• Title/Summary/Keyword: CT-Image

검색결과 1,671건 처리시간 0.03초

Moire 영상을 이용한 근골격계 질환의 한의학적 진단에 관한 연구 (A Study on Oriental Medical Diagnosis of Musculoskeletal Disorders using Moire Image)

  • 이은경;유승현;이수경;강성호;한종민;정명수;천은주;송용선;이기남
    • 대한예방한의학회지
    • /
    • 제4권2호
    • /
    • pp.72-92
    • /
    • 2000
  • This research has conducted studies on an Oriental medicine-based method of diagnosing of occupational musculoskeletal system diseases. This researcher has searched through existing relevant medical literature. Also, this researcher has worked on a moire topography using moire topography. In this course, this researcher has reached the following conclusion in relation to the possibility of using a moire topography as a diagnosing device of musculoskeletal system diseases under Oriental medicine . 1 The Western medicine outlines its criteria of screening occupational musculoskeletal system diseases as follows A. The occupational musculoskeletal diseases must clearly include one or more of the subjective symptoms characterized by pain, hypoesthesia dysaesthesia, anaesthesia. etc . B, There should be clinically admitted objective observations and diagnosis outlining that the disease concerned shows symptoms such as tenderness, induration. and edema that can appear with occupational musculoskeletal system diseases. dyscinesia should be admitted with the disease concerned, or there should be observations and diagnosis outlining that abnormality exists in electric muscular or nervous diagnosis and examination . C. It should be admitted that prior to the occurrence of symptoms or observations and diagnosis on musculoskeletal system-related diseases, a patient has been engaged in works with conditions requiring improper work posture or work movement. That is, this is an approach whereby they see abnormality in the musculoskeletal system come from material and structural defect, and adjust and control abnormality in the musculoskeletal system and secreta . 2. The Oriental medicines sees that a patient develops the pain of occupational musculoskeletal diseases as he cannot properly activate the flow of his life force and blood thus not only causing formation of lumps in the body and blocking the flow of life force and blood in some parts of the body. Hence, The Oriental medicine focuses on resolving the cause of weakening the flow of life force and blood, instead of taking material approach of correcting structural abnormality Furthermore , Oriental medicine sees that when muscle tension builds up, this presses blood vessels and nerves passing by, triggering circulation dyscrasia and neurological reaction and thus leading to lesion. Thus, instead of taking skeletal or neurophysiological approach. it seeks to fundamentally resolve the cause of the flow of the life force and blood in muscles not being activated. As a result Oriental medicine attributes the main cause of musculoskeletal system diseases to muscle tension and its build-up that stem from an individual's long formed chronicle habit and work environment. This approach considers not only the social structure aspect including companies owners and work environment that the existing methods have looked at, but also individual workers' responsibility and their environmental factors. Hence, this is a step forward method. 3 The diagnosis of musculoskeletal diseases under Oriental medicine is characterized by the fact that an Oriental medicine doctor uses not only photos taken by himself, but also various detection devices to gather information and pass comprehensive judgment on it. Thus, it is the core of diagnosis under Oriental medicine to develop diagnosing devices matching the characteristics of information to be induced and to interpret information so induced from the views of Oriental medicine. Diagnosis using diagnosing devices values the whole state of a patient and formal abnormality alike, and the whole balance and muscular state of a patient serves as the basis of diagnosis. Hence, this method, instead of depending on the information gathered from devices under Western medicine, requires devices that provide information on the whole state of a patient in addition to the local abnormality information that X-ray. CT, etc., can offer. This method sees muscle as the central part of the abnormality in the musculoskeletal system and thus requires diagnosing devices enabling the muscular state. 4. The diagnosing device using moire topography under Oriental medicine has advantages below and can be used for diagnosing musculoskeletal system diseases with industrial workers . First, the device can Provide information on the body in an unbalanced state. and thus identify the imbalance and difference of height in the left and right stature that a patient can not notice at normal times. Second, the device shows the twisting of muscles or induration regions in a contour map. This is not possible with existing shooting machines such as X-ray, CT, etc., thus differentiating itself from existing machines. Third, this device makes it possible for Oriental medicine to take its unique approach to the abnormality in the musculoskeletal system. Oriental medicine sees the state and imbalance state in muscles as major factors in determining the lesion of musculoskeletal system, and the device makes it possible to shoot the state of muscles in detail. In this respect, the device is significant. Fourth, the device has an advantage as non-aggression diagnosing device.

