• Title/Summary/Keyword: CUSTOM

Search Result 1,335, Processing Time 0.028 seconds

The Dosimetric evaluation of the standard electron cone for the extended cone for the extended SSD and The Dosimetric characteristics of the custom-made electron cone (표준 전자선 cone의 확장된 SSD에서의 선량평가 및 자체제작한 전자선 cone의 특성)

  • Chung Se Young;Chung Hui Young;Kim Young Bum;Kwon Young Ho
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.11 no.1
    • /
    • pp.73-78
    • /
    • 1999
  • In general, the patients of the head and neck cancer are treated with 4MV photon beam up to prescribed dose, but spinal cord should be excluded in the treatment field. When its absorbed dose is limited at the tolerance dose. In case of the patients who has the positive posterior neck nodes need a boost electron beam treatment to the prescribed dose. In that case, the anatomical structure of the neck and the physical structure of the standard electron cone interrupt to allow proper access to the disease site. Therefore, we extended treatment SSD for the remove of the those hindrances. In this study, we evaluated the dosimetric variation of the standard electron cone for the extended SSD, from 100cm to 120cm, 5 cm increment, and compare to the custom-made electron cone. As a result, the $\%$ depth dose, the point of maximum dose and the range of maximum were changed within the $2\%$. The penumbra width was increased from 1.0cm to 2.0cm. However, the dosimetric characteristics of the custom-made electron cone was very similar to that of the 100cm SSD standard electron cone and due to its characteristic of physical structure, patients didn't need re-positioning after photon beam treatment, therefore accurate treatment was possible, we conclude that the custom-made electron cone was very useful for the clinical practice.

  • PDF

Accuracy of a separating foil impression using a novel polyolefin foil compared to a custom tray and a stock tray technique

  • Pastoret, Marie-Helene;Krastl, Gabriel;Buhler, Julia;Weiger, Roland;Zitzmann, Nicola Ursula
    • The Journal of Advanced Prosthodontics
    • /
    • v.9 no.4
    • /
    • pp.287-293
    • /
    • 2017
  • PURPOSE. To compare the dimensional accuracy of three impression techniques- a separating foil impression, a custom tray impression, and a stock tray impression. MATERIALS AND METHODS. A machined mandibular complete-arch metal model with special modifications served as a master cast. Three different impression techniques (n = 6 in each group) were performed with addition-cured silicon materials: i) putty-wash technique with a prefabricated metal tray (MET) using putty and regular body, ii) single-phase impression with custom tray (CUS) using regular body material, and iii) two-stage technique with stock metal tray (SEP) using putty with a separating foil and regular body material. All impressions were poured with epoxy resin. Six different distances (four intra-abutment and two inter-abutment distances) were gauged on the metal master model and on the casts with a microscope in combination with calibrated measuring software. The differences of the evaluated distances between the reference and the three test groups were calculated and expressed as mean (${\pm}SD$). Additionally, the 95% confidence intervals were calculated and significant differences between the experimental groups were assumed when confidence intervals did not overlap. RESULTS. Dimensional changes compared to reference values varied between -74.01 and $32.57{\mu}m$ (MET), -78.86 and 30.84 (CUS), and between -92.20 and 30.98 (SEP). For the intra-abutment distances, no significant differences among the experimental groups were detected. CUS showed a significantly higher dimensional accuracy for the inter-abutment distances with -0.02 and -0.08 percentage deviation compared to MET and SEP. CONCLUSION. The separation foil technique is a simple alternative to the custom tray technique for single tooth restorations, while limitations may exist for extended restorations with multiple abutment teeth.

Correctional Function of Custom Foot Orthotics for Foot Diseases related to Excessive Pronation during Gait (보행시 과도한 회내와 관련된 발질환을 위한 맞춤형 발보조기의 교정적 기능)

