• Title/Summary/Keyword: CM-wire

Search Result 251, Processing Time 0.03 seconds

Endovaginal and Endorectal Surface Coils for in-ViVo Human MR Imaging and Spectroscopy (자궁경부암 진단용 MR 질내표면코일과 전립선암 진단용 MR 경직장표면코일의 제작 : 인체에서의 MR 영상과 MR 분광)

  • 문치웅;조경식
    • Journal of Biomedical Engineering Research
    • /
    • v.16 no.4
    • /
    • pp.481-491
    • /
    • 1995
  • Endovaginal and endorectal receiver only surface coils were designed for MR imaging (MRI) and $^1H$ MR spectroscopy (MRS) for the uterine cervix and the prostate. The shape of endovaginal coil wire was rectangular with round corner. Size of the coil wire was empirically determined for 7cm and 4cm along the long and short axis, respectively. The coil wire loop was supported by acryl handle and bent about $150^{\circ}$ at one side of the loop considering the average angle of the cervix to the vagina. We called this as a "spoon-type endovaginal coil". The wire of the endorectal coil was made of the flexible materials so that the wire loop became long elliptic shape by pushing the acryl handle into the plastic tube for the comfort of patients when the coil was inserted into the cervix. Then, the shape was maintained to be circle by popping out handle. Conventional spin echo (SE) and fast spin echo (FSE) sequences were used as 71 and 72 weighted imaging sequences, respectively. Matrix size was 128~$256{\times}256$. FOVs for surface coil and body coil were 14cm and 24cm, respectively. 3D volume localized in vivo $^1H$ MR spectroscopy of the human cervix and prostate was performed using PRESS or STEAM localization method with the following parameters . TR=3 sec, TE=135 msec for PRESS or 30 msec for STEAM, NEX=2, NS=48, Sl=2048, and SW=2500 Hz. Using home-built endovaginal and endorectal coils, excellent T1- and T2-images were obtained to visualize early cervical and prostate tumors. 3D volume localized in vivo IH MRS was useful to differentiate the cancerous tissue from the normal tissue.

  • PDF

Fundamental Study for Development of Pre-Heater for Warm In-Place Recycling in Korea (국내 현장중온재생공법의 프리히터 개발을 위한 기초연구)

  • Kim, Dae-Hun;Kim, Seung-Hoon;Kwon, Soo-Ahn;Kim, Yongjoo;Lee, Jaejun
    • International Journal of Highway Engineering
    • /
    • v.17 no.2
    • /
    • pp.31-37
    • /
    • 2015
  • PURPOSES : To design a pre-heater for warm in-place recycling equipment, three different heating systems were evaluated to determine their thermal efficiency. METHODS: In this study, a $30cm{\times}30cm{\times}15cm$ wheel-tracking specimen was used to measure the inner temperature as a function of the heating system. The inner temperature of the specimen was measured with a data logger at the surface, and at depths of 1cm, 2cm, 3cm, 4cm, and 5cm. To evaluate the thermal efficiency, the researchers used three different types of equipment, namely, IR, a heating wire, and a gas burner. RESULTS: The IR heating system exhibits a higher level of performance than the others to achieve the target temperature at a depth of 5cm in the specimen. The gas burner system was capable of heating the surface to a temperature of up to $600^{\circ}C$. The other types, however, cannot heat the surface up to 600. The thermal efficiencies were measured based on the laboratory conditions. CONCLUSIONS: To find the most effective system for application to the development of a pre-heater for warm in-place recycling, various systems (IR, heating wire, gas burner) were examined in the laboratory. As a result, it was found that the hot plate of a gas burner system provides the highest temperature at the surface of the asphalt but, of all the systems, the IR system provides the best internal temperature increase rate. Furthermore, a gas burner can age the asphalt binder of the surface layer as a result of the high temperature. However, the gas burner cannot attain the target temperature at 5cm. The IR system, on the other hand, is effective at increasing the internal temperature of asphalt.

A Study on the induced Current of Electro Explosive Device Bridge Wire under Electromagnetic Field (전자파환경에서 EED에 유기되는 전류에 관한 연구)

  • 김응조
    • Journal of the Korea Institute of Military Science and Technology
    • /
    • v.5 no.2
    • /
    • pp.116-122
    • /
    • 2002
  • Electro Explosive Devices can be susceptible to electromagnetic interference. When these components are exposed to external electromagnetic fields, it may cause to induce sufficient current to generate enough heat for an inadvertent detonation. It is almost impossible to monitor the event of firing throughout the electromagnetic environment test. The survivability of EED for hazards of electromagnetic radiation is investigated. A fiber optic sensor is installed near the bridge wire after removing explosive material in order to measure the induced current on the bridge wire. The length of lead-wire of the EED fabricated is around 15 cm.

