Evaluation of beam delivery accuracy for Small sized lung SBRT in low density lung tissue (Small sized lung SBRT 치료시 폐 실질 조직에서의 계획선량 전달 정확성 평가)

  • Oh, Hye Gyung;Son, Sang Jun;Park, Jang Pil;Lee, Je Hee
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.31 no.1
    • /
    • pp.7-15
    • /
    • 2019
  • Purpose: The purpose of this study is to evaluate beam delivery accuracy for small sized lung SBRT through experiment. In order to assess the accuracy, Eclipse TPS(Treatment planning system) equipped Acuros XB and radiochromic film were used for the dose distribution. Comparing calculated and measured dose distribution, evaluated the margin for PTV(Planning target volume) in lung tissue. Materials and Methods : Acquiring CT images for Rando phantom, planned virtual target volume by size(diameter 2, 3, 4, 5 cm) in right lung. All plans were normalized to the target Volume=prescribed 95 % with 6MV FFF VMAT 2 Arc. To compare with calculated and measured dose distribution, film was inserted in rando phantom and irradiated in axial direction. The indexes of evaluation are percentage difference(%Diff) for absolute dose, RMSE(Root-mean-square-error) value for relative dose, coverage ratio and average dose in PTV. Results: The maximum difference at center point was -4.65 % in diameter 2 cm size. And the RMSE value between the calculated and measured off-axis dose distribution indicated that the measured dose distribution in diameter 2 cm was different from calculated and inaccurate compare to diameter 5 cm. In addition, Distance prescribed 95 % dose($D_{95}$) in diameter 2 cm was not covered in PTV and average dose value was lowest in all sizes. Conclusion: This study demonstrated that small sized PTV was not enough covered with prescribed dose in low density lung tissue. All indexes of experimental results in diameter 2 cm were much different from other sizes. It is showed that minimized PTV is not accurate and affects the results of radiation therapy. It is considered that extended margin at small PTV in low density lung tissue for enhancing target center dose is necessary and don't need to constraint Maximum dose in optimization.

Development of a Hospital Service-based Costing System and Its Application (병원서비스별 원가분석모형의 개발과 적용)

  • 박하영
    • Health Policy and Management
    • /
    • v.5 no.2
    • /
    • pp.35-69
    • /
    • 1995
  • The managerial environment of hospitals in Korea characterized by low levels of medical insurance fees is worsening by increasing government regulations as to the utilization of medical services, rising costs of labor, material, and medical equipments, growing patient expectations concerning the quality of services, and escalating competitions among large hospitals in the market. Hospitals should seek for their survival strategies in this harsh environment and they should have information about costs of their products in doing so. However, it has not been available due to the complexity of the production process of hospital services. The objectives of this study were to develop a service-based cost accounting model and to apply the developed model to a study hospital to obtain cost information of hospital services. A model commonly used for the job-order product cost accounting in the manufacturing industry was modified for the use in hospitals in Korea. Actual costs, instead of standard costs, incurred to produce a unit of services during a given period of time were estimated in the model. Data required to implement the model included financial information, statistics for the allocation of supportive cost center costs to final cost centers, statistics for the allocation of final cost center costs to services, and the volume of each services charged to patients during a study period. The model was executed using data of a university teaching hospital located in Seoul for the fiscal year 1992. Data for financial information, allocation statistics fo supportive service costs, and the volume of services, most of them in electronic form, were available to the study. Data for allocation statistics of final cost center costs were collected in the study. There were 15 types of evaluation and management service, 2, 923 types of technical service, and 2, 608 types of drug and material service charged to patients in the study hospital during the fiscal year 1992. Labor costs of each of seven types of pesonnel, material costs of 611 types of drugs and materials, and depreciation costs of 212 types of medical equipments, miscellaneous costs, and indirect costs incurred in producing a unit of each services were estimated. Medical insurance fees for basic services such as evaluation and management of inpatients and outpatients, injection, and filling prescriptions, and for operating procedures were found to be set lower than costs. Infrequent services which use expensive medical equipments showed negative revenuse as well. On the other hand, fees for services not covered by the insurance such as CT, MRI and Sonogram, and for laboratory tests were higher than costs. This study has a significance in making it possible for a hospital to obtain cost information for all types of services which produced income based on all types of expenses incurred during a given period of time. This information can assist the management of a hospital in finding an effective cost reduction strategy, an efficient service-mix strategy under a given fee structure, and an optimum strategy for within-hospital resource allocations.

