• 제목/요약/키워드: CM Function

검색결과 1,500건 처리시간 0.024초

Meromorphic Function Sharing Two Small Functions with Its Derivative

  • Liu, Kai;Qi, Xiao-Guang
    • Kyungpook Mathematical Journal
    • /
    • 제49권2호
    • /
    • pp.235-243
    • /
    • 2009
  • In this paper, we deal with the problem of uniqueness of meromorphic functions that share two small functions with their derivatives, and obtain the following result which improves a result of Yao and Li: Let f(z) be a nonconstant meromorphic function, k > 5 be an integer. If f(z) and g(z) = $a_1(z)f(z)+a_2(z)f^{(k)}(z)$ share the value 0 CM, and share b(z) IM, $\overline{N}_E(r,f=0=F^{(k)})=S(r)$, f${\equiv}$g, where $a_1(z)$, $a_2(z)$ and b(z) are small functions of f(z).

A RESULT ON A CONJECTURE OF W. LÜ, Q. LI AND C. YANG

  • Majumder, Sujoy
    • 대한수학회보
    • /
    • 제53권2호
    • /
    • pp.411-421
    • /
    • 2016
  • In this paper, we investigate the problem of transcendental entire functions that share two values with one of their derivative. Let f be a transcendental entire function, n and k be two positive integers. If $f^n-Q_1$ and $(f^n)^{(k)}-Q_2$ share 0 CM, and $n{\geq}k+1$, then $(f^n)^{(k)}{\equiv}{\frac{Q_2}{Q_1}}f^n$. Furthermore, if $Q_1=Q_2$, then $f=ce^{\frac{\lambda}{n}z}$, where $Q_1$, $Q_2$ are polynomials with $Q_1Q_2{\not\equiv}0$, and c, ${\lambda}$ are non-zero constants such that ${\lambda}^k=1$. This result shows that the Conjecture given by W. $L{\ddot{u}}$, Q. Li and C. Yang [On the transcendental entire solutions of a class of differential equations, Bull. Korean Math. Soc. 51 (2014), no. 5, 1281-1289.] is true. Also we exhibit some examples to show that the conditions of our result are the best possible.

게이트 전극 물질이 a-IGZO 박막트랜지스터의 전기적 특성에 미치는 영향 (Effect of gate electrode material on electrical characteristics of a-IGZO thin-film transistors)

  • 오현곤;조경아;김상식
    • 전기전자학회논문지
    • /
    • 제21권2호
    • /
    • pp.170-173
    • /
    • 2017
  • 본 연구에서는 Al, Mo 및 Pt 금속 물질을 a-IGZO 박막트랜지스터의 게이트 전극으로 플라스틱 기판 위에 형성하여 제작하고, 게이트 물질에 따른 전기적 특성을 측정하였다. Al 게이트 전극에 비해 Pt 게이트 전극을 사용한 박막트랜지스터의 문턱전압은 -4.1V에서 -0.3 V까지 감소하였고, 전하이동도는 $15.8cm^2/V{\cdot}s$에서 $22.1cm^2/V{\cdot}s$ 로 향상되었다. 게이트 전극에 따른 박막트랜지스터의 문턱전압 이동은 전극의 일함수와 채널층의 페르미 에너지 차이로 인한 영향이라는 것을 확인 할 수 있었다. 또한, 채널 물질의 페르미 에너지를 고려하였을 경우에 Pt 게이트 전극이 박막트랜지스터의 전기적 특성 면에서 적합한 물질로 확인되었다. 추가적으로 Mo 게이트 전극을 사용한 박막트랜지스터에 대한 특성도 본 논문에서 다룬다.

Hydrodynamic fish modeling for potential-expansion evaluations of exotic species (largemouth bass) on waterway tunnel of Andong-Imha Reservoir

  • Choi, Ji-Woong;An, Kwang-Guk
    • Journal of Ecology and Environment
    • /
    • 제40권2호
    • /
    • pp.125-135
    • /
    • 2016
  • Background: The objectives of this study were to establish a swimming capability model for largemouth bass using the FishXing (version 3) program, and to determine the swimming speed and feasibility of fish passage through a waterway tunnel. This modeling aimed to replicate the waterway tunnel connecting the Andong and Imha Reservoirs in South Korea, where there is a concern that largemouth bass may be able to pass through this structure. As largemouth bass are considered an invasive species, this spread could have repercussions for the local environment. Results: Flow regime of water through the waterway tunnel was calculated via the simulation of waterway tunnel operation, and the capability of largemouth bass to pass through the waterway tunnel was then estimated. The swimming speed and distance of the largemouth bass had a positive linear function with total length and negative linear function with the flow rate of the waterway tunnel. The passing rate of small-size largemouth bass (10-30 cm) was 0%at a flow of $10m^3/s$ due to rapid exhaustion from prolonged upstream swimming through the long (1.952 km) waterway tunnel. Conclusions: The results of FishXing showed that the potential passing rate of large size largemouth bass (>40 cm) through the waterway tunnel was greater than 10%; however, the passage of largemouth bass was not possible because of the mesh size ($3.4{\times}6.0cm$) of the pre-screening structures at the entrance of the waterway tunnel. Overall, this study suggests that the spread of largemouth bass population in the Imha Reservoir through the waterway tunnel is most likely impossible.

