• Title/Summary/Keyword: CV

Search Result 3,704, Processing Time 0.031 seconds

First Report of Tomato Spotted Wilt Virus in Oxypetalum coeruleum in Korea (옥시페탈룸에서 발생한 토마토반점위조바이러스 국내 첫 보고)

  • Eseul, Baek;Peter, Palukaitis;Ju-Yeon, Yoon
    • Research in Plant Disease
    • /
    • v.28 no.4
    • /
    • pp.231-236
    • /
    • 2022
  • Oxypetalum coeruleum, commonly known as Tweedia, is a perennial herbaceous plant of the Apocynaceae family native to southern Brazil and Uruguay. Tweedia plants are grown as one of the most popular ornamental flowers for floral arrangement in Korea. In May 2021, several tweedia plants in a single greenhouse in Gimje, Jeollabuk-do were found to show virus-like symptoms including necrotic rings, vein-clearing, chlorotic mottle, and mosaic on the leaves, and necrosis on the stems. Here, we have identified tomato spotted wilt virus (TSWV) in symptomatic tweedia leaves by applying high-throughput RNA sequencing. In the result, a single infection by TSWV was verified without mixed infections of different virus species. To confirm the presence of TSWV, a reverse transcription polymerase chain reaction was performed with a specific primer set to the N gene of TSWV. The complete genomic sequence of L, M, and S segments of TSWV 'Oxy' isolate were determined and deposited in GenBank under accession numbers LC671525, LC671638, and LC671639, respectively. In the phylogenetic tree analysis by maximum likelihood method, 'Oxy' isolate showed a high relationship with TSWV 'Gumi' isolate from Gerbera jamesonii in Gyeongsangbuk-do, Korea; for all three RNA segments. To our knowledge, this is the first report of TSWV infection of O. coeruleum in Korea.

Quality Changes of Hydroponically Grown 'New Raon Red' Paprika Packaged in Corrugated Box as Affected by Storage Temperature (수경재배한 미니 파프리카 '뉴라온레드' 저장온도 별 골판지박스 포장에서 수확후 특성 변화)

  • Chul Geon An;Jung-Soo Lee
    • KOREAN JOURNAL OF PACKAGING SCIENCE & TECHNOLOGY
    • /
    • v.29 no.1
    • /
    • pp.35-41
    • /
    • 2023
  • The purpose of this study was to examine the effect of each storage temperature condition of 5, 10, 15 and 20℃ to maintain the freshness of mini paprika (Capsicum annuum cv. New Raon Red) in corrugated box. Changes in general appearance, fresh weight loss, firmness, SSC (solid sugar content), and Hue angle were investigated. Furthermore, storage at temperatures ranging from 5℃ to 15℃ for 14 days resulted in maintaining freshness for 35 days. Paprika stored at 20℃ showed significantly higher loss of fresh weight and firmness than that of other storage temperatures. Furthermore, paprika stored at 5℃ and 10℃ showed a lesser decrease in hue angle than that at 15℃ and 20℃. However, the SSC of mini paprika was not significantly affected by storage temperature. These results suggest that corrugated box packaging in combination with low storage temperatures (5~10℃) could be effective in prolonging the shelf life of mini paprika. Therefore, the results represented that the low temperature storage in combination with cardboard box treatment could be effective in prolonging the shelf life of fresh paprika.

Quality Changes as affected by Storage Temperature and PP Film Packaging on 'Sirocco' Paprika on Hydroponic (수경재배한 파프리카 '시로코' 저장온도별 PP필름 개별포장 따른 수확 후 특성 변화)