  • Kim, Seung-Jae
    • Korean Journal of Applied Biomechanics
    • /
    • v.16 no.1
    • /
    • pp.65-79
    • /
    • 2006
  • The purpose of this study was firstly to investigate correctional function of custom semi-rigid foot orthotics for excessively pronated people during gait by observing comfort, navicular movement and leg muscles' activity according to short-term and mid-term wearing duration and secondly to understand positive and/or negative point of view of a recently proposed paradigm related to foot orthotics more profoundly. Sixteen subjects who showed excessive pronation at navicular drop test were recruited for this study. Custom semi-rigid foot orthotics were made fitting for foot characteristics of the subjects by podiatry division of Otto Bock Korea company. While wearing the foot orthotics for two months, comfort of wearing were questioned and vertical navicular movement and electromyography of leg muscles during gait were measured at the condition of both immediately after and 2 months after including a control condition, respectively. The subjects were required to walk on a treadmill at the speed of 1.5m/s and four digital video camera filmed the movement of navicular process at the speed of 60 frames/s. In conclusion, in excessively pronated group continuous increase of comfort from short-term to mid-term wearing of custom foot orthotics is assumed to be closely related with short-term and mid term correctional action, of which are consisted the decrease of the range of navicular drop and navicular raisins- the faster timing of minimum navicular position occurring, and the decrease of leg muscles' activities. This conclusion could lead to positively accept new paradigm related to foot orthotics suggested by Nigg and the author suggest that in the future study the variable which could observe navicular movement would be one of major variables to study preferred path of skeleton in the paradigm.

A Study on the Combined custom furniture Design for Single Person Households (Focused on the art furniture table) (1인가구를 위한 조합형 커스텀 가구디자인 연구 (아트퍼니처 테이블을 중심으로))

  • Hwang, Sun-Wook
    • Journal of Digital Convergence
    • /
    • v.16 no.7
    • /
    • pp.393-400
    • /
    • 2018
  • I would like to design a customized furniture for one-person households that have emerged as mainstream in modern society. In particular, I focused on the tendency of generations to improve the quality of life, and wanted to design the aesthetic furniture close to art furniture. To this end, I look at art furniture in domestic and overseas furniture. and present the concept of combined custom design based on current trends. The combined custom design differs from the existing one by creating separate designs for each part and fusing them to enable more diverse and aggressive molding. This is in harmony with the active tendency of one-person households who shows a lot of interest in the quality of life. Especially, it is suitable for small quantity production of various kinds, so it can be produced in the existing craft workshop system, and the two tables can confirm the possibility of the morphological concept according to actual combined custom design.

Custom Cryptographic Protocol Implementation Method Based on OpenSSL (OpenSSL 기반 사용자 지정 암호 프로토콜 구현 방안)

  • Lam, JunHuy;Lee, Sang-Gon;Lee, Hoon-Jae;Andrianto, Vincentius Christian
    • Journal of the Korea Institute of Information Security & Cryptology
    • /
    • v.27 no.3
    • /
    • pp.459-466
    • /
    • 2017
  • One of the most widely-used open source project; OpenSSL is a cryptography library that is used to secure most web sites, servers and clients. One can secure the communication with the Secure Socket Layer (SSL) or its successor, Transport Layer Security (TLS) protocols by using the OpenSSL library. Since cryptography protocols will be updated and enhanced in order to keep the system protected, the library was written in such a way that simplifies the integration of new cryptographic methods, especially for the symmetric cryptography protocols. However, it gets a lot more complicated in adding an asymmetric cryptography protocol and no guide can be found for the integration of the asymmetric cryptography protocol. In this paper, we explained the architecture of the OpenSSL library and provide a simple tutorial to modify the OpenSSL library in order to accommodate custom protocols of both symmetric and asymmetric cryptography.

Effect of tightening torque on the connection stability of a custom-abutment implant system: 3D finite element analysis (지대주 나사 조임 토크가 맞춤형 지대주 임플란트 시스템의 연결부 안정성에 미치는 영향: 3차원 유한 요소 해석)

