• Title/Summary/Keyword: CT Value

Search Result 978, Processing Time 0.027 seconds

The Method of Improvement by Illuminance Measurement of the CT Scan Room in a General Hospital Radiology (종합병원 영상의학과 CT 검사실의 조도 측정에 의한 향상 방안)

  • Kweon, Dae-Cheol;Yang, Sung-Hwan;Kang, Young-Sig
    • Journal of the Korean Institute of Plant Engineering
    • /
    • v.23 no.4
    • /
    • pp.51-56
    • /
    • 2018
  • Computed tomography (CT) scan room in the department of radiology is very necessary to maintain pleasant and proper illuminance to relieve fatigue and inconvenience because it affects the work environment to the radiologist. Accordingly, this paper describes the method for measurement of illuminance that exposed to an environmental elements in a CT scan room of the hospital. Therefore, the purpose of this paper is to propose an optimal environment of CT scan room based on the measurement of illuminance. In addition, the 5 point method by KS C7612 was applied to measure the illuminance with illuminometer (Unfors xi light probe) in the CT scan room. In result of this paper, minimum value and maximum value of illuminance in the CT scan room was measured 212.7 lux and 354.8 lux, respectively. The illuminance of CT scan room was lower than KS A 3011. Finally, the work environment in CT scan room should provide higher illuminance for the comfortable environment of radiologists and patients.

Is FDG -PET-CT A Valuable Tool in Prediction of Persistent Disease in Head and Neck Cancer

  • Uzel, Esengul Kocak;Ekmekcioglu, Ozgul;Elicin, Olgun;Halac, Metin;Uzel, Omer Erol
    • Asian Pacific Journal of Cancer Prevention
    • /
    • v.14 no.8
    • /
    • pp.4847-4851
    • /
    • 2013
  • Objectives: To evaluate accuracy of FDG-PET CT in prediction of persistent disease in head and neck cancer cases and to determine prognostic value of metabolic tumor response. Materials and Methods: Between 2009 and 2011, 46 patients with squamous cell carcinoma of head and neck receiving PET-CT were treated with definitive radiotherapy, with or without chemotherapy. There were 29 nasopharyngeal, 11 hypopharyngeal, 3 oropharyngeal and 3 laryngeal cancer patients, with a median age of 50.5 years (range 16-84), 32 males and 14 females. All patients were evaluated with PET-CT median 3-5 months (2.4-9.4) after completion of radiotherapy. Results: After a median 20 months of follow up, complete metabolic response was observed in 63% of patients. Suspicious residual uptake was present in 10.9% and residual metabolic uptake in 26.0% of patients. The overall sensitivity, specificity, positive predictive value and negative predictive value of FDG-PET-CT for detection of residual disease was 91% and 81%, 64% and 96% respectively. Two year LRC was 95% in complete responders while it was 34% in non-complete responders. Conclusions: FDG PET CT is a valuable tool for assessment of treatment response, especially in patients at high risk of local recurrence, and also as an indicator of prognosis. Definitely more precise criteria are required for assessment of response, there being no clear cut uptake value indicating residual disease. Futhermore, repair processes of normal tissue may consume glucose which appear as increased uptake in control FDG PET CT.

USEFULNESS OF $^{18}F$-FDG PET/CT IN THE EVALUATION OF CERVICAL LYMPH NODE METASTASIS IN PATIENTS WITH ORAL CANCER (구강암 환자에서 $^{18}F$ FDG-PET/CT의 경부 림프절 전이 평가 유용성)

  • Yu, Min-Gi;Ryu, Sun-Youl
    • Journal of the Korean Association of Oral and Maxillofacial Surgeons
    • /
    • v.35 no.4
    • /
    • pp.213-220
    • /
    • 2009
  • Purpose: The present study was aimed to examine the usefulness of 18F-FDG PET/CT in the evaluation of cervical lymph node metastasis in patients with oral cancer. Materials and methods: Twenty-two patients who underwent neck dissection to treat oral cancer were subjected for examination. The cervical node metastasis was evaluated by means of clinical examination, CT scan, PET, and histologic examination. By comparing the results of each examination modality with those of histologic examination, it's sensitivity, specificity, positive predictive value, and negative predictive value were determined. Results: The oral cancer was more frequent in males with a ratio of 2.14:1. The sixth decade showed the highest incidence in age distribution with mean of $56{\pm}16$. Histologic findings showed that squamous cell carcinoma was the most common (15 patients), and mucoepidermoid carcinoma (3), malignant melanoma (2), and adenoid cystic carcinoma and ghost cell odontogenic carcinoma (1 each), in order. In most cases, wide surgical excision of the primary cancer and neck dissection was performed, followed by reconstruction with free flaps when necessary. When comparing the results of each examination modality with those of the histologic examination, clinical examination showed sensitivity, specificity, positive predictive value, and negative predictive value at 11%, 85%, 33%, and 58%, respectively. CT scans showed at 67%, 77%, 67%, and 77%, while $^{18}F$-FDG PET/CT at 78%, 77%, 70%, and 83%, respectively. Conclusions: These results suggest that PET is more useful, compared with clinical examination and CT scans, in the evaluation of cervical lymph node metastasis in patients with oral cancer.

