• 제목/요약/키워드: CP-titanium

검색결과 113건 처리시간 0.02초

A.c. Impedance Measurement of CP-Ti in 0.1 M NaOH Solution

  • Moon, Sungmo;Kwon, Mikyung;Kim, Jusuk
    • Journal of Electrochemical Science and Technology
    • /
    • 제3권4호
    • /
    • pp.185-189
    • /
    • 2012
  • A.c. impedances of mechanically polished CP-Ti specimens were measured at open-circuit potential (OCP) with immersion time and under applied anodic potentials between -0.2 and 1 $V_{Ag/AgCl}$ in 0.1 M NaOH solution. Capacitances of native oxide films ($C_{ox,na}$) grown naturally and capacitances of anodic oxide films ($C_{ox,an}$) formed under applied anodic potentials were obtained to examine the growth of native and anodic oxide films in 0.1 M NaOH solution and how to use $C_{ox,na}$ for the surface area measurement of Ti specimen. $1/C_{ox,na}$ and $1/C_{ox,an}$ appeared to be linearly proportional to OCP and applied potential ($E_{app}$), with proportional constants of 0.086 and 0.051 $uF^{-1}\;V^{-1}$, respectively. The $C_{ox,na}$ also appeared to be linearly proportional to geometric surface area of the mechanically polished CP-Ti fixture specimen, with proportional constants of 11.3 and $8.5{\mu}F\;cm^{-2}$ at -0.45 $V_{Ag/AgCl}$ and -0.25 $V_{Ag/AgCl}$ of OCPs, respectively, in 0.1 M NaOH solution. This linear relationship between $C_{ox,na}$ and surface area is suggested to be applicable for the measurement of real surface area of Ti specimen.

적층가공된 티타늄 합금의 전기화학적 특성에 미치는 불산의 영향 (Effect of Hydrofluoric Acid on the Electrochemical Properties of Additive Manufactured Ti and Its Alloy)

  • 김기태;조현우;장현영;김영식
    • Corrosion Science and Technology
    • /
    • 제17권4호
    • /
    • pp.166-175
    • /
    • 2018
  • In this study, the electrochemical properties of CP-Ti (commercially pure titanium) and Ti-64 (Ti-6Al-4V) were evaluated and the effect of hydrofluoric acid on corrosion resistance and electrochemical properties was elucidated. Additive manufactured materials were made by DMT (Directed Metal Tooling) method. Samples were heat-treated for 1 hour at $760^{\circ}C$ and then air cooled. Surface morphologies were studied by optical microscope and SEM. Electrochemical properties were evaluated by anodic polarization method and AC-impedance measurement. The oxide film formed on the surface was analyzed using an XPS. The addition of HF led to an increase in the passive current density and critical current density and decreased the polarization resistance regardless of the alloys employed. Based on the composition of the oxide film, the compositional difference observed by the addition of HF was little, regardless of the nature of alloys. The Warburg impedance obtained by AC-impedance measurement indicates the dissolution of the constituents of CP-Ti and Ti-64 through a porous oxide film.

Effects of cp-Ti Surface Roughness and Directionality on Initial Cell Attachment Behaviors

  • Shin, Dong-Hoon;Chun, Sungsu;Ahn, Myun-Whan;Song, In-Hwan;Kim, Sukyoung
    • 대한금속재료학회지
    • /
    • 제50권4호
    • /
    • pp.338-343
    • /
    • 2012
  • The early osseointegration of titanium (Ti) dental implants is related to the initial cell morphology. The morphology of the cells (mesenchymal stem cells, MSC) was observed on three different Ti disc surfaces, which were mechanically treated by polishing, blasting, and scratching. A non-directional surface (isotropic texture) was obtained by the blasting of HA grits on cp-Ti discs, and a unidirectional surface (anisotropic texture) was obtained by the scratching of SiC papers. The cell attachment and arrangement in the initial periods were quite similar, but those in the later periods were significantly affected by the texture of the cp-Ti discs. After 1 week, the blasted Ti discs showed non-directional arrangement or spreading of the cells, whereas the scratched cp-Ti discs showed unidirectional properties parallel to the direction of the scratched grooves on the surface. The surface roughness of the cp-Ti discs significantly affects cell proliferation. Cell proliferation on the blasted and scratched surfaces was about 60% and 40% higher compared to the control result (polishing group) after 1 week (P<0.05). Cell proliferation on the blasted and scratched surfaces after 1 week was slightly enhanced with increasing surface roughness. It is believed that the direction of cell attachment and arrangement is closely related to the surface texture of the substrate surfaces, but cell proliferation after a relatively long period of time is directly enhanced by the surface roughness, not by the surface texture.

