• 제목/요약/키워드: Cabinet

검색결과 362건 처리시간 0.026초

Module level EMC verification method for replacement items in nuclear power plant

  • Hee-Taek Lim;Moon-Gi Min;Hyun-Ki Kim;Gwang-Hyun Lee;Chae-Hyun Yang
    • Nuclear Engineering and Technology
    • /
    • 제55권7호
    • /
    • pp.2407-2418
    • /
    • 2023
  • Internal replaceable electronic module substitutions can impact EMC (ElectroMagnetic Compatibility) qualification testing and results if EMC testing is conducted at the cabinet level. The impact of component substitutions on EMC qualification results therefore should be evaluated. If a qualitative evaluation is not adequate to ensure that the modified product will not impact the cabinet level EMC qualification results, a new qualification testing should be conducted. Component level retesting should be conducted under electromagnetically equivalent conditions with the cabinet level test. This paper analyzes the propagation of conducted susceptibility test waveforms in a representative cabinet and evaluates the impact of component substitutions on cabinet level EMC qualification results according to the location of the replacement items. A guideline for a qualitative evaluation of the impact of component substitutions is described based on the propagation of the conducted susceptibility test waveforms. A module level test method is also described based on an analysis of the shielding effectiveness of the cabinet.

칼리가리 박사의 밀실과 해체주의 건축의 표현주의 특성 비교 (Comparison of "The Cabinet of Dr. Caligari" and Deconstructive Architecture in the Expressionist Characteristics)

  • 최효식
    • 한국실내디자인학회논문집
    • /
    • 제25권1호
    • /
    • pp.35-46
    • /
    • 2016
  • The purpose of this study was to identify the characteristics of expressionism in the space of deconstructive architecture by comparing the spaces of "The Cabinet of Dr. Caligari" video with the expressionist characteristics of film narrative structure and expressionist architecture and making an expansion based on the results. The findings were as follows: first, the "The Cabinet of Dr. Caligari" is divided into two set spaces: one has the perspective representation distorted in the viewpoint of a mad person applied to it, and the other reflects the viewpoint of a normal person from medieval paintings with no perspective. Second, the expressionist buildings did not reflect the expressionist characteristics in the interior spaces as fully as in the exterior ones. Third, the incomplete combination of Signifiant and $Signifi{\acute{e}}$, which were the theoretical basis of deconstructive architecture, showed a tendency of binary opposition like the double narrative structure of "The Cabinet of Dr. Caligari." Fourth, deconstructive architecture seems to embody the exterior form and interior space of "The Cabinet of Dr. Caligari" and its set spaces in the phenomenal aspect but exhibits its limitations with the realization of dynamics, one of the characteristics of expressionism. Finally, the Seattle Public Library presents the best embodiment of expressionist characteristics found in the set spaces of "The Cabinet of Dr. Caligari" while seeking after the combination of horizontal and vertical paths of action through the spiral ramps and inclined slabs.

Grouping effect on the seismic response of cabinet facility considering primary-secondary structure interaction

  • Salman, Kashif;Tran, Thanh-Tuan;Kim, Dookie
    • Nuclear Engineering and Technology
    • /
    • 제52권6호
    • /
    • pp.1318-1326
    • /
    • 2020
  • Structural modification in the electrical cabinet is investigated by a proposed procedure that comprises of an experimental, analytical and numerical solution. This research emphasizes the linear dynamic analysis of the cabinet that is studied under the seismic excitation to demonstrate the real behavior of the cabinets in NPP. To this end, an actual electric cabinet is experimentally tested using an impact hammer test which reveals the fundamental parameters of the cabinet. The Frequency-domain decomposition (FDD) method is used to extract the dynamic properties of the cabinet from the experiment which is then used for numerical modeling. To validate the dynamic properties of the cabinet an analytical solution is suggested. The calibrated model is analyzed under the floor response obtained from the Connecticut nuclear power plant structure excited by Tabas 1978 (Mw 7.4) earthquake. Eventually, the grouping effect of the cabinets is proposed which represents the influence on the dynamic modification. This grouping of the cabinets is described more sophisticatedly by the theoretical understating, which results in a significant change in the seismic response. Considering the grouping effects will be helpful in the assessment of the real seismic behavior, design, and performance of cabinets.

