Delayed Contrast-enhanced Computed Tomography for Adrenal Masses in 3 Dogs (개 부신종양의 지연형 조영증강 전산화단층촬영 적용 3증례)

  • Lee, Jeo-soon;Yoon, Junghee;Oh, Hyun-jung;Kim, Bo-eun;Kim, Wan-hee;Youn, Hwa-young;Choi, Min-cheol
    • Journal of Veterinary Clinics
    • /
    • v.32 no.3
    • /
    • pp.263-267
    • /
    • 2015
  • Three dogs having adrenal masses detected on ultrasonographic examination were underwent computed tomography (CT) for surgery. After adrenalectomy, each mass was diagnosed pheochromocytoma with myelolipoma, adrenocortical carcinoma and adrenal adenoma through histopathology. Five minutes were used to get delayed enhanced CT images. Attenuation value was measured in each mass and the absolute and relative percentage of enhancement washout were calculated.

The Influence of Heart Rate and Coronary Calcification on the Diagnostic Accuracy of 64-slice Multidetector Cardiac CT in Coronary Artery Disease (심박동수 및 관상동맥 석회화가 64 절편 다중검출기 심장 CT의 관상동맥 질환 진단일치도에 미치는 영향)

  • Kang, Yeong-Han;Park, Jong-Sam
    • The Journal of the Korea Contents Association
    • /
    • v.9 no.12
    • /
    • pp.339-347
    • /
    • 2009
  • Purpose : This study was to investigate the influence of heart rate and coronary calcification on diagnostic accuracy of 64-slice multidetector CT(MDCT) in coronary artery disease. Methods : 178 patients(84 men, 94 women) undergoing cardiac CT were included in this study. 3 coronary arteries(LAD, LCX, RCA) were assessed the presence of significant stenosis($\geq50%$) and the results compared with those of coronary angiography. Results : On a patient-based analysis, the diagnostic accuracy of 64-slice MDCT was 96.6%. The diagnostic accuracy on left anterior descending, left circumflex, right coronary artery were 86.5%, 84.3%, 92.1% respectively. Body mass index and blood pressure were not influenced on diagnostic accuracy of 64-slice MDCT. In less than 60/min of heart rate, accuracy was 90.1% and $\kappa$ value was 0.78. While in more than 70/min of heart rate, accuracy was 75.8% and $\kappa$ value was 0.52. In less than 100 of coronary calcification, accuracy was 91.3% and $\kappa$ value was 0.81. While in more than 400, accuracy was 68.6% and $\kappa$ value was 0.33. Conclusion : 64-slice MDCT shows similar diagnostic accuracy as coronary angiography. But in the context of more than 70/min of heart rate and 400 of coronary calcification, diagnostic accuracy was decreased. So there needs to identify heart rate and coronary calcification in cardiac CT, and if heart rate shows more than 70/min, use beta-blocker to regulate it.

Extravasation Injury of Contrast Media in the Neck and Thorax During MDCT Scanning with 3D Image Reformation Findings (CT검사에서 조영제의 혈관외유출에 의한 목 및 흉부 손상의 3차원 재구성 영상)

  • Kweon, Dae-Cheol;Jang, Keun-Jo;Yoo, Beong-Gyu;Lee, Jong-Seok
    • Journal of radiological science and technology
    • /
    • v.30 no.3
    • /
    • pp.281-287
    • /
    • 2007
  • Contrast media may cause tissue injury by extravasation during intravenous automated injection during CT examination. Here, we present a study in which contrast media extravasation was detected and localized in the neck and thorax by three-dimensional(3D) CT data reformation. The CT studies of the extavasation site were performed using a 3D software program with four different display techniques axial, multi planar reformation(MPR), maximum intensity projection(MIP), and volume rendering displays are currently available for reconstructing MDCT data. 3D image reconstructions provide accurate views of high-resolution imaging. This paper introduces extravasation with the MDCT and 3D reformation findings of contrast media extravasation in neck ant thorax. The followed injection of the external jugular vein into an existing intravenous catheter and a large volume of extravasation was demonstrated on by 3D MDCT.

