• Title/Summary/Keyword: C.C.M system

Search Result 6,087, Processing Time 0.036 seconds

A Study on the 43$0^{\circ}C$ Degradation Behavior of Cast Stainless Steel(CF8M) (III) - Evaluation of Elastic-Plastic Fracture Toughness - (주조 스테인리스강 CF8M의 43$0^{\circ}C$ 열화거동에 관한 연구 (III) - 탄소성 파괴인성 평가 -)

  • Gwon, Jae-Do;In, Jae-Hyeon;Park, Jung-Cheol;Choe, Seong-Jong;Park, Yun-Won
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.24 no.10 s.181
    • /
    • pp.2405-2412
    • /
    • 2000
  • A cast stainless steel may experience an embrittlement when it is exposed to approximately 30$0^{\circ}C$ for long period. In the present investigation, The three classes of the thermally aged CF8M specimie n are prepared using an artificially accelerated aging method. Namely, after the specimen are held for 300, 1800 and 3600hrs. at 43$0^{\circ}C$ respectively, the specimens are quenched in water to room temperature. Load versus load line displacement curves and J-R curves are obtained using the unloading compliance method. $J_{IC}$ values are obtained following ASTM E 813-87 and ASTM E 813-81 methods. In addition to these methods, JIC values are obtained using SZW(stretch zone width) method described in JSME S 001-1981. The results of the unloading compliance method are $J_Q$=485.7 kJ/m$^2$ for virgin material, $J_{IC}$ of the degraded materials associated with 300, 1800 and 3600hrs are obtained 369.25 kJ/m$^2$, 311.02 kJ/m$^2$, 276.7 kJ/m$^2$, respectively. The results of SZW method are similar to those of the unloading compliance method. Through the elastic-plastic fracture toughness test, it is found that the value of $J_{IC}$ is decreased with increasing of the aging time. The results obtained through the investigation can provide reference data for a leak before break(LBB) of reactor coolant system of nuclear power plants.

The Effect of Construction Methods on Geothermal Exchange Rates of Cast-in-place Energy Piles (현장타설말뚝형 에너지 파일의 시공형태별 지중 열교환량에 관한 연구)

  • Park, Yong-Boo;Nam, Yu-Jin;Sim, Young-Jong;Sohn, Jeong-Rak
    • Land and Housing Review
    • /
    • v.3 no.2
    • /
    • pp.169-175
    • /
    • 2012
  • In recent, there are many studies associated with energy piles to save initial construction cost for ground source heat pump system. In this study, to evaluate geothermal exchange rates two types (a connection type and a slinky type) of cast-in-place energy piles (PRD, 4.5m in depth, 1,200 mm in diameter) were constructed for the tests and their efficiencies were compared with numerical analysis results. As a result, starting with operation, geothermal exchange rate gradually decreases due to exchange of lower ground temperature. In the case of connection type, temperature difference is $0.37^{\circ}C$ in heating mode and $0.34^{\circ}C$, in cooling mode, respectively. In addition, in case of a connection type, geothermal exchange rate in heating mode is 2,314W/m and in cooling mode, 252.2W/m whose value is 9% higher than in heating mode. In the case of slinky type, the average geothermal exchange rate in heating mode is 168.0W/m, which is about 27% lower than that of connection type.

Flood stage analysis considering the uncertainty of roughness coefficients and discharge for Cheongmicheon watershed (조도계수와 유량의 불확실성을 고려한 청미천 유역의 홍수위 해석)

  • Shin, Sat-Byeol;Park, Jihoon;Song, Jung-Hun;Kang, Moon Seong
    • Journal of Korea Water Resources Association
    • /
    • v.50 no.10
    • /
    • pp.661-671
    • /
    • 2017
  • The objective of this study was to analyze the flood stage considering the uncertainty caused by the river roughness coefficients and discharge. The methodology of this study involved the GLUE (Generalized Likelihood Uncertainty Estimation) to quantify the uncertainty bounds applying three different storm events. The uncertainty range of the roughness was 0.025~0.040. In case of discharge, the uncertainty stemmed from parameters in stage-discharge rating curve, if h represents stage for discharge Q, which can be written as $Q=A(h-B)^C$. Parameters in rating curve (A, B and C) were estimated by non-linear regression model and assumed by t distribution. The range of parameters in rating curve was 5.138~18.442 for A, -0.524~0.104 for B and 2.427~2.924 for C. By sampling 10,000 parameter sets, Monte Carlo simulations were performed. The simulated stage value was represented by 95% confidence interval. In storm event 1~3, the average bound was 0.39 m, 0.83 m and 0.96 m, respectively. The peak bound was 0.52 m, 1.36 m and 1.75 m, respectively. The recurrence year of each storm event applying the frequency analysis was 1-year, 10-year and 25-year, respectively.