Pylorus-Preserving Gastrectomy for Gastric Cancer

  • Oh, Seung-Young;Lee, Hyuk-Joon;Yang, Han-Kwang
    • Journal of Gastric Cancer
    • /
    • 제16권2호
    • /
    • pp.63-71
    • /
    • 2016
  • Pylorus-preserving gastrectomy (PPG) is a function-preserving surgery for the treatment of early gastric cancer (EGC), aiming to decrease the complication rate and improve postoperative quality of life. According to the Japanese gastric cancer treatment guidelines, PPG can be performed for cT1N0M0 gastric cancer located in the middle-third of the stomach, at least 4.0 cm away from the pylorus. Although the length of the antral cuff gradually increased, from 1.5 cm during the initial use of the procedure to 3.0 cm currently, its optimal length still remains unclear. Standard procedures for the preservation of pyloric function, infra-pyloric vessels, and hepatic branch of the vagus nerve, make PPG technically more difficult and raise concerns about incomplete lymph node dissection. The short- and long-term oncological and survival outcomes of PPG were comparable to those for distal gastrectomy, but with several advantages such as a lower incidence of dumping syndrome, bile reflux, and gallstone formation, and improved nutritional status. Gastric stasis, a typical complication of PPG, can be effectively treated by balloon dilatation and stent insertion. Robot-assisted pylorus-preserving gastrectomy is feasible for EGC in the middle-third of the stomach in terms of the short-term clinical outcome. However, any benefits over laparoscopy-assisted PPG (LAPPG) from the patient's perspective have not yet been proven. An ongoing Korean multicenter randomized controlled trial (KLASS-04), which compares LAPPG and laparoscopy-assisted distal gastrectomy for EGC in the middle-third of the stomach, may provide more clear evidence about the advantages and oncologic safety of PPG.

의복패턴상에서 직물의 각도 변화에 따른 봉합강도 (Seam-Strength as a Function of Angle of Bias on the Patterns)

  • 이명희;최석철
    • 한국의류학회지
    • /
    • 제21권4호
    • /
    • pp.710-717
    • /
    • 1997
  • An investigation made of fabric strength & elongation and the lock stitch seam strength & elongation by stitch density (N1.5; 26 stitches/3 cm, N2.0; 19 stitches/3 cm, N2.5; 14 stitches/3cm) depending on methods of. sample prepariation (angle variations of unseamed sample and overlapping way of seamed sample) It found maximum stitch density that results of the seam strength test was highist in each angle of bias. The results obstained were as follows: 1. As the results of fabric strength and elongation tests as a function of angle of bias, breaking strength were that warp and weft angles (0$^{\circ}$, 90$^{\circ}$) were much higher than bias angles (20$^{\circ}$, 30$^{\circ}$, 45$^{\circ}$, 60$^{\circ}$) . And otherwise breaking elongation were that 45$^{\circ}$ angle of bias were highest and were that the warp & weft way were lower. 2. As the results of the seam strength tests by the stitch density under samples of same angles, the maximum stitch density were those; under 0$^{\circ}$/0$^{\circ}$, 60$^{\circ}$/60$^{\circ}$:F1, F2-N2.0, F3-N1.5, under 20$^{\circ}$/20$^{\circ}$, 30$^{\circ}$/30$^{\circ}$, 45$^{\circ}$/45$^{\circ}$: F1-N2.5, F2-N2.0, F3-N1.5, under 90$^{\circ}$/90$^{\circ}$: F1, F2, F3-N1.5. 3. As the results of the seam strength tests by the stitch density under samples of symmetry angles, the maximum stitch density were those; under 20$^{\circ}$/-20$^{\circ}$, 30$^{\circ}$/-30$^{\circ}$, 60$^{\circ}$/-60$^{\circ}$: F1, F3-N1.5, F2-N2.0, under 45$^{\circ}$/-45$^{\circ}$: F1, F2-N2.0, F3-N1.5.