  • PDF

The Effectiveness of CT and MRI Contrast Agent for SUV in 18F-FDG PET/CT Scanning (18F-FDG PET/CT 검사에서 정량분석에 관한 CT와 MRI 조영제의 효과)

  • Cha, Sangyoung;Cho, Yonggwi;Lee, Yongki;Song, Jongnam;Choi, Namgil
    • Journal of the Korean Society of Radiology
    • /
    • v.10 no.4
    • /
    • pp.255-261
    • /
    • 2016
  • In this study, among various factors having influence on SUV, we intended to compare and analyze the change of SUV using CT(4 type) and MRI(3 type) contrast agents which are commercialized now. We used Discovery 690 PET/CT(GE) and NEMA NU2 - 1994 PET phantom as experimental equipment. We have conducted a study as follows; first, we filled distilled water to phantom about two-thirds and injected radioisotope(18F-FDG 37 MBq), contrast agent. Second, we mixed CT contrast agent with distilled water and MRI contrast agent with that water separately. And then, we stirred the fluid and filled distilled water fully not to make air bubble. In emission scan, we had 15minutes scanning time after 40 minutes mixing contrast agent with distilled water. In transmission scan, we used CT scanning and its measurement conditions were tube voltage 120 kVp, tube current 40 mA, rotation time 0.5 sec, slice thickness 3.27 mm, DFOV 30 cm. Analyzing results, we set up some ROIs in 10th, 15th, 20th, 25th, 30th slice and measured SUVmean, SUVmax. Consequently, all images mixed 3 types of MRI contrast agent with distilled water have high SUVmean as compared with pure FDG image but there was no statistical significance. In SUVmax, they have high score and there was statistical significance. And other 4 images mixed 4 types of CT contrast agent with distilled water have significance in both SUVmean and SUVmax. Attenuation correction in PET/CT has been executed through various methods to make high quality image. But we figured out that using CT and MRI contrast agents before PET/CT scanning could make distortion of image and decrease diagnostic value. In that reason, we have to sort out the priority of examination in hospital not to disturb other examination's results. Through this process, we will be able to give superior medical service to our customers.

A Study on the Reduction of Patient's Exposure Dose according to the Arrival Time of Contrast Media in Abdominal CT Scan using Bolus Tracking Technique (Bolus tracking 기법을 이용한 복부 CT 검사 시 조영제 도달시간에 따른 환자 피폭선량 감소에 관한 연구)

  • Lee, Seung yong;Han, Dong kyoon
    • Journal of the Korean Society of Radiology
    • /
    • v.15 no.2
    • /
    • pp.93-100
    • /
    • 2021
  • The purpose of this study is to find out the factors that affect the patient's exposure dose during the abdominal CT scan using the bolus tracking technique, and reducing the radiation exposure to the patient during the abdominal CT scan using the bolus tracking technique by adjusting the delay time according to the corresponding factor. The experiment was divided into two parts, and the first experiment was conducted with 300 patients There were 188 males and 112 females, and their average age was 58±12.18(19~85). In the second experiment, 150 subjects (100 males and 50 females) who were undergoing their follow-up examination among the first experiment subjects, and the difference in dose before and after was compared by applying the delay time according to the influencing factor. As a result of the first experiment, there was a relationship between the arrival time of the contrast media and the heart rate, and it was found that the arrival time decreased as the heart rate increased for both men and women. As a result of the second experiment, the average dose of CTDIvol and DLP before/after applying the delay time according to the heart rate decreased 4.98 mGy and 5.33 mGy·cm in the male group, and 3.54 mGy and 3.88 mGy·cm in the female group. By applying proper delay time according to the patient's heart rate during abdominal CT scan with the bolus tracking technique, the radiation exposure dose of the patient can be reduced.

The Development of Extravasation Detection Accessory System for the Preventive Contrast Media Extravasation in the Computed Tomography: A Preliminary Report (CT 검사에서 조영제의 혈관외유출 예방을 위한 EDA 시스템 개발의 예비 보고)

  • Kweon Dae-Cheol;Jeong Seok-Hee;Kim Tae-Hyung;Kim Jeong-Goo;Park Peom
    • Progress in Medical Physics
    • /
    • v.17 no.1
    • /
    • pp.32-39
    • /
    • 2006
  • To assess the ability of an extravasation detection accessory (EDA) system to detect clinically important extravascular injection of iodinated contrast material delivered with an automated power injector. Fifty patients referred for contrast material enhanced body computed tomography studied in a prospective, observation study in which the EDA system was used to identify and interrupt any injection associated with clinically Important extravasation. The presence or absence of extravasation was definitively established with multi-detector CT at the injection site (injection rate, $2.0{\sim}2.5$ mL/sec). There were two true positive, extravasation volumes $22{\sim}25$ mL. The EDA system had sensitivity in the detection of clinically important extravasation. The EDA system is easy to use, safe, and accurate In the monitoring of intravenous injections for extravasation, which may prove especially useful in CT applications.

