• 제목/요약/키워드: CAM(Computer-Aided Manufacturing)

검색결과 237건 처리시간 0.024초

총의치 제작에 적용 가능한 디지털 기술과 임상적 고찰 (Application and consideration of digital technology for removable complete denture)

  • 이정진;송광엽;박주미
    • 대한치과의사협회지
    • /
    • 제57권9호
    • /
    • pp.534-543
    • /
    • 2019
  • Digital technology has changed various aspects of the clinical dentistry. The intraoral scanner and Computer-aided design / Computer-aided manufacturing (CAD-CAM) technology are widely used in fabricating fixed prostheses and in implant surgery. These technologies greatly improved the efficiency of clinical and laboratory procedures. With all newly introduced software, devices, and clinical studies, digital technology has been actively applied in removable prostheses. It is now possible to fabricate the removable prostheses more quickly and easily through subtractive and additive manufacturing. Various clinical and laboratory protocols were introduced by many manufacturers. The purpose of this review is to summarize the literature on digital technology for fabricating complete denture with current status and future perspectives.

  • PDF

Advancements in craniofacial prosthesis fabrication: A narrative review of holistic treatment

  • Jazayeri, Hossein E.;Kang, Steve;Masri, Radi M.;Kuhn, Lauren;Fahimipour, Farahnaz;Vanevenhoven, Rabecca;Thompson, Geoffrey;Gheisarifar, Maryam;Tahriri, Mohammadreza;Tayebi, Lobat
    • The Journal of Advanced Prosthodontics
    • /
    • 제10권6호
    • /
    • pp.430-439
    • /
    • 2018
  • The treatment of craniofacial anomalies has been challenging as a result of technological shortcomings that could not provide a consistent protocol to perfectly restore patient-specific anatomy. In the past, wax-up and impression-based maneuvers were implemented to achieve this clinical end. However, with the advent of computer-aided design and computer-aided manufacturing (CAD/CAM) technology, a rapid and cost-effective workflow in prosthetic rehabilitation has taken the place of the outdated procedures. Because the use of implants is so profound in different facets of restorative dentistry, their placement for craniofacial prosthesis retention has also been widely popular and advantageous in a variety of clinical settings. This review aims to effectively describe the well-rounded and interdisciplinary practice of craniofacial prosthesis fabrication and retention by outlining fabrication, osseointegrated implant placement for prosthesis retention, a myriad of clinical examples in the craniofacial complex, and a glimpse of the future of bioengineering principles to restore bioactivity and physiology to the previously defected tissue.

Influence of different universal adhesives on the repair performance of hybrid CAD-CAM materials

  • Demirel, Gulbike;Baltacioglu, Ismail Hakki
    • Restorative Dentistry and Endodontics
    • /
    • 제44권3호
    • /
    • pp.23.1-23.9
    • /
    • 2019
  • Objectives: The aim of this study was to investigate the microshear bond strength (${\mu}SBS$) of different universal adhesive systems applied to hybrid computer-aided design/computer-aided manufacturing (CAD-CAM) restorative materials repaired with a composite resin. Materials and Methods: Four types of CAD-CAM hybrid block materials-Lava Ultimate (LA), Vita Enamic (VE), CeraSmart (CS), and Shofu Block HC (SH)-were used in this study, in combination with the following four adhesive protocols: 1) control: porcelain primer + total etch adhesive (CO), 2) Single Bond Universal (SB), 3) All Bond Universal (AB), and 4) Clearfil Universal Bond (CU). The ${\mu}SBS$ of the composite resin (Clearfil Majesty Esthetic) was measured and the data were analyzed using two-way analysis of variance and the Tukey test, with the level of significance set at p < 0.05. Results: The CAD-CAM block type and block-adhesive combination had significant effects on the bond strength values (p < 0.05). Significant differences were found between the following pairs of groups: VE/CO and VE/AB, CS/CO and CS/AB, VE/CU and CS/CU, and VE/AB and CS/AB (p < 0.05). Conclusions: The ${\mu}SBS$ values were affected by hybrid block type. All tested universal adhesive treatments can be used as an alternative to the control treatment for repair, except the AB system on VE blocks (the VE/AB group). The ${\mu}SBS$ values showed variation across different adhesive treatments on different hybrid CAD-CAM block types.

