• 제목/요약/키워드: CT-guided

Search Result 230, Processing Time 0.024 seconds

Evaluation of the Accuracy and Precision Three-Dimensional Stereotactic Breast Biopsy (3차원 입체정위 유방생검술의 정확도 및 정밀도 평가)

  • Lee, Mi-Hwa
    • Journal of radiological science and technology
    • /
    • v.38 no.3
    • /
    • pp.213-220
    • /
    • 2015
  • This research was study the accuracy of three-dimensional stereotactic breast biopsy, using a core Needle Biopsy and to assess the accuracy of Stereotactic biopsy and Sono guided biopsy. Using Stereotactic QC phantom to measure the accuracy of the 3D sterotactic machine. CT Scan and equipment obtained in the measured X, Y, Z and compares the accuracy of the length. Using Agar power phantom compare the accuracy of the 3D sterotactic machine and 2D ultrasound machine. Z axis measured by the equipment to compare the accuracy and reliability. Check the accuracy by using visual inspection and Specimen Medical application phantom. The accuracy of the 3D sterotactic machine measured by Stereotactic QC phantom was 100%. Accuracy as compared to CT, all of X, Y, Z axis is p > 0.05. The accuracy of the two devices was 100% as measured by Agar powder phantom. There was no difference between t he t wo d evices as C T and p > 0.05. 3D sterotactic machine of the ICC was 0.954, 2D ultrasound machine was 0.785. 2D ultrasound machine was different according to the inspector. Medical application phantom experiments in 3D sterotactic machine could not find the Sliced boneless ham. 2D ultrasound machine has not been able to find a small chalk powder group. The reproducibility of the three-dimensional stereotactic breast biopsy was better than effect of Sono guided biopsy.

Kidney Tumor Segmentation through Semi-supervised Learning Based on Mean Teacher Using Kidney Local Guided Map in Abdominal CT Images (복부 CT 영상에서 신장 로컬 가이드 맵을 활용한 평균-교사 모델 기반의 준지도학습을 통한 신장 종양 분할)

  • Heeyoung Jeong;Hyeonjin Kim;Helen Hong
    • Journal of the Korea Computer Graphics Society
    • /
    • v.29 no.5
    • /
    • pp.21-30
    • /
    • 2023
  • Accurate segmentation of the kidney tumor is necessary to identify shape, location and safety margin of tumor in abdominal CT images for surgical planning before renal partial nephrectomy. However, kidney tumor segmentation is challenging task due to the various sizes and locations of the tumor for each patient and signal intensity similarity to surrounding organs such as intestine and spleen. In this paper, we propose a semi-supervised learning-based mean teacher network that utilizes both labeled and unlabeled data using a kidney local guided map including kidney local information to segment small-sized kidney tumors occurring at various locations in the kidney, and analyze the performance according to the kidney tumor size. As a result of the study, the proposed method showed an F1-score of 75.24% by considering local information of the kidney using a kidney local guide map to locate the tumor existing around the kidney. In particular, under-segmentation of small-sized tumors which are difficult to segment was improved, and showed a 13.9%p higher F1-score even though it used a smaller amount of labeled data than nnU-Net.

Image-guided radiation therapy in lymphoma management

  • Eng, Tony;Ha, Chul S.
    • Radiation Oncology Journal
    • /
    • v.33 no.3
    • /
    • pp.161-171
    • /
    • 2015
  • Image-guided radiation therapy (IGRT) is a process of incorporating imaging techniques such as computed tomography (CT), magnetic resonance imaging (MRI), Positron emission tomography (PET), and ultrasound (US) during radiation therapy (RT) to improve treatment accuracy. It allows real-time or near real-time visualization of anatomical information to ensure that the target is in its position as planned. In addition, changes in tumor volume and location due to organ motion during treatment can be also compensated. IGRT has been gaining popularity and acceptance rapidly in RT over the past 10 years, and many published data have been reported on prostate, bladder, head and neck, and gastrointestinal cancers. However, the role of IGRT in lymphoma management is not well defined as there are only very limited published data currently available. The scope of this paper is to review the current use of IGRT in the management of lymphoma. The technical and clinical aspects of IGRT, lymphoma imaging studies, the current role of IGRT in lymphoma management and future directions will be discussed.

