• Title/Summary/Keyword: CT

Search Result 8,757, Processing Time 0.039 seconds

STRESS ANALYSIS OF SUPPORTING TISSUES ACCORDING TO IMPLANT FIXTURE DIAMETER AND RESIDUAL ALVEOLAR BONE WIDTH (치조골 폭경과 임플랜트 고정체의 직경에 따른 지지조직의 응력분포)

  • Han, Sang-Un;Vang, Mong-Sook;Yang, Hong-So;Park, Sang-Won;Park, Ha-Ok;Lim, Hyun-Pil
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.45 no.4
    • /
    • pp.506-521
    • /
    • 2007
  • Statement of problem: The cumulative success rate of wide implant is still controversial. Some previous reports have shown high success rate, and some other reports shown high failure rate. Purpose: The aim of this study was to analyze, and compare the biomechanics in wide implant system embeded in different width of crestal bone under different occlusal forces by finite element approach. Material and methods: Three-dimensional finite element models were created based on tracing of CT image of second premolar section of mandible with one implant embedded. One standard model (6mm-crestal bone width, 4.0mm implant diameter central position) was created. Varied crestal dimension(4, 6, 8 mm), different diameter of implants(3.3, 4.0, 5.5, 6.0mm), and buccal position implant models were generated. A 100-N vertical(L1) and 30 degree oblique load from lingual(L2) and buccal(L3) direction were applied to the occlusal surface of the crown. The analysis was performed for each load by means of the ANSYS V.9.0 program. Conclusion: 1. In all cases, maximum equivalent stress that applied $30^{\circ}$ oblique load around the alveolar bone crest was larger than that of the vertical load. Especially the equivalent stress that loaded obliquely in buccal side was larger. 2. In study of implant fixture diameter, stress around alveolar bone was decreased with the increase of implant diameter. In the vertical load, as the diameter of implant increased the equivalent stress decreased, but equivalent stress increased in case of the wide implant that have a little cortical bone in the buccal side. In the lateral oblique loading condition, the diameter of implant increased the equivalent stress decreased, but in the buccal oblique load, there was not significant difference between the 5.5mm and 6.0mm as the wide diameter implant. 3. In study of alveolar bone width, equivalent stress was decreased with the increase of alveolar bone width. In the vertical and oblique loading condition, the width of alveolar bone increased 6.0mm the equivalent stress decreased. But in the oblique loading condition, there was not a difference equivalent stress at more than 6.0mm of alveolar bone width. 4. In study of insertion position of implant fixture, even though the insertion position of implant fixture move there was not a difference equivalent stress, but in the case of little cortical bone in the buccal side, value of the equivalent stress was most unfavorable. 5. In all cases, it showed high stress around the top of fixture that contact cortical bone, but there was not a portion on the bottom of fixture that concentrate highly stress and play the role of stress dispersion. These results demonstrated that obtaining the more contact from the bucco-lingual cortical bone by installing wide diameter implant plays an important role in biomechanics.

Chest Computerized Tomographic Scan and Flexible Fiberoptic Bronchoscopy in the Diagnosis of Middle Lobe Syndrome (페중엽증후군에서 흉부 전산화 단층촬영 및 굴곡성 기관지경검사의 의의)

  • Lee, Nam-Ho;Lee, Hong-Leyol;Kim, Se-Kye;Chang, Joon;Kim, Sung-Kyu;Lee, Won-Young
    • Tuberculosis and Respiratory Diseases
    • /
    • v.39 no.3
    • /
    • pp.236-241
    • /
    • 1992
  • Background: As well as fiberoptic bronchoscopy, chest computerized tomographic scan can now differentiate the benign from malignant causes and the obstructive from non-obstructive causes of lung collapse. This study was designed to evaluate the usefulness of chest CT scan and fiberoptic bronchoscopy in the diagnosis of middle lobe syndrome. Method: We reviewed the clinical features, roentgenographic changes, pathologic findings and bronchoscopic findings in 16 patients with middle lobe syndrome who were admitted to Severance Hospital during period of January, 1987 through January, 1992. Results: The male to female ratio was 1:1. The most common symptoms were cough and sputums. Crackle was the most common physical finding. Underlying disease was lung cancer, pulmonary tuberculosis and endobronchial tuberculosis in 3 each other, benign stenosis in 2, lung abscess, broncholithiasis, bronchial chondroma, pneumonia and nonspecific inflammation in 1 each other. Conclusion: We conclude that the combination of chest computerized tomogram and fiberoptic bronchoscopy was most desirable for the diagnosis of middle lobe syndrome.

