Change of electrical properties of XLPE with electirical-tree degradation (XLPE의 전기트리 열화에 따른 전기적특성의 변화)

  • Kang, D.S.;Ryoo, H.S.;Sun, J.H.;Choi, S.D.;Lee, H.J.
    • Proceedings of the KIEE Conference
    • /
    • 1999.07e
    • /
    • pp.2136-2138
    • /
    • 1999
  • In this study, we describe the change of electrical properties of XLPE with electrical-tree degradation. XLPE insulation was used as specimen which was cut off from 22.9kV XLPE insulated cable and made in a type of block. The applying voltages are 8kV, 10kV, 12kV and frequency is 60Hz Ogra needles having tip radius of 10$\mu\textrm{m}$ were inserted in blocks. PD quantity and $tan{\delta}$ and DC current were measured from inception of tree to breakdown and their characteristics were analyzed.

  • PDF

Electrical Degradation Pattern Analysis according to XLPE Cable (XLPE 케이블의 전기적 열화 패턴 분석)

  • Min, Chi-Hyun;Gwak, Dong-Sun;Chun, Hyun-Kwon;Choi, Jin-Wook;Kim, Young-Suk;Kim, Sun-Gu;Kim, Sang-Hyun
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.22 no.4
    • /
    • pp.114-120
    • /
    • 2008
  • XLPE cable is using insulator for Cross Linked Polyethylene(XLPE), because insulation Performance is superior and easy comparatively. Need systematization of accident transaction for electrical equipment accident, It is no disposal standard for defect of manufacture and second to accidents. in this paper deals with the change of XLPE cable insulation. To understand the electrical properties of XLPE insulation. Made of XLPE block sample, Penetration fracture Sample and flashover sample. Ogura needles having tip radius of $10[{\mu}m]$ were inserted into each sample. AC voltage of 1[kV/sec] increased at 60[Hz] were apple to breakdown sample and flashover sample. AC voltages of 12[kV], 17[kV] at 60[Hz] were a lied to XLPE block sample. The electrical properties of specimens were measured were measured from initiation of tree and breakdown to their characteristics were analyzed.

Effect of electrolyte on Bow-tie Water tree (Electrolyte 가 Bow-tie 형 수트리에 미치는 영향)

  • Kang, T.O.;Yang, W.Y.;Kim, K.S.;Chun, C.O.
    • Proceedings of the KIEE Conference
    • /
    • 1994.07b
    • /
    • pp.1550-1552
    • /
    • 1994
  • In order to investigate the effect of electrolyte solutions on the activities of bow-tie water trees in XLPE insulated power cable, we have tried to observe the characteristics on water treeing ( bow-tie type ) using several electrolyte solutions such as $CH_3COOH$, $MgCl_2$,HCl and NaCl solution and tap water. Bow-tie tree density in $CH_3COOH$ and $MgCl_2$ solution was higher than in any other solution, and the growth of tree was stimulated in NaCl and $CH_3COOH$ solution, and diffusion of bow-tie trees into insulation in $MgCl_2$, HCl and NaCl solutions was faster than in $CH_3COOH$ solution and water. Also, although the increase of applied voltage caused bow-tie tree density to be high, it didn't affect the growth of tree maximum length noticeably.

  • PDF

Aging Diagnosis and Characteristic Analysis of Distribution ,Power Cables I to Prepare Optimal Replacement Criterion (지중 배전케이블의 최적 교체기준 수립을 위한 열화진단 및 특성분석)

  • 김주용;송일근;정익중;한명관;심유종;문재덕
    • The Transactions of the Korean Institute of Electrical Engineers C
    • /
    • v.53 no.5
    • /
    • pp.258-263
    • /
    • 2004
  • The purpose of this experiment is to modify diagnosis criterion of isothermal relaxation current(IRC) measurement equipment which is using for distribution cable diagnosis. We're using this system for several years in the field instead of DC leakage current measurement and lots of cables were replaced. But we have to investigate on the reliability of this equipment for our cables because we didn't carried out condition assessment of extracted cables after field diagnosis by this equipment. It is important thing for cable maintenance. If the replacement criterion is improper we can not prevent failures or will waste budget on account of replacement of the sound cables. In this paper we selected field installed cables and injected silicone fluid to the cables for insulation rehabilitation. In order to prove reliability of the diagnosis equipment we compared diagnosis results and AC breakdown strength according to operating time after silicone treatment. This is the results of the field test for 1 year.