  • PDF

A Study on Various Automatic Exposure Control System in Multi-Detector Computed Tomography by Using Human Phantom (인체 모형을 이용한 다중 검출기 컴퓨터단층촬영기기의 다양한 자동노출제어 시스템에 대한 연구)

  • Kim, Yong-Ok;Seoung, Youl-Hun
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.13 no.4
    • /
    • pp.1714-1720
    • /
    • 2012
  • The purpose of the study was to evaluation of the radiation dose reduction and the possibility of the maintainability of the adequate image quality using various automatic exposure control (AEC) systems in multi-detector computed tomography (MDCT). We used three AEC systems for the study: General Electric Healthcare (Auto-mA 3D), Philips Medical systems (DoseRight) and Siemens Medical Solutions (Care Dose 4D). The general scanning protocol was created for the each examination with the same scanning parameters as many as possible. In the various AEC systems, the evaluation of reduced-dose was evaluated by comparing to fixed mAs with using human phantom. The image quality of the phantom was evaluated with measuring the image noise (standard deviation) by insert regions of interests. Finally, when we applied to AEC for three manufacturers, the radiation dose reduction decreased each 35.3% in the Auto-mA 3D, 58.2% in the DoseRight, and 48.6% in the Care Dose 4D. And, there was not statistical significant difference among the image quality in the Strong/Weak of the Care Dose 4D(P=.269). This applies to variety of the AEC systems which will be very useful to reduce the dose and to maintain the high quality.

A Study on the Fabrication of the Sensor Module for the Detection of Resistive Leakage Current (Igr) in Real Time and Its Reliability Evaluation (실시간 Igr 검출을 위한 센서 모듈의 제작 및 신뢰성 평가에 관한 연구)

  • Lee, Byung-Seol;Choi, Chung-Seog
    • Journal of the Korean Society of Safety
    • /
    • v.33 no.1
    • /
    • pp.28-34
    • /
    • 2018
  • The purpose of this study is to fabricate a sensor module to detect the resistive leakage current (Igr) in real time that occurs to low voltage electric lines and to verify its reliability. In the case of the developed sensor module, wires are inserted into the zero current transformer (ZCT) and current transformer (CT) in advance and then the branch line is connected to the circuit breaker. The measurement result of the resistance of the distribution panel equipped with the developed sensor module shows that the resistance is $0.151m{\Omega}$ between the R and R phases, $0.169m{\Omega}$ between the S and S phases, and $0.178m{\Omega}$ between the T and T phases, respectively. The insulation resistance measured at AC 500 V and 1,000 V is $0.08m{\Omega}$ between the R, S, T and N phases, respectively. Then, the insulation resistance measured at DC 500 V is $83.3G{\Omega}$ between the R, S, T and G terminal, respectively. In addition, the applied withstanding voltage is AC 220 V/380 V/440 V and it was found that characteristics between all phases are good. This study measured the standby power by installing the developed sensor module at the rear of the MCCB and switching the circuit breaker on sequentially. The standby power is 1.350 W when one circuit breaker is turned on, 1.690 W when 2 circuit breakers are turned on, and 4.371 W when 10 circuit breakers are turned on. This study also verified the reliability of the standby power of the distribution panel equipped with the developed sensor module using the Minitab Program (Minitab PGM). Since the analysis shows the statistical average of 1.34627 in the reliable range of normal distribution, standard deviation of 0.001874, AD of 0.554, and P value of 0.140, it is found that the distribution panel equipped with the developed sensor module has high reliability.

Introduction of Hindfoot Coronal Alignment View (후족부 관상면 배열 영상에 대한 고안)