  • PDF

IMRT에 있어 Jaw Tracking 의 임상적 유용성 검증 (Verification of Clinical Usefulness of Jaw Tracking in IMRT)

  • 김진영;김기환
    • 한국방사선학회논문지
    • /
    • 제14권2호
    • /
    • pp.105-109
    • /
    • 2020
  • 세기조절방사선치료(IMRT)는 치료범위의 선량분포를 향상시키고 주변 정상조직을 보호한다는 점에서 두경부, 전립선, 뇌와 같은 부위에 널리 사용되고 있다. 그러나 이러한 세기조절방사선치료는 입체조형방사선치료에 비해 많은 방사선조사량으로 인해 누적선량이 증가하고 다엽콜리메이터의 누설선량이나 투과선량으로 인한 저선량이 증가하는 양상을 보인다. 이러한 누적선량이나 저선량의 증가는 악성 종양의 재발생율을 증가시키는 것으로 보고되고 있다. 본 논문에서는 뇌종양의 방사선치료에 있어 기존 선형가속기의 단점을 보완하고 다엽콜리메이터의 누설선량이나 투과선량을 줄이기 위해 개발된 Varian사의 TRUEBEAM 의 Jaw Tracking 기능의 임상적인 유용성을 검증하고자 하였다. Jaw tracking 기능의 임상적 유용성을 검증하기 위해 Varian사의 Eclipse11을 이용하여 치료범위에서 1) Organ At Risk(OAR)에 2 cm 이상 떨어진 경우 2) OAR에 2 cm 이하로 떨어진 경우 3) OAR를 포함하는 경우 3 가지의 원본 치료계획을 만들고 이를 복사한 후, Smart LMC Version 11.0.31을 이용하여 Jaw tracking 기능을 사용한 치료계획을 만들었다. 비교는 두 치료계획 간의 Cumulative Dose Volume Histogram(DVH) 에서 OAR의 평균선량 및 최대선량의 차이를 통해 평가하였다. 두 치료계획 간의 DVH 비교 결과 PTV가 OAR에 2 cm 이상 떨어진 경우 두 치료계획 간의 차는 최대 0.5 % 차이, 2 cm 이하로 떨어진 경우 최대 0.6 % 차이, PTV가 OAR을 포함하는 경우 최대 2.3 % 차이를 가졌다. 이 결과에 의하면 OAR과 PTV 간의 거리가 가까워짐에 따라 인접해있는 OAR 평균선량 및 최대선량에 있어 두 치료계획간 차가 커짐을 알 수 있다. 따라서 Jaw Tracking을 사용한 경우 일관성 있게 선량 감소가 있고 표면선량이 증가하지 않으므로 임상적인 유용성을 검증할 수 있었다. 향후 본 연구결과를 토대로 뇌, 두경부, 전립선과 같은 부위에 방사선 치료 시 선량감소 정도에 대한 추가 연구를 진행하여 각 부위에 따른 Jaw Tracking의 임상적 유용성 검증이 가능할 것으로 사료된다.

유전체필름을 이용한 평행판검출기의 납 차폐물 두께변화에 대한 반응 (Response for Lead Block Thickness of Parallel Plate Detector using Dielectric Film)

  • 김용은;조문준;김준상;오영기;김진기;신교철;김정기;정동혁;김기환
    • 한국의학물리학회지:의학물리
    • /
    • 제17권1호
    • /
    • pp.1-5
    • /
    • 2006
  • 본 연구에서는 납 차폐물의 두께변화에 대한 반응을 알아보기 위하여 크롬으로 코팅된 전극을 사용한 FEP 유전체필름과, 그들 사이에 PTFE 유전체 필름을 삽입한 형태의 평행판 검출기를 제작하였다. 측정조건은 선원-팬텀표면 간의 거리 100 Cm, 조사면 크기 10x10 cm, 그리고 팬텀의 표면으로부터 깊이 5 cm 되는 지점과 10 cm 되는 지점에 유전체필름을 이용한 제작검출기와 Farmer형 전리함을 설치하고 6 MV, 10 MV X-선을 조사하였다. 차폐물은 조사면을 충분히 포함하도록 제작하여 측정순서에 따라 차례대로 Tray 위에 놓아서 두께변화에 대한 감쇄효과를 확인하고 두 검출기 간의 반응함수를 알고자 하였다. 차폐효과에 대한 두 검출기 간의 반응함수는 선량에 대하여 지수적으로 감소함을 확인할 수 있었다. 제작검출기와 비교검출기로 측정한 선형감쇄계수 ${\mu}(cm^{-1})$는 6 MV X-선으로 조사한 경 우 0.1414, 0.541이 었고, 10 MV X-선으로 조사한 경우 각각 0.1368, 0.5279로서 납 차폐물의 두께 변화에 의한 선형감쇄계수가 감소하는 경향을 확인할 수 있었으며 계산된 반응함수로부터 제작검출기는 전리함에 비해 상대적으로 매우 크게 반응하고 있음을 알 수 있었다. 제작검출기에서 측정한 선량값(R)과 전리함에서 측정한 선량값($D_r$) 간의 반응함수를 최적화 과정을 통하여 계산하였다. 이들 반응함수의 최적화 상수 값들은 고 에너지 X-선 크기에 비교적 무관한 경향을 보였다. 제작 검출기와 비교검출기 간의 최적화된 반응함수를 계산한 결과 6 MV X-선의 경우 1%, 10 MV X-선의 경우 4% 이내의 범위 내에서 측정된 선량이 일치함으로써 상대 선량계로서의 가능성을 확인하였다.