  • Jung-Soo Lee
    • KOREAN JOURNAL OF PACKAGING SCIENCE & TECHNOLOGY
    • /
    • v.29 no.1
    • /
    • pp.59-65
    • /
    • 2023
  • The aim of this study was to examine the effect of packaging on the quality maintenance of paprika (Capsicum annuum L. cv. Sirocco) stored at three different temperatures. Paprika was either unpacked (control) or packed with individual PP (propylene) film and stored at 10℃ and 20℃ for 30 days. Quality characteristics such as weight loss and appearance were examined. Paprika packed with PP film at 10℃ showed fewer quality changes compared to unpacked paprika stored at the other temperatures. Commercial properties tended to decrease rapidly during storage at 20℃ with unpacked paprika. The degree of fresh weight loss was significantly lower in packed paprika at 10℃ compared to unpacked paprika stored at other temperatures. It was found that general appearance, soluble solids content, and hardness were complexly affected by storage temperature and PP film packaging. A storage temperature of 10℃ was effective in maintaining freshness, and paprika packed in PP film maintained greater freshness than unpacked paprika. Our results showed that packaging is necessary to preserve the freshness and improve the marketability of paprika in the domestic market.

A SVR Based-Pseudo Modified Einstein Procedure Incorporating H-ADCP Model for Real-Time Total Sediment Discharge Monitoring (실시간 총유사량 모니터링을 위한 H-ADCP 연계 수정 아인슈타인 방법의 의사 SVR 모형)

  • Noh, Hyoseob;Son, Geunsoo;Kim, Dongsu;Park, Yong Sung
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • v.43 no.3
    • /
    • pp.321-335
    • /
    • 2023
  • Monitoring sediment loads in natural rivers is the key process in river engineering, but it is costly and dangerous. In practice, suspended loads are directly measured, and total loads, which is a summation of suspended loads and bed loads, are estimated. This study proposes a real-time sediment discharge monitoring system using the horizontal acoustic Doppler current profiler (H-ADCP) and support vector regression (SVR). The proposed system is comprised of the SVR model for suspended sediment concentration (SVR-SSC) and for total loads (SVR-QTL), respectively. SVR-SSC estimates SSC and SVR-QTL mimics the modified Einstein procedure. The grid search with K-fold cross validation (Grid-CV) and the recursive feature elimination (RFE) were employed to determine SVR's hyperparameters and input variables. The two SVR models showed reasonable cross-validation scores (R2) with 0.885 (SVR-SSC) and 0.860 (SVR-QTL). During the time-series sediment load monitoring period, we successfully detected various sediment transport phenomena in natural streams, such as hysteresis loops and sensitive sediment fluctuations. The newly proposed sediment monitoring system depends only on the gauged features by H-ADCP without additional assumptions in hydraulic variables (e.g., friction slope and suspended sediment size distribution). This method can be applied to any ADCP-installed discharge monitoring station economically and is expected to enhance temporal resolution in sediment monitoring.

Consumers' Acceptance and Willingness to Pay for Products with Eco-Friendly Materials in Circular Economy: A Case of Clothing Made with Microplastic Emission-Reducing Materials (순환경제 시대 소비자들의 친환경 소재 제품에 대한 수용성과 지불의사: 미세플라스틱 배출저감 소재의류를 사례로)

  • Eom, Young Sook
    • Environmental and Resource Economics Review
    • /
    • v.31 no.1
    • /
    • pp.1-30
    • /
    • 2022
  • This study is to investigate consumers' acceptance and their willingness to pay for clothes made of materials with low microplastic emissions as an alternative to synthetic fibers made of plastics by applying the contingent valuation method. A nationwide web-based survey was conducted for 1,052 respondents proportional to region, age, and gender during February 2021. More than 75% of the sample expressed intentions to purchase microplastic emission-reducing clothing instead of synthetic fiber clothing, and more than 80% of them have stated their willingness to pay for additional prices. A variation of Heckman's sample selection model was adopted to estimate factors affecting respondents' intentions to pay for additional prices, in which the probit model of intentions to purchase the clothing with alternative materials was used as a sample selection equation. While respondents were sensitive to the amounts of price increases suggested in the CV scenario, they expressed high acceptance and preferences for eco-friendly materials regardless of the microplastic emission-reducing levels. Consumers in the circular economy were willing to pay for the range of 41,000 to 51,000 won for a pair of clothing made with microplastic emission-reducing materials. In addition, as the microplastic emission-reducing rate has increased from 50% to 80%, the willingness to pay estimates were also significantly increased, ranging from 41,000~50,500 to 42,000~51,700 won.

