• Title/Summary/Keyword: CM-wire

Search Result 252, Processing Time 0.024 seconds

Design of a Compact Antenna for DTV Reception (DTV수신용 소형 안테나 설계)

  • Kim, Tae Yong;Lee, Jong-Ig
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 2015.10a
    • /
    • pp.73-74
    • /
    • 2015
  • In this paper, a digital terrestrial TV reception antenna which can be applied to the fade zone was designed and investigated. The proposed antenna was configured for a wire antenna structure with $16cm{\times}14cm$, and the antenna parameters are calculated by using the MoM method. The proposed antenna can be used to the receiver for domestic digital broadcast in UHF.

  • PDF

The Design and Fabrication of SRAM Modules Surface Mounted on Multilayer Borads (다층 기판 위에 표면실장된 SRAM 모듈 설계 제작)

  • Kim, Chang-Yeon;Jee, Yong
    • Journal of the Korean Institute of Telematics and Electronics A
    • /
    • v.32A no.3
    • /
    • pp.89-99
    • /
    • 1995
  • In this paper, we ecamined the effect that MCM-L technique influencess on the design and fabrication of multichip memory modules in increasing the packing desity of memory capacity and maximizing its electrical characteristics. For that purpose, we examined the effective methods of reducing the area of module layout and the wiring length with the variation of chip allocation and the number of wiring layers. We fabricated a 256K${\times}$8bit SRAM module with eight 32K${\times}$8bit SRAM chips. The routing experiment showed that we could optimize the area of module layout and wiring length by placing chips in a row, arranging module I/O pads parallel to chip I/O pads, and equalizing the number of terminal sides of module I/O's to that of chip I/O's. The routing was optimized when we used three wire layers in case of one sided chip mounting or five wire layers in case of double sided chip mounting. The fabricated modules showed 18.9 cm/cm$^{2}$ in wiring density, 65 % in substrate occupancy efficiency, and module substrate and functionally tested to find out the module working perfectly.

  • PDF

Development of a Pepper Removal Mechanism for a Red-Pepper Harvester (I)- Size Reduction of the Pepper Removal Mechanism and Improvement of Pepper Recovery Ratio - (고추수확기의 탈실장치 개발 (I) - 탈실장치의 소형화와 회수율의 제고 -)

  • 이종호;박승제;이중용
    • Journal of Biosystems Engineering
    • /
    • v.22 no.2
    • /
    • pp.177-188
    • /
    • 1997
  • A pepper harvester using a pair of counter rotating helically wound cylinders as a pepper removal mechanism has been developed. Pepper harvesting by machines under the customary cultivation practice was expected to lower land productivity, that most farmers were concerned about. As one way to compensate for loss in land productivity by machine harvest, experts on pepper cultivation suggested change of both varieties and plant density per area. From the view of machine design, their suggestion implied that distance between rows should be narrower and height of the pepper removal mechanism could be shorter. Experiments to improve perfect pepper recovery ratio and to reduce size of the pepper removal mechanism was accomplished. In order to be a economically feasible harvester, minimum pepper recovery ratio was required to be greater or equal to 80%. The research goal was achieved by both reducing the diameter of the wire-helices from 30 cm to 18 cm and increasing rotational speed of the wire-helices up to 425 rpm. The best perfect pepper recovery ratio was 82.3%. Validity of experiment design and interpretation on statistical analysis were discussed. To understand the pepper removal mechanism properly, a pepper removal theory based physics was judged to be necessary.

  • PDF

Highly Elastic Two-wire Transmission Line E-textile Band for Smart Wearable Circuit Formation (스마트 웨어러블 회로 구성을 위한 고신축성 이선 전송선형 전자섬유 밴드)