THE EXTENSION OF THREE-WAY BALANCED MULTI-LEVEL ROTATION SAMPLING DESIGNS

  • Kim, K.W.;Park, Y.S.;Lee, D.H.
    • Journal of the Korean Statistical Society
    • /
    • v.35 no.4
    • /
    • pp.343-353
    • /
    • 2006
  • The two-way balanced one-level rotation design, $r_1^m-r_2^{m-1}$, and the three-way balanced multi-level rotation design, $r_1^m(\iota)-r_1^{m-1}$, were discussed (Park et al., 2001, 2003). Although these rotation designs enjoy balancing properties, they have a restriction of $r_2=c{\cdot}r_1$ (c should be a integer value) which interferes with applying these designs freely to various situations. To overcome this difficulty, we extend the $r_1^m(\iota)-r_1^{m-1}$ design to new one under the most general rotation system. The new multi-level rotation design also satisfies tree-way balancing which is done on interview time, rotation group and recall time. We present the rule and rotation algorithm which guarantee the three-way balancing. In particular, we specify the necessary condition for the extended three-way balanced multi-level rotation sampling design.

-A Study on the Thermal Performance of T.W System with Various Wall Surface Finishes- (집열면의 마감상태에 따른 축열벽 시스템의 열성능 변화에 관한 연구)

  • 송국섭;이언구;이명호
    • Proceedings of the Korea Society for Energy Engineering kosee Conference
    • /
    • 1993.05a
    • /
    • pp.64-69
    • /
    • 1993
  • The solar energy collection of a passive solar system depends on the finish of collecting surfaces. In this study, the test models of T.W system with different wall surface finishes were constructed, and the temperature distribution through the models was monitored. At the same time, a computer program based on F.D.M was developed in order to simulate various surface finishes. The difference of indoor temperature between the model with white color finish ($\alpha$=0.25) and the one with black color finish ($\alpha$=0.95) was about 1$0^{\circ}C$. For the wall with selective coating, the indoor temperature was 4-5$^{\circ}C$ higher than that of red brick wall, and 3-4$^{\circ}C$ higher than that of wall with black paint.

  • PDF

Nonlinear Regression Analysis of Acid-Base Titration System (산-염기 적정 시스템의 비선형 회귀분석에 관한 고찰)

  • Park, Chung-Oh;Hong, Jae-Jin
    • Korean Journal of Clinical Laboratory Science
    • /
    • v.40 no.1
    • /
    • pp.18-25
    • /
    • 2008
  • In classical titrimetric analyses, the major concern is the concentration of titrant, usually the aqueous solution of hydrochloric acid or sodium hydroxide, that could be changed as time goes by and it is accompanied with the inaccuracy of the resulting data. And the statistical approach, the nonlinear regression analysis, which is a well-known statistical method, was introduced to determine the accurate concentration of the titrant and the exact value of parameters, $K_a$, r, $C_a$, $C_b$, for 0.01 M aqueous solutions of analytes, sodium pyruvate, sodium acetate, sodium bicarbonate, ammonium hydroxide, ammonium chloride and acetic acid at $25^{\circ}C$. We used Gauss-Newton method for the linearlization of the nonlinear titration system and the two-parameter fitting showed appreciable convergent data for the parameters of the analytes set with the various range of $K_a$ value.

  • PDF

A GUI Module Generator for Integrated Esterel/C++ simulation (통합된 Esterel/C++시뮬레이션을 위한 GUI 코드자동생성)

  • Liu, Sujuan;Rim, Kee-Wook;Lee, Jaeho;Han, Taisook
    • Annual Conference of KIPS
    • /
    • 2007.11a
    • /
    • pp.779-781
    • /
    • 2007
  • Nowadays, as the increasing functionality and scales of embedded systems, system design grