• Title/Summary/Keyword: CC 평가

Search Result 421, Processing Time 0.028 seconds

Analysis of EDCs by Mass Spectrometry and their Removal by Membrane Filtrations (질량분석법에 의한 내분비계 장애물질의 분석과 막 여과에 의한 제거)

  • Kim Tae-Uk;Yeon Kyeong-Ho;Cho Jaeweon;Moon Seung-Hyeon
    • Membrane Journal
    • /
    • v.15 no.4
    • /
    • pp.297-309
    • /
    • 2005
  • As a number of potential endocrine disrupting compounds (EDCs) are released into the environment, recently growing attention has been drawn to them. Therefore sensitive and reliable analytical methods are essential to monitor those compounds. In this study, complementary CC-MS and LC-MS were employed to analyze the endocrine disrupters, and the results of two methods were compared for di(2-ethylhexyl)phthalate (DEHP), benzylbutylphthalate (BBP), pentachlorophenol (PCP), and 4,4'-Isopropylidenediphenol (Bisphenol-A, or BPA). The results indicate that it was possible to lower the detection limits of EDCs by LC-MS. Also, LC-MS enabled to identify the EDCs as almost intact molecules. Furthermore, this study presented a nanofiltration membrane (MWCO 250) and a ultrafiltration membrane (MWCO 1,000) filtration system as methods far removing EDCs from drinking water containing $\gamma$-BHC, p,p'-DDE, BBP, p,p'-DDT, DEHP, PCP, and BPA. Cross-flow type nanofiltrations showed $100\%$ removal of EDCs, and the result implies that MWCO 250 nanofilter was sufficient for treatment of EDCs. The ratio of permeate flux to mass transfer coefficient of nanofiltration, high flux ultrafiltration, and low flux ultrafiltration with ultrapure water were 0.67, 3.4, and 0.44, respectively. It was found that nanofiltration and low flux ultrafiltration were operated at a diffusion dominant condition, and the high flux ultrafiltration was operated at a convection dominant condition. Furthermore, a diffusion dominant process attained reasonable rejection of EDCs. The removal in the ultrafiltration was depending on the molecular weight of an EDC, and the filtration was governed by diffusion-dominant hydrodynamic conditions.

Evaluation of Electrohydraulic Left Ventricular Assist Device through Animal Experiment (동물실험을 통한 전기유압식 좌심실 보조장치의 성능 평가)

  • Choi, J.S.;Chung, C.I.;Choi, W.W.;Park, S.K.;Jo, Y.H.;Om, K.S.;Lee, J.J.;Won, Y.S.;Kim, H.C.;Kim, W.G.;Min, B.G.
    • Proceedings of the KOSOMBE Conference
    • /
    • v.1996 no.05
    • /
    • pp.84-87
    • /
    • 1996
  • We have been developed electrohydraulic left ventricular assist device and done various in vivo evaluation on the device. Through the in vivo experiment conducted from Jan. 23, 1996 to Feb. 8, we could have experience of long-term evaluation fur the first time. The sheep used in this experiment had survived for 16 days. We used new actuator with reduced size and linear motion guide replacing oil box and ball bearings. Also, we used improved blood chamber with reduced size, reduced weight facilitating fixing the chamber to animal's body, and polymer sac having improved folding pattern. Against suction problem, we used absolute pressure limiter only. Motor current for driving this new actuator was not much higher than older one. Effective stroke volume was about 48 cc. Thrombosis was found around top area and peripheral boundary of the sac and valves. There was no sign of damage from suction problem in the atrium observed at autopsy. Main cause of death was presumed to be progressive formation of thrombosis in the cannulae. In this paper, the results of this experiment are documented.

  • PDF

A Selective Effect of Combined Treatment of Electroacupuncture at Zusanli(ST36), Manual Acupuncture, and Pyengwi-san in Function Dyspepsia Patients with Pyloric Valve Disturbance and Hypoactivity of Gastric Vagus Nerve (한방치료가 위 미주신경 활성 저하와 유문부 기능 장애가 병발된 기능 소화불량중 환자에 미치는 선택적 효능)