  • Roh, Jung-Sim
    • Journal of the Korean Society of Clothing and Textiles
    • /
    • v.46 no.2
    • /
    • pp.367-374
    • /
    • 2022
  • Herein, a highly elastic e-textile band with a two-wire transmission line was designed and fabricated for smart clothing applications. A conductive yarn with a very uniform low electrical resistance of 0.0357 Ω/cm was developed and used for the signal and ground lines. To control the elasticity of the e-textile band, spandex yarns were added in the warp direction during knitting and the tension was adjusted. As the length of the e-textile band increased, its RF performance deteriorated. Furthermore, the frequency corresponding to -3 dB S21 was lower in the 30% stretched band than in the unstretched band. For the e-textile bands with lengths 10, 50, and 100 cm, the frequencies corresponding to -3 dB S21 were 107.77, 24.56, and 13.02 MHz when not stretched, and 88.74, 22.02, and 12.60 MHz when stretched by 30%. The fabricated bands were flatter, more flexible, and more elastic than transmission line cables; thus, they can be easily integrated into wearables and smart clothing. However, to increase RF performance and achieve optimum utilization, future studies must focus on the fabrication of transmission lines with lower resistance and reduced distance between the signal and ground lines, and thus the number of transmission lines can be increased.

The Elementary Study on the Development of a Sensor for Measurement of Steel Corrosion by Transient Electro-Magnetic (TEM) Method (TEM 법에 의한 철근 부식 측정 센서 개발에 대한 기초 연구)

  • 이상호;한정섭
    • Journal of Ocean Engineering and Technology
    • /
    • v.15 no.1
    • /
    • pp.57-66
    • /
    • 2001
  • In order to measure steel corrosion in mortar by a transient electro-magnetic (TEM) Method, the development of the sensors have been studied. The sensors were made of enamelled wire with diameter of 0.25mm and Acril. The sensor configuration was used as a coincident loop type. The secondary electro motive force(EMF) was measured with SIROTEM III. The accelerator was equipped with the SIROTEM III. The accelerator permits the transmitter to turn off approximately 10~15 times faster than normal. The high resolution time series used for very shallow or high resistivity investigation was selected. The steels were embedded in mortar which were made from sand : cement : water ratio of 2 : 1: 0.5. The mortar specimen was 50cm long, 20cm wide and 10cm thick. To investigate steel corrosion in mortar, the sensors used were with 2$\times$2$cm^2$(3, 6, 9$\Omega$), 3$\times$3$cm^2$(3, 6, 9$\Omega$) and 6$\times$6$cm^2$(3, 6, 9$\Omega$). The obtained result obtained showed that the sensor 8(6$\times$6$cm^2$, 6$\Omega$) was the proper sensor for the measurement of steel corrosion in mortar.

  • PDF

A Compact Two-Wire Helical Antenna with an Open Stub for a T-DMB Antenna of Mobile Devices (단말기 T-DMB용 안테나로 사용될 수 있는 Open Stub를 가지는 소형 Two-Wire Helical 안테나)

  • Lee, Dong-Hyun;Park, Se-Hyun;Kim, Young-Eil;Park, Wee-Sang
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.18 no.2 s.117
    • /
    • pp.151-157
    • /
    • 2007
  • We have presented a compact two-wire helical antenna adopted an open stub in opposite to a feeding point, which is for a T-DMB antenna of mobile devices. By adjusting the length of the open stub or pasting a dielectric material on the open stub, the input impedance around 200 MHz, bands of the T-DMB, can be easily control, even though the total height of the antenna is less than 8 cm(0.053 $\lambda$ at 200 MHz). The operating mechanism of the antenna is explained by using equivalent circuits of two modes, an unbalanced mode and a balanced mode. Based on the analysis of the equivalent circuits, the effects of using the open stub are validated. Several proposed antennas have been fabricated and measured. One of the fabricated antennas has -10 dB impedance bandwidth of $196{\sim}204$ MHz(8 MHz) whose value covers one channel of the T-DMB(6 MHz). The measured $S_{21}$ of the antenna is -38.6 dB which is about 17 dB higher than that of a monopole antenna whose height is same with the proposed antenna.

