• 제목/요약/키워드: Cable Anchor System

검색결과 21건 처리시간 0.023초

해상 사장교의 Pipe형 케이블 정착구에 관한 구조해석 (Structural Analysis of a Cable Anchor System for a Cable-Stayed Bridge over the Sea)

  • 공병승;홍남식
    • 한국해양공학회지
    • /
    • 제19권5호
    • /
    • pp.34-42
    • /
    • 2005
  • The cable connection zone of the cable-stayed bridge transfers deal-load, live-load, and second-load to the cables on the structural joint zone of the cables and the main girders are the most critical parts in which big cable tensile forces are generated by those loads. Therefore, it is necessary to thoroughly check the main girder, structurally to secure the required stability. Because of the heavy tensile force of cables linked in the connection zone of the cable-stayed bridge, locally concentrated stress, as well as the dispersion of stress, occurs in the structurally contacted point of cable and main girder thus, we need to make a thorough investigation through a detailed structural analysis. Directly delivering the tensile force to the connection zone of the cable, the consequently big effect in the tensile force fluctuation caused by the live-load will make it necessary to review the fatigue strength. As the connection zone of the cable is designed to resist the tensile force of the cable, which is applied to a connecting section as a concentrated force, thick plates are used. These plates are frequently made of welded structure, thus, the investigation of the welding workability is inevitable.

사장교 가이드 파이프 앵커 형식에서의 정착강관 설계절차 (Design Process of Fixing Pipe in Guide Pipe-Anchor System for Cable-Stayed Bridge)

  • 홍성남;박선규;박병건
    • 한국구조물진단유지관리공학회 논문집
    • /
    • 제15권4호
    • /
    • pp.212-220
    • /
    • 2011
  • 최근 들어 인천대교 등 다수의 사장교가 공용 또는 시공 중에 있으며 이러한 시점에서 국내 사장교의 기술력을 살펴본다면 시공기술은 눈에 띄게 발전하였지만 설계기술은 아직 국외 의존도가 매우 높은 실정이다. 사장교 핵심설계요소들 중 케이블 정착구조는 강력한 케이블 장력의 작용으로 국부적인 응력집중현상이 발생하므로 안전성 확보를 위해서는 반드시 국부상세해석에 의한 설계가 요구된다. 하지만 명확한 설계기준이나 이론적 설계 없이 유한요소해석에만 의존하여 설계하는 실정이며 정착구조의 이론적 기본메커니즘을 이해하지 못한 채 유한요소해석 결과에만 의존, 엔지니어의 판단력이 흐려지는 부작용을 가져오고 있다. 이에 따라 본 연구에서는 케이블 정착구조 가이드 파이프앵커 형식 중 정착강관의 기존 이론적인 설계절차를 나타내고 추가적으로 고려해야 할 사항들을 국내외 설계기준에 따라 정리하고 보완 설계절차를 제시하였다.

철도용 사장교의 케이블 정착구조에 관한 연구 (A Study on Cable Anchor System in Cable-Stayed Railway Bridge)

  • 공병승
    • 한국철도학회:학술대회논문집
    • /
    • 한국철도학회 2005년도 추계학술대회 논문집
    • /
    • pp.1229-1234
    • /
    • 2005
  • Since the 20th century, the business of railway was invaded by the invention of airplanes and vehicles in the field of the transportation of passenger and commercial products, however, in the 21st century, the fervent development of a high speed railway made possible the huge capacity of transporting passengers and commercial freight, so the railway industry is facing a new era of railway revolution. The 200 years old railway tradition includes the history of railway bridges built in areas of river, valley and metropolitan region and in that, the number of constructions of railway bridges that is composed of cable-stayed bridges is increasing as one of the most optimal bridges considering the quality of materials and the span of continuous-welded long rail. Thanks to the minimized effects of the fixed load on the stiffening girder section by delivering the fixed load which is applied to the pylon with the composition of elastic supporting points by using cables and the effective structural system that can throughly resist extra loads in addition to fixed load, the long-extended span of a bridge becomes possible. In this structural system, the load that is applied to the stiffening girder section forms a now pattern and in the process of these load delivery, there will be a necessity to examine the concentration of stress occurred in the cable-anchor system of the cable.

