Browse > Article

Experimental Study of Extradosed Bridge Anchor System  

Kim, Gi-Dong (Department of Construction and Environmental Engineering, Kongju National University)
Park, Weon-Tae (Department of Construction and Environmental Engineering, Kongju National University)
Publication Information
Journal of the Korean Society of Safety / v.25, no.6, 2010 , pp. 146-154 More about this Journal
Abstract
In this study the experimental results of fatigue specimen for the Strand Stay Cable Assembly of Extadosed bridges is investigated. The fatigue test and tensile experiment is conducted to 6 kinds of specimens. Test specimen OVM250-31 Strand Cable System manufactured by china OVM B-Machinery Co., Ltd, and OVM250-42 Parallel Strand Stay Cable Assembly manufactured by china OVM B-Machinery Co., Ltd, are passed for fatigue test and rupture tensile test. But Test specimen OVM250-42 Parallel Strand Stay Cable Assembly manufactured by korean A-Machinery Co., Ltd, is not passed for fatigue test conducted according to the "Recommendation for Stay Cable Design. The test result are compared to the fatigue criteria of PHI 2001 for cyclic load, and it is concluded that the current korean design code will be needed for representing the fatigue load in Hot Dip Galvanized Strand Stay Cable. It is verified that the new korean specification and quality criteria of Strand Stay Cable and exact experimental applied process will be needed.
Keywords
extradosed bridge; the hot dip galvanized strand stay cable assembly;
Citations & Related Records
Times Cited By KSCI : 3  (Citation Analysis)
연도 인용수 순위
1 Magdi A. Khalifa, Osama, A, Hodhod, and Mohammed A. Zaki, "Analysis and design methodology for an FRP cable-stayed pedestrian bridge", Composite : part B, 27B, pp. 307-317, 1996.
2 Zhang Jun, Kang, "Anti sliding Test of Cable at Pylon Saddle", Civil Engineering Testing Center of Guangxi Uni. Of Technology, pp. 1-20, 2004.
3 Fatigue and tensile tests according to PTI 2001, Test Report No.441'745, OVM MACHINERY CO. LTD., EMPA, 2007.
4 Fatigue and tensile tests based on PTI 2001, Test Report No.446'201, OVM MACHINERY CO. LTD., EMPA, 2007.
5 Fatigue and tensile tests based on PTI 2001, Test Report No.446'201, OVM MACHINERY CO. LTD., EMPA, 2007.
6 Fatigue and tensile tests based on PTI 2001, Test Report No.447'063, OVM MACHINERY CO. LTD., EMPA, 2007.
7 Fatigue and tensile tests based on PTI 2001, Test Report No.447'388, OVM MACHINERY CO. LTD., EMPA, 2007.
8 Fatigue and tensile tests based on PTI 2001, Test Report No.448'079, OVM MACHINERY CO. LTD., EMPA, 2007.
9 송용선, 이병식, 박원태, 김형주 "화재에 의한 사장교 케이블의 유한요소 해석", 한국산학기술학회논문집, 제9권, 제1호, pp.136-142, 2008.   과학기술학회마을
10 류봉조, 송용선, 박원태, "화재의 대한 Extra-doed교 케이블의 안정성평가", 한국방재학회논문집, 제8권, 제5호, pp. 23-33, 2008.   과학기술학회마을
11 유웅석, 김동근, 조정식, "금가대교(7경간 연속 Extrdosed교)의 설계, 대한토목학회지, 제50권, 제11호, pp. 28-39, 2002.
12 길태수, 김성일, 김연태, "3경간 연속 Extadosed PSC 철도교의 동적거동에 관한 연구", 한국철도학회 논문집, 제9권, 제2호, pp. 137-144, 2006.   과학기술학회마을