타이타늄 상악 주연결장치에 디자인에 따른 주조성 및 견고성 비교 (COMPARISON OF RIGIDITY AND CASTABILITY IN DIFFERENT DESIGNS OF MAXILLARY MAJOR TITANIUM FRAMEWORK)

  • 이영재;방몽숙;양홍서;박상원;박하옥;임현필
    • 대한치과보철학회지
    • /
    • 제45권4호
    • /
    • pp.431-443
    • /
    • 2007
  • Statement of problem: Injuries along with discomfort may result on the oral mucosa when non-rigid material is used as the major connector in construction of RPD, since nonrigid major connectors transmit unstable forces throughout the appliance. Titanium which recently draws attention as a substitute of Co-Cr had a difficulty in fabricating due to high melting temperature but the development of casting technique makes it possible to apply to the clinical case. Purpose: The purpose of this study was to investigate the rigidity and the castability of titanium upper major connector by design and make a comparison with Co-Cr major connectors which are widely used in clinical cases now. Material and methods: Casting was done using CP-Ti(Grage 2) (Kobe still Co., Japan) for the experimental groups, and 4 various designs namely palatal strap, U-shaped bar, A-P strap, and complete palatal plate were casted and 5 of each designs were included in each group. For the experimental group, Universal testing machine (Model 4502; Instron, Canton, Mass) was used to apply vertical torsional force vertically to the horizontal plane of major connector. In the second experiment, Vertical compressive force was applied to the horizontal plane of major connector. As a comparative group, Co-Cr major connector was equally manufactured and underwent the same experimental procedures Strain rate was measured after constant loading for one minute duration, and statistical analysis was done with SPSS ver.10.0 for WIN(SPSS. Inc. USA). From the one-way ANOVA and variance analysis (P=0.05), Scheffe's multiple comparison test implemented. Results: 1. Least amount of strain was observed with complete palatal plate followed by A-P bar, palatal bar, and the U-shaped bar having most amount of strain. 2. In all designs of titanium major connector, less strain rate was observed under compressive loading than under torsional loading showing more resistance to lateral force. 3. For titanium major connector, less strain rate was observed when the force is applied to the first premolar area rather than to the second molar area indicating more strength with shorter length of lever. 4. In Comparison of Co-Cr major connector with titanium major connector, palatal strap and U-shaped bar designs showed higher strength under torsional force that is statically significant, and under compressive force, no significant difference was observed expert for U-shaped bar. 5. In titanium major connector, complete palatal plate showed lowest success rate in casting when compared with the Co-Cr major connector. Conclusion: Above results prove that when using titanium for major connector, only with designs capable of generating rigidity can the major connector have almost equal amount of rigidity as Co-Cr major connector and show lower success rate in casting when compared with the Co-Cr major connector.

열산화법에 의한 티타늄 임플란트의 인산칼슘 결정의 형성 능력 증진 (Improvement of Calcium Phosphate Forming Ability of Titanium Implant by Thermal Oxidation Method)