Computed tomography-guided 3D printed patient-specific regional anesthesia

  • Jundt, Jonathon S.;Chow, Christopher C.;Couey, Marcus
    • Journal of Dental Anesthesia and Pain Medicine
    • /
    • v.20 no.5
    • /
    • pp.325-329
    • /
    • 2020
  • Classic anesthetic techniques for the inferior alveolar nerve, lingual nerve, and long buccal nerve blockade are achieved by estimating the intended location for anesthetic deposition based on palpation, inspection, and subsequent correlation for oral anatomical structures. The present article utilizes computed tomography (CT) data to 3D print a guide for repeatable and accurate deposition of a local anesthetic at the ideal location. This technical report aims to anatomically define the ideal location for local anesthetic deposition. This process has the potential to reduce patient discomfort, risk of nerve damage, and failed mandibular anesthesia, as well as to reduce the total anesthetic dose. Lastly, as robotic-based interventions improve, this provides the initial framework for robot-guided regional anesthesia administration in the oral cavity.

Impact of Respiratory Phase during Pleural Puncture on Complications in CT-Guided Percutaneous Lung Biopsy (CT 유도 경피 폐생검에서 흉막 천자 시 호흡 시기가 합병증에 미치는 영향)

  • Ji Young Park;Ji-Yeon Han;Seok Jin Choi;Jin Wook Baek;Su Young Yun;Sung Kwang Lee;Ho Young Lee;SungMin Hong
    • Journal of the Korean Society of Radiology
    • /
    • v.85 no.3
    • /
    • pp.566-578
    • /
    • 2024
  • Purpose This study investigated whether the respiratory phase during pleural puncture in CT-guided percutaneous transthoracic needle biopsy (PTNB) affects complications. Materials and Methods We conducted a retrospective review of 477 lung biopsy CT scans performed during free breathing. The respiratory phases during pleural puncture were determined based on the table position of the targeted nodule using CT scans obtained during free breathing. We compared the rates of complications among the inspiratory, mid-, and expiratory respiratory phases. Logistic regression analysis was performed to control confounding factors associated with pneumothorax. Results Among the 477 procedures, pleural puncture was performed during the expiratory phase in 227 (47.6%), during the mid-phase in 108 (22.6%), and during the inspiratory phase in 142 (29.8%). The incidence of pneumothorax was significantly lower in the expiratory puncture group (40/227, 17.6%; p = 0.035) and significantly higher in the mid-phase puncture group (31/108, 28.7%; p = 0.048). After controlling for confounding factors, expiratory-phase puncture was found to be an independent protective factor against pneumothorax (odds ratio = 0.571; 95% confidence interval = 0.360-0.906; p = 0.017). Conclusion Our findings suggest that pleural puncture during the expiratory phase may reduce the risk of pneumothorax during image guided PTNB.

Automatic Bone Segmentation from CT Images Using Chan-Vese Multiphase Active Contour

  • Truc, P.T.H.;Kim, T.S.;Kim, Y.H.;Ahn, Y.B.;Lee, Y.K.;Lee, S.Y.
    • Journal of Biomedical Engineering Research
    • /
    • v.28 no.6
    • /
    • pp.713-720
    • /
    • 2007
  • In image-guided surgery, automatic bone segmentation of Computed Tomography (CT) images is an important but challenging step. Previous attempts include intensity-, edge-, region-, and deformable curve-based approaches [1], but none claims fully satisfactory performance. Although active contour (AC) techniques possess many excellent characteristics, their applications in CT image segmentation have not worthily exploited yet. In this study, we have evaluated the automaticity and performance of the model of Chan-Vese Multiphase AC Without Edges towards knee bone segmentation from CT images. This model is suitable because it is initialization-insensitive and topology-adaptive. Its segmentation results have been qualitatively compared with those from four other widely used AC models: namely Gradient Vector Flow (GVF) AC, Geometric AC, Geodesic AC, and GVF Fast Geometric AC. To quantitatively evaluate its performance, the results from a commercial software and a medical expert have been used. The evaluation results show that the Chan-Vese model provides superior performance with least user interaction, proving its suitability for automatic bone segmentation from CT images.

CT Guided Celiac plexus Block (CT를 이용한 복강신경총 차단)

  • Kim, Jong-Il;Park, No-Cheon;Go, Joon-Seock;Min, Byung-Woo
    • The Korean Journal of Pain
    • /
    • v.1 no.1
    • /
    • pp.28-33
    • /
    • 1988
  • Neurolysis of the celiac plexus has been performed to relieve intractable pain caused by carcinoma of the pancreas, liver, gall bladder or stomach. It is also occasionally effective in controlling the pain of chronic pancreatitis. In practice, however celiac plexus block is not a simple procedure to the beginner. The results and complications are variable. In order to correctly inject neurolytic agents into or near the celiac plexus and to reduce the time consumed to perform celiac plexus block, we used CT scanner for 7 cases of alcohol celiac plexus block. The effects will be described. The purpose of this article is to improve the technical aspect of celiac plexus block to the beginner.