  • Kim, So-Yeon;Yoon, Sang-Hyub
    • The Journal of Internal Korean Medicine
    • /
    • v.30 no.1
    • /
    • pp.191-199
    • /
    • 2009
  • Objectives : The aim of this study was to evaluate the therapeutic effect of acupuncture and herbal medicine in patients who had hvpoactivity of the gastric vagus nerve and pyloric valve disturbance simultaneously with function dyspepsia by bowel sounds analysis. Methods : Bowel sounds of 10 patients (male 1, female 9) were recorded and their % of bowel sound (%BS) and ratio of dominant frequency (DF) were analyzed before and after treatment. Hypoactivity of the gastric vagus nerve was considered if % BS was <6%. and pyloric valve disturbance was accepted if DF ratio (e.g.. postprandial DF/fasting DF) was <1. Electroacupuncture at Zusanli (ST36, 3Hz, 30 minutes) and manual acupuncture at other meridian points were applied daily for 2 weeks. Herbal medicine, Pyengwi-san. was administered to all patients (100cc, 3 times/day). Results : DF ratio significantly increased from $0.93\pm0.06$ to $1.06\pm0.04$ after treatment for 2 weeks (p=0.005). 9 of 10 patients were improved to DF ratio>1. %BS also increased from $2.97\pm1.17%$ to $4.49\pm4.27%$. not significantly. 3 patients showed a remarkable elevation, and their %BS reached >6% of normal value. Conclusions : Combined effect of electroacupuncture at Zusanli (ST36), manual acupuncture. and Pyengwi-san was shown effective in the improvement of pyloric valve disturbance more than hypoactivity of gastric vagus nerve on patients with functional dyspepsia.

  • PDF

A Study on the Migration Characteristics of Cs-137 in a Packed Column (충전층에서의 세슘-137의 이동특성에 관한 연구)

  • Lee, Jae-Owan;Cho, Won-Jin;Han, Kyung-Won;Park, Hun-Hwee
    • Nuclear Engineering and Technology
    • /
    • v.22 no.1
    • /
    • pp.20-28
    • /
    • 1990
  • In this study the migration experiment using packed column with crushed tuff was conducted as a basic research to develop migration model of radionuclides through geologic media. The main emphasis was put on evaluating the validity of migration models. For this, two models were introduced: one is the model which is based on the assumption of instantaneous equilibrium reaction and the other the model based on kinetic process such as intraparticle diffusion. The coefficient of hydrodynamic dispersion in packed column was determined using iodine as nonsorbing tracer. The hydrodynamic dispersion coefficient, D$_{L}$ was shown to be 0.11$\times$10$^{-2}$ $\textrm{cm}^2$/min under the condition of the column porosity of 0.483 and the average water velocity of 0.915$\times$10$^{-2}$ cm/min. The distribution coefficient, Kd of Cs-137 on crushed tuff was 11.3 cc/g at the concentration of 2$\times$10$^{-6}$ M and the temperature of 2$0^{\circ}C$. The breakthrough curve of Cs-137 through packed column was shown to have an asymmetric curve in which long trailing tail appears at the end part of the curve. The results obtained from the comparison of introduced models with experimental data indicated that the mass transfer model with intraparticle diffusion as rate-controlling step simulated the behaviors of Cs-137 migration more adequately, when compared with the bulk reaction model in which the assumption of instantaneous equilibrium reaction was maded. Consequently, the intraparticle diffusion was found to be an important factor in the migration of Cs-137 through packed column.n.

  • PDF

Effect of Packaging Materials on the Postharvest Quality of Fresh Wild Garlic Leaves during Room Temperature Storage (포장재 종류가 산마늘 상온저장 중 품질에 미치는 영향)

