• 제목/요약/키워드: CO Alarm

검색결과 134건 처리시간 0.027초

효과적인 Alarm System 개발 (Development of Effective Alarm System)

  • 박동호;민병운;김정한;최항섭;이승재
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2005년도 제36회 하계학술대회 논문집 A
    • /
    • pp.507-509
    • /
    • 2005
  • This paper introduce about development of effective alarm system to apply to power system. This system includes index-components that display alarm information. It was changed color or position, value, etc by operator's tuning. According to use this system, User can not only perform easily a series of alarm analysis, but also can deal with custom system for only user.

  • PDF

연기/CO 및 연기/열 복합형 IoT 멀티 화재 감지기의 화재감지실험 연구 (A Study on Fire Alarm Test of IoT Multi-Fire Detector combined Smoke/CO and Smoke/Temperature Sensors)

  • 손근식;소수현
    • 한국재난정보학회 논문집
    • /
    • 제17권2호
    • /
    • pp.236-244
    • /
    • 2021
  • 연구목적: 연기/CO/열 복합형 화재감지기와 무선 IoT통신을 결합한 IoT 멀티화재감지기를 개발하고 화재감지 실험을 통하여 연기/CO/열 복합형 IoT 멀티화재감지기의 화재감지성능을 확인하는 것을 목적으로 한다. 연구방법: 연기/CO 복합형 과 연기/열 복합형의 IoT 멀티화재감지기를 연기발생기와 면 심지 연소를 통하여 화재감지성능을 실험하였으며, 화제 신호를 발하는 기준을 확인하였다. 연구결과: 연기/CO 복합형 IoT 멀티 화재감지기는 면심지 연소 실험에서 화재를 감지하였으나 연기발생기 실험에서는 화재를 감지하지 않았다. 반면 연기/열 복합형 IoT 멀티 화재감지기는 두 실험 모두 화재를 감지하지 않았다. 결론: 연기/CO 복합형 IoT 멀티화재감지기는 CO가 포함된 연기만을 감지하였으며, 연기/열 복합형 IoT 멀티 화재감지기는 열의 부족에 의해 화재를 잠지하지 않았다. 이와 같은 결과로 개발된 IoT 멀티 화재감지기는 면심지 연소 실험과 연기발생기 실험을 통해 2가지 센서의 기준값 이상 신호를 검출하여야 화재 신호를 발한다는 것을 확인하였다.

자동화재탐지설비와 휴대용비상조명등의 연동에 대한 연구 (The study of Connection Emergency lantern with Fire Alarm System)

  • 전중함;이상화;권오수
    • 한국화재소방학회:학술대회논문집
    • /
    • 한국화재소방학회 2008년도 춘계학술논문발표회 논문집
    • /
    • pp.108-111
    • /
    • 2008
  • Emergency lantern is an escape equipment of fire fighting. This equipment of obligation installation in buildings. But, We cast doubt on this equipment's reliability. Therefor we have need to study of this equipment's reliability. This paper research general emergency lantern for up grade reliability. For connection to fire alarm system, alarm for get lost general emergency lantern, and pilot lamp for interruption of electric power, and charge to rechargeable battery in general emergency lantern from fire alarm system. Then view very good result in reliability.

  • PDF

배전운영 시스템에서의 ZeroMQ와 알람 정보를 이용한 운영기능 관리 시스템 (Application Management System with ZeroMQ and Alarms in Distribution Management System)

  • 김필석;강호영;임일형;박종호;신용학
    • 전기학회논문지
    • /
    • 제64권8호
    • /
    • pp.1161-1167
    • /
    • 2015
  • Distribution Management System(DMS) ienhancing distribution automation system-based operation efficiency is an optimized system by various operational applications in a distribution network. DMS employs various applications like topology reconfiguration, volt/var control, and restoration at events such as overload, voltage violation, and a fault in a distribution system. An operation efficiency to employ multi-applications as restoration with short-term load forecasting is higher than a performance by a single application; and the applications are accomplished by an operator’s control. Applications’ combination is determined by various alarm information which means critical issues in order to operate a distribution system. Thus, this paper proposes an application management system which can configure application combination, control applications depending on alarm information and check their performance condition. The proposed application management system can be customized by operator easily and have high operation efficiency and reliability because it is worked by reviewed alarm information from operator.

자동화재탐지설비의 신뢰성 개선에 관한 연구 (Research on the Reliability Improvement of Automatic Fire Alarm System)

  • 손영진;이영일;이상현
    • 한국화재소방학회논문지
    • /
    • 제22권4호
    • /
    • pp.42-49
    • /
    • 2008
  • 본 연구에서는 기존의 자동화재탐지설비의 오동작(비화재보, 실보)과 빈번한 오동작으로 인한 전원의 차단 등의 문제점을 해결하고 보다 높은 신뢰성을 갖는 자동화재탐지설비를 구성하기 위한 방안을 제시한다. 제안된 방식은 다중센서를 이용한 마이크로프로세서-기반의 디지털 제어시스템으로서 화재 시 발생되는 여러 가지 연소생성물을 감지하기 위해서 열, 연기, CO 센서 등을 복합적으로 사용한다. 이와 같은 방식에 따라 자동화재탐지설비의 오동작 발생 가능성을 줄인 화재감지시스템을 구성하였고, 다중센서 화재감지장치의 화재 감지 및 판별 알고리즘에 의해서 화재발생의 여부를 디지털 제어시스템에 의해서 신뢰도 높게 판단함을 실제 시험을 통해 검증하였다. 실제 화재감지시스템을 구성하였고, 화재시험을 통해서 제안 된 방식의 향상된 신뢰도를 검증하였다.