  • PDF

비인두암 환자에 대한 세기조절 방사선치료 시 이용되는 MVCT와 kV-CBCT의 수정체 흡수선량 평가 (Evaluation of the Lens Absorbed Dose of MVCT and kV-CBCT Use for IMRT to the Nasopharyngeal Cancer Patient)

  • 최재원;김철종;박수연;송기원
    • 대한방사선치료학회지
    • /
    • 제25권2호
    • /
    • pp.131-136
    • /
    • 2013
  • 목 적: 비인두암(Nasopharyngeal cancer) 환자를 세기조절 방사선치료(IMRT)시 영상유도 촬영(MVCT & kV-CBCT)에서의 수정체 흡수선량(absorbed dose)을 평가하고자 한다. 대상 및 방법: 인체모형팬텀(Anderson rando phantom, Alderson Reserch Laboratories Inc., USA)을 대상으로 전산화 단층촬영(lightspeed ultra 16, General Electric, USA)을 실시하였고 획득되어진 이미지를 비인두암 환자의 치료계획에 동일한 조건으로 토모세라피 치료계획장치(Tomotherapy, Inc, USA)와 선형가속기 치료계획장치(Pinnacle 8.0, philips Medicle System)로 동일하게 수립하였다. 열형광선량계(TLD100 Harshaw USA)를 수정체 위치에 위치시키고 토모세라피 MVCT를 세 가지 조건(fine, normal, coarse)에서 촬영, kV-CBCT를 두 가지 조건(low dose head, standard dose head)에서 각각 좌우 3번씩 반복 측정하였다. 결 과: 토모세라피와 선형가속기를 이용하여 실시한 MVCT와 kV-CBCT 촬영 시 수정체의 흡수선량을 측정한 결과 토모세라피 MVCT에서 coarse의 경우 RT 0.8257 cGy, LT 0.8137 cGy, normal의 경우 RT 1.089 cGy, LT 1.188 cGy, fine의 경우 RT 2.154 cGy, LT 2.082 cGy라는 결과를 얻을 수 있었다. 선형가속기 kV-CBCT에선 standard mode의 경우 RT 0.2875 cGy, LT 0.1676 cGy, Low-dose mode의 경우 RT 0.1648 cGy, LT 0.1212 cGy로 나타났다. MVCT와 kV-CBCT의 최대 차이는 약20배 이상인 것을 알 수 있다. 결 론: kV-CBCT가 MVCT을 통해 영상유도 이미지를 얻는 것보다 수정체 흡수선량만으로 고려하였을 때 세기조절 방사선 치료 시 환자가 치료 이외에 받는 선량을 줄일 수 있다고 판단된다. 또한 동일한 치료 장비라 하더라도 다양한 촬영조건에 따라 선량차이가 있다는 것을 알 수 있다.

  • PDF

폐 병소의 경피적 흡인 생검 시 기흉 발생 관련 요인 (Related Factors of Pneumothorax after Percutaneous Needle Aspiration Biopsy)