Modeling of Access Networks and Applications for the Economics of New Access Network Technology (신규 가입자망 기술의 경제성 평가를 위한 망 구조모형과 그 응용)

  • 류태규;이정동;김태유
    • Journal of Korea Technology Innovation Society
    • /
    • v.4 no.2
    • /
    • pp.157-171
    • /
    • 2001
  • This paper discusses the economics of local loop architecture focusing on existing technologies, ADSL, HFC, and new one, PLC, and suggests a new modeling approach of access network system and the numerical equations. To modelize access network system and drive the numerical equations, we consider the double star and the tree & branch architecture and made block diagram of each access system. In addition, we introduce the density of subscriber as a variable and the equation of seeking the optimal number of cell in a service area. The economics of local loop architecture is analyzed in two ways, i.e. with and without consideration of the cost of cable and infrastructure. From the numerical analysis, we find that in case of not including the cost of cable and infrastructure, there is no much difference in the cost per one subscriber, while, in case of including it, there is remarkable difference among technologies. Therefore we conclude that the economics of local loop architecture is depend on the density of subscriber and existing network infrastructures.

  • PDF

A Study on the Tree Growth by Interface Type of XLPE (XLPE의 계면형태에 따른 트리성장에 관한 연구)

  • 김철운;김영민;김태성
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 1997.04a
    • /
    • pp.111-115
    • /
    • 1997
  • There exists a interface among the different kinds of materials in the solid insulating ones, which effects on the insulating capability heavily. The insulating construction has been developed for each usages and take themselves into several sorts. The conjunction between CV cables have the electrical weakness of solidity and solid interface, so they were focused at the long distance-line. To this background, it is very important to get the information on the interface influencing on the insulating capability of cable and to observe its procedure. In this paper, the interface was made artificially to research the effect owing to the toughness of interface, which results in the aging and treeing proceeding was observed. The polyethylen, as is generally using for the cable, was taken in this research.

  • PDF

Thermal and Electrical Breakdown Phenomena in Electrical Insulator of Power Cable (전력케이블용 전기절연재료의 열적, 전기적 파괴현상)

  • Cho, Young-Shin;Shim, Mi-Ja;Kim, Sang-Wook
    • Proceedings of the KIEE Conference
    • /
    • 1997.11a
    • /
    • pp.187-189
    • /
    • 1997
  • Thermal and electrical breakdown phenomena in XLPE insulator of power cable were investigated. At high temperature the polymeric insulator was thermally deteriorated. Under the magnified high electric field, electrical tree was initiated at the sharp tip of needle electrode which was inserted to simulate the defects and impurities such as void, crack, metallic particles, dusts, and so on.

  • PDF

The Characteristics of PD Patterns due to the Aging at the Interface between Solid Insulators (고체절연체 계면에서 부분방전 패턴의 열화에 따른 변화특성)

  • Lee, Woo-Young;Sun, Jong-Ho
    • Proceedings of the KIEE Conference
    • /
    • 1998.07e
    • /
    • pp.1725-1727
    • /
    • 1998
  • In this paper the patterns of partial discharges(PD) occurred from some defects at the interface of cable joints as the function of the phase of the applied voltage were investigated in order to discern the kind of a defect. The results obtained in this study show that it is possible to distinguish the PD patterns between the void discharges and the treeing or tracking discharges which were occured at the cable joint interface. While the state of defect transfers from a void discharge into a tree or tracking discharge with a aging time, the skewness for both half of the applied voltage cycle is observed to go to the negative value.

  • PDF

Life Expectancy for Power Cable Insulation(XLPE) Using Statistical Method (통계적 기법을 이용한 전력 케이블 절연층(XLPE)의 수명 예측)

  • 이승엽;조대희;이인호;박완기
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 1999.05a
    • /
    • pp.57-61
    • /
    • 1999
  • Electrical stress makes insulating materials aged finally resulting in the dielectric failure. It becomes more and more important to recognize the degree of aging and the life time of the insulating materials since it is directly concerned with the reliability of the insulation system. In this paper, the life time of the Cross-linked Polyethylene(XLPE), the insulation layer in the 154kV-grade power cable, is expected and calculated using statistical and mathematical methods. The simulated results are compared with experimental ones and the life exponent of the material is obtained.

  • PDF

Assessment of material analysis for TR CNCE-W (수트리억제 충실 전력 케이블(TR CNCE-W)의 재료에 대한 평가 기술)

  • Soh, Jin-Joong;Shim, Dae-Sub;Kim, Ku-Sub
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2007.11a
    • /
    • pp.221-222
    • /
    • 2007
  • The test method on materials of electrical power cable are used in accordance with 18 specifications of IEC, ICEA, KS and KEPCO Spec. The validation of test methods were checked and established by solving the problems occurred during the test. These tests are tensile strength, hot creep, shrink back, environmental stress cracking, flammability, oxygen index, absorption coefficient, differential scanning calorimetry, amount of ion in semiconductor, void, amber, contaminant and water tree etc. The performance test of power cable made by A, B, C, D company were evaluated and compared.