• Title/Summary/Keyword: COP

Search Result 1,228, Processing Time 0.028 seconds

A Study on Change in Gait Parameters Related to the Cop and Velocity Resulting from the Use of Ankle Foot Orthosis in Spastic Diplegia (경직성 양하지마비아의 발목 보조기 착용에 따른 체 중심및 보행속도에 의한 보행인자 변화연구)

  • Park, Mi-Sook;Kim, Yong-Seong;Hwang, Tae-Yeon;Kim, Yong-Nam
    • Journal of the Korean Academy of Clinical Electrophysiology
    • /
    • v.10 no.1
    • /
    • pp.23-28
    • /
    • 2012
  • Purpose : The objectives of this study were to examine changes in gait parameters related to the COP and gait velocity resulting from the use of ankle foot orthosis, and to provide information for the prescription of ankle foot orthosis and gait rehabilitation training. Methods : We sampled a control group of 14 normal children of the same age as the spastic diplegia (spastic diplegia used ankle foot orthosis) and measured their COP at barefoot gait and their gait parameters at three gait velocities. Change in the COP according to the use of ankle foot orthosis measured one-way ANOVA and Gait parameters according to gait velocity used repeated measures ANOVA. Results : As a result of analyzing change in the COP it became close to that of normal children, and changes in gait parameters such as step width, stride length and stride time also became close to those of normal children. Conclusion : In conclusion, when spastic diplegia used ankle foot orthosis, their balancing ability was improved as a result of decreased change in the COP, and their changes in gait parameters also became close to those of the control group. These results show that the use of ankle foot orthosis improves spastic diplegia gait functions.

Experimental Study on Cooling Performance of A/C applied Fin-tube and PF Heat Exchangers (핀-관, 평행류 열교환기를 적용한 공조기의 냉방성능 실험연구)

  • Kwon, Young-Chul;Park, Yoon-Chang;Kwon, Jeong-Tae;Park, Gyung-Man
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.10 no.8
    • /
    • pp.1789-1794
    • /
    • 2009
  • In the present study, the cooling performance characteristics on environment changes of A/C applied fin-tube and PF heat exchangers were experimentally investigated. Capacity and COP on an air velocity, an indoor/outdoor temperature and an indoor/outdoor relative humidity were obtained. Fin types of PF heat exchanger were a triangler and squarer form. The experimental data for the three kinds of heat exchangers were measured using the air-enthalpy calorimeter. Performance of PF A/C was more excellent than that of a fin-tube A/C. Also, the performance of PF-2 A/C with the squarer fin was more excellent than that of PF-1 A/C with the triangler fin. As the air velocity, the indoor temperature and the indoor relative humidity increase, capacity and COP increase. And as outdoor temperature increases, capacity and COP decrease. But, the performance change on the outdoor relative humidity was insignificant.

The Effect of Functional Leg Length Inequality in Center of Pressure and Limits Of Stability (기능적 다리 길이 차이가 압력 중심점과 안정성 한계에 미치는 영향)

  • Jo, A-Ra;Min, Ji-Won;Son, Kwang-Hee;Lee, Yu-Ri;Ha, Min-Ju;Koo, Hyun-Mo
    • PNF and Movement
    • /
    • v.12 no.4
    • /
    • pp.201-207
    • /
    • 2014
  • Purpose: The purpose of this study was functional leg length inequality effect on COP(Center Of Pressure) and LOS(limits Of Stability) and EMG activation. Methods: The participants were consisted of fourteen. Subjects were distributed 2 groups; control group, leg length inequality ${\leq}3mm$, n=8), experimental group(leg length inequality${\geq}10mm$, n=8). The participants were measured leg length wearing comfortable clothes through tape measure method(TMM). All subjects was measured COP(Center Of Pressure), LOS(limits of stability) using by Balance Trainer BT4(HUR, Finland). Results: The results COP was not exist statistical significant differences(p>0.05). LOS was not exist statistical significant difference(p>0.05). Conclusion: The results was not statistical significant differences COP and LOS depending on Leg Length Inequality. But between experimental group and comparison group was exist mean differences on COP, LOS(COP:Ex.>Com, LOS:Ex.