  • 이보우;배석환;이무식;이진용;김철웅;조범상;유세종;황지혜
    • 대한방사선기술학회지:방사선기술과학
    • /
    • 제34권3호
    • /
    • pp.203-208
    • /
    • 2011
  • 본 연구는 폐 병소의 경피적 흡인 생검을 시행하는데 있어 기흉 발생에 영향을 미치는 요인을 분석하였다. 대전광역시 일개 대학병원에서 2007년 8월부터 2008년 5월까지 국소적인 폐 병소를 보인 25~85세 사이의 104명의 환자를 대상으로 하였으며, 병변의 위치, 병변의 크기, 병변의 깊이, 성별, 나이, 생검 시간, 생검횟수로 나누어 기흉 발생과의 연관성을 연구하였다. 위치에 따른 기흉 발생률은 우하엽에서 27.3%, 우상엽 24.3%, 좌하엽 15%, 좌상엽 12% 순으로 나타났다. 병변의 크기에 따른 기흉 발생률은 0~2.0 cm에서 24.0%, 2.1~4.0 cm에서 18.2%, 4.1 cm 이상에서 20.0%였다. 병변의 깊이에 따른 기흉 발생률은 0 cm에서 6.7%, 0.1~2.0 cm에서 24.2%, 2.1 cm 이상인 경우가 26.8%였다. 성별에 따른 기흉의 발생은 남성 21.7%, 여성 17.1%로 나타났다. 나이에 따른 기흉 발생은 40세 이하가 25%, 41~50세가 11.7%, 51~60세가 14.3%, 61~70세가 24.1%, 70세 이상이 24.1%로 나타났다. 생검에 걸리는 시간에 따른 기흉 발생률은 0~10.0분에서 3.8%, 10.1~20.0분에서 18.9%, 21분 이상에서 40%였다. 생검 시행 횟수에 따른 기흉 발생률은 4회 이상에서 28.6%, 2회 이하에서 20.5%, 3회에서 17.4%로 각각 나타났다. 기흉 발생에 영향을 미치는 변수는 생검에 걸리는 시간이 유의한 차이를 나타냈으며, 시간이 길수록 기흉 발생률이 증가하였다.

강남세브란스병원 토모테라피를 이용한 치료환자의 130예 통계분석 및 경험 (Experiences of the First 130 Patients in Gangnam Severance Hospital)

  • 하진숙;전미진;김세준;김종대;신동봉
    • 대한방사선치료학회지
    • /
    • 제20권1호
    • /
    • pp.45-53
    • /
    • 2008
  • 목 적: 본원에 2007년 10월에 설치된 토모테라피를 이용하여 치료한 환자 130명에 대하여 치료의 통계적 특성을 분석하여 종양의 부위별, 종양표적체적의 변화, 전체치료시간(overall treatment time), 초고압전산화단층촬영(Megavoltage computed tomography; MVCT)을 이용한 환자의 이동 값, 종양의 크기 변화에 따른 보정치료계획(Adaptive plan) 필요성 등에 대한 통계를 분석하여 알아보고자 한다. 대상 및 방법: 본원에서 2007년 10월부터 2008년 8월까지 토모테라피를 받은 130명의 환자를 대상으로 조사하였다. 환자의 평균 연령은 53세(최소 25세, 최고 83세)이고, 치료 부위별로 두경부(22명), 흉부(47명), 복부(25명), 골반부(11명), 골격계(25명) 로 나누었으며 MVCT는 2,702번의 총 분할조사를 치료 전 100% 시행하였고 종양의 크기변화가 큰 27명은 보정치료계획을 시행하였다. 또한 획득된 MVCT와 kV-CT를 일치시킨 후 이동된 값(X, Y, Z, roll, vector)을 치료부위와 사용된 고정기구의 평균 오차범위를 조사하였고 위치잡이(set up), MVCT, 평균 전체치료시간, 표적체적(target volume; TV)을 조사하였다. 결 과: 분석결과 환자가 카우치에 누워있는 평균시간은 22.8분, 평균 치료시간은 13.46분, 평균 보정계수(mm) X=-0.7, Y=-1.4, Z=5.77, roll=0.29, vector=8.66으로 평균 육안적종양체적(gross tumor volume; GTV)=229 $cm^3$, 평균 임상표적체적(clinical tumor volume; CTV)=564 $cm^3$으로 나타났다. 흉부, 복부, 골격계 치료환자보다 두경부 환자의 이동된 vector값이 2.96 mm적음을 알 수 있었다. 치료부위별 이동된 vector값이 두경부>골격계>복부>흉부>골반부 순서로 나타났다. 또한, 보정치료 계획을 시행한 환자는 27명, 종양이 길거나 다발성 종양환자는 39명이며 치료 시 1개의 치료계획으로 치료할 때 전체치료시간은 32분, 2개의 치료계획으로 나누어 치료 시에는 각각 21분, 19분으로 총 40분 소요되는 것을 알 수 있었다. 결 론: 고정용구의 사용과 더불어 MVCT의 적용으로 더욱 정확한 세기조절방사선치료(intensity modulated radiation therapy; IMRT)를 할 수 있었다. 또한 매일 영상을 통해 종양의 변화를 확인하여 보정치료계획을 할 수 있었으며 종양이 길거나 또는 다발성 종양, 손상위험장기(organ at risk; OAR) 근처의 치료와 급격한 선량분포의 변화를 주어야 하는 복잡한 치료를 가능하게 하였다.