Seismic capacity evaluation of fire-damaged cabinet facility in a nuclear power plant

  • Nahar, Tahmina Tasnim;Rahman, Md Motiur;Kim, Dookie
    • Nuclear Engineering and Technology
    • /
    • 제53권4호
    • /
    • pp.1331-1344
    • /
    • 2021
  • This study is to evaluate the seismic capacity of the fire-damaged cabinet facility in a nuclear power plant (NPP). A prototype of an electrical cabinet is modeled using OpenSees for the numerical simulation. To capture the nonlinear behavior of the cabinet, the constitutive law of the material model under the fire environment is considered. The experimental record from the impact hammer test is extracted trough the frequency-domain decomposition (FDD) method, which is used to verify the effectiveness of the numerical model through modal assurance criteria (MAC). Assuming different temperatures, the nonlinear time history analysis is conducted using a set of fifty earthquakes and the seismic outputs are investigated by the fragility analysis. To get a threshold of intensity measure, the Monte Carlo Simulation (MCS) is adopted for uncertainty reduction purposes. Finally, a capacity estimation model has been proposed through the investigation, which will be helpful for the engineer or NPP operator to evaluate the fire-damaged cabinet strength under seismic excitation. This capacity model is presented in terms of the High Confidence of Low Probability of Failure (HCLPF) point. The results are validated by the proper judgment and can be used to analyze the influences of fire on the electrical cabinet.

Seismic evaluation of different types of electrical cabinets in nuclear power plants considering coupling effects: Experimental and numerical study

  • Md Kamrul Hasan Ikbal;Dong Van Nguyen;Seokchul Kim;Dookie Kim
    • Nuclear Engineering and Technology
    • /
    • 제55권9호
    • /
    • pp.3472-3484
    • /
    • 2023
  • The objective of this research is to assess the seismic performance of different types of electrical cabinets in nuclear power plants. The cabinets under investigation are: (a) Case 1: a short single cabinet; (b) Case 2: a tall single cabinet; (c) Case 3: separated cabinets; and (d) Case 4: a combined cabinet with coupling effects. To accurately capture the real behavior of the cabinet, three-dimensional finite element models are developed using ANSYS with connection non-linearity. Frequency domain decomposition (FDD) is used to determine the dynamic properties of the cabinets from shaking table testing data, and these results are utilized to validate the numerical model. The close match between the experimental and numerical results obtained from the modal analysis demonstrates the accuracy of the numerical model. Subsequently, transient structural analysis is performed on the validated models to explore seismic performance. The results show that the acceleration response of the combined cabinet is lower than the single cabinet and the separated cabinet. This observation suggests that top anchors used to combine two different types of cabinets play a crucial role in assessing the efficiency and seismic resistance of electrical cabinets in a nuclear power plant.

Model Updating of an Electric Cabinet using Shaking Table Test

  • Cui, Jintao;Cho, Sung-Gook;Kim, Doo-Kie;Koo, Ki-Young;Cho, Yang-Hee
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2008년도 춘계학술대회논문집
    • /
    • pp.59-62
    • /
    • 2008
  • This paper presents the procedure and the results of modal identification testing of a seismic monitoring system central processing unit cabinet for a nuclear power plant. This paper also provides a model updating for making effective analytical modeling of cabinet-type electrical equipment by comparing the test results with the analysis results. From the test results and their interpretation, modal properties (modal frequency, mode shape, and modal damping) of the specimen were satisfactorily identified. However, the analysis results may need to study further to find the effective and presentative model for the cabinet-type electrical equipment. This paper just presents the first stage of the research project "Development of dynamic behavior analysis technique of dynamic structure system" which is trying to build the lumped mass beam stick model even their results do not agree well with the test results.

