• Title/Summary/Keyword: CFL

Search Result 85, Processing Time 0.04 seconds

Compensation of temperature characteristics by frequency control of an electronic ballastfor a compact fluorescent lamp (콤팩트 형광램프용 전자식 안정기의 주파수 제어에 의한 온도보상)

  • Song, Sang-Bin;Gwark, Jae-Young;Yeo, In-Seon
    • The Transactions of the Korean Institute of Electrical Engineers B
    • /
    • v.48 no.1
    • /
    • pp.27-33
    • /
    • 1999
  • Compact fluorescent lamps are very sensitive to the variation of ambient temperature. This paper investigates the temperature characteristics of a 15[W] compact fluorescent lamp, and compensates the variation of light output by frequency control of its electronic ballast. Circuit parameters for the inverter of the electronic ballast are obtained by analyzing the R-L-C equivalent circuit for the inverter and the lamp. The optimum ratio of the two capacitance($C_1$/$C_2$), which are connected with the lamp in series and in parallel, respectively, is determined which consideration of the temperature variation within a range of 10~35[$^{\circ}C$]. As a result a value of 10 for the ratio is obtained at an operating frequency of 57[kHz], and with this value the frequency control works well for temperature compensation. Its validity is verified by investigating light output stabilization characteristics resulting from frequency control of the lamp at various temperatures.

  • PDF

Applications of Implicit Discontinuous Galerkin Method to Shallow Water Equations (불연속 갤러킨 음해법의 천수방정식 적용)

  • Lee, Haegyun;Lee, Namjoo
    • Journal of Korean Society of Coastal and Ocean Engineers
    • /
    • v.32 no.6
    • /
    • pp.569-574
    • /
    • 2020
  • Though the discontinuous Galerkin (DG) method has been developed and applied to shallow water equations mainly in explicit schemes, they have been criticized for the limitation in treatment of bottom friction terms and severe CFL conditions. In this study, an implicit scheme is devised and applied to some representative benchmark problems. The linear triangular elements were employed and the Roe numerical fluxes were adopted for convective fluxes. To preserve TVD property, the slope limiter was employed. As the case studies, the model is applied to the flow around the cylinders and the dam-break flow. Then, the results are compared with the experimental and numerical data of previous studies and good agreements were observed.

Mathatical Analysis for Efficiency of Power Factor Correction System Using IP3003 (타려식 형광등 안정기용 구동 반도체 IP3102의 온도 보상 설계법)

  • Joo, Sung-Juni;Chang, Cheon-Seop
    • Proceedings of the Korean Institute of IIIuminating and Electrical Installation Engineers Conference
    • /
    • 2007.05a
    • /
    • pp.152-156
    • /
    • 2007
  • We introduce the IP3102 which is developed by Interpion Semiconductor co. LTD. for the CFL ballaster. The IP3102 has thermal compensation function. In this paper, we present the temperature compensation design technique and its implementation in the IP3102. The experimental results is also presented in this paper.

  • PDF

Development of 20W LED bulb for miniaturization (소형화를 위한 20W LED 전구 개발)

  • Kim, Jin-Hong;Song, Sang-Bin;Kim, Gi-Hoon;Moon, Il
    • Proceedings of the Korean Institute of IIIuminating and Electrical Installation Engineers Conference
    • /
    • 2007.05a
    • /
    • pp.64-69
    • /
    • 2007
  • 실내조명의 조도 기준을 만족하는 LED Bulb를 개발하기 위하여 LED 개수를 선정하고, 실내 전반 조명에 적합한 배광을 실현하기 위한 렌즈설계를 하였다. 그리고 LED로부터 발산되는 열을 최적화하기 위한 방열설계를 행하여 주위온도 $50^{circ}C$ 이내에서 동작 가능하도록 하였다. 또한 시제품의 외함에 내장되어 질 수 있는 소형의 20[W]급 전원회로를 설계하고, 시제품을 직접 제작하였다. 시제품의 전기적, 광학적 성능은 CFL의 성능과 거의 동일하다.