  • 황규석;안준형;이선옥;윤연흠;강보안;오정선;김상복
    • 한국세라믹학회지
    • /
    • 제39권5호
    • /
    • pp.460-466
    • /
    • 2002
  • 티타늄 임플란트의 표면을 열산화법을 이용하여 티타늄의 표면 위에 생체활성을 갖는 $TiO_2$ 박막을 생성시켜 다양한 의료분야의 응용 가능성을 검토하였다. 시판되고 있는 순수한 티타늄 디스크를 세척 공정을 거친 후, 공기와 아르곤 분위기에서 500, 550, 600, 650, 700${\circ}C$의 온도로 10분간 각각 열산화 처리를 실시하였다. 열처리된 시편의 인산칼슘 결정의 형성 능력을 시험하기 위하여 36.5${\circ}C$의 Eagle's minimum essential medium 용액에서 15일 동안 침적시험을 행하였다. 침적하기 전과 후의 시편의 표면 형상과 표면 조성을 Field Emission-Scanning Electron Microscopy(FE-SEM)와 Energy Dispersive X-ray Spectrometry(EDS)로 각각 분석하였다. In vitro 시험에서 미세한 $TiO_2$ 결정이 생성된 박막의 표면에는 탄소가 함유된 인산칼슘 결정이 생성됨을 확인하였다.

티타니움 표면의 알칼리-열처리가 골모세포의 분화에 미치는 영향 (The Effect of Alkali- and Heat-Treated Titanium Surfaces on Differentiation of Osteoblast)

  • 강충희;방몽숙;양홍서;박상원;임현필
    • 구강회복응용과학지
    • /
    • 제25권3호
    • /
    • pp.293-306
    • /
    • 2009
  • 본 연구에서는 알카리 열처리 티타늄 임플란트상에서 백서 태자 두개관 세포의 생물학적 반응을 알아보고자 하여 다음과 같은 결과를 얻었다. 알카리 열처리 티타니움 표면에서 Ti-6Al-4V 합금 표면에서보다 세포증식도가 유의하게 높았다 (p<0.01). 면역효소 분석에서 interleukin $(IL)-1{\beta}$와 IL-6의 합성은 배양 시간이 길수록 증가하였다. Herbimycin으로 전처치한 경우에는 세포 배양 7일 째에 IL-6의 합성이 유의하게 억제되었다(p<0.01). 알카리인산 분해 효소 활성은 알카리 열처리 임플란트에서 타이타늄, Ti-6Al-4V 합금 표면에서 보다 유의하게 더 높았다 (p<0.001). 유전자 분석에서 알카리 열처리 임플란트에서 배양된 세포들의 alkaline phosphatase, bone sialoprotein, receptor activated nuclear factor ligand 유전자의 발현이 증가하였다. Herbimycin과 SB203580으로 전처치시 $IL-1{\beta}-induced$ IL-6 유전자의 발현이 감소하였다. 이상의 결과는 알카리 열처리된 티타늄 임플란트가 조골세포의 분화를 자극하고 골개조를 촉진시킴을 시사한다.

Ti-8Ta-3Nb 합금의 표면처리에 의한 백서 두개관 세포의 반응 (Biological response of primary rat calvarial cell by surface treatment of Ti-8Ta-8Nb alloy)

  • 김해진;손미경;박지일;정현주;김영준
    • Journal of Periodontal and Implant Science
    • /
    • 제38권4호
    • /
    • pp.595-602
    • /
    • 2008
  • Purpose: Ti-6Al-4V alloy is widely used as an implant material because of its good biocompatibility and good mechanical property compared with commercial pure titanium. Otherwise, toxicity of aluminum and vanadium in vivo has been reported. Ti-8Ta-3Nb alloy is recently developed in the R&D Center for Ti and Special Alloys and it was reported that this alloy has high mechanical strength, no cytotoxicity and similar biocompatibility to commercial pure titanium, but many studies are needed for its clinical use. In these experiment, we carried out different surface treatment on each Ti-8Ta-3Nb alloy disks, then cultured cell on it and assessed biological response. Materials and Methods: cpTi, Ti-6Al-4V, Ti-8Ta-3Nb alloy disks were prepared and carried out sandblasting and acid etching (SLA) or alkali-heat treatment (AH) on the Ti-8Ta-3Nb alloy disks. We cultured primary rat calvarial cells on each surface and assessed early cell attachment and proliferation by scanning electron microscopy, cell proliferation, alkaline phosphatase activity. Result: The rates of cell proliferation on the cpTi, Ti-8Ta-3Nb AH disks were higher than others (p<0.05) and alkaline phosphatase activity was significantly enhanced on the Ti-STa-8Nb AH disks(p<0.05). Conclusion: Most favorable cell response was shown on the Ti-8Ta-3Nb AH surfaces. It is supposed that alkali-heat treatment of the Ti-8Ta-3Nb alloy could be induced earlier bone healing and osseointegration than smooth surface.