  • PDF

한국에서 노화에 따른 폐기능지표의 변화양상 (The Influence of Aging on Pulmonary Function Tests in Elderly Korean Population)

  • 이재명;김은정;강민종;손지웅;이승준;김동규;박명재;이명구;현인규;정기석
    • Tuberculosis and Respiratory Diseases
    • /
    • 제49권6호
    • /
    • pp.752-759
    • /
    • 2000
  • 연구배경 : 폐기능 검사는 민족과 인종 그리고 거주지역뿐만 아니라 연령에 따라서도 차이가 있는 것으로 알려져 있다. 그러나 대부분의 검사실에서 검사기기에 내장된 평균적 표준치를 기준으로 삼고 있는 실정이어서 노령인구에 대한 폐기능검사 표준을 조사할 필요가 있었다. 이에 건강한 노인을 대상으로 폐기능검사를 시행하여 연령증가에 따른 폐기능의 변화를 확인하고 이를 토대로 표준치를 제시하고자 하였다. 방법 : 65세 이상의 남녀 각 100명을 대상으로 폐기능검사를 시행하였다. 측정된 FVC, $FEV_1을 Windows용 SPSS 8.0 version을 이용하여 연령 및 사용하여 다중회기분석을 시행하였다. 노인들의 연령과 키를 현재까지 많이 쓰이고 있는 다중선형회기식으로 분석하여 저자들의 다중선형회기식과의 차이를 분석하였다. 결과 : 대상 200예 중 남자노인의 평균연령은 $71.5{\pm}5.1$세였고, 평균신장은 $163.5{\pm}6.20$cm 였다. 이들의 평균 FVC는 $3.42{\pm}0.48{\ell}$, 평균 $FEV_1$$2.71{\pm}0.39{\ell}$였다. 여자노인의 평균연령은 $72.0{\pm}5.1$세였고, 평균 신장은 $149.1{\pm}5.93$cm 였다. 이들의 평균 FVC는 $2.22{\pm}0.42{\ell}$ 였고, 평균 $FEV_1$$1.83{\pm}0.33{\ell}$였다. 단변수 분석에서 선형적 연관성을 보인 연령과 신장을 독립변수로 한 다중회귀식을 계산하였고 이를 기존의 다종선형회기식과 비교한 결과 $FEV_1$은 Morris등의 다중선형회기식에 의한 예측치가 실측치보다 낮게 예측되어 유의한 차이가 있었다(p<0.01). 결론 : 65세 이상의 정상노인에서 폐기능 검사를 시행한 결과 연령의 증가에 따라 폐기능이 통계적으로 의미있게 감소함을 확인하였다. 또한 이들의 폐기능 실측치를 다종선형회귀식을 도출하여 기존에 보고된 식들과 비교한 결과 기존의 다중선형회귀식이 한국노인의 표준을 대변할 수 없음을 증명하였다. 저자들의 다중선형회귀식은 노인 연령균에서 오차가 적어 한국노인의 폐기능을 예측하는데 유용할 것으로 기대되었다.

  • PDF

The Effects of Work Function of Metal in Graphene Field-effect Transistors

  • Bae, Giyoon;Park, Wanjun
    • 한국진공학회:학술대회논문집
    • /
    • 한국진공학회 2014년도 제46회 동계 정기학술대회 초록집
    • /
    • pp.382.1-382.1
    • /
    • 2014
  • Graphene field-effect transistors (GFET) is one of candidates for future high speed electronic devices since graphene has unique electronic properties such as high Fermi velocity (vf=10^6 m/s) and carrier mobility ($15,000cm^2/V{\cdot}s$) [1]. Although the contact property between graphene and metals is a crucial element to design high performance electronic devices, it has not been clearly identified. Therefore, we need to understand characteristics of graphene/metal contact in the GFET. Recently, it is theoretically known that graphene on metal can be doped by presence of interface dipole layer induced by charge transfer [2]. It notes that doping type of graphene under metal is determined by difference of work function between graphene and metal. In this study, we present the GFET fabricated by contact metals having high work function (Pt, Ni) for p-doping and low work function (Ta, Cr) for n-doping. The results show that asymmetric conductance depends on work function of metal because the interfacial dipole is locally formed between metal electrodes and graphene. It induces p-n-p or n-p-n junction in the channel of the GFET when gate bias is applied. In addition, we confirm that charge transfer regions are differently affected by gate electric field along gate length.

  • PDF