  • PDF

Usefulness of $^{99m}Tc$ Methoxyisobutylisonitrile Lung SPECT in Benign and Malignant Lesion of the Lungs (폐의 양성 및 악성 병변에서 $^{99m}Tc$ Methoxyisobutylisonitrile Lung SPECT의 진단적 가치)

  • Kim, Seong-Suk;Kim, Ki-Beom;Cho, Young-Bok;Cho, In-Ho;Lee, Kyung-Hee;Chung, Jin-Hong;Lee, Hyoung-Woo;Lee, Kwan-Ho;Lee, Hyun-Woo;Kim, Mi-Jin
    • Tuberculosis and Respiratory Diseases
    • /
    • v.43 no.1
    • /
    • pp.54-62
    • /
    • 1996
  • Background: $^{99m}Tc$ MIBI(Methoxyisobutylisonitrile complex), a member of the isonitrile class of coordination compounds, is a lipophilic cation presently under investigation for clinical use as myocardial perfusion imaging agent and is widely used to detect myocardial infarction. Preliminary reports indicate that $T_1$-201 accumulate in human neoplasm and several authors reported $^{99m}Tc$ MIBI may also localized in primary malignant tumor and metastatic deposits from lung cancer. We evaluated the uptake of $^{99m}Tc$ MIBI in lung cancer and localization of mediastinal and other site metastasis, and compared the benign lesion of the lung. Method: Thirty four patients of lung cancer and ten patients of benign lung lesion were studied with chest CT and $^{99m}Tc$ MIBI Lung SPECT. $^{99m}Tc$ MIBI uptake ratio was assessed by TR/NL(Lung lesion/ Normal area), HT/NL (Heart/Normal area) and HT/TR(Heart/Lung lesion). Results: 1) All lung cancer patients showed increased uptakes of $^{99m}Tc$ MIBI in malignant lung lesion and Tc-99m MIBI uptake was also increased in mediastinal and lymph node metastasis except two cases. 2) There was significant different ratio of TR/NL between malignant and benign lesion, $3.79{\pm}1.82$ and $1.67{\pm}0.63$ on planar images, respectively(p<0.001). 3) There was no significant difference of $^{99m}Tc$ MIBI uptake ratio between squamous cell carcinoma, small cell carcinoma and adeno carcinoma($3.64{\pm}1.66$, $3.57{\pm}0.72$, $4.31{\pm}2.28$ respectively). Conclusion: $^{99m}Tc$ MIBI lung SPECT was useful in the localization of tumor and mediastinal or other site metastatic lesion in lung cancer and also in the differential diagnosis between benign and malignant lesion.

  • PDF

The pattern of movement and stress distribution during retraction of maxillary incisors using a 3-D finite element method (상악 전치부 후방 견인 시 이동 양상과 응력 분포에 관한 삼차원 유한요소법적 연구)

  • Chung, Ae-Jin;Kim, Un-Su;Lee, Soo-Haeng;Kang, Seong-Soo;Choi, Hee-In;Jo, Jin-Hyung;Kim, Sang-Cheol
    • The korean journal of orthodontics
    • /
    • v.37 no.2 s.121
    • /
    • pp.98-113
    • /
    • 2007
  • Objective: The purpose of this study was to evaluate the displacement pattern and the stress distribution shown on a finite element model 3-D visualization of a dry human skull using CT during the retraction of upper anterior teeth. Methods: Experimental groups were differentiated into 8 groups according to corticotomy, anchorage (buccal: mini implant between the maxillary second premolar and first molar and second premolar reinforced with a mini Implant, palatal: mini implant between the maxillary first molar and second molar and mini implant on the midpalatal suture) and force application point (use of a power arm or not). Results: In cases where anterior teeth were retracted by a conventional T-loop arch wire, the anterior teeth tipped more postero-inferiorly and the posterior teeth moved slightly in a mesial direction. In cases where anterior teeth were retracted with corticotomy, the stress at the anterior bone segment was distributed widely and showed a smaller degree of tipping movement of the anterior teeth, but with a greater amount of displacement. In cases where anterior teeth were retracted from the buccal side with force applied to the mini implant placed between the maxillary second premolar and the first molar to the canine power arm, it showed that a smaller degree of tipping movement was generated than when force was applied to the second premolar reinforced with a mini implant from the canine bracket. In cases where anterior teeth were retracted from the palatal side with force applied to the mini implant on the midpalatal suture, it resulted in a greater degree of tipping movement than when force was applied to the mini implant between the maxillary first and second molars. Conclusion: The results of this study verifies the effects of corticotomies and the effects of controlling orthodontic force vectors during tooth movement.