Climate change messages in the fashion industry discussed at COP28

  • Yeong-Hyeon Choi;Sangyung Lee
    • The Research Journal of the Costume Culture
    • /
    • v.32 no.4
    • /
    • pp.517-546
    • /
    • 2024
  • The aim of this study is to investigate the fashion industry's response to climate change and how these discussions unfolded at the 28th Conference of the Parties (COP28) to the United Nations Framework Convention on Climate Change (UNFCCC). Climate change response projects by B Corp-certified fashion companies are examined, focusing on stakeholder efforts and reviewing online media reports. Text data were collected from web documents, interviews, and op-eds relating to COP28 from December 2018 to April 2024 and analyzed using text mining and semantic network analysis to identify critical keywords and contexts. The analysis revealed that the fashion industry is fulfilling its environmental responsibilities through various strategies, prompting changes in consumer behavior by advocating sustainable consumption, including carbon removal, energy transition, and recycling promotion. Stakeholders in online media and those present at COP28 discussed issues relating to climate change in the fashion industry, focusing on environmental protection, energy, greenhouse gas emissions, sustainable material usage, and social responsibility. Key issues at COP28 included policy and regulation, climate change response, energy transition, carbon emissions management, and environmental, social, and governance (ESG) standards. Additionally, by examining the main collections exhibited at the fashion show during COP28, the study analyzed how messages about climate change were conveyed. Fashion companies communicated the industry's response through exhibitions and fashion shows, suggesting a move toward balancing environmental protection and economic growth through the development of sustainable materials, the expansion of recycling and reuse practices, and the modern reinterpretation of cultural heritage.

Effect of ankle joint taping treatment on lower extremity joint and center of pressure factors during the Uchi-mata (허벅다리걸기 동작 시 발목 관절의 테이핑 처치가 하지 관절과 압력 중심 요인들에 미치는 영향)

  • Yun, Hyun
    • Journal of the Korean Applied Science and Technology
    • /
    • v.37 no.2
    • /
    • pp.224-231
    • /
    • 2020
  • The purpose of this study was to analyze the effect of ankle joint taping treatment on lower extremity joint and center of pressure(COP) factors during the Uchi-mata. Twenty college judo athletes (age, 20.9 ± 0.8 years; height, 168.6 ± 7.4cm; weight, 73.5 ± 11.6kg; body mass index, 25.7 ± 2.6kg/㎡) participated, and two types before and after ankle joint taping treatment when the during the Uchi-mata was exhibited under conditions, the angle and COP factors of the support leg joints were analyzed to show the following results. At the time of E2 (t = 2.411, p = .027) E4 (t = 2.388, p = .029), the ankle joint angle was statistically less after the treatment than before the taping treatment, and E2 (t = -2.343, p = .032) At E3 (t = -4.531, p = .000), the angle of the hip joint was statistically large. And after the ankle joint taping treatment, the medial/lateral COP movement after the ankle joint taping treatment was statistically large in the P3 phase of throwing the opponent (t = 2.670, p = .016), and the anterior/posterior COP movement showed a statistically small number in the P1 phase where the opponent was tilted (t = 2.846, p = .011). Therefore, it was suggested that judo athletes who use thighs as a special technique should be used considering the movement function of the support joint and the range of movement of the COP caused by tapping of the ankle joint.

An Experimental Study on Performance of Vapor Compression Refrigeration Cycle with Al2O3 nano-particle (Al2O3 나노 입자를 적용한 증기 압축 냉동 사이클의 성능)

  • Kim, Jeongbae;Lee, Kyu-Sun;Lee, Geunan
    • Journal of Energy Engineering
    • /
    • v.24 no.4
    • /
    • pp.124-129
    • /
    • 2015
  • An experimental study was performed estimating COP(Coefficient of Performance) of air-conditioning cycle using inverter scroll compressor with and without $Al_2O_3$ nano particle. All experiments were done for various compressor speeds from 1000~4000 rpm and used the inverter controller called CANDY to change the compressor rpm. The air-conditioning cycle components in the apparatus were used as same with components of YF hybrid car. To estimate the COP, this study measured the temperature and pressure at inlets and outlets of compressor, condenser, and evaporator. And also measured the compressor input power using Powermeter. Through the experiments, the maximum error to estimate COP was shown about ${\pm}6.09%$ at 3500rpm. The COP of refrigeration cycle with $Al_2O_3$ nano-particle was similar with that of the base cycle without nano-particle between 1000~3000 rpm of the compressor speed. But, This study showed that the COP of the cycle with $Al_2O_3$ over 3000 rpm of the compressor speed was higher than that of the base cycle due to the higher heat transfer rate increased in the evaporator from the higher oil flow rate inside the cycle as well known. Those results can be used the basic and fundamental data to design the air-conditioning cycle using inverter scroll compressor with $Al_2O_3$ nano particle.

A Study on the Cascade Hybrid Cooling/Refrigeration Cycle Equipped With Intercooler and Air-Cooled Condenser in Series (인터쿨러와 공랭식 응축기를 동시에 사용하는 냉방-냉동 겸용 캐스케이드 사이클에 대한 연구)