  • PDF

토끼 두개골 결손부에서 전기 방사된 나노실크-수산화인회석 복합체를 이용한 골재생 효과에 대한 연구 (Electrospun Silk Nano-Fiber Combined with Nano-Hydoxyapatite Graft for the Rabbit Calvarial Model)

  • 계준영;김성곤;김민근;권광준;박영욱;김좌영;이민정;박영환
    • Maxillofacial Plastic and Reconstructive Surgery
    • /
    • 제32권4호
    • /
    • pp.293-298
    • /
    • 2010
  • Purpose: The objective of the present study was to determine the capability of electrospun silk fibroin as a biomaterial template for bone formation when mixed with nano-hydoxyapatite in vivo. Materials and Methods: Ten New Zealand white rabbits were used for this study and bilateral round shaped defects were formed in the parietal bone (diameter: 8.0 mm). The electrospun silk fibroin was coated by nano-hydroxyapatite and grafted into the right parietal bone (experimental group). The left side (control group) did not receive a graft. The animals were sacrificed at 6 weeks and 12 weeks, humanly. The microcomputerized tomogram (${\mu}CT$) was taken for each specimen. Subsequently, they were undergone decalcification and stained for the histological analysis. Results: The average value of all measured variables was higher in the experimental group than in the control at 6 weeks after the operation. BMC in the experimental group at 6 weeks after operation was $48.94{\pm}19.25$ and that in the control was $26.17{\pm}16.40$ (P = 0.027). BMD in the experimental group at 6 weeks after operation was $324.59{\pm}165.24$ and that in the control was $173.03{\pm}120.30$ (P = 0.044). TMC in the experimental group at 6 weeks after operation was $19.50{\pm}6.00$ and that in the control was $10.52{\pm}6.20$ (P = 0.011). TMD in the experimental group at 6 weeks after operation was $508.88{\pm}297.57$ and that in the control was $273.54{\pm}175.91$ (P = 0.06). Gross image of both groups showed higher calcification area at 12 weeks than them in 6 weeks. The average value of ${\mu}CT$ analysis was higher at 12 weeks than that in 6 weeks in both groups. BMC in the experimental group at 12 weeks after operation was $51.21{\pm}8.81$ and that in the control was $33.47{\pm}11.13$ (P = 0.010). BMD in the experimental group at 12 weeks after operation was $323.39{\pm}21.54$ and that in the control was $197.75{\pm}76.23$ (P = 0.012). TMC in the experimental group at 12 weeks after operation was $21.44{\pm}5.30$ and that in the control was $13.31{\pm}4.17$ (P = 0.008). TMD in the experimental group at 12 weeks after operation was $524.47{\pm}19.37$ and that in the control was $299.60{\pm}136.20$ (P = 0.016). Conclusion: The rabbit calvarial defect could be successfully repaired by electrospun silk nano-fiber combined with nano-hydroxyapatite.