A Study on the Sensing Function of Amorphous Magnetostrictive Wire (아몰퍼스 자왜 와이어의 센싱기능에 관한 연구)

  • 조남희;신용진;서강수;임재근;문현욱
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 1996.11a
    • /
    • pp.89-92
    • /
    • 1996
  • In this paper, we mention the study on the sensing function of amorphous magneto- striction wire with about 125${\mu}{\textrm}{m}$$\Phi$ in diameter. The wire in fabricated by using injection and quenching method under the high speed rotating water flow. The wire\`s compotion is (Fe$_{75}$ $Co_{25}$)$_{77}$Si$_{8}$B$_{15}$ , and generates sharp Matteucci voltage by large Barkhausen jump effect even the weak magnetic field. In this study, we don\`t use pick-up coil. Instead, we apply external magnetic field of 3.6Oe in the direction orthogonal to the wire. Then, we detect Matteucci voltage of 1.lmV to both side of 20cm amorphous-wire. Thus, we find that the fabricated wire has the function necessary as the high sensitive sensor material.l.al.l.

  • PDF

Characteristics of Bi2212 Round-wire Depending on Heat Treatment Condition (열처리조건에 따른 Bi-2212 라운드형 선재의 특성)

  • Lee Nam-Il;Jang Gun-Eik;Oh Sang-Su;Ha Dong-Woo;Kim Sang-Cheol
    • Progress in Superconductivity and Cryogenics
    • /
    • v.8 no.3
    • /
    • pp.1-4
    • /
    • 2006
  • The characteristics of Bi2212 round wire was systematically studied depending on different heat treatment conditions. Initial wire was drawn after routine PIT (Powder In Tube) process. The wire was divided into 3 pieces with 10 cm in length and 2.5 mm in diameter. 3 wires were pre-heat treated separately by different heat treatment schedules, heated in air and nitrogen atmosphere and centrifugally melted. Pre-heated wires were annealed at $845^{\circ}C$ for 40 hours in oxygen atmosphere. SEM results indicate that all pre-heated wires showed highly oriented microstructure. However the wire by centrifugally melted process showed higher density and better electric properties as compared with 2 other wires pre-heated in air and nitrogen atmosphere. The critical current of a centrifugally melted wire was about 18 A in 77 K.

A study on the Nano Wire Grid Polarizer Film by Magnetic Soft Mold (Magnetic soft mold를 이용한 나노 와이어 그리드 편광 필름 연구)

  • Jo, Sang-Uk;Chang, Sunghwan;Choi, Doo-Sun;Huh, Seok-Hwan;Jeong, Myung Yung
    • Journal of the Microelectronics and Packaging Society
    • /
    • v.21 no.2
    • /
    • pp.85-89
    • /
    • 2014
  • We propose the new fabrication method of a 70 nm half-pitch wire grid polarizer with high performance using magnetic soft mold. The device is a form of aluminium gratings on a PET(Polyethylene phthalate) substrate whose size of $3cm{\times}3cm$ is compatible with a TFT_LCD(Tin Flat Transistor Liquid Crystal Display) panel. A magnetic soft mold with a pitch of 70 nm is fabricated using two-step replication method. As a result, we get a NWGP pattern which has 70.39 nm line width, 64.76 nm depth, 140.78 nm pitch, on substrate. The maximum and minimum transmittances of the NWGP at 800 nm are 75% and 10%, respectively. This work demonstrates a unique cost-effective solution for nanopatterning requirements in consumer electronics components.

Usefuless of Multi-functional Gastroduodenal Coil Catheter with Phantom (팬텀을 이용한 다기능 위.십이지장관 코일 카테타의 유용성 평가)