  • Moon, Il-Bong;Jeon, Ju-Seob;Yoon, Kang-Cheol;Choi, Nam-Kil;Kim, Seung-Kook
    • Journal of radiological science and technology
    • /
    • v.29 no.4
    • /
    • pp.225-228
    • /
    • 2006
  • Purpose: Accurate clinical evaluation of the alignment of the calcaneus relative to the tibia in the coronal plane is essential in the evaluation and treatment of hindfoot pathologic condition. Previously described standard anteroposterior, lateral, and oblique radiographic methods of the foot or ankle do not demonstrate alignment of the tibia relation to the calcaneus in the coronal plane. The purpose of this study was to introduce hindfoot coronal alignment view. Material : 1) Both feet were imaged simultaneously on an elevated, radiolucent foot stand equipment. 2) Both feet stood on a radiolucent platform with equal weight on both feet. 3) Both feet are located foot axis longitudinal perpendicular to the platform. 4) Silhouette tracing around both feet are made, and line is then drawn to bisect the silhouette of the second toe and the outline of the heel. 5) The x-ray beam is angled down approximately $15^{\circ} to $20^{\circ} Result : 1) This image described tibial axis and medial, lateral tuberosity of calcaneus. 2) Calcaneus do not rotated. 3) The view is showed by talotibial joint space. Conclusion: Although computed tomographic and magnetic resonance imaging techniques are capable of demonstrating coronal hindfoot alignment, they lack usefulness in most clinical situations because the foot is imaged in a non-weight bearing position. But hindfoot coronal alignment view is obtained for evaluating position changing of inversion, eversion of the hindfoot and varus, valgus deformity of calcaneus.

  • PDF

The Role of HRCT in the Follow-Up Evaluation of Diffuse Interstitial Pulmonary Fibrosis (미만성 간질성 폐섬유증의 경과 관찰에서의 고해상도 CT(HRCT)의 의의)

  • Kim, Hong-Kyu;Kwak, Seung-Min;Song, Koun-Sik;Lim, Chae-Man;Koh, Youn-Suck;Kim, Woo-Sung;Kim, Dong-Soon;Kim, Won-Dong
    • Tuberculosis and Respiratory Diseases
    • /
    • v.41 no.6
    • /
    • pp.597-603
    • /
    • 1994
  • Background: Because of the power of HRCT to detect the minute changes in lung parenchyme and the advantage of noninvasiveness, it may be the ideal method of follow-up evaluation of the patients with diffuse interstitial pulmonary fibrosis. So the aim of the study is to find out whether the change of HRCT during the course of the disease can represent the change in symptom and pulmonary function test. Method: Thirteen patients with diagnosis of diffuse interstitial pulmonary fibrosis who had more than two times of HRCT during the course of disease were studied. The extent of the disease in HRCT was measured at three levels using image analyzer. The ralationship between the percent change in the disease extent in HRCT, symptom score, and pulmonary function tests were analysed. Results: The change of disease extent in HRCT has good correlation with the change in dyspnea and diffusion capacity(r=0.716, p=0.0012). But there was no correlation between the change of HRCT and FVC or TLC. Also significant inverse correlation was noted between the change in dyspnea and diffusion capacity(r=-0.707, p=0.0047). Conclusion: These data suggest that HRCT may be a good method of follow-up in diffuse interstitial pulmonary fibrosis.

  • PDF

Development and Evaluation of Quality Assurance Worksheet for the Radiation Treatment Planning System (방사선치료계획 시스템의 정도관리 절차서 개발 및 유용성 평가)

  • Cho Kwang Hwan;Choi Jinho;Shin Dong Oh;Kwon Soo Il;Choi Doo Ho;Kim Yong Ho;Lee Sang Hoon
    • Progress in Medical Physics
    • /
    • v.15 no.4
    • /
    • pp.186-191
    • /
    • 2004
  • The periodic Quality Assurance (QA) of each radiation treatment related equipments is important one, but quality assurance of the radiation treatment planning system (RTPS) is still not sufficient rather than other related equipments in clinics. Therefore, this study will present and test the periodic QA program to compare, evaluation the efficiency of the treatment planning systems. This QA program is divided to terms for the input, output devices and dosimetric data and categorized to the weekly, monthly, yearly and non-periodically with respect to the job time, frequency of error, priority of importance. CT images of the water equivalent solid phantom with a heterogeneity condition are input into the RTPS to proceed the test. The actual measurement data are obtained by using the ion chamber for the 6 MV, 10 MV photon beam, then compared a calculation data with a measurement data to evaluate the accuracy of the RTPS. Most of results for the accuracy of geometry and beam data are agreed within the error criteria which is recommended from the various advanced country and related societies. This result can be applied to the periodic QA program to improve the treatment outcome as a proper model in Korea and used to evaluate the accuracy of the RTPS.