Cross-sectional perception studies of children's monosyllabic word by naive listeners (일반 청자의 아동 발화 단음절에 대한 교차 지각 분석)

  • Ha, Seunghee;So, Jungmin;Yoon, Tae-Jin
    • Phonetics and Speech Sciences
    • /
    • v.14 no.1
    • /
    • pp.21-28
    • /
    • 2022
  • Previous studies have provided important findings on children's speech production development. They have revealed that essentially all aspects of children's speech shift toward adult-like characteristics over time. Nevertheless, few studies have examined the perceptual aspects of children's speech tokens, as perceived by naive adult listeners. To fill the gap between children's production and adults' perception, we conducted cross-sectional perceptual studies of monosyllabic words produced by children aged two to six years. Monosyllabic words in the consonant-vowel-consonant form were extracted from children's speech samples and presented aurally to five listener groups (20 listeners in total). Generally, the agreement rate between children's production of target words and adult listeners' responses increases with age. The perceptual responses to tokens produced by two-year old children induced the largest discrepancies and the responses to words produced by six years olds agreed the most. Further analyses were conducted to identify the sources of disagreement, including the types of segments and syllable structure. This study makes an important contribution to our understanding of the development and perception of children's speech across age groups.

Evaluation of Variation Method to Improve the Sensitivity of Immunoradiometric Assay (면역방사계수측정법의 민감도 향상을 위한 변법의 평가)

  • Won-Hyun Kwon;Mi-Ji Kang;;Ji-Sol Park;Jung-In Kim;Kyung-Jae Lee
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.27 no.1
    • /
    • pp.29-35
    • /
    • 2023
  • Purpose The concentration of PSA (Prostate Specific Antigen) after radical prostatectomy in prostate cancer patients is a predictor of biochemical recurrence, and the AUA (American Urological Association) is defined as biochemical recurrence when the concentration of PSA is measured at 0.2 ng/mL or more, and when the concentration is measured at 0.2 ng/mL or more at the retest. This standard is also applied our hospital. In this laboratory, the PSA reagent using IRMA (Immunoradiometric Assay) is used, and the sensitivity at a very low value was not as good as the reagent used in the department of laboratory medicine. This study aims to increase the reliability of the results by improving the precision and sensitivity of very low values. Materials and Methods As a reagent for the study, PSA reagent using IRMA was used. As a method to improve the precision and sensitivity of very low values, a variation method on the serum volume(25 uL, 50 uL, 100 uL, 200 uL) was studied, and variation usefulness evaluation was conducted. The evaluation items were compared the results of precision, analytical sensitivity, recovery rate, dilution test, high-dose hook effect test, parallel test and very low concentration values(n = 20). Results The validation results were displayed in the order of 25 uL, 50 uL, 100 uL, 200 uL. As the serum volume increased, it was confirmed that CV (Coefficient of Variation)(%) improved. Analytical sensitivity(ng/mL) was 0.038, 0.041, 0.017, 0.015 and recovery rate(%) was 101±3, 101±3, 99±2, 97±4. very low concentration values(ng/mL) between each volume(n=20) were 0.135±0.068, 0.076±0.050, 0.048±0.034, 0.046±0.034. and high dose hook effect appeared as the serum volume increased. Conclusion Through the variation usefulness evaluation, it was confirmed that as the serum volume increased, the precision and sensitivity improved at very low concentration values. However, it is necessary to pay special attention to the occurrence of high-dose hook effect as the serum volume increases. In the case of tests that requires very low concentration values, it is thought that the reliability of the result will be increased if the variation method is properly used after the variation usefulness evaluation.