Relation Between Degree of Consistency of Elementary Students' Preconceptions on the Brightness of Electric Bulb and Their Cognitive Conflict (전구의 밝기에 대한 초등학생들의 사전개념 일관성 정도와 인지갈등 정도와의 관계)

  • Jung Mee-young;Kim Kung-suk;Kwon Jaesoo
    • Journal of Korean Elementary Science Education
    • /
    • v.24 no.3
    • /
    • pp.259-267
    • /
    • 2005
  • This study was to investigate the elementary students' preconception on the brightness of electric bulb and degree of consistency on their preconceptions. Participants were 160 students of fifth graders in Seoul area. They had already teamed about the brightness of series circuit and parallel circuit of batteries. After they solved six problems in the same context, we provided them a pair of circuit which was an anomalous situation. And then they conducted CCLT (Cognitive Conflict Level Test). Elementary school students showed various preconceptions when they explained the light of bulb of two Simple electric Circuits. Many Students Consistently Showed the Scientific misconceptions like 'the light of bulb of two simple electric circuits was that the more batteries and the fewer bulbs were brighter.' The level of consistency that students presented scientific misconceptions was grouped all of four, such as 'high, middle, low, and nothing.' Therefore the higher scientific achievement they have, the higher consistency they have. As the students had high consistency level, they revealed high cognitive conflict level significantly. This high consistency will help them to change their preconception on the brightness of electric bulb and their cognitive conflict.

  • PDF

Climatological Characteristics in the Variation of Soil temperature in Korea (우리나라 지중온도 변동의 기후학적 특성)

  • Kim Seoung-Ok;Suh Myoung-Seok;Kwak Chong-Heum
    • Journal of the Korean earth science society
    • /
    • v.26 no.1
    • /
    • pp.93-105
    • /
    • 2005
  • Climatological characteristics in the variation of soil temperatures in Korea were investigated using Korea Meterological Administration's observation data. And the impacts of soil moisture on the variation of soil temperature were examined using observed precipitation data. The climatological averages of soil temperatures are ranged from 14.4 to $15.0^{\circ}C$ regardless of depths. And they showed an latitudinal gradient with a warm temperature at the southern region and 'U' shape as in the air temperature with a high value along the coastal region. The relatively higher heat capacity and low conductivity of soil compared to those of the air resulted in the significant delay of the maximum and minimum date with depth. As a results, soil acts as a heat source during winter while a heat sink during summer. Global warming and urban heat island have increased the soil temperatures with an average rate $0.3\~0.5^{\circ}C/10-year$ as in the air temperature during last 30 years $(1973\~2002)$. However, the warming rate is maximized during spring contrary to the winter in the air temperature. The temporal variation of soil temperatures is strongly affected by that of soil moisture through an modification of the heat capacity and heat convection. In general, the increased soil moisture clearly decreased the temporal variations and increased the deep layer soil temperatures during cold season.

Effect of the Number and Location of Implants on the Stress Distribution in Three-unit Fixed Partial Denture: A Three-Dimensional Finite Element Analysis (임플란트 고정성 보철물에서 수와 식립위치 변화에 따른 골과 임플란트에서의 응력분포에 관한 3차원 유한요소법적 연구)

  • Lee, Woo-Hyun;Lim, Jong-Hwa;Cho, In-Ho
    • Journal of Dental Rehabilitation and Applied Science
    • /
    • v.26 no.3
    • /
    • pp.221-239
    • /
    • 2010
  • Bone loss may occur depending on the loading conditions. careful treatment planning and prosthetic procedures are very important factors for the proper distribution of stress. Evaluate the stress distributions according to numbers and location of implants in three-unit fixed partial dentures. A mandible missing the right second premolar, first molar and second molar was modeled. Using the CT data. we modeled a mandible with a width of 15mm, a height of 20mm and a length of 30mm, 2mm-thickness cortical bone covering cancellous bone mallow. An internal type implant and A solid type abutment was used. A model with 3 implants placed in a straight line, offset 1.5 mm buccally, offset 1.5 mm lingually and another model with 3 implants offset in the opposite way were prepared. And models with 2 implants were both end support models, a mesial cantilever model and a distal cantilever model. Three types of loading was applied; a case where 155 N was applied solely on the second premolar, a case where 206 N was applied solely on the second molar and a case where 155 N was applied on the first premolar and 206 N was applied on the first and second molar. For all the cases, inclined loads of 30 degrees were applied on the buccal cusps and vertical loads were applied on the central fossas of the teeth. Finite element analysis was carried out for each case to find out the stress distribution on bones and implants. This study has shown that prostheses with more implants caused lower stress on bones and implants, no matter what kind of load was applied. Furthermore, it was found out that inclined loads applied on implants had worse effects than vertical loads. Therefore, it is believed that these results should be considered when placing implants in the future.