Study on the Difference of Standardized Uptake Value in Fusion Image of Nuclear Medicine (핵의학 융합영상의 표준섭취계수 차이에 관한 연구)

  • Kim, Jung-Soo;Park, Chan-Rok
    • Journal of radiological science and technology
    • /
    • v.41 no.6
    • /
    • pp.553-560
    • /
    • 2018
  • PET-CT and PET-MRI which integrates CT using ionized radiation and MRI using phenomena of magnetic resonance are determined to have the limitation to apply the semi-quantitative index, standardized uptake value (SUV), with the same level due to the fundamental differences of image capturing principle and reorganization, hence, their correlations were analyzed to provide their clinical information. To 30 study subjects maintaining pre-treatment, $^{18}F-FDG$ (5.18 MBq/㎏) was injected and they were scanned continuously without delaying time using $Biograph^{TM}$ mMR 3T (Siemens, Munich) and Biograph mCT 64 (Siemens, Germany), which is an integral type, under the optimized condition except the structural differences of both scanners. Upon the measurement results of $SUV_{max}$ setting volume region of interest with evenly distributed radioactive pharmaceuticals by captured images, $SUV_{max}$ mean values of PET-CT and PET-MRI were $2.94{\pm}0.55$ and $2.45{\pm}0.52$, respectively, and the value of PET-MRI was measured lower by $-20.85{\pm}7.26%$ than that of PET-CT. Also, there was a statistically significant difference in SUVs between two scanners (P<0.001), hence, SUV of PET-CT and PET-MRI cannot express the clinical meanings in the same level. Therefore, in case of the patients who undergo cross follow-up tests with PET-CT and PET-MRI, diagnostic information should be analyzed considering the conditions of SUV differences in both scanners.

Assessment of Image Quality of Dual Energy 256 MDCT Technique Focused on keV Changes for MCA Stroke in Cerebral Angiography : Single Energy CT Standard Reference Mode (뇌혈관 조영 검사 시 중대뇌동맥 뇌졸중에 대한 keV 변화를 중심으로 이중 에너지 256 MDCT 기법의 영상의 질 평가 : 단일에너지 CT 표준방식)

  • Goo, Eun-Hoe
    • Journal of the Korean Society of Radiology
    • /
    • v.13 no.7
    • /
    • pp.961-968
    • /
    • 2019
  • The purpose of this study was to evaluate the usefulness of cerebral angiography in each energy level by using dual energy technique in CT. Methods were performed on 15 DE images and SE images of CT angiography. For the analysis of images, mean value, standard deviation, SNR and CNR value were determined by setting ROI on MCA, brain parenchyma tissue, and back ground. As a result of concurrent visual evaluation with Likert 5 point scale, the clearest MCA image was confirmed at DE 40 keV and SE 120 kVp(p>0.05). The SNR value of the SE image was measured to be similar to the 40 keV energy level of the DE image. The low energy level image of 40 keV and 50 keV was measured with a high SNR and the contrast ratio was higher than that of the high energy image.

Study on Methods to Improve Image Quality of Abdominal CT Images (복부 CT 영상의 화질 개선 방법에 대한 연구)

  • Seok-Yoon Choi
    • Journal of the Korean Society of Radiology
    • /
    • v.17 no.5
    • /
    • pp.717-723
    • /
    • 2023
  • Liver disease is highly associated with death, and other abdominal diseases are also important causes affecting a person's lifespan, and a CT scan is essential when treating abdominal diseases. High radiation exposure is essential to create images that are good for reading, but managing the patient's radiation exposure is also essential. In this study, a post-processing wavelet algorithm was proposed to improve the image quality of abdominal CT images. Wavelets have the disadvantage of having to set a threshold value depending on the type of input image. Therefore, we experimentally proposed the threshold value of the wavelet and evaluated whether the image quality was effective. As a result of the experiment, the optimal threshold value for abdominal CT images was calculated to be 50. In the case of image 1, noise was improved by 49% and in the case of image 2, by 29%, and the contrast also increased. if the results of this study are applied for post-processing after abdominal CT, image quality can be improved and it will be helpful in disease diagnosis.