  • Choi, Ji-Weon;Lee, Ji-Hyun;Kim, Chang-Kug;Lee, Jung Soo;Shin, Il Sheob
    • Proceedings of the Plant Resources Society of Korea Conference
    • /
    • 2019.04a
    • /
    • pp.109-109
    • /
    • 2019
  • 2018년 5월 전라북도 남원군에서 재배하여 수확 후 $0^{\circ}C$ 저장고에서 예냉을 마친 산마늘을 사용하였으며 외 포장 상자는 골판지로 구성된 통기공이 없는 골판지상자 1kg용을 사용하였다. 골판지상자와 함께 내부 포장으로 사용하기 위한 내포장 필름은 $20{\mu}m$ 두께의 HDPE으로 된 필름 봉지, 흡습종이는 파라핀왁스 코팅 종이($32{\times}35cm$, 태영산업)를 이용하여 조합 처리하고 국내에서 개발한 기능성 필름2종으로 포장처리는 총 4가지로 (1) PE(관행) (2) PE+흡습지 (3) 기능성필름1($30{\times}58cm$, 기능성물질 1%+40,000OTR, 제조사: 신영산업사) (4) 기능성필름2($30{\times}58cm$, Key fresh, 제조사: 씨앤케이프로팩(주)) 각 처리당 1kg 씩의 산마늘 잎을 포장하였다. 실험은 포장 처리 후 상온상태로 전북 완주군 실험실까지 수송하였으며 실험실 도착 후 상온 실험실에 두고 2일과 6일 후 중량감소율, 색도, 엽록소, 손실률 및 종합선도 등 품질특성 변화를 조사하였고 각 포장방법별 온도와 상대습도 변화를 보기 위하여 산마늘 잎이 포장된 상자 내부 중앙 부분에 디지털온습도기록계(SP-2000-20R)를 고정한 후 측정하였다. 대조구로 사용한 PE필름 단용으로 포장한 산마늘 잎은 상온저장 6일 경과 후 중량 소율이 1.7%, PE필름+신선지 처리는 1.0%, 기능성필름1과 기능성필름2는 거의 중량감소가 없어 1% 미만의 변화를 보였다. 산마늘 잎의 SPAD 값에 의한 엽록소 수치와 색도를 측정한 명도($L^*$)와 Hue angle 값의 변화는 기능성필름1과 기능성필름2가 유사하게 높게 유지되었고 반면에 PE필름은 저장 2일 후 부터 값이 감소하기 시작하여 6일 후 크게 감소하였다. 저장 6일 후 기능성필름1과 기능성필름2가 외관품위에서 높은 평가를 받아 상품성을 유지하고 있었으나 PE필름 처리와 PE필름+흡습지 처리는 상품성을 상실한 상태였다. 이러한 경향은 건전율에 있어서도 유사하였으며 기능성필름1(다공성 나노 물질이 혼입되어 있으며 산소투과율을 $40,000cc/m2{\cdot}day{\cdot}atm$으로 조성한 필름)이 상온저장 6일 후 상품성을 유지하는 건전율이 83%로 가장 높았다.

  • PDF

Effects of Dangui-jakyak-san on Common Carotid Artery Elasticity in Healthy Subjects ; A Randomized controlled crossover study (당귀작약산이 정상인의 총경동맥 탄력도에 미치는 영향 : 무작위대조군 교차시험)

  • Kim, Soohyun;Seo, Yuna;Bae, In-hu;Cho, Ki-Ho;Moon, Sang-Kwan;Jung, Woo-Sang;Kwon, Seungwon;Jin, Chul
    • The Journal of the Society of Stroke on Korean Medicine
    • /
    • v.21 no.1
    • /
    • pp.21-32
    • /
    • 2020
  • ■ Objectives 당귀작약산 단회 복용으로 정상인의 총경동맥 탄력도에 미치는 영향을 평가하고자 하였다. ■ Methods 본 연구는 정상인 남성을 대상으로 한 전향적 무작위 대조군 교차시험연구다. 모든 대상자들은 임의로 당귀작약산 복용군과 비복용군인 대조군으로 나누어졌다. 1주일 간격으로 총 2회 방문하며, 첫 번째 방문 시에 당귀작약산 복용군은 당귀작약산 1포(2.5g)과 물을 제공받고, 대조군은 물만 제공받아 복용하였다. 두 번째 방문 시 첫 번째 방문과 반대로 당귀작약산을 복용했던 복용군은 물만 제공받고, 물만 복용했던 피험자들은 당귀작약산 1포와 물을 제공받았다. 물은 100 cc로 매번 동일하게 제공되었다. 모든 대상자들은 복용 직전과 복용 2시간, 4시간 후에 총경동맥 탄력도, 혈압, 총경동맥 내막-중막 두께와 맥박수를 측정하였다. ■ Results 총 20명의 정상인 남성이 모집되었으며, 시간에 따라 당귀작약산 복용 후의 총경동맥 탄력도가 대조군에 비하여 유의하게 상승한 것이 확인되었다. 내막-중막 두께, 혈압 및 맥압, 맥박은 유의한 변화가 나타나지 않았다. ■ Conclusion 당귀작약산의 단회 복용으로 총경동맥 탄력도가 즉시 개선되는 것을 확인하였고, 이로써 당귀작약산이 동맥 경직도 완화 및 탄성의 개선에 영향을 미친다는 것을 알 수 있었다.