  • PDF

철도용 사장교의 케이블 정착구조에 관한 형식별 FEM해석 연구 (A Study on Stress Analysis of Cable Anchor System in Cable-Stayed Railway Bridge)

  • 박지호;공병승
    • 한국철도학회:학술대회논문집
    • /
    • 한국철도학회 2006년도 추계학술대회 논문집
    • /
    • pp.552-557
    • /
    • 2006
  • Since the 20th century, the business of railway was invaded by the invention of airplanes and vehicles in the field of the transportation of passenger and commercial products, however, in the 21st century, the fervent development of a high-speed railway made possible the huge capacity of transporting passengers and commercial freight, so the railway industry is facing a new era of railway revolution. The 200 years old railway tradition includes the history of railway bridges built in areas of river, valley and metropolitan region and in that, the number of constructions of railway bridges that is composed of cable-stayed bridges is increasing as one of the most optimal bridges considering the quality of materials and the span of continuous-welded long rail. Thanks to the minimized effects of the fixed load on the stiffening girder section by delivering the fixed load which is applied to the pylon with the composition of elastic supporting-points by using cables and the effective structural system that can throughly resist extra loads in addition to fixed load, the long-extended span of a bridge becomes possible. In this structural system, the load that is applied to the stiffening girder section forms a flow pattern and in the process of these load delivery, there will be a necessity to examine the concentration of stress occurred in the cable-anchor system of the cable.

  • PDF

설계 개선을 통한 선박의 계류 시스템 최적화 사례 소개 (Introduction of Optimized Design of Anchoring System through Design Modification of Pocket and Chain Compressor)

  • 이재훈
    • 대한조선학회 특별논문집
    • /
    • 대한조선학회 2011년도 특별논문집
    • /
    • pp.55-62
    • /
    • 2011
  • Although the performance of the commercial vessel has been dramatically improved through innovations, there has been no big changes on the traditional anchoring method of commercial vessels, both on design and operation until now. In this paper, two cases of design modifications were introduced for optimized design of pocket type anchor handling, which resulted in improved performance of the vessel's anchoring. From the first time fully balanced type anchors were applied on vessels in Korean shipyard, main design problem on this application was that the anchor doesn't normally slide into the pocket when the anchor fluke is not in line with pocket, as the anchor freely rotates by the swivel on forerunner. In order to prevent the problem, swivel has been deleted on the forerunner to prevent anchor rotation until now, but this solution caused problems such as twist lock of anchor chain, restriction of windlass direction, etc. On this paper, one of the solution is introduced to overcome the design problem by tilting the hawse pipe to some extent, which makes anchor turned at the time anchor ring touches the pocket skirt and that it properly slides into the pocket. Secondly, one of the solution is introduced to overcome misalignment problem between anchor chain cable and roller of chain compressor, which has been frequently occurred, by modification of roller design.

  • PDF

Development of umbrella anchor approach in terms of the requirements of field application

  • Evirgen, Burak;Tuncan, Ahmet;Tuncan, Mustafa
    • Geomechanics and Engineering
    • /
    • 제18권3호
    • /
    • pp.277-289
    • /
    • 2019
  • In this study, an innovative anchoring approach has been developed dealing with all relevant aspects in consideration of previous works. An ultimate pulling force calculation of anchor is presented from a geotechnical point of view. The proposed umbrella anchor focuses not only on the friction resistance capacity, but also on the axial capacity of the composite end structure and the friction capacity occurring around the wedge. Even though the theoretical background is proposed, in-situ application requires high-level mechanical design. Hence, the required parts have been carefully improved and are composed of anchor body, anchor cap, connection brackets, cutter vanes, open-close ring, support elements and grouting system. Besides, stretcher element made of aramid fabric, interior grouting system, guide tube and cable-locking apparatus are the unique parts of this design. The production and placement steps of real sized anchors are explained in detail. Experimental results of 52 pullout tests on the weak dry soils and 12 in-situ tests inside natural soil indicate that the proposed approach is conservative and its peak pullout value is directly limited by a maximum strength of anchored soil layer if other failure possibilities are eliminated. Umbrella anchor is an alternative to conventional anchor applications used in all types of soils. It not only provides time and workmanship benefits, but also a high level of economic gain and safe design.

Structural health rating (SHR)-oriented 3D multi-scale finite element modeling and analysis of Stonecutters Bridge

