department. Thus, we studied the efficacy of a cadaver-based training model for teaching simple suture techniques to medical students. Methods: We investigated ten fourth-year medical students, who were rounding and being trained in the Emergency Department of Chungnam National University Hospital. They were educated with slides about a simple suture technique for 30 minutes to evaluate the efficacy of the cadaver-based training model. We prospectively measured their skill by administering a test on the cadaver-based simple suture technique in 3cm sized linar wound separately to each of them. Results: A total of ten fourth-year medical students completed the investigation. The tension, the direction of suture, the degree of cleanness, the number of sutures, the adequacy of the cutting thread length, and the suturing time in the first attempt were compared with those in the second one. The second results were compared with those in the third one, and the third results were compared with those in the fourth one. All the results had statistical significance. Conclusion: These findings support the value of the cadaver-based simple suture technique training model as a medical student teaching model. The cadaver-based simple suture technique teaching model is a good way of teaching several medical skills to medical students.

The Learning Effects of Instructional Media on Anatomy Classes in a Nursing College (해부학수업에서 교수매체 적용에 따른 학습효과)

  • Sim, Jeoung-Ha
    • Journal of Korean Biological Nursing Science
    • /
    • v.11 no.1
    • /
    • pp.51-58
    • /
    • 2009
  • Purpose: It is to verify learning effect of the instructional media on anatomy classes at a nursing college and to develop an alternative instructional media instead of cadaver. Method: Four groups pretest-posttest experimental design were used. One hundred twenty students who attended an Anatomy lecture in September, 2009 were selected After attending the anatomy lecture, the subjects were divided into four group (30 for each group) conveniently. The heart anatomy knowledge level were measured by a self evaluation questionnaire and quiz before and after a different instructional media being applied for each group including making heart shape using colored clay, taking picture of a real heart, sketching the heart model with color pencil and drawing heart presented in the anatomy textbook. Data was analyzed by t-test, ANNOVA test using the SPSS/PC WIN 12 version. Result: A statistically significant differences in the level of heart anatomy knowledge acquirement was noted after four different instructional media being applied, and four different instructional media was effective to the anatomy practice education. However, no difference in statistical post test results was noted among the four groups. Conclusion: It is recommended that further comparative studies on the learning effect between human cadaver practice and different instructional media is necessary.

  • PDF

Analysis of Traumatic Brain Injury Using a Finite Element Model

  • Suh Chang-Min;Kim Sung-Ho;Oh Sang-Yeob
    • Journal of Mechanical Science and Technology
    • /
    • v.19 no.7
    • /
    • pp.1424-1431
    • /
    • 2005
  • In this study, head injury by impact force was evaluated by numerical analysis with 3-dimensional finite element (FE) model. Brain deformation by frontal head impact was analyzed to evaluate traumatic brain injury (TBI). The variations of head acceleration and intra-cranial pressure (ICP) during the impact were analyzed. Relative displacement between the skull and the brain due to head impact was investigated from this simulation. In addition, pathological severity was evaluated according to head injury criterion (HIC) from simulation with FE model. The analytic result of brain damage was accorded with that of the cadaver test performed by Nahum et al.(1977) and many medical reports. The main emphasis of this study is that our FE model was valid to simulate the traumatic brain injury by head impact and the variation of the HIC value was evaluated according to various impact conditions using the FE model.

A Permeation Characteristics Study of Water- or Oil-soluble Substances through Condition Setting for the In Vitro Skin Absorption Method (피부흡수 대체시험법의 조건설정을 통한 수용성, 지용성 물질의 투과 특성 연구)

  • Seo, Ji-Eun;Lee, Jinho;Kim, Bae-Hwan
    • Journal of Environmental Health Sciences
    • /
    • v.43 no.1
    • /
    • pp.77-86
    • /
    • 2017
  • Objectives: The purpose of this study was to compare permeation characteristics in three skin types using oil-soluble benzoic acid and water-soluble caffeine after method condition optimization based on OECD guideline 428. Methods: A Franz diffusion cell, a reliable alternative method for skin permeation, was used. One-milliliter samples were taken and immediately replaced with fresh solution in the receptor chamber at regular time intervals (1, 2, 4, 7, 10 and 24 hr). The amount of test substances was measured by LC-MS/MS. Results: The permeation rate increased dose-dependently, and the permeation orders were $KeraSkin^{TM}$ > hairless mouse full skin > human cadaver epidermis for skin types, and benzoic acid solution > caffeine solution > benzoic acid cream > caffeine cream for type of test materials. Conclusion: According to the definitions of Marzulli, benzoic acid and caffeine would be classified as 'fast' and 'moderate' compared with the permeation of other chemical species. The setting conditions and permeation characteristics performed in this study are expected to contribute to future permeation studies.

Development of $5^{th}$ percentile female finite Element Model for Crashworthiness Simulation - Part II Detail Modeling of Internal Components (충돌 안전도 해석을 위한 $5^{th}$ percentile 성인 여성 유한요소 모델 개발 - Part II 신체 부위 별 상세 모델 개발)

  • 나상진;최형연;이진희
    • Journal of Biomedical Engineering Research
    • /
    • v.25 no.4
    • /
    • pp.283-288
    • /
    • 2004
  • The finite element modeling of small female occupant for crash simulation is presented in this paper subsequently to the part I of articulated rigid body model. The limbs and internal components are additionally modeled by joining them to the articulated rigid body model for predicting the crash injuries such as bone fractures and joint dislocations. The behavioral characteristics of each limbs and internal components were validated against available cadaveric test results. Accordingly, the human model proposed in this paper could be utilized for the investigation of impact injury mechanism and further complement the lacking biofidelity of current crash dummy.