  • Lim, Jin-Oh;Kim, Tae-Hyung;Jung, Yang-Hwa;Choi, Won-Chan;Shin, Ji-Hoon;Song, Ho-Young
    • Journal of radiological science and technology
    • /
    • v.26 no.4
    • /
    • pp.21-26
    • /
    • 2003
  • To evaluate the newly designed gastroduodenal coil catheter:in-vitro test. The coil catheter that we made in our laboratory was 150 cm. The coil that is made of stainless steel wire was composed 1.3 mm inner diameter and this coil spring was covered with heat-shrinkable polyethylene tube. To measure the length under fluorocopy, 8 radiopaque marks were attached at 5 cm, 10 cm, 11 cm, 12 cm, 13 cm, 14 cm, 15 cm, 20 cm apart from distal end of the catheter and 6, 2, 1 pores were made at 7 cm, 13 cm, 19 cm apart from the distal end. Radio-opacity and the amount of injected contrast was investigated in formerly used 5 Fr. vessel catheter, which is possible in measuring length, and newly designed coil catheter. Film density was tested for radio-opacity with autodensitometer. For measuring the volume of injected salin, the catheter was located in the acryl box(26 cm, 3 cm, 16 cm) that divided into 4 chambers. After injection 50 cc of contrast with autoinjector, the contrast's quantity in each chamber was measured with and without over the guide wire. Radio-opacity was 0.51 in 5 Fr. vessel catheter, 0.31 in newly made catheter. The amount of injected contrast was measured. In case of 5 Fr. vessel catheter, the amount was 99.5% from the distal part, there was no difference between with and without the guide wire. Otherwise, using a coil catheter, the pacentage the ejected saline was 1.17%, 18.8%, 41.8%, 38.2% from the distal part with the guide wire, 19.5%, 32.6%, 27.7%, 20.3% without the guide wire. Compare with formerly established catheter, this new coil catheter is easy to measure the length thanks to easy confirming under fluoroscopy and excellent in injecting contrast. Therefore, newly designed gastrointestinal catheter seems to be useful in gastrointestinal intervention procedure.

  • PDF

An Experimental Study on Flexural Behavior of One-Way Concrete Slabs Using Structural Welded Wire-Fabric (구조화 용접철강을 사용한 일방향 슬래브의 휨 거동에 관한 실험적 연구)

  • 허갑수;윤영호;양지수;김석중;정헌수
    • Magazine of the Korea Concrete Institute
    • /
    • v.6 no.2
    • /
    • pp.169-179
    • /
    • 1994
  • Recently the construction of residential buildings faces many difficulties due to the shortage of building materials and works. Simplifying the stage of processing and assembling reinforcing rods and increasing the efficiency of them in reinforced concrete construction can be used to settle the difficulties. In the respect, structural wire-fabric and loop wire-fabric is utilized. The purpose of this study, on condition of being $210kg/cm^2$ concrete strength, is to analyze the structural and flexural properties of one-way concrete slabs by testing with different reinforcing type, tensile steel ratio based with minimum steel ratio, boundary condition and splice length which affect the maximum width of crack and ductility factor. From the test results, the ductility factor is approved that the slabs using deformed bar were much better than that using wire-fabric, and 30D of splice length was appropriate in the slabs as splice length. In the control of the maximum crack width the slabs using wire-fabric and loop wire-fabric were much better than that using deformed bar.

The Coupling Characteristics of THz Electromagnetic Wave using Copper Wire Waveguide (구리선 도파로를 이용한 THz 전자기파의 결합 특성)

  • Jeon, Tae-In;Ji, Young-Bin
    • Korean Journal of Optics and Photonics
    • /
    • v.17 no.3
    • /
    • pp.290-295
    • /
    • 2006
  • The coupling between copper wire and a THz electromagnetic wave is one of the important factors to build up the magnitude and spectrum of a THz wave. We measured a I THz spectrum range THz pulse into a $480{\mu}m$ diameter and 23cm long copper wire waveguide. We measured THz pulses up to $275{\mu}m$ air gap between the end of the copper wire and transmitter or receiver chips. The coupling sensitivity of the transmitter is 3 times bigger than that of the receiver. The THz pulses propagated to air by the end of the receiver-side copper wire tip acting as a transmitter antenna. We confirmed that the THz field concentrates near the copper wire surface by opening the pin hole to the copper wire waveguide.

An Experimental Study on flexural behavior of One -Way Concrete Slabs using Structural Weled Wire - Fabric (구조용 용접철망을 사용한 일방향 슬래브의 휨거동에 관한 실험적 연구)

  • 허갑수;윤영호;양지수;김석중;정헌수
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 1993.10a
    • /
    • pp.226-231
    • /
    • 1993
  • This research is undertaken to the flexural strength, failure mode and ductile capacity of one way concrete slabs, with without splices, reinforcement with Wire-Fabric. Test results are as fallows : (1) Crack of the simple slabs is occured at a position of transerve wire and sntirely crack interval of the fixed slabs is taken place about 20cm, (2)Maximum load of slab with splices has showed almost similar to that of slab without splices, but ductile capacity increased according to rising of splices, (3) Ductile capacity of slab with Deformed Bar is higher 1.44 times than that of slab with Wire-Fabric, and it is higher 3.74 times than that of slab with Loop-wire fabric, but that of specimens of using Wire-Fabric is average 4.6.

  • PDF