  • Kim, Nae-Hyun
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.20 no.7
    • /
    • pp.353-362
    • /
    • 2019
  • Thermodynamic analysis of cascade refrigeration systems has attracted considerable research attention. On the other hand, a system evaluation based on thermodynamic analyses of the individual parts, including the evaporator, condenser, intercooler, expansion valve, etc., has received less attention. In this study, performance analysis was conducted on a cascade refrigeration system, which has an individual cooling and refrigeration evaporator, and equips the intercooler and air-cooled condenser in a series in a lower cycle. The thermo-fluid design was then performed on the major components of the system - upper condenser, lower condenser, cooling evaporator, refrigeration evaporator, intercooler, compressor, electronic expansion valve - of 15 kW refrigeration, and 8 kW cooling capacity using R-410A. A series of simulations were conducted on the designed system. The change in outdoor temperature from 26 C to 38 C resulted in the cooling capacity of the lower evaporator remaining approximately the same, whereas it decreased by 9% at the upper evaporator and by 63% at the intercooler. The COP decreased with increasing outdoor temperature. In addition, the COP of the cycle with the intercooler operation was higher that of the cycle without the intercooler operation. Furthermore, the increase in the upper condenser size by two fold increased the upper evaporator by 4%. On the other hand, the lower evaporator capacity remained the same. The COP of the upper cycle increased with increasing upper condenser size, whereas that of the lower cycle remained almost the same. When the size of the lower condenser was increased 2.8 fold, the intercooler capacity increased by 8%, whereas those of upper and the lower evaporator remained approximately the same. Furthermore, the COP of the lower cycle increased with an increase in the lower condenser. On the other hand, the change of the upper condenser was minimal.

Effect of Balance before and after Impact on the Velocity and Angle of Golf Club during Driver Swing (골프 드라이버 스윙 시 임팩트 전·후 신체 균형성이 클럽헤드의 속도와 각도에 미치는 영향)

  • Ryu, Ji-Seon;Kim, Tae-Sam
    • Korean Journal of Applied Biomechanics
    • /
    • v.21 no.4
    • /
    • pp.411-420
    • /
    • 2011
  • The purpose of this investigation was to determine whether correlations exist between balance and impact velocity, angular position, and maximum velocity of a club during drive swing. Twelve skilled golfers were recruited in this study. They were asked to perform ten swing trials and two trials were selected for analysis. Balance parameters were calculated via the force platform while kinematic variables were determined by using the Qualisys system. The results of the present study demonstrated that the average of COP velocity was faster in the medio-lateral direction rather than the anterio-posterior direction. Also, left foot's COP velocity and free torque were greater than the right foot's before impact. The range of the right foot's COP in the anterio-posterior direction before impact were correlated with the club velocity and angular position at impact. There was a negative correlation between the left foot's COP velocity before the impact and the velocity at impact. Additionally, the range and RMS of the left foot's free torque affected on the club angular position at impact and the maximum velocity at release, respectively. Finally, a negative correlation existed between the range of the right foot's free torque after the impact and club's maximum velocity at release.

Analysis on Cooling and Heating Performance of Water-to-Water Heat Pump System for Water Source Temperature (물-물 수온차 히트펌프 시스템의 원수온도에 따른 성능 특성 분석)

  • Park, Tae Jin;Cho, Yong;Park, Jin-Hoon
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 2010.06a
    • /
    • pp.169.2-169.2
    • /
    • 2010
  • The research assesses the performance of the water-to-water heat pump system installed in Cheongju water treatment plant for cooling and heating ventilation. In summer season monthly averaged COP is ranged from 3.85 to 4.56 according to the water source temperature, and the performance is increased as the raw water temperature is dropped. While, heating performance is increased for the high temperature water source, and the monthly averaged COP is changed from 2.92 to 3.82. The correlation of the water source temperature and the heat pump performance shows a linear tendency by the simple regression of average data. In heating, the COP of heat pump system linearly rises according to the water source temperature. In comparison, the COP in cooling linearly reduces as the raw water temperature is raised. The goodness of fit at the simple regression shows the coefficient of determination 82% in cooling, 46% in heating. The electric cost of water-to-water heat pump is reduced by 40% compared to that of air source heat pump.

  • PDF

CopA3 peptide from Copris tripartitus induces apoptosis in human leukemia cells via a caspase-independent pathway

  • Kang, Bo-Ram;Kim, Ho;Nam, Sung-Hee;Yun, Eun-Young;Kim, Seong-Ryul;Ahn, Mi-Young;Chang, Jong-Soo;Hwang, Jae-Sam
    • BMB Reports
    • /
    • v.45 no.2
    • /
    • pp.85-90
    • /
    • 2012
  • Our previous study demonstrated that CopA3, a disulfide dimer of the coprisin peptide analogue (LLCIALRKK), has antibacterial activity. In this study, we assessed whether CopA3 caused cellular toxicity in various mammalian cell lines. CopA3 selectively caused a marked decrease in cell viability in Jurkat T, U937, and AML-2 cells (human leukemia cells), but was not cytotoxic to Caki or Hela cells. Fragmentation of DNA, a marker of apoptosis, was also confirmed in the leukemia cell lines, but not in the other cells. CopA3-induced apoptosis in leukemia cells was mediated by apoptosis inducing factor (AIF), indicating induction of a caspase-independent signaling pathway.