  • PDF

Study on the Usefulness about Molecular Breast Imaging In Dense Breast (치밀형 유방에서 Molecular Breast Imaging 검사의 유용성에 관한 고찰)

  • Baek, Song Ee;Kang, Chun Goo;Lee, Han Wool;Park, Min Soo;Choi, Young Sook;Kim, Jae Sam
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.20 no.1
    • /
    • pp.42-46
    • /
    • 2016
  • Purpose Mammography is the most widely used scan for the early diagnosis since it is possible to observe the anatomy of the breast. however, The sensitivity is markedly reduced in high-risk patients with dense breast. Molecular Breast Imaging (MBI) sacn is possible to get the high resolution functional imaging, and This new neclear medicine technique get the more improved diagnostic information through It is useful for confirmation of tumor's location in dense breast. The purpose of this study is to evaluate the usefulness of MBI for tumor diagnosis in patients with dense breast. Materials and Methods We investigated 10 patients female breast cancer with dense breast type who had visited the hospital from September 1st to Octorber 10th, 2015. The patients underwent both MBI and Mammography. MBI (Discovery 750B; General Electric Healthcare, USA) scan was 99mTc-MIBI injected with 20 mCi on the opposite side of the arm with the lesions, after 20 minutes, gained bilateral breast CC (CranioCaudal), MLO (Medio Lateral Oblique) View. Mammography was also conducted in the same posture. MBI and Mammography images were compared to evaluate the sensitivity and specificity of each case utilizing both image and two images in blind tests. Results The results of the blind test for breast cancer showed that the sensitivity of Mammography, MBI scan was 63%, 89%, respectively, and that their specificity was 38%, 87%, respectively. Using both the Mammography and MBI scan was Sensitivity 92%, specificity 90%. Conclusion This research has found that, The tumor of dense tissue that can not easily distinguishable in Mammography is possible to more accurate diagnosis since It is easy to visually evaluation. But MBI sacn has difficulty imaging microcalcificatons, If used in conjunction with mammography it is thought to give provide more diagnostic information.

  • PDF

Quality Assurance of Volumetric Modulated Arc Therapy Using the Dynalog Files (다이나로그 파일을 이용한 부피세기조절회전치료의 정도관리)

  • Kang, Dong-Jin;Jung, Jae-Yong;Shin, Young-Joo;Min, Jung-Whan;Kim, Yon-Lae;Yang, Hyung-jin
    • Journal of radiological science and technology
    • /
    • v.39 no.4
    • /
    • pp.577-585
    • /
    • 2016
  • The purpose of this study is to evaluate the accuracy of beam delivery QA software using the MLC dynalog file, about the VMAT plan with AAPM TG-119 protocol. The Clinac iX with a built-in 120 MLC was used to acquire the MLC dynalog file be imported in MobiusFx(MFX). To establish VMAT plan, Oncentra RTP system was used target and organ structures were contoured in Im'RT phantom. For evaluation of dose distribution was evaluated by using gamma index, and the point dose was evaluated by using the CC13 ion chamber in Im'RT phantom. For the evaluation of point dose, the mean of relative error between measured and calculated value was $1.41{\pm}0.92%$(Target) and $0.89{\pm}0.86%$(OAR), the confidence limit were 3.21(96.79%, Target) and 2.58(97.42%, OAR). For the evaluation of dose distribution, in case of $Delta^{4PT}$, the average percentage of passing rate were $99.78{\pm}0.2%$(3%/3 mm), $96.86{\pm}1.76%$(2%/2 mm). In case of MFX, the average percentage of passing rate were $99.90{\pm}0.14%$(3%/3 mm), $97.98{\pm}1.97%$(2%/2 mm), the confidence limits(CL) were in case of $Delta^{4PT}$ 0.62(99.38%, 3%/3 mm), 6.6(93.4%, 2%/2 mm), in case of MFX, 0.38(99.62%, 3%/3 mm), 5.88(94.12%, 2%/2 mm). In this study, we performed VMAT QA method using dynamic MLC log file compare to binary diode array chamber. All analyzed results were satisfied with acceptance criteria based on TG-119 protocol.

Usefuless of Multi-functional Gastroduodenal Coil Catheter with Phantom (팬텀을 이용한 다기능 위.십이지장관 코일 카테타의 유용성 평가)