유압벌지실험을 이용한 순 티탄늄 판재의 소성유동곡선 평가(제2보) (Evaluation of plastic flow curve of pure titanium sheet using hydraulic bulge test)

  • 김영석;김진재
    • 한국산학기술학회논문지
    • /
    • 제17권4호
    • /
    • pp.718-725
    • /
    • 2016
  • 본 논문에서는 대형 선박의 판형 열교환기 등에 널리 이용되고 있는 순 티타늄 판재의 소성변형을 유한요소해석하기 위한 기초 데이터로서 순 티타늄 판재의 유동곡선을 평가하였다. 순 티타늄 판재의 프레스 가공 시에 판재에는 국부적으로 큰 소성변형이 발생하고 있다. 그러나 기존의 단축 인장실험에서 얻을 수 있는 소성변형률이 낮아서 티타늄 판재의 가공공정 설계를 위한 유한요소해석의 정밀도를 떨어뜨리는 경우가 있다. 본 연구에서는 큰 소성변형률 까지 안정적으로 성형이 가능한 유압벌지실험을 수행하여 재료의 소성변형에서 가공경화특성을 나타내는 유동곡선으로써 진응력-진변형률 선도를 구하였고 그 결과를 인장실험 결과와 비교하였다. 순 티타늄 판재의 유압벌지실험에서 재료의 변형률은 3D 디지털 영상상관법을 이용한 ARAMIS 시스템으로 실시간 측정된다. 이 유압벌지실험으로부터는 소성 변형률이 0.65 이상 까지도 안정적으로 재료의 소성유동곡선을 얻을 수 있었으며 그 결과는 Kim-Tuan 이 문헌 17[Y.S. Kim, J.H. In, Korean Acadmia-Ind. Coop. Soc.,(be in print), 2016] 의 연구에서 제안한 가공경화식으로 잘 핏팅됨을 알 수 있었다.

NaOH처리와 SBF침적에 따른 CP-Ti, Ti-6Al-4V 및 ECAP-Ti의 표면 아파타이트 성장 (Surface Apatite Growth of NaOH and SBF Treated CP-Ti, Ti-6Al-4V and ECAP-Ti)

  • 오석진;류재경;이승우;김윤종;한만소;김창규
    • 한국재료학회지
    • /
    • 제14권12호
    • /
    • pp.893-899
    • /
    • 2004
  • Even though Ti-6Al-4V has gained popularity as an implant material, the possible dissolution of Al and V ions in body fluids remains a matter of concern. Though commercially pure Ti (Cp-Ti) overcomes this problem, the mechanical strength of pure titanium remains very low. Thus, in this experiment Cp-Ti was processed by Equal channel angular processing (ECAP), in order to increase the mechanical strength. The biocompatibility of ECAP-Ti, Cp-Ti and Ti-6Al-4V was examined by the apatite formation on each sample surface, after treating the surface with 5M NaOH and soaking in Simulated body fluids (SBF). Initially, the samples were mechanically polished on silicone carbide paper (#2000). The polished samples were treated with 5M NaOH solution at $60^{\circ}C$ for 24 hours. The NaOH treated samples were washed gently with distill water and dried at $40^{\circ}C$ for 1 day. The dried samples were heat treated in air at $600^{\circ}C$ for 1 hour. The surface morphology of these samples were studied using SEM and XRD. The SEM studies showed network of pores in all samples. The XRD showed oxide layer formation on Cp-Ti and Ti-6Al-4V. samples. However the oxide layer in ECAP-Ti was not substantial. These samples were immersed in SBF, kept at $36.5^{\circ}C$ for seven days period. At the end of 7 days, the apatite formation was confirmed only on Cp-Ti and was not observed in Ti-6Al-4V and ECAP-Ti. These observations of apatite formation relate to the fact that Cp-Ti showed greater oxide layer than other samples. The apatite examined was confirmed as tricalcium phosphate (TCP) using EDS and XRD.