  • PDF

The Case Report of Posterior Headache Caused by Traffic Accident Treated with Musculoskeletal Ultrasound-guided Acupotomy Therapy (교통사고 후 발생한 후두통의 근골격계 초음파를 이용한 침도치료 임상증례)

  • Park, Man-Yong;Kim, Sung-Ha;Lee, Sang-Mi;Lee, Jong-Deok;Lim, Jin-Young;Kwon, So-Yeon;Jung, Il-Min;Kim, Sung-Chul
    • Journal of Acupuncture Research
    • /
    • v.28 no.2
    • /
    • pp.165-172
    • /
    • 2011
  • Objectives : The objective of this case report was to observe the effect of musculoskeletal ultrasound-guided acupotomy therapy on posterior headache caused by traffic accident. Methods : Musculoskeletal ultrasound-guided acupotomy therapy was performed to two patients whose brain MRI or CT results were normal, but posterior headache did not improve with general eastern medical treatment. Results : One patient's VAS(visual analogue scale) of posterior headache was decreased for the first time after ultrasound-guided acupotomy therapy, and steadily reduced. The other patient's VAS was also decreased for the first time after musculoskeletal ultrasound-guided acupotomy therapy. Two patient's Korean HIT-6(Korean headache impact test-6) scores were decreased after one month. Conclusions : If general eastern medical treatment had little effect on traffic accident induced posterior headache, musculoskeletal ultrasound-guided acupotomy therapy can be applied.

Cytologic Diagnosis of Hepatocellular Carcinoma by Fine-Needle Aspiration Biopsy (세침 흡인 생검에 의한 간암의 세포학적 진단)

  • Kim, Ki-Kwon;Chang, Eun-Sook
    • The Korean Journal of Cytopathology
    • /
    • v.1 no.1
    • /
    • pp.18-26
    • /
    • 1990
  • CT guided percutaneous fine-needle aspiration (FNA) of the liver for both cytologic and histologic examination has great value in diagnosing liver malignancy. From March, 1986 to April, 1990, 62 patients with the clinical impression of liver malignancy underwent CT guided percutaneous FNA biopsy. Of these, 43 cases were reviewed for this study, 19 were reported to be liver cell carcinoma, 2 were adenocarcinoma, 11 were reported as anaplastic cell present, and the rest (11 cases) were negative (9) or necrotic (2). Among the 11 cases of the last group, 9 were diagnosed as liver cell carcinoma and 2 were necrotic histologically. Retrospective review, in order to clarify the cause of cytologic diagnostic error, of both cytologic and histologic slides of all cases showed discordance of 23% between these diagnoses and sensitivity is 93.9% and specificity is 90.9%. The reasons were as follows ; 1) the lack of awareness of tumor cells of well differentiated liver cell carcinoma (4 cases), 2) missed tumor cells due to too scanty cellularity (1 case), 3) improper smear (2 cases) and no tumor cell In the cytologic smears (3 cases). In such cases, at the initiation of FNA, a correct diagnosis of liver malignancy could only be made by a combination of cytologic and histologic examinations. However after three years' experience we can conclude that cytomorphologic features of liver cell carcinoma are sufficiently distinctive from other liver malignancies to be diagnostic.

  • PDF

Gross tumor volume dependency on phase sorting methods of four-dimensional computed tomography images for lung cancer

  • Lee, Soo Yong;Lim, Sangwook;Ma, Sun Young;Yu, Jesang
    • Radiation Oncology Journal
    • /
    • v.35 no.3
    • /
    • pp.274-280
    • /
    • 2017
  • Purpose: To see the gross tumor volume (GTV) dependency according to the phase selection and reconstruction methods, we measured and analyzed the changes of tumor volume and motion at each phase in 20 cases with lung cancer patients who underwent image-guided radiotherapy. Materials and Methods: We retrospectively analyzed four-dimensional computed tomography (4D-CT) images in 20 cases of 19 patients who underwent image-guided radiotherapy. The 4D-CT images were reconstructed by the maximum intensity projection (MIP) and the minimum intensity projection (Min-IP) method after sorting phase as 40%-60%, 30%-70%, and 0%-90%. We analyzed the relationship between the range of motion and the change of GTV according to the reconstruction method. Results: The motion ranges of GTVs are statistically significant only for the tumor motion in craniocaudal direction. The discrepancies of GTV volume and motion between MIP and Min-IP increased rapidly as the wider ranges of duty cycles are selected. Conclusion: As narrow as possible duty cycle such as 40%-60% and MIP reconstruction was suitable for lung cancer if the respiration was stable. Selecting the reconstruction methods and duty cycle is important for small size and for large motion range tumors.