NPC의 방사선치료시 3D-CRT, IMRT, Tomotherapy의 유용성 분석 (The Usability Analysis of 3D-CRT, IMRT, Tomotherpy Radiation Therapy on Nasopharyngeal Cancer)

  • 송종남;김영재;홍성일
    • 한국방사선학회논문지
    • /
    • 제6권5호
    • /
    • pp.365-371
    • /
    • 2012
  • 암환자의 방사선 치료기술은 3D-CRT, IMRT, Tomotherapy로 발전해 가고 있으며 이 3가지의 치료법은 임상에서 가장 많이 쓰이는 방사선 치료기술이다. 본 연구에서는 3D-CRT, IMRT(Linac Based) 그리고 Tomotherapy 치료시 정상조직과 종양조직의 선량분포를 비교해 보고자 한다. 실험방법으로는 조직 등가물질로 이루어진 인체모형팬톰 (Anthropomorphic Phantom)을 대상으로 CT simulation을 실시(Slice Thickness : 3mm)하여 획득된 영상에 GTV를 비인두 부위로 정하고 PTV는 GTV에 2mm정도의 영역을 포함시켜 치료계획용 장비(ADAC-Pinnacle3. Tomotherapy Hi-Art System)으로 전송한다. 치료계획은 PTV의 처방선량을 7020 cGy로 설정한 후 PTV에 부여되는 선량값과 정상조직인 이하선, 구강, 척수에 흡수되는 선량값을 산출하였다. 실험결과 PTV에 분포된 선량값은 Tomotherapy, Linac Based - IMRT, 3D-CRT가 각각 6923 cGy, 6901 cGy, 6718 cGy의 선량분포를 보여 종양조직 처방선량값인 7020 cGy의 95%이상 부여되어 종양제어측면(TCP)에 부합하였으며 정상조직(이하선, 구강, 척수)은 각각 1966 cGy (Tomotherapy), 2405 cGy(IMRT), 2468 cGy(3D-CRT)[이하선], 2991 cGy(Tomotherapy), 3062 cGy(IMRT), 3684 cGy(3D-CRT)[구강], 1768 cGy(Tomotherapy), 2151 cGy(IMRT), 4031 cGy(3D-CRT)[척수]의 선량이 분포되었으며 이는 정상조직 합병증발생율(NTCP)의 선량을 넘지 않았다. 모든 치료기법에서 종양조직과 정상조직이 선량분포측면에 부합하였다. 3D-CRT의 치료법이 선량분포 면에서 가장 양호하지 않았지만 종양조직제어율(TCP)과 정상조직합병증율(NTCP)을 고려해 볼 때 기준치를 벗어나지 않는 선량이 분포 되었다. 상대적으로 선량분포가 우수한 Tomotherapy, IMRT는 오랜 치료시간 때문에 폐쇄공포증환자나 호흡불량 환자가 치료받는데 어려울 수 있다. 특히 토모테라피의 경우 치료 전에 고에너지 컴퓨터 단층촬영을 매일 실시하기 때문에 불필요한 방사선 피폭을 초래할 수 있다. 결론적으로 Tomotherapy가 선량분포에서 가장 우수한 치료기법으로 평가되었으며, IMRT, 3D-CRT의 순으로 방사선치료의 적합성을 보였다. 하지만 실제 치료시 환자의 상태에 따라 제한적으로 3차원 입체조형치료를 시행하여도 무방하다고 사료된다.