  • PDF

쯔나미 수치계산에 있어서의 공간격자간격의 선정기준

  • 이호준;금촌문언;수승신부
    • Proceedings of the Korean Society of Coastal and Ocean Engineers Conference
    • /
    • 1998.09a
    • /
    • pp.12-16
    • /
    • 1998
  • 현재 쯔나미의 계산에 있어서 수치계산의 안정성이나, 파형의 재현을 고려하기 위한 기준 등은 제시된 바 있다. 대표적인 예로 CFL 안정조건과 같이 계산의 불안정을 방지하기 위한 기준을 비롯하여 한 파장내에 적어도 20개의 공간격자를 확보하여야 한다는 등의 기준(Shuto,1991)이 그것이다. 또한, 쯔나미의 거동특성 중 하나인 분산현상에 대해서도 Imamura 등(1988)은 수치분산의 영향을 추정하였고, 저차방정식으로부터 고차의 근사해를 구하는 등의 수법을 제안하기도 하였다. (중략)

  • PDF

Solidify Properties of Radioactive Waste using Paraffin Wax (파라핀 왁스를 이용한 방사성 폐기물의 고화 특성)

  • Lee, Han Chul;Chang, Yoon Ho
    • Applied Chemistry for Engineering
    • /
    • v.17 no.4
    • /
    • pp.391-396
    • /
    • 2006
  • When radioactive wastewater was solidified treatment by cement, the drying rate of cement and the volume reduction ratio was decreased because of boric acid component in the wastewater. In order to supplement the demerit, effects of paraffin wax investigated in this study. Paraffin wax has a hydrophobic properties and a low affinity with inorganic materials. When the radioactive wastewater was tested by a small of wax, the compressive strength of solidified waste are decreased Therefore boric acid in radioactive wastewater are first treated by alkali salt and coated by the stearic acid. During the solidification step, The amount of paraffin wax addition get the result that the compressive strength of solidification with cement was the same as that with paraffin wax. The leaching properties of radioactive waste solidified was the same CFL (cumulative fraction leached), PR (penetration rate), effective diffusivity if paraffin wax content in solidified waste was 20% or 25%.

Comparative Analysis for Numerical Modeling of Tidal Current on Geum River Estuary (금강하구 해역에 대한 조류 수치모델링의 비교 해석)

  • Kang, Sung-Jun;Park, Young-Ki
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.11 no.9
    • /
    • pp.3583-3589
    • /
    • 2010
  • The semi-implicit scheme proposed by Backhaus is introduced to solve two-dimensional shallow water equation. This mothod is applied for the numerical model solving surface elevation and velocity field of Geum River estuary. For the verification of the method, numerical solutions by this model are compared with ones by Heap's well known explicit model. Solutions of two models resemble each other. The time-step chosen for the semi-implicit scheme turned out to be 3 to 6 times longer than explicit model depending on the stringent CFL criterion. The computation time could be reduced at least 50%. It was proved that this scheme is easy to handle dry banks which can be seen in Geum River estuary and numerical stability is obtained for long time computation.

A Study on the Application of LED at Ultra-low Temperature (극저온에서 LED 응용에 관한 연구)

  • Ha, Hee-Ju;Kim, Jin-Wook;Kim, Sun-Jae;Kil, Gyung-Suk
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.27 no.9
    • /
    • pp.600-605
    • /
    • 2014
  • The interest in development on luminaires which are available up to $-52^{\circ}C$ is surging as demands in vessels navigating a north pole route increase. A conventional incandescent lamp used in vessels is operated stably at $-52^{\circ}C$, but many countries including Korea have eliminated the use of incandescent lamps gradually because of its low luminous efficacy. In this paper, therefore, to develop the LED luminaires with high-efficiency, long lifetime that enables to substitute for incandescent lamp, it has studied about cryogenic characteristics of LED packages, bulbs, driving circuit and power supply. This experiments were carried out according to standards IEC 60945-8.4.1. Temperature range is from $-60^{\circ}C$ to $25^{\circ}C$, and the light output depending on ambient temperature. It showed that, based on $25^{\circ}C$, light output of a CFL decreased by 80% of CFL at $-20^{\circ}C$ while each increased 12% of LED bulbs and 16~19% of LED packages at $-60^{\circ}C$.

A Three-Dimensional Numerical Model of Hydrodynamic Flow on σ-Coordinate (연직변환좌표(鉛直變換座標)에서 3차원(次元) 유동(流動) 수직모형(數値模型))

  • Jung, Tae Sung;Lee, Kil Seong
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • v.14 no.5
    • /
    • pp.1145-1158
    • /
    • 1994
  • A three-dimensional, finite difference, numerical model with free surface was developed on ${\sigma}$-coordinate. A semi-implicit numerical scheme in time has been adopted for computational efficiency. The scheme is essentially independent of the stringent stability criteria (CFL condition) for explicit schemes of external surface gravity wave. Implicit algorithm was applied for vertical shear stress, Coriolis force and pressure gradient terms. The reliability of the model with vertically variable grid system was checked by the comparison of simulation results with analytic solution of wind-driven currents in a one-dimensional channel. Sensitivity analysis of differencing parameters was carried out by applying the model to the calculation of wind-driven currents in a square lake.