  • PDF

Biomechanical Properties of the Cervical Muscles Depending on Using of a Smartphone (스마트 폰 사용에 따른 경추부 근육의 생체역학성)

  • Kim, Yong-Woo;Kim, Maeng-Kyu
    • 한국체육학회지인문사회과학편
    • /
    • v.55 no.3
    • /
    • pp.543-551
    • /
    • 2016
  • The study was aimed at investigating the relationship between biomechanical properties of cervical muscles and smartphone addiction score in fifty healthy males using smartphone more than 60 minutes each day. The usage of smartphone was evaluated by smartphone addiction survey developed from Korean International Society Agency. Biomechanical properties of three major cervical muscles; splenius capitis, sternocleidomastoid and upper trapezius, were measured by Myoton, and conducted five parameters; frequency, decrement, stiffness, creep, and relaxation time. As results, all parameters had less than 2% of coefficient of variation(CV) between measurement intervals. Also, intra-class correlation coefficient(ICC) indicated a high reliability(ICC>.9, p<.01). Moreover, the smartphone addiction score was significantly different in frequency(r=.353, p<.05) and stiffness(r=.346, p<.05) on upper trapezius; in addition, in decrement(r=-.284, p<.05) and creep(r=.288, p<.05) on sternocleidomastoid. Especially, splenius capitis was closely related with the overuse of smartphone(frequency, r=-.368, p<.01; decrement, r=-.405, p<.01; stiffness, r=-.424, p<.01). In conclusion, this study implied that the overuse of smartphone is significantly related with the damage of cervical muscles, cervical pain, and headache; furthermore, Myoton can be used as an effective device to assess mechanical properties of cervical muscles.

Determination of lercanidipine in human plasma by LC-MS/MS (LC-MS/MS를 이용한 혈장 중 레르카니디핀의 분석)

  • Jang, Moon-Sun;La, Sookie;Chang, Kyu Young;Kang, Seung Woo;Han, Sang Beom;Lee, Kyung Ryul;Lee, Hee Joo
    • Analytical Science and Technology
    • /
    • v.21 no.1
    • /
    • pp.34-40
    • /
    • 2008
  • Liquid chromatography-tandem mass spectrometry (LC-MS/MS) method has been developed and validated for the quantitative determination of lercanidipine in human plasma. After addition of internal standard (amlodipine), plasma was precipitated with acetonitrile and the supernatant was evaporated. The residues were dissolved in 50 % acetonitrile and analyzed by LC-MS/MS. Using MS/MS with multiple reaction monitoring(MRM) mode, lercanindipine were selectively detected without severe interference from human plasma. The standard calibration curve for lercanidipine was linear (r = 0.9994) over the concentration range 0.05-20.0 ng/mL in human plasma. The intra- and inter-day precision over the concentration range of lercanidipine was lower than 11.7 % (correlation of variance, CV), and accuracy was between 94.4-114.8 %. This method has been successfully applied to the pharmacokinetic study of lercanidipine in human plasma.

Effects of Nutrient Solution Strength on Growth and Nutrient Element Concentrations of Leaf Lettuce by Hydroponic Culture under Artificial Light (인공광을 이용한 수경재배에서 배양액 농도가 상추의 생장과 배양액 양분 농도에 미치는 영향)

  • Kim, D.E.;Lee, W.Y.;Heo, J.W.;Lee, G.I.;Kang, D.H.;Woo, Y.H.
    • Journal of Practical Agriculture & Fisheries Research
    • /
    • v.19 no.1
    • /
    • pp.5-14
    • /
    • 2017
  • This study was conducted to investigate the effects of nutrient solution strength on growth and nutrient element concentrations in leaf lettuce (Lactuca sativa L. cv. 'Dduksum') by hydroponic culture under fluorescent lamp and LED. Leaf lettuce were grown in closed hydroponic cultivation systems supplied with 1/2, 1 and 2 strength of nutrient solution recommended by horticultural experiment station in Japan. The growth of 'Dduksum' was highest in the 2 strength of standard nutrient solution. The amount of nutrient element in the recycled nutrient solution was higher at 2, 1 and 1/2 strength of nutrient solution. The concentration of NO3-N, Ca2+, Mg2+ in the recycled nutrient solutions increased in 1 and 2 strength of nutrient solution but that of NH4-N decreased gradually in 1/2 and 1 strength of nutrient solution. The concentration of K, Ca, Mg in leaf lettuce was maintained in the normal range, whereas the concentration of phosphorous was 1.3 to 1.6%, which was higher than proper range. As the concentration of NH4-N decreases gradually in all the treatments, it is necessary to raise the rate of NH4-N or add it.