디지털 장비의 중첩기능을 이용하여 단일체 수복물의 교합조정을 최소화한 증례 (Superimposition: a simple method to minimize occlusal adjustment of monolithic restoration)

  • 최창훈;김선재
    • 대한치과보철학회지
    • /
    • 제54권3호
    • /
    • pp.253-258
    • /
    • 2016
  • 최근 CAD-CAM과 지르코니아를 이용한 보철물의 제작이 증가하고 있으며 구강스캐너의 발달로 임상 및 기공과정이 단순화되고 있다. 균열치 혹은 치아의 일부가 파절된 경우, 구강스캐너를 사용하여 치아 삭제 전에 치아의 형태를 미리 스캔하고, 추후 수복물 제작 시 중첩을 통해 단일체 지르코니아 전장관을 제작하면 원래 환자의 자연치 형태와 교합을 재현할 수 있다. 본 증례에서는 균열 및 파절된 치아에서 구강 스캐너, CAD-CAM 및 단일체 지르코니아 전장관을 사용하여 삭제 전 치아의 형태와 교합을 재현한 수복물을 제작하였으며, 교합조정을 최소화할 수 있었다. 또한 임상적으로 기능적이고 심미적인 결과를 얻을 수 있었다.

Trueness and precision of scanning abutment impressions and stone models according to dental CAD/CAM evaluation standards

  • Jeon, Jin-Hun;Hwang, Seong-Sig;Kim, Ji-Hwan;Kim, Woong-Chul
    • The Journal of Advanced Prosthodontics
    • /
    • 제10권5호
    • /
    • pp.335-339
    • /
    • 2018
  • PURPOSE. The purpose of the present study was to compare scanning trueness and precision between an abutment impression and a stone model according to dental computer-aided design/computer-aided manufacturing (CAD/CAM) evaluation standards. MATERIALS AND METHODS. To evaluate trueness, the abutment impression and stone model were scanned to obtain the first 3-dimensional (3-D) stereolithography (STL) file. Next, the abutment impression or stone model was removed from the scanner and re-fixed on the table; scanning was then repeated so that 11 files were obtained for each scan type. To evaluate precision, the abutment impression or stone model was scanned to obtain the first 3-D STL file. Without moving it, scanning was performed 10 more times, so that 11 files were obtained for each scan type. By superimposing the first scanned STL file onto the other STL files one by one, 10 color-difference maps and reports were obtained; i.e., 10 experimental scans per type. The independent t-test was used to compare root mean square (RMS) data between the groups (${\alpha}=.05$). RESULTS. The $RMS{\pm}SD$ values of scanning trueness of the abutment impression and stone model were $22.4{\pm}4.4$ and $17.4{\pm}3.5{\mu}m$, respectively (P<.012). The $RMS{\pm}SD$ values of scanning precision of the abutment impression and stone model were $16.4{\pm}2.9$ and $14.6{\pm}1.6{\mu}m$, respectively (P=.108). CONCLUSION. There was a significant difference in scanning trueness between the abutment impression and stone model, as evaluated according to dental CAD/CAM standards. However, all scans showed high trueness and precision.

Physical characteristics of ceramic/glass-polymer based CAD/CAM materials: Effect of finishing and polishing techniques

  • Ekici, Mugem Asli;Egilmez, Ferhan;Cekic-Nagas, Isil;Ergun, Gulfem
    • The Journal of Advanced Prosthodontics
    • /
    • 제11권2호
    • /
    • pp.128-137
    • /
    • 2019
  • PURPOSE. The aim of this study was to compare the effect of different finishing and polishing techniques on water absorption, water solubility, and microhardness of ceramic or glass-polymer based computer-aided design and computer-aided manufacturing (CAD/CAM) materials following thermocycling. MATERIALS AND METHODS. 150 disc-shaped specimens were prepared from three different hybrid materials and divided into five subgroups according to the applied surface polishing techniques. All specimens were subjected up to #4000 grit SiC paper grinding. No additional polishing has been done to the control group (Group I). Other polishing procedures were as follows: Group II: two-stage diamond impregnated polishing discs; Group III: yellow colored rubber based silicone discs; Group IV: diamond polishing paste; and Group V: Aluminum oxide polishing discs. Subsequently, 5000-cycles of thermocycling were applied. The analyses were conducted after 24 hours, 7 days, and 30 days of water immersion. Water absorption and water solubility results were analyzed by two-way ANOVA and Tukey post-hoc tests. Besides, microhardness data were compared by Kruskal-Wallis and MannWhitney U tests (P<.05). RESULTS. Surface polishing procedures had significant effects on water absorption and solubility and surface microhardness of resin ceramics (P<.05). Group IV exhibited the lowest water absorption and the highest microhardness values (P<.05). Immersion periods had no effect on the microhardness of hybrid ceramic materials (P>.05). CONCLUSION. Surface finishing and polishing procedures might negatively affect physical properties of hybrid ceramic materials. Nevertheless, immersion periods do not affect the microhardness of the materials. Final polishing by using diamond polishing paste can be recommended for all CAD/CAM materials.