  • PDF

한국과 서구의 가구 용어 비교 연구 - 전통 찬장을 중심으로 - (A Study on Comparison of Korean and Western Furniture Terminology - Focusing on Traditional Cupboard -)

  • 문선옥;장현영
    • 한국가구학회지
    • /
    • 제24권4호
    • /
    • pp.389-399
    • /
    • 2013
  • This study focuses a comparison of Korean and Western Furniture culture on traditional cupboard terms to make the people understand and distinguish the form of the various Korean and Western cupboard made by the craftsmanship before the industrial Revolution. As the result, the Korean cupboard shows Kangwon Chanjang/cupboard, Gyeonggi Chanjang/cupboard by the local name, dwiju Chanjang/cupboard, three-tiered Chanjang/cupboard, four-tired Chanjang/cupboard, two-tiered Chantak/cupboard, three-tiered Chantak/cupboard in the terms of the form. Korean cupboards are called Chanjang and Chantak. The Western cupboard shows cupboard, buffet, livery cupboard, cupboard-bed, corner cupboard, court cupboard, turkey-breast cupboard, pot cupboard, press, press cupboard, hall cupboard, sideboard, hunt sideboard, huntboard, cabinet, corner cabinet, writing cabinet, art cabinet, china cabinet, dresser, safe, meat safe, wall closet, wall cupboard, hanging corner cupboard, food cupboard in the terms of the various forms.

  • PDF

재래시장 전기재해 감소를 위한 실시간 확인이 가능한 분전반 개발 (Development of the Cabinet Panel of Real-Time Availability Checks for Electrical Disaster Decreasing at Traditional Markets)

  • 김기현;이상익;신성수;배석명
    • 전기학회논문지P
    • /
    • 제59권3호
    • /
    • pp.335-339
    • /
    • 2010
  • In this paper, in order to reduce the electrical disaster damage which is caused by with electrical equipment of traditional markets, we developed the cabinet panel and the electrical safety monitoring system which is able to monitor the electrical equipments condition(over current, leakage current, arc, WH, electrical fire factor etc.) at traditional markets. We constructed Test-bed for testing reliability of electrical safety monitoring system and cabinet panel. And we tested the cabinet for over current, leakage current and arc under the traditional markets actual condition. This paper will be used with the data for an demonstration project after compensating the defects which are occurred to operation of traditional markets actual loads.

안전등급 PLC 기반 제어봉제어계통 제어함 설계 (Design of Control Cabinet Based on Safety PLC for Control Rod Control System)

  • 천종민;김춘경;김석주;이종무;권순만
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2007년도 심포지엄 논문집 정보 및 제어부문
    • /
    • pp.291-292
    • /
    • 2007
  • This paper deals with the design of control cabinet based on safety PLC for Control Rod Control System(CRCS). The CRCS controls the operation of the CRDMs(Control Rod Drive Mechanisms). The CRDM moves the control rods which regulate the reactor power. vertically in the reactor core. The Control Cabinet in CRCS makes and conveys control signals to the power cabinet which provides power to the CRDM. We designed the Control Cabinet, based on POSAFE-Q, safety PLC. The application programs working in PLC can be programmed by pSET(POSAFE-Q Software Engineering Tool), Identified Development Environment.

  • PDF

서울역사박물관 소장 가께수리 약장의 연륜연대 분석 (Tree-Ring Dating for a Medicine Cabinet in Seoul Museum of History)

  • 송지애;김요정;박원규
    • 한국가구학회지
    • /
    • 제23권4호
    • /
    • pp.479-484
    • /
    • 2012
  • Tree-ring dating can be used to date scientifically prehistoric timbers, historical buildings or woodcrafts. It gives a calendar year to each tree ring and produces the felling dates of logs or wood panels. In this study, we applied tree-ring dating to a medicine cabinet in Seoul Museum of History. We obtained tree-ring data from radial or cross section by taking photographs with a digital camera. The cabinet were dated A.D. 1821 to the last ring. It was about 50 year older than the previous medicine cabinets. Tree-ring patterns indicated that the origin of woods for the cabinet would be near Sorak mountains.

  • PDF