흥부 전산화단층촬영을 이용한 한국성인의 기관내경과 단면적의 측정 (CT Measurement of Diameter and Dimension of the Trachea in Normal Korean Adults)

  • 한재열;김광호;이건;김형진;조순구;선경
    • Journal of Chest Surgery
    • /
    • 제34권7호
    • /
    • pp.534-538
    • /
    • 2001
  • 배경: 기관의 크기와 기관주위의 정상형태에 대한 지식은 임상에서 기도나 호흡관리, 그리고 기관재건술을 시행하는데 중요한 정보가 된다. 흉부 단순촬영은 기관의 직경을 재는 간단한 방법이지만 그 상이 확대되는 경향과 측면촬영에서 어깨와 상이 겹쳐서 나타나는 단점이 있다. 이에 저자들은 한국인 정상 성인의 기관의 정상치를 알기 위해 흥부 전산화 단층촬영을 이용하여 기관의 내경과 단면적을 측정하였다. 대상 및 방법: 남자 43명과 여자34명을 대상으로 하여 각각 나이에 따라 20~39세는 제 1군, 40~59세는 제2군, 60세 이상은 제 3군으로 구분하였다. 흉부 유입구와(Level 1) 대동맥궁에서(Level 2) 흉부 전산화 단층촬영을 이용하여 각각 전후경과 횡경을 재고 그 단면적을 구하였다. 결과: level 1에서 한국인 성인 남자의 기관의 전후경은 15.95$\pm$2.99 m, 횡경은 17.72$\pm$2.13 m이었고, 여자의 경우 전후경은 15.56$\pm$2.12 m, 횡경은 14.18$\pm$2.07mm로 남녀간에 유의한 차이가 있었다(p 0.05). Level 2에서 남자의 전후경은 19.77$\pm$2.57 m, 횡경은 18.02$\pm$2.19 mm이었고 여자의 전후경은 15.35$\pm$1.82 m, 횡경은 15.00$\pm$1.60 mm로 남녀간에 유의한 차이가 있었다 (p 0.05). 기관단면적은 남자가 각 Level에서 279.14$\pm$61.37 $\textrm{mm}^2$(Level 1), 281.93$\pm$63.97 $\textrm{mm}^2$(level 2)였고, 여자가 173.29$\pm$35.81 $\textrm{mm}^2$(Level 1), 181.88$\pm$34.74 $\textrm{mm}^2$(Level 2)로 두 위치에서 단면적은 남녀간에 유의한 차이가 있었다(p 0.05). 기관의 각각의 위치에서 내경과 단면적은 연령군에 따라 고연령층에서 증가하는 추세를 나타내었으나 통계적인 의미는 없었다. 결론: 한국 정상 성인의 기관내경과 단면적의 크기는 성별에 따라 통계적으로 유의한 차이가 있었으나 연령에 따른 차이는 없었고, 전산화 단층촬영은 기관의 내경과 단면적의 크기를 얻는데 비교적 정확하고 안전한 방법이라 생각된다.

  • PDF

종양 환자에서 초고에너지(511 keV) 조준기를 이용한 전신 F-18-FDG 평면 영상: Coincidence 감마카메라 단층 촬영 영상과의 비교 (F-18-FDG Whole Body Scan using Gamma Camera equipped with Ultra High Energy Collimator in Cancer Patients: Comparison with FDG Coincidence PET)