CAD/CAM으로 제작된 지르코니아 코어의 지대치 형태에 따른 변연 및 내면 적합도에 관한 연구 (Marginal and internal fit according to the shape of the abutment of a zirconia core manufactured by computer-aided design/computer-aided manufacturing)

  • 김지수;류재경
    • 대한치위생과학회지
    • /
    • 제5권1호
    • /
    • pp.13-19
    • /
    • 2022
  • Background: In this study, zirconia copings were fabricated by setting clinically acceptable inner values for prostheses using computer-aided design/computer-aided manufacturing (CAD/CAM). The processed copings were evaluated for the marginal and internal fit of each abutment shape with a CAD program using the silicone replica technique. Methods A total of 20 copings was produced by selecting models commonly used in clinical practice. After injecting the sample, the minimum thickness, internal adhesion interval, and distance to the margin line were set to 0.5, 0.05, and 1.00 mm using a dental CAD program, respectively. It was measured using a 2D section function in a three-way program of the silicon replication technology. Although the positions and number of measurements of the anterior and posterior regions differed, nine parts of each pre-tube were designated and measured by referring to a previous study to compare the two samples. Results As a result, the average margin of the mesial, distal, and buccal (labial) surfaces was 59.90 ㎛ in the anterior region and 60.40 ㎛ in the posterior region. The mean axial wall margin was 67.25 ㎛ in the anterior region and 69.25 ㎛ in the posterior region. In occlusion, the anterior teeth (77.70 ㎛), posterior teeth (77.60 ㎛), and both anterior and posterior regions were within the clinically acceptable range. Conclusion The edge and inner fit of zirconia coping manufactured using the CAD/CAM system showed clinically applicable results. To reduce errors and increase accuracy, materials and machine errors that affect the manufacture of prosthetics should be investigated. Based on our results, the completeness of prosthetics could increase if the inner value and characteristics of the material are adjusted when applied in clinical practice.

LSC를 이용한 스캔데이터 변환 및 3차원 모델 생성에 관한 연구 (A Study on the 3D Modelling and Transference of Scaning Data using LSC Method)

  • 김민주;이승수;박정보;김순경;전언찬
    • 한국공작기계학회:학술대회논문집
    • /
    • 한국공작기계학회 2001년도 춘계학술대회 논문집(한국공작기계학회)
    • /
    • pp.387-392
    • /
    • 2001
  • This paper is to model a 30-shape product applying mathematically the data acquired from a 3D scanner and using an Automatic Design Program. The research studied in th reverse engineering up to now has been developed continuously and surprisingly. However, forming 3D-shape solid models in CAE and CAM, based on the research, the study leaves much to be desired. Especially, analyses and studies reverse-designing automatically using measured data after manufacturing. Consequently, we are going to acquire geometric data using an 3D scanner in this study with which we will open a new field of reverse engineering by a program which can design a 3D-shape solid model in a CAD-based program automatically.

  • PDF

CAM에서의 사례의존규칙을 이용한 실시간 일정계획 (Real Time Scheduling for Computer-Aided Manufacturing ( CAM ) Systems with Instance-Based Rules)

  • 이종태
    • 대한산업공학회지
    • /
    • 제17권2호
    • /
    • pp.63-74
    • /
    • 1991
  • An expert scheduling system on real time basis for computer-aided manufacturing systems has been developed. In developing expert scheduling system, the most time-consuming job is to obtain rules from expert schedulers. An efficient process of obtaining rules directly form the schedules produced by expert schedulers is proposed. By the process, a set of complete and minimal set of rules is obtained. During a real time scheduling, when given information on possible values of elements, the rules produce possible values of decision elements, where logical explanations of the result may be offered in terms of chaining rules. The learning and scheduling processes have been simulated with an automated manufacturing line engaged in the production of circuit boards.

  • PDF