A Hardware Implementation of Image Scaler Based on Area Coverage Ratio (면적 점유비를 이용한 영상 스케일러의 설계)

  • 성시문;이진언;김춘호;김이섭
    • Journal of the Institute of Electronics Engineers of Korea SD
    • /
    • v.40 no.3
    • /
    • pp.43-53
    • /
    • 2003
  • Unlike in analog display devices, the physical screen resolution in digital devices are fixed from the manufacturing. It is a weak point on digital devices. The screen resolution displayed in digital display devices is varied. Thus, interpolation or decimation of the resolution on the display is needed to make the input pixels equal to the screen resolution., This process is called image scaling. Many researches have been developed to reduce the hardware cost and distortion of the image of image scaling algorithm. In this paper, we proposed a Winscale algorithm. which modifies the scale up/down in continuous domain to the scale up/down in discrete domain. Thus, the algorithm is suitable to digital display devices. Hardware implementation of the image scaler is performed using Verilog XL and chip is fabricated in a 0.5${\mu}{\textrm}{m}$ Samsung SOG technology. The hardware costs as well as the scalabilities are compared with the conventional image scaling algorithms that are used in other software. This Winscale algorithm is proved more scalable than other image-scaling algorithm, which has similar H/W cost. This image-scaling algorithm can be used in various digital display devices that need image scaling process.

Patients satisfaction for implant supported overdenture with small diameter implant (작은 직경 임플란트를 이용한 임플란트 지지 피개의치에 대한 환자 만족도 조사)

  • Lee, Sang-Yeup;Choi, Dae-Gyun;Paek, Jang-Hyun;Kwon, Kung-Rock
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.49 no.1
    • /
    • pp.29-37
    • /
    • 2011
  • Purpose: In cases when implant supported overdenture is made by using standard size implant, additional procedure such as bone surgery and bone grafting can be required. And it gives burden to doctor and patient in terms of cost. Therefore, it is necessary to find the implant therapy for the edentulous patients in making denture with accordable cost and simple procedure. Materials and methods: Edentulous patients with upper and lower dentures participated in this study. Before the operation, survey about patient's satisfaction to the existing dentures was carried out. Surgical procedures included four small diameter implants installation anterior area and immediate loading. One and three month after the procedure, the same survey about patient's satisfaction was carried out, and radiography was taken. Results: We are doing research to the nine patients. Survival rate is 97.2 percent. The comparison of patient's satisfaction before and after surgery is performed based on oral health impact profile 49. We analyze mainly with masticatory discomfort, retention, aesthetics, social problem, psychological discomfort problems. As a result, satisfaction level is increased at all factors. Retention is the most increased satisfactory factor followed by mastication difficulty, pronunciation, psychological discomfort, social discomfort, aesthetics in order. Marginal bone loss is 0.21 mm at 12 weeks after implant placement. Conclusion: This research reveals that the denture supported by mini dental implant increases patient's satisfaction. This study will be continued with more patients for a long time and we are scheduled for taking additional radiography to check whether peri-implant bone resorption occurs or not.

REMINERALIZATION EFFECTS OF GLASS IONOMER RESTORATIONS ON ADJACENT INTERPOXIMAL-A MICROTOMOGRAPHIC STUDY (미세전산화 단층 촬영을 이용한 글라스 아이오노머 수복의 인접면 재광화 효과에 대한 연구)

  • Lee, Hyeok-Sang;Lee, Sang-Dae;Kim, Jung-Wook;Kim, Chong-Chul;Hahn, Se-Hyun;Jang, Ki-Taeg
    • Journal of the korean academy of Pediatric Dentistry
    • /
    • v.31 no.3
    • /
    • pp.474-480
    • /
    • 2004
  • The purpose of this in vitro study was to compare the remineralizing effects of three glass ionomer cements (high filled glass ionomer cement, compomer, resin modified glass ionomer cement) with resin composite (control group) on incipient interproximal caries, and to assess long-term change of remineralization effect, in each material, evaluated by microtomography. Proximal restoration was simulated with tooth specimen and Glass Ionomer Cements. And each of these groups was placed into a closed container with artificial saliva at $37^{\circ}C$ and pH 7.0 for a time period of thirty days with constant circulation. At the end of thirty and sixty days, tomographic images were taken from these specimens with micro CT scanner. Materials used in this study were as follows. Group 1: Fuji IX GP (GC Corp., Tokyo, Japan) Group 2: Vitremer (3M ESPE, St. Paul, Minn., USA) Group 3: F2000 (3M ESPE, St. Paul, Minn., USA) Group 4: Z250 (3M ESPE, St. Paul, Minn., USA) Using density-measuring program, the micro-density of carious lesions on the specimens were measured. The mean density changes of each group were compared to the other groups to evaluate the effect of remineralization. The results were as follows: 1. The lesion density of all groups increased. 2. The mean density increase of Group 1, 2, 3 were higher than that of Group 4 every month(p<0.05). 3. There were significant differences of density increase among glass ionomer group(Group 1, 2, 3).

  • PDF