  • 배문선;박찬희;조철우;윤석남;양승대;임상무
    • 대한핵의학회지
    • /
    • 제33권1호
    • /
    • pp.65-75
    • /
    • 1999
  • 목적: 종양 환자의 평가에 있어서 초고에너지 조준기를 장착하여 511 keV에 적용시킨 감마카메라로 FDG 전신 평면 영상(FDG W/B scan)을 얻어 충분한 정보를 얻을 수 있는지 알아보고 동시에 같은 카메라로 동시계수 회로를 이용한 양전자 방출 단층촬영(FDG CoDe PET)을 실시하여 그 결과를 비교하였다. 대상 및 방법: F-18 FDG를 이용하여 초고에너지 조준기와 동시계수 양전자 방출영상에 대해 각각 팬텀 실험을 실시하였고, 악성종양이 의심되거나 진단된 환자 14명을 대상으로 FDG 전신 평면 영상과 양전자 방출 단층 영상을 얻어 방사선학적 검사, 임상적 추적관찰, 조직학적 검사 등과 비교하였다. 결과: 평면 영상에서는 해상력 13.1 mm, 민감도 2638 cpm/MBq/ml, 동시계수 영상에서는 공간 해상력 7.49 mm, 민감도 5351 cpm/MBq/ml로 측정되었다. FDG CoDe PET에서 14명의 환자 중 8명에서 FDG의 섭취가 있었다. 두 방법 모두에서 FDG 섭취가 없었던 병변은 모두 CT에서 1 cm 이하 였으나 한 예에서 2 cm 크기의 전이성 림프절을 찾지 못하였다. FDG 섭취를 보였던 병변은 모두 CT상 1.5cm 이상이거나 여러 개가 모여 있는 병변이었다. FDG W/B scan은 FDG CoDe PET와 거의 비슷한 결과를 보였으나 위음성과 위양성이 1예씩 더 있었다. FDG CoDe PET에서 보였던 다수의 폐 결절과 간 결절들이 FDG W/B scan에서 한 예를 제외하고는 모두 발견되었다. 결론: 감마카메라에 의한 FDG 영상들은 악성 종양의 감별, 병기 결정, 추적검사 등에 유용하게 쓰일 수 있을 것으로 간주되며, SPECT 카메라가 널리 보급되어 있으므로 FDG 전신 평면영상과 동시계수 양전자 방출영상은 서로 보완적으로 쓰이면서 FDG의 지역 분배 공급을 통해 기존의 PET를 대신하여 FDG를 이용한 더 많은 임상적 이용 및 영상진단을 가능하게 할 것이다.

  • PDF

폐암환자의 종양추적 정위방사선치료를 위한 삼차원 및 사차원 방사선치료계획의 비교 (Comparison of Three- and Four-dimensional Robotic Radiotherapy Treatment Plans for Lung Cancers)

  • 채규영;임영경;강기문;정배권;하인봉;박경범;정진명;김동욱
    • Radiation Oncology Journal
    • /
    • 제28권4호
    • /
    • pp.238-248
    • /
    • 2010
  • 목적: 폐암환자의 종양추적 정위방사선치료에서 삼차원 및 사차원치료계획의 선량분포 차이를 비교하였고 선량계산 알고리즘에 따른 폐의 비균질성 보정 결과에 커다란 차이가 있음을 확인하고자 하였다. 대상 및 방법: 7명의 폐암환자를 대상으로 전향적 호흡동조된 사차원 컴퓨터단층촬영 영상을 얻었다. 획득한 영상은 환자의 호흡에 대응하는 10개의 삼차원단층촬영 영상이며 이를 바탕으로 사차원치료계획이 수립되었다. 사차원 치료계획에서는 종양과 주변장기의 움직임을 고려하여 X선의 방향과 선량분포를 최적화한다. 사차원치료계획에서 최적화된 빔을 호흡의 50% 위상에 해당하는 한 개의 삼차원단층촬영 영상에 동일하게 적용하여 삼차원치료계획을 만들었다. 삼차원 및 사차원 치료계획에서 선량계산을 위하여 각각 Ray-tracing과 몬테칼로 알고리즘을 사용하였다. 수립된 4개의 치료계획에서 처방선량의 종양체적 포함률 종양체적의 95%를 포함하는 선량인 D95, 종양의 최대선량, 그리고 척수의 최대선량을 비교하였고 종양의 위치에 대한 연관성도 함께 고찰하였다. 결론: 몬테칼로 알고리즘을 사용한 삼차원 및 사차원 치료계획에서 종양이 폐의 하엽에 위치해 있는 경우에는 사차원치료계획에서 종양 포함률이 평균 4.4% 높았던 반면에 종양이 폐의 중엽이나 상엽에 위치해 있는 경우에는 반대로 평균 4.6% 낮았다 또한 D95도 종양이 폐의 하엽에 위치해 있는 경우에는 사차원치료계획에서 평균 4.8% 높았던 반면에 종양이 폐의 중엽이나 상엽에 위치해 있는 경우에는 반대로 평균 1.7% 낮았다. 척수의 최대선량에 대한 비교에서도 종양과 유사한 경향이 나타났다. 치료계획의 차원과 무관하게 Ray-tracing과 몬테칼로 알고리즘 사이의 선량계산 차이는 평균 30% 정도로 몬테칼로 알고리즘을 사용하였을 때 처방선량이 포함하는 종양의 부피는 크게 줄어들었다. 결론: 폐 종양의 삼차원 및 사차원 치료계획 사이의 차이를 종양과 척수의 선량분포를 통해 비교하였다. 두 치료계획 사이에서 planning target volume (PTV) 포함률이나 D95와 같이 종양과 관련된 선량학적 인자들의 차이 또는 척수의 최대선량 차이는 종양의 이동크기와 형태변화의 정도에 밀접하게 연관되어 있는 것으로 나타났다. 또한, 치료계획의 차원과 무관하게 몬테칼로 알고리즘을 사용하면 처방선량이 포함하는 PTV 포함률이나 D95가 크게 줄어드는 것을 확인하였다.