  • Li, X.F.;Ni, Y.Q.;Wong, K.Y.;Chan, K.W.Y.
    • Smart Structures and Systems
    • /
    • 제15권1호
    • /
    • pp.99-117
    • /
    • 2015
  • The Stonecutters Bridge (SCB) in Hong Kong is the third-longest cable-stayed bridge in the world with a main span stretching 1,018 m between two 298 m high single-leg tapering composite towers. A Wind and Structural Health Monitoring System (WASHMS) is being implemented on SCB by the Highways Department of The Hong Kong SAR Government, and the SCB-WASHMS is composed of more than 1,300 sensors in 15 types. In order to establish a linkage between structural health monitoring and maintenance management, a Structural Health Rating System (SHRS) with relevant rating tools and indices is devised. On the basis of a 3D space frame finite element model (FEM) of SCB and model updating, this paper presents the development of an SHR-oriented 3D multi-scale FEM for the purpose of load-resistance analysis and damage evaluation in structural element level, including modeling, refinement and validation of the multi-scale FEM. The refined 3D structural segments at deck and towers are established in critical segment positions corresponding to maximum cable forces. The components in the critical segment region are modeled as a full 3D FEM and fitted into the 3D space frame FEM. The boundary conditions between beam and shell elements are performed conforming to equivalent stiffness, effective mass and compatibility of deformation. The 3D multi-scale FEM is verified by the in-situ measured dynamic characteristics and static response. A good agreement between the FEM and measurement results indicates that the 3D multi-scale FEM is precise and efficient for WASHMS and SHRS of SCB. In addition, stress distribution and concentration of the critical segments in the 3D multi-scale FEM under temperature loads, static wind loads and equivalent seismic loads are investigated. Stress concentration elements under equivalent seismic loads exist in the anchor zone in steel/concrete beam and the anchor plate edge in steel anchor box of the towers.

시공성 및 경제성을 고려한 사장교 부반력 제어 연구 : 베트남 밤콩 사장교 사례 (A Study on Controlling the Negative Reaction of Cable Stayed Bridge Considering Constructability and Economy : Vam Cong Cable Stayed Bridge in Vietnam)

  • 이용진;노병철;김창교;배상운
    • 한국구조물진단유지관리공학회 논문집
    • /
    • 제18권5호
    • /
    • pp.87-95
    • /
    • 2014
  • 사장교는 다수의 케이블에 의해 지지되어 복잡한 거동을 하는 구조체이며, 측경간 케이블에 의해 단부교각에서 부반력이 발생한다. 이를 해결하기 위해 적절한 측경간비를 설정해야 하고 앵커교각의 부반력 대책을 강구해야 한다. 부반력 제어 대책으로는 중간교각, 카운터 웨이트 등을 설치하는 방안이 있으며 이에 따라 사장교의 구조계가 결정된다. 밤콩교량은 타당성 검토 단계에서 5경간 사장교로 계획되었다. 하지만 시공성 및 경제성 등의 문제로 실시설계 단계에서 3경간 사장교로 변경되었다. 시공성을 확보하기 위하여 중간교각을 배제하였고, 이에 따른 부반력을 제어하기 위해 측경간비를 증가시켰다. 그 결과, 원안 설계에 비하여 시공성, 구조적 안전성, 효율성을 확보할 수 있었다.

엑스트라도조교 사재 정착구 시스템에 대한 실험적 연구 (Experimental Study of Extradosed Bridge Anchor System)

  • 김기동;박원태
    • 한국안전학회지
    • /
    • 제25권6호
    • /
    • pp.146-154
    • /
    • 2010
  • In this study the experimental results of fatigue specimen for the Strand Stay Cable Assembly of Extadosed bridges is investigated. The fatigue test and tensile experiment is conducted to 6 kinds of specimens. Test specimen OVM250-31 Strand Cable System manufactured by china OVM B-Machinery Co., Ltd, and OVM250-42 Parallel Strand Stay Cable Assembly manufactured by china OVM B-Machinery Co., Ltd, are passed for fatigue test and rupture tensile test. But Test specimen OVM250-42 Parallel Strand Stay Cable Assembly manufactured by korean A-Machinery Co., Ltd, is not passed for fatigue test conducted according to the "Recommendation for Stay Cable Design. The test result are compared to the fatigue criteria of PHI 2001 for cyclic load, and it is concluded that the current korean design code will be needed for representing the fatigue load in Hot Dip Galvanized Strand Stay Cable. It is verified that the new korean specification and quality criteria of Strand Stay Cable and exact experimental applied process will be needed.

철도용 사장교의 주탑 케이블 정착부에 관한 연구 (A Study on Pylon Cable Anchor System in Cable-Stayed Railway Bridge)

  • 한성관;공병승
    • 한국철도학회:학술대회논문집
    • /
    • 한국철도학회 2006년도 추계학술대회 논문집
    • /
    • pp.565-580
    • /
    • 2006
  • Set in constant increase and period current of lively technical development of railroad use and construction of cable stayed bridge railway bridge, one of bridge form of most suitable that think side police officer and the material enemy of bridge that use long rail, is increasing laying stress on the foreign countries. Main tower fixing department of this cable stayed bridge is consisted of main tower flange that support bearing plate, bay ring plate bearing plate, support end rib and diaphragm etc, as stress transmission mechanic that tensility of cable socket into normal force of main tower, and is used this time. These structural elements is very complex the structure and direction of load delivered from socket specially calbe particularly be different, and need FEM analysis that use Thick Shell element for suitable arrangement of mutual stress flowing grasping and absence that follow hereupon because all of the each support plate angle that suport this differ.

  • PDF