Usefulness of Dual Energy CT to Improve Image Quality Degradation due to Lens Shielding (수정체 차페로 기인한 화질저하 개선을 위한 듀얼 에너지 CT의 유용성)

  • Yoon, Joon;Kim, Hyeonju
    • Journal of the Korean Society of Radiology
    • /
    • v.13 no.7
    • /
    • pp.969-977
    • /
    • 2019
  • Applying the bismuth shield used to reduce the radiation exposure, image quality may be reduced due to beam hardening caused by the shield during CT scan. Therefore, we tried to find out the energy range that can reduce image degradation by applying GSI mode of G company's dual energy CT and examine the possibility through experiment. As a result, after bismuth shielding, 118 ± 10.6 HU and 50.1 ± 14.6 HU at 50 keV after dual-energy CT scan were the most similar to the CT value before image deterioration(p> 0.05). It was measured 176.6 ± 7.1 and 138.3 ± 1.1 at 50 keV(p> 0.05). Experiments showed that the use of the shield during CT inspection inevitably degrades the image quality, but experiments show that the GSI function of the dual energy CT can maintain the image quality even when the shield is used. If the various shields are secured after the evaluation using the dual energy CT, it is expected to overcome the disadvantages of poor image quality caused by the use of the radiation shield for reducing the exposure, which is the biggest disadvantage of the CT scan.

Derivation of the Effective Energy Calculation Formula of the X-ray Beam Generated by the CT Simulator (CT 모의치료장치에서 발생된 X-선 빔의 유효에너지 계산식 유도)

  • Kim, Jong-Eon;Lee, Sang-Hun
    • Journal of the Korean Society of Radiology
    • /
    • v.15 no.6
    • /
    • pp.869-875
    • /
    • 2021
  • The purpose of this study is to derive a formula for calculating the effective energy of an X-ray beam generated by a CT simulator. Under 90, 120, and 140 kVp X-ray beams, the CT number calibration insert part of the AAPM CT performance phantom was scanned 5 times with a CT simulator. The CT numbers of polyethylene, polystyrene, water, nylon, polycarbonate, and acrylic were measured for each CT slice image. The average value of CT number measured under a single tube voltage and the linear attenuation coefficients corresponding to each photon energy calculated from the data of the National Institute of Standards and Technology were linearly fitted. Among the obtained correlation coefficients, the photon energy having the maximum value was determined as the effective energy. In this way, the effective energy of the X-ray beam generated at each tube voltage was determined. By linearly fitting the determined effective energies(y) and tube voltages(x), y=0.33026x+30.80263 as an effective energy calculation formula was induced.

Analysis on Early Detection of Lung Cancer by PET/CT Scan

  • Wang, Huo-Qiang;Zhao, Long;Zhao, Juan;Wang, Qiang
    • Asian Pacific Journal of Cancer Prevention
    • /
    • v.16 no.6
    • /
    • pp.2215-2217
    • /
    • 2015
  • Background: This systemic analysis was conducted to to evaluate the application value of positron emission tomography/computed tomography (PET/CT) in early diagnosis of lung cancer. Methods: Clinical studies evaluating the application value of PET/CT for patients underwent PET/CT imaging. The histological diagnosis served as the standard of truth. Results: Four clinical studies which including 1330 patients with pulmonary spaceoccupying lesions were considered eligible for inclusion. Systemic analysis suggested that, in all 1330 patients, pooled sensitivity was 98.7% (1313.2/1330) and specificity was 58.2%(276.85/476). Conclusion: This systemic analysis suggests that integrated PET/CT imaging provides high sensitivity, and reasonably high specificity, and could be applied for early diagnosis of lung cancer.

The Value of Calcium-scoring CT for Ischemic Cardiovascular Disease Screening (허혈성 심혈관 질환 선별을 위한 Calcium-scoring CT의 유용성)

  • Oh, Jung-Hoan;An, Sung-Min
    • Journal of radiological science and technology
    • /
    • v.32 no.1
    • /
    • pp.69-78
    • /
    • 2009
  • The cardiovascular disease has been known as a common cause of death for a long time in the west. The eating habits of Asia, including Korea, have changed recently, so that this disease is also a problem in Asia now. Annual Report on the Cause of Death Statistics from 1996 to 2006 reported that the cardiovascular disease would become the number one cause of death in the next $5{\sim}10$ years. Therefore we realize that more accurate examination is required. The aim of this study was to investigate the accuracy of Calcium-scoring CT and the relationship between risk factor and quantitative scores of Calcium-scoring CT. Through this study we expect that the national public health will be improved. Seventy patients with chest pain were chosen at random. The patients were undergone both coronary CT antigraphy and Calcium - scoring CT at G hospital in Incheon from February 1 to June 30, 2008. The result of the Calcium-scoring CT showed its usefulness for Ischemic cardiovascular disease, with an accuracy similar to that of exercise/pharmacologic stress or ECG when it is difficult for a patient to exercise due to joint problems, aging or for other reasons.

  • PDF