  • Lim, Jin-Oh;Kim, Tae-Hyung;Jung, Yang-Hwa;Choi, Won-Chan;Shin, Ji-Hoon;Song, Ho-Young
    • Journal of radiological science and technology
    • /
    • v.26 no.4
    • /
    • pp.21-26
    • /
    • 2003
  • To evaluate the newly designed gastroduodenal coil catheter:in-vitro test. The coil catheter that we made in our laboratory was 150 cm. The coil that is made of stainless steel wire was composed 1.3 mm inner diameter and this coil spring was covered with heat-shrinkable polyethylene tube. To measure the length under fluorocopy, 8 radiopaque marks were attached at 5 cm, 10 cm, 11 cm, 12 cm, 13 cm, 14 cm, 15 cm, 20 cm apart from distal end of the catheter and 6, 2, 1 pores were made at 7 cm, 13 cm, 19 cm apart from the distal end. Radio-opacity and the amount of injected contrast was investigated in formerly used 5 Fr. vessel catheter, which is possible in measuring length, and newly designed coil catheter. Film density was tested for radio-opacity with autodensitometer. For measuring the volume of injected salin, the catheter was located in the acryl box(26 cm, 3 cm, 16 cm) that divided into 4 chambers. After injection 50 cc of contrast with autoinjector, the contrast's quantity in each chamber was measured with and without over the guide wire. Radio-opacity was 0.51 in 5 Fr. vessel catheter, 0.31 in newly made catheter. The amount of injected contrast was measured. In case of 5 Fr. vessel catheter, the amount was 99.5% from the distal part, there was no difference between with and without the guide wire. Otherwise, using a coil catheter, the pacentage the ejected saline was 1.17%, 18.8%, 41.8%, 38.2% from the distal part with the guide wire, 19.5%, 32.6%, 27.7%, 20.3% without the guide wire. Compare with formerly established catheter, this new coil catheter is easy to measure the length thanks to easy confirming under fluoroscopy and excellent in injecting contrast. Therefore, newly designed gastrointestinal catheter seems to be useful in gastrointestinal intervention procedure.

  • PDF

Evaluating the usefulness of BinkieRTTM (oral positioning stent) for Head and Neck Radiotherapy (두경부암 환자 방사선 치료 시 BinkieRTTM(구강용 고정장치)에 대한 유용성 평가)

  • GyeongJin Lee;SangJun Son;GyeongDal Lim;ChanYong Kim;JeHee Lee
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.34
    • /
    • pp.21-30
    • /
    • 2022
  • Purpose: The purpose of this study is to evaluate the effectiveness of oral positioning stent, the BinkieRTTM in radiation treatment for head and neck cancer patients in terms of tongue positions reproducibility, tongue doses and material properties. Materials and Methods: 24 cases using BinkieRTTM during radiation treatments were enrolled. The tongue was contoured on planning CT and CBCT images taken every 3 days during treatment, and then the DSC and center of tongue shift values were analyzed to evaluate the reproducibility of the tongue. The tongue dose was compared in terms of dose distribution when using BinkieRTTM and different type of oral stents (mouthpiece, paraffin wax). Randomly selected respective 10 patients were measured tongue doses of initial treatment plan for nasal cavity and unilateral parotid cancer. Finally, In terms of material evaluation, HU and relative electron density were identified in RTPS. Results: As a result of DSC analysis, it was 0.8 ± 0.07, skewness -0.8, kurtosis 0.61, and 95% CI was 0.79~0.82. To analyze the deviation of the central tongue shift during the treatment period, a 95% confidence interval for shift in the LR, SI, and AP directions were indicated, and a one-sample t-test for 0, which is an ideal value in the deviation(n=144). As a result of the t-test, the mean and SD in the LR and SI directions were 0.01 ± 0.14 cm (p→.05), 0.03 ± 0.25 cm (p→.05), and -0.08 ± 0.25 cm (p ←.05) in the AP direction. In the case of unilateral parotid cancer patients, the Dmean to the tongue of patients using BinkieRTTM was 16.92% ± 3.58% compared to the prescribed dose, and 23.99% ± 10.86% of patients with Paraffin Wax, indicating that the tongue dose was relatively lower when using BinkieRTTM (p←.05). On the other hand, among nasal cavity cancer patients, the Dmean of tongue dose for patients who used BinkieRTTM was 4.4% ± 5.6%, and for those who used mouthpiece, 5.9% ± 6.8%, but it was not statistically significant (p→.05). The relative electron density of Paraffin Wax, BinkieRTTM and Putty is 0.94, 0.99, 1.26 and the mass density is 0.95, 0.99 and 1.32 (g/cc), Transmission Factor is 0.99, 0.98, 0.96 respectively. Conclusion: The result of the tongue DSC analysis over the treatment period was about 0.8 and Deviation of the center of tongue shifts were within 0.2 cm, the reproducibility was more likely excellent. In the case of unilateral head and neck cancer patients, it was found that the use of BinkieRTTM rather than Paraffin Wax or Putty can reduce the unnecessary dose irradiated to the tongue. This study might be useful to understand of BinkieRTTM's properties and advantages. And also it could be another considered option as oral stent to keep the reproducibility of tongue and reducing dose during head and neck radiation treatments.