  • Hong, Min-Ho
    • Journal of Technologic Dentistry
    • /
    • v.43 no.3
    • /
    • pp.99-105
    • /
    • 2021
  • Purpose: This study aims to examine the stress distribution effect of tightening torques of different abutment screws in a custom-abutment implant system on the abutment-fixture connection interface stability using finite element analysis. Methods: The custom-abutment implant system structures used in this study were designed using CATIA program. It was presumed that the abutment screws with a tightening torque of 10, 20, and 30 N·cm fixed the abutment and fixture. Furthermore, two external loadings, vertical loading and oblique loading, were applied. Results: When the screw tightening torque was 10 N·cm, the maximum stress value of the abutment screw was 287.2 MPa that is equivalent to 33% of Ti-6Al-4V yield strength. When the tightening torque was 20 N·cm, the maximum stress value of the abutment screw was 573.9 MPa that is equivalent to 65% of Ti-6Al-4V yield strength. When the tightening torque was 30 N·cm, the maximum stress value of the abutment screw was 859.6 MPa that is similar to the Ti-6Al-4V yield strength. Conclusion: As the screw preload rose when applying each tightening torque to the custom-abutment implant system, the equivalent stress increased. It was found that the tightening torque of the abutment influenced the abutment-fixture connection interface stability. The analysis results indicate that a custom-abutment implant system should closely consider the optimal tightening torque according to clinical functional loads.

A Study on International Mercantile Custom in Russia (러시아의 국제상관습에 관한 연구)

  • Lee, Suk-Yun
    • International Commerce and Information Review
    • /
    • v.1 no.2
    • /
    • pp.295-323
    • /
    • 1999
  • A main purpose of this study is to examine the international mercantile custom of Russia. After the collapse of the Soviet Union, the new Russia have to make a relation external world for economic development. The geostrategic importance and natural resources in Russia attracted constant interest of western countries. There are many difficulties in this country and hundreds of Korean and western companies already operate in Russia and their activities are more and more of a long-tenn character. So, the settlements of trade and understanding between Korea and Russia are very important. It includes effective methods of trade settlement, factors of successful negotiation, differences of trade customs and business environment.

  • PDF

Development of FEA Custom Application System for Thermal Stress Evaluation of Skirt Type Joint Pressure Vessel (압력용기 Skirt부의 열응력 평가를 위한 유한요소해석 전문가시스템 개발)

  • Ye, Gyoo-Hyeon;Park, Dong-Sung;Choi, Kyeong-Ho
    • Journal of the Korean Society of Manufacturing Process Engineers
    • /
    • v.2 no.1
    • /
    • pp.51-56
    • /
    • 2003
  • A custom application system, which was based on the finite element analysis, for stress on the head-skirt junction of a hot pressure vessel was developed. This is useful computer-based analysis system which designed to provide an analysis technique and knowledge conveniently available to other people. It was found the evaluation of thermal stress of several typed skirt joint of a pressure vessel could be performed early using this system.

  • PDF

Fabrication of CMOS Custom LSI for Implantable Biotelemeter (바이오 텔레메-터용 CMOS Custom LSI 제작)

  • Seo, Hee-Don;Choi, Se-Gon
    • Proceedings of the KIEE Conference
    • /
    • 1987.07b
    • /
    • pp.1305-1308
    • /
    • 1987
  • This paper presents a design of an optimized implantable biotelemetry system and the fabrication of custom CMOS LSI for implementing this system. The internal circuits of this system are fabricated on a single silicon chip with a size of $4{\times}5mm^2$. This LSI is designed and fabricated not only to get as small size and low power dissipation as possible, but also to have multiple function. Its main functions are to select one of implanted sensors and to accomplish ON - OFF power switching of an implanted battery by receiving appropriate Command signals and control signals fran external circuits. The internal system which was assembled on a bread-board using fabricated LSI chip is confirmed to work as designed. The total power dissipation of this interal system was $10.12{\mu}W$.

  • PDF

A Design of Digital Filter IC Using a Semi-Custom Design Method (Semi-Custom 방식을 이용한 통신용 디지탈 필터의 집적회로 설계)

  • Lee, Kwang-Youb;Kim, Bong-Ryul;Lee, Moon-Key
    • Proceedings of the KIEE Conference
    • /
    • 1987.07b
    • /
    • pp.850-853
    • /
    • 1987
  • A VLSI digital filter design using a semi-custom method is described. The digital filters composed of TDM/FDM Transmultiplexer are designed. Using the polyphase network approach a filter bank composed of only all-pass digital filter sections was designed. The use of all-pass filters as basic building blocks is shown to provide a transmultiplexer structure that has low computational requirements, low quantization noise, and high modularity. The silicon compiler systems is used to reduce the design time and increase the credibility of designed filters. A design of 1st order and 2nd order all pass filters is done using CMOS 2um N-well double metal cell.

  • PDF