  • PDF

Radiation dose and Lifetime Attributable Risk of Cancer Estimates in 64-slice Multidetector Computed Tomography (64-절편 다행검출 CT 검사에서의 환자선량과 암 발생의 Lifetime Attributable Risk(LAR) 평가)

  • Kang, Yeong-Han;Park, Jong-Sam
    • The Journal of the Korea Contents Association
    • /
    • v.11 no.4
    • /
    • pp.244-252
    • /
    • 2011
  • This study was to estimate the radiation dose associated with 64-slice multidetector CT(MDCT) in clinical practice and quantify the potential cancer risk associated with these examinations. Lifetime attributable risks(LAR) were estimated with models developed in the national Academies' Biological Effects of Ionizing Radiation VII report. Mean effective dose were 1.48mSv in Brain axial scan, 7.66mSv in chest routine contrast, 12.17mSv in coronary angiogram, 24.52mSv in Dynamic abdomen scan. LAR estimates for brain routine varied from 1 in 7463 for man to 1 in 4926 for women. In chest routine with contrast, LAR varied from 1 in 1449 for men to 1 in 952. LAR of Abdomen dynamic CT varied from 1 in 453 for men to 1 in 298 for women. So, 64-slice MDCT scan is associated with non-negligible LAR of cancer. Doses can be reduced by careful attention to scanning protocol.

Evaluation of the Low Tube Voltage in the Computed Tomography Scan Technique using a Low Concentration Contrast Agent (저농도 조영제를 사용한 CT검사에서 저관전압 기법에 따른 유용성 평가)

  • Jung, Kang-Kyo;Cho, Pyong-Kon
    • Journal of radiological science and technology
    • /
    • v.39 no.1
    • /
    • pp.71-79
    • /
    • 2016
  • The purpose of this study is computed tomography contrast agent at low concentrations and low tube voltage technique to evaluate the usefulness on the phantom image. By varying the degree of mixture by the contrast medium concentration it was inserted in phantom. It was taken by changing the tube voltage and tube current step by step, and to evaluate the dose and the CT value obtained from the phantom image. As a result, low-contrast, low tube voltage(300 mgI/ml, 100 kV) was reduced by an average 21%(CTDIvol; computed tomography dose indexvol) more standard condition(350 mgI/ml, 120 kV). SNR was increased at all depths of the phantom, respectively 1:10 and 1:20(by diluting a contrast agent and normal saline) 12.2(26%) 6.2(17%). CNR was increased at all depths of the phantom, respectively 1:10 and 1:20(by diluting a contrast agent and normal saline) 11.5(32%), 6.3(26%). Research work on the CT scan is necessary in a variety of studies on the low contrast concentration and low tube voltage techniques for dose reduction and reducing of side effects the contrast agent.

CT Findings and Accuracy of Preoperative Pathologic Diagnosis in Bronchial Carcinoid According to Subtype (기관지 유암종의 아형에 따른 CT 소견과 수술전 병리학적 진단의 정확성)

  • 임준석;홍용국;정경영;최규옥
    • Journal of Chest Surgery
    • /
    • v.31 no.4
    • /
    • pp.380-387
    • /
    • 1998
  • We evaluated CT findings of bronchial carcinoid and accuracy of preoperative pathological diagnosis according to two subtypes. The subjects were 10 cases(typical;5, atypical;5), confirmed by surgery and tissue pathology. Sputum cytology(n=10), percutaneous aspiration(n=1) and bronchoscopic biopsy (n=8) were performed, preoperatively. The CT findings were analysed according to two subtypes. Typical carcinoid shows central location in all, and bronchial lumens just proximal to tumor were widened in two, whereas atypical carcinoid presented as peripheral leison in two. Among central atypical carcinoid, two cases showed flat meniscus appearance of lumen. Remaining one showed diffuse wall thickening. Intratumoral low density by necrosis was noted in one. Both subtypes show contrast enhancement. For preoperative diagnosis, sputum cytology & percutaneous aspiration were not conclusive at all. As for bronchoscopic biopsy, only 3 cases were accurately diagnosed as typical carcinoid. Typical carcinoid presented as endobronchial mass in all, whereas atypical carcinoid presented in various appearance. In all atypical & some typical carcinoid were misdiagnosed as primary lung cancer, preoperatively. However, in typical carcinoid, conservative surgery was possible. In conclusion, if there is discrepancy between CT findings & preoperative pathological diagnosis, full understanding of CT findings of bronchial carcinoid is imperative to choose appropriate surgical modality.

  • PDF