  • PDF

Use of Flattening Filter Free Photon Beams for Off-axis Targets in Conformal Arc Stereotactic Body Radiation Therapy

  • Smith, Ashley;Kim, Siyong;Serago, Christopher;Hintenlang, Kathleen;Ko, Stephen;Vallow, Laura;Peterson, Jennifer;Hintenlang, David;Heckman, Michael;Buskirk, Steven
    • Progress in Medical Physics
    • /
    • v.25 no.4
    • /
    • pp.288-297
    • /
    • 2014
  • Dynamic conformal arc therapy (DCAT) and flattening-filter-free (FFF) beams are commonly adopted for efficient conformal dose delivery in stereotactic body radiation therapy (SBRT). Off-axis geometry (OAG) may be necessary to obtain full gantry rotation without collision, which has been shown to be beneficial for peripheral targets using flattened beams. In this study dose distributions in OAG using FFF were evaluated and the effect of mechanical rotation induced uncertainty was investigated. For the lateral target, OAG evaluation, sphere targets (2, 4, and 6 cm diameter) were placed at three locations (central axis, 3 cm off-axis, and 6 cm off-axis) in a representative patient CT set. For each target, DCAT plans under the same objective were obtained for 6X, 6FFF, 10X, and 10FFF. The parameters used to evaluate the quality of the plans were homogeneity index (HI), conformality indices (CI), and beam on time (BOT). Next, the mechanical rotation induced uncertainty was evaluated using five SBRT patient plans that were randomly selected from a group of patients with laterally located tumors. For each of the five cases, a plan was generated using OAG and CAG with the same prescription and coverage. Each was replanned to account for one degree collimator/couch rotation errors during delivery. Prescription isodose coverage, CI, and lung dose were evaluated. HI and CI values for the lateral target, OAG evaluation were similar for flattened and unflattened beams; however, 6FFF provided slightly better values than 10FFF in OAG. For all plans the HI and CI were acceptable with the maximum difference between flattened and unflattend beams being 0.1. FFF beams showed better conformality than flattened beams for low doses and small targets. Variation due to rotational error for isodose coverage, CI, and lung dose was generally smaller for CAG compared to OAG, with some of these comparisons reaching statistical significance. However, the variations in dose distributions for either treatment technique were small and may not be clinically significant. FFF beams showed acceptable dose distributions in OAG. Although 10FFF provides more dramatic BOT reduction, it generally provides less favorable dosimetric indices compared to 6FFF in OAG. Mechanical uncertainty in collimator and couch rotation had an increased effect for OAG compared to CAG; however, the variations in dose distributions for either treatment technique were minimal.

Pre-operative Concurrent Chemoradiotherapy for Stage IlIA (N2) Non-Small Cell Lung Cancer (N2 병기 비소세포 폐암의 수술 전 동시화학방사선요법)

  • Lee, Kyu-Chan;Ahn, Yong-Chan;Park, Keunchil;Kim, Kwhan-Mien;Kim, Jhin-Gook;Shim, Young-Mog;Lim, Do-Hoon;Kim, Moon-Kyung;Shin, Kyung-Hwan;Kim, Dae-Yong;Huh, Seung-Jae;Rhee, Chong-Heon;Lee, Kyung-Soo
    • Radiation Oncology Journal
    • /
    • v.17 no.2
    • /
    • pp.100-107
    • /
    • 1999
  • Purpose: This is to evaluate the acute complication, resection rate, and tumor down-staging after pre-operative concurrent chemoradiotherapy for stage IIIA (N2) non-small cell lung cancer. Materials and Methods Fifteen patients with non-small cell lung cancer were enrolled in this study from May 1997 to June 1998 in Samsung Medical Center. The median age of the patients was 61 (range, 45~67) years and male to female ratio was 12:3. Pathologic types were squamous cell carcinoma (11) and adenocarcinoma (4). Pre-operative clinical tumor stages were cT1 in 2 patients, cT2 in T2, and cT3 in 1 and all were N2. Ten patients were proved to be N2 with mediastinoscopic biopsy and five had clinically evident mediastinal Iymph node metastases on the chest CT scans. Pre-operative radiation therapy field included the primary tumor, the ipsilateral hilum, and the mediastinum. Total radiation dose was 45 Gy over 5 weeks with daily dose of 1.8 Gy. Pre-operative concurrent chemotherapy consisted of two cycles of intravenous cis-Platin (100 mg/m$^{2}$) on day 1 and oral Etoposide (50 mg/m$^{2}$/day) on days 1 through 14 with 4 weeks' interval. Surgery was followed after the pre-operative re-evaluation including chest CT scan in 3 weeks of the completion of the concurrent chemoradiotherapy if there was no evidence of disease progression. Results : Full dose radiation therapy was administered to all the 15 patients. Planned two cycles of chemotherapy was completed in 11 patients and one cycle was given to four. One treatment related death of acute respiratory distress syndrome occurred In 15 days of surgery. Hospital admission was required in three patients including one with radiation pneumonitis and two with neutropenic fever. Hematologic complications and other acute complications including esophagitis were tolerable. Resection rate was 92.3% (12/l3) in 13 patients excluding two patients who refused surgery. Pleural seeding was found in one patient after thoracotomy and tumor resection was not feasible. Post-operative tumor stagings were pT0 in 3 patients, pTl in 6, and pT2 in 3. Lymph node status findings were pN0 in 8 patients, pN1 in 1, and pN2 in 3. Pathologic tumor down-staging was 61.5% (8/13) including complete response in three patients ($23.7%). Tumor stage was unchanged in four patients (30.8%) and progression was in one (7.7%). Conclusions : Pre-operative concurrent chemoradiotherapy for Stage IIIA (N2) non-small cell lung cancer demonstrated satisfactory results with no increased severe acute complications. This treatment shceme deserves more patinet accrual with long-term follow-up.