진행된 간세포암에서의 간문맥 혈전증에 대한 방사선치료 효과 (The Role of Radiotherapy in the Treatment of Portal Vein Thrombosis from Advanced Hepatocellular Carcinoma)

  • 김정훈;최은경;안승도;이상욱;신성수;최원식;임영석;김강모;서동진;정영화;이영상;원형진;김종훈
    • Radiation Oncology Journal
    • /
    • 제25권3호
    • /
    • pp.170-176
    • /
    • 2007
  • 목적: 치료방법이 정립되지 않은 진행된 간세포암에서의 간문맥 혈전증에 대한 방사선치료의 효과와 간독성을 측정함으로써 향후 방사선치료의 효용성에 대하여 알아보고자 한다. 대상 및 방법: 2000년 5월부터 2005년 12월까지 서울아산병원에서 원발성 간세포암으로 진단받은 환자 중 간문맥 혈전증이 동반된 70명의 환자를 대상으로 후향적 분석을 하였다. 대상 환자들의 나이는 $24{\sim}74$세(중앙값 51세)였으며, 대부분이 Child-Pugh's class A, B였고 Eastern Cooperative Oncology Group (ECOG) 2 이하였다. 방사선치료는 3차원입체조형치료를 시행하였으며, 1회 선량은 $2{\sim}4$ Gy로 총방사선량은 $40{\sim}60$ Gy (중앙값 48 Gy)였으며, 생물학적 유효선량(biologic effective dose)은 $31.3{\sim}78.0\;Gy_{10}$ (중앙값 61.6 $Gy_{10}$)였다. 결과: 치료 반응평가는 치료 전과 치료 종료 후 최소 1개월 이상 경과 후 컴퓨터 단층촬영(CT)을 시행하여 평가하였으며, 대상 환자들의 추적관찰기간은 $2{\sim}24$개월(중앙값 9개월)이었다. 방사선치료 후 완전반응인 경우가 2명(2.9%), 부분반응 31명(44.3%), 무반응 35명(50.0%), 진행병변 2명(2.9%)이었다. 1년 무진행 생존율(progression-free survival)은 60%였으며, 중앙 무진행 생존기간은 17개월이었다. 전체 환자의 중앙 생존기간(overall survival)은 11개월이었으며, 치료반응 유무에 따라 부분 반응 이상을 보인 환자군의 중앙 생존기간은 15개월, 무반응이거나 진행병변을 보인 환자군은 8개월로 통계학적 차이를 보였다(p=0.032). 치료 중 일시적인 간기능 저하가 4명(5.7%), 방사선 간염은 1명(1.4%)에서 발생하였다. 결론: 진행된 간세포암에서의 간문맥 혈전에 대해 방사선치료를 시행한 경우 비교적 유용하며 안전한 치료법이며, 앞으로의 연구에서는 방사선치료가 생존율을 향상시킬 수 있는지 여부와 적절한 방사선량을 결정하기 위한 연구가 필요할 것으로 생각된다.