Effects of the Tagging methods on the Growth and Survival of Abalone Juvenile, Haliotis discus hannai (전복, Haliotis discus hannai 치패의 성장과 생존에 미치는 표지의 영향)

  • Kim Bong Seok;Lee Yun Ho;Park Doo Won
    • Korean Journal of Fisheries and Aquatic Sciences
    • /
    • v.35 no.3
    • /
    • pp.282-288
    • /
    • 2002
  • This study was carried out to investigate the optimum tagging method of the abalone juvenile, Haliotis discus hannai in indoor culture system from May 2000 to January2001. Tagging methods were shell drilling, copper-wire tagging at the respiratory pore and nut gluing on the shell. The attachment rates of the shell showed high in the 2- and 3 cm bolt-nut tagged groups, about over $89.5\%$, whereas shell drilling groups on the shell were about $18.5\%$. The internal coating rates tagged with bolt-nut were over $96.6\%$, while those tagged with copper wire were less than $17.1\%$. Growths in the all marked and tagged experimental groups comparing with control groups were not significantly different (p>0,05). Survivals in all tagging groups except shell drilling and nut gluing groups in the 5 cm abalone were over $95\%, Accordingly, all juvenile groups were not affected by the tagging methods in terms of the growth and survival on the abalones. Based on these results, the micro bolt-nut tagging was the most effective method in abalone.

A Comparative Study on the Characteristics of the MWCNTs and PVP Added Nanofluids (다중벽 탄소나노튜브와 PVP가 첨가된 나노유체의 특성 비교 연구)

  • Park, Sung-Seek;Park, Youn-Cheol;Kim, Nam-Jin
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.23 no.1
    • /
    • pp.47-53
    • /
    • 2011
  • In this study, the characteristics of multi-walled carbon nanotubes added nanofluid were investigated. Sodium Dodecyl Sulfate, SDS, and Polyvinylpyrrolidone, PVP, were employed as the dispersant. SDS or PVP was added in pure water. And then, 0.0005, 0.001, 0.002, 0.003. 0.004, 0.005,0.01, and 0.02 vol% of CM-95 and CM-100 were dispersed respectively. The thermal conductivity and the viscosity were measured with a transient hot-wire instrument built for this study and the DV II+ Pro viscometer. The results showed that PVP had good thermal conductivity at 300 wt% and the thermal conductivity of CM-100 was better than that of CM-95. However, the viscosity of CM 100 was higher than that of CM 95.

Hot Wire Chemical Vapor Deposition of Hydrogenated Microcrystalline Silicon Films (열선 CVD법에 의한 수소화된 미세결정 실리콘 박막 증착)

  • Lee, Jeong-Chul;Kang, Ki-Whan;Kim, Seok-Ki;Yoon, Kyung-Hoon;Song, Jin-Soo;Park, I-Jun
    • Proceedings of the KIEE Conference
    • /
    • 1999.07d
    • /
    • pp.1928-1930
    • /
    • 1999
  • This paper describes on the growth of a ${\mu}c$-Si:H film on low cost substrate like glass by Hot Wire CVD method. The ${\mu}c$-Si:H film, prepared in 50mTorr pressure, $1800^{\circ}C$ wire temperature, and $H_2/SiH_4$ 10 showed three clear peaks. (111), (220), and (311) in X-ray spectroscopy. The crystallite size and crystalline volume fraction, calculated from Raman spectroscopy, was about 6nm and 70%, respectively. The FTIR transmission spectra of the film showed a different absorption peak with a-Si:H film around $2000-2100cm^{-1}$.

  • PDF

A Case of Esophageal Foreign Body Complicated by Pneumothorax (기흉을 초래한 식도이물)

  • 박상열;최진택;김광현;박찬일
    • Proceedings of the KOR-BRONCHOESO Conference
    • /
    • 1982.05a
    • /
    • pp.7.2-7
    • /
    • 1982
  • Foreign body in the esophagus is not uncommom in the otolaryngological field, but esophageal perforation followed by pneumothrax due to esophageal foreign body is very rare. Authors recently experienced such a case developed in 1 year old male baby. This baby had been treated at local clinic for 2 weeks prior to admission under the impression of U.R.I.. Thereafter foreign body in the esophagus (fine wire pin) with left pneumothorax was detected by chest X-ray and the body was transfered to our hospital. Closed chest tube was inserted on left and under the general anesthesia, foreign body was removed by esophagoscopy. He was discharged on 16th postoperative day uneventfully.

  • PDF