A Development of Assessment Model for Maintenance of Type R Fire Alarm System in the Building

  • Lee, Su-Kyung;Yoo, Sang-Bin;Nam, Yang-Won
    • 한국화재소방학회:학술대회논문집
    • /
    • 한국화재소방학회 1997년도 International Symposium on Fire Science and Technology
    • /
    • pp.633-640
    • /
    • 1997
  • Type R fire alarm is required intelligent buildings and height buildings which was based on automatic system. But in Korea, maintenance of fire alarm system is very poor. In this study, we developed assessment model for the type R fire alarm system which was assessed by using 96 checklist items. The assessment model was tested through the actual 4 buildings with type R fire alarm system. It is shown that present model can be applied for the assessment of all buildings through the examination of the suitability of assessment model by actual assessment. Also, it was made easily fire manager to carry out checklist for type R fire alarm system in buildings.

  • PDF

무선 감응식 주택 단독 화재 경보 시스템 개발 (Development of a Single Fire Alarm System of House Based on Wireless Communication)

  • 박현호;조성진;박병화;허정훈;고윤석
    • 한국전자통신학회논문지
    • /
    • 제13권5호
    • /
    • pp.1017-1022
    • /
    • 2018
  • 본 논문에서는 주택 내의 단독 화재경보기들이 무선통신을 통해 상호 화재 정보를 공유함으로서 심야 시간대의 화재 인지력 저하 문제, 방 간 격벽으로 인한 경보 신호 감쇄 문제를 해소할 수 있는 무선 감응식 주택 단독 화재경보기를 개발하였다. 무선 감응식 화재경보기는 온도 센서와 가스 센서를 기반으로 온도와 $CO_2$ 농도를 감시, 주택의 화재를 감지하고 무선 송수신 모듈 등을 이용하여 다른 방의 단독 무선 경보기들에게 화재 경보를 전송함으로서 신속하고 정확한 화재인지가 가능하도록 설계되었다. 아두이노를 주제어장치로 하는 3개의 무선 감응식 단독화재 경보기의 시작품들이 제작되었으며, 온도 및 가스 시험에서 정확하게 동작함으로서 그 유용성을 확인하였다.

A Study on Loading Arm Envelope and Alarm Setting according to Ship Movement

  • Choi, Byoung-Yeol;Jo, Hyo-Jae;Choi, Han-Sik;Choi, Dong-Eon
    • Journal of Advanced Research in Ocean Engineering
    • /
    • 제4권3호
    • /
    • pp.115-123
    • /
    • 2018
  • This study was carried using the new approach method to design appropriately the Loading Arm length and the alarm setting according to ship movements on Loading and Unloading marine Berth. The quasi-static mooring analysis was performed to estimate 110,000DWT ship's movements based on environmental conditions such as wind, current and wave. The mooring motion of the ship is very important to determine the loading arm scope, and in this case, the operation condition is performed on the ship without considering the damaged condition of the mooring line because the ship movement in case of damage is larger than intact, and all operations are stopped, the loading arm being released due to control system. From the result of mooring analysis, motion displacements, velocities and accelerations were simulated. They were used to simulate the maximum drifting speeds and distances. The maximum drifting speeds were checked to be satisfied within drifting speed limits. The total maximum drifting distances were simulated with alarm steps of the new approach method. Finally, the loading arm envelopes using the total maximum drifting distances were completed. Therefore, it was confirmed that the new approach method for loading arm envelopes and alarm settings was appropriate from the above results. In the future, it will be necessary to perform the further advanced dynamic mooring analysis instead of the quasi-static mooring analysis and to use the precise computer program analysis for various environments and ship movement conditions.

건축물내 일산화탄소 경보기 설치기준에 관한 연구 (A Study on the Standard for Installation of Carbon Monoxide Detector in a Building)

  • 강승규;최경석
    • 한국가스학회지
    • /
    • 제12권4호
    • /
    • pp.1-7
    • /
    • 2008
  • 최근 5년간 국내 가스사고 중 CO중독사고는 사망 36명, 부상 79명이 발생하였으며, 전체 가스 사고에 비해 인명피해율이 8배나 높게 나타나고 있다. 이러한 CO중독사고의 대부분이 노후 가스보일러 및 다중 가스 사용시설의 배기통 불량에 의한 가스누출사고로 조사되고 있다. 본 연구에서는 실험을 통해 건축물 내 보일러실의 배기통 불량에 의한 CO가스의 누출확산 메커니즘을 해석하였다. 배기통에서 누출된 CO 가스는 건축물 내부의 천정부근에서 가장 높은 농도분포를 보인다. 또한 CO경보기 설치 실험을 통해서 천정부근의 CO경보기가 가장먼저 작동하고, $30{\sim}40$분 경과한 후에 바닥 및 중간에 설치된 경보기가 작동하는 것을 확인하였다. 본 연구를 통해 CO경보기의 적정 설치위치를 확인하였으며, 이 결과를 토대로 건출물내 CO경보기 설치위치를 제안하였다.

  • PDF