  • PDF

Diffuse Panbronchiolitis : Clinical Significance of High-resolution CT and Radioaerosol Scan Manifestations (미만성 범세기관지염에서 흉부 고해상도 전산화 단층촬영의 임상적의의 및 폐환기주사 소견)

  • Song, So Hyang;Kim, Hui Jung;Kim, Young Kyoon;Moon, Hwa Sik;Song, Jeong Sup;Park, Sung Hak;Kim, Hak Hee;Chung, Soo Kyo
    • Tuberculosis and Respiratory Diseases
    • /
    • v.44 no.1
    • /
    • pp.124-135
    • /
    • 1997
  • Background : Diffuse panbronchiolitis(DPB) is a disease characterized clinically by chronic cough, expectoration and dyspnea; and histologically by chronic inflammation localized mainly in the region of the respiratory bronchiole. It is prevalent in Japanese, but is known to be rare in Americans and Europians. Only a few cases in Chinese, Italians, North Americans and Koreans have been reported. It is diagnosed by characteristic clinical, radiological and pathologic features. High-resolution CT(HRCT) is known to be valuable in the study of the disease process and response to therapy in DPB. To our knowledge, there has been no correlation of its appearance on HRCT with the severity of the disease process, and radioaerosol scan(RAS) of the lung has not previously been used for the diagnosis of DPB. Method : During recent two years we have found 12 cases of DPB in Kangnam St. Mary's Hospital, Catholic University Medical College. We analysed the clinical characteristics, compared HRCT classifications with clinical stages of DPB, and determined characteristic RAS manifestations of DPB. Results : 1. The ages ranged from 31 to 83 years old(mean 54.5 years old), and male female ratio was 4:8. 75%(9/12) of patients had paranasal sinusitis, and only one patient was a smoker. 2. The patients were assigned to one of three clinical stages of DPB on the basis of clinical findings, sputum bacterology and arterial blood gas analysis. of 12 cases, 5 were in the first stage, 4 were in the second stage, and 3 were in the third stage. In most of the patients, pulmonary function tests showed marked obstructive and slight restrictive impairments. Sputum culture yielded P.aeruginosa in 3 cases of our 12 cases, K.pneumoniae in 2 cases, H.influenzae in 2 cases, and S.aureus in 2 cases. 3. Of 12 patients, none had stage I characteristics as classified on HRCT scans, 4 had slage II findings, 5 had stage III findings, and 3 had stage IV characteristics. 4. We peformed RAS in 7 of 12 patients With DPB. In 71.4% (5/7) of the patients, RAS showed mottled aerosol deposits characteristically in the transitional and intermediary airways with peripheral airspace defects, which contrasted sharply with central aerosol deposition of COPD. 5. There were significant correlations between HRCT stages and clinical stages(r= 0.614, P < 0.05), between HRCT types and Pa02(r= -0.614, P < 0.05), and between HRCT types and ESR(r= 0.618, P < 0.01). Conclusion : The HRCT classifications correspond well to the clinical stage. Therfore in the examination of patients with DPB, HRCT is useful in the evaluation of both the location and severity of the lesions. Also, RAS apears to be a convenient, noninvasive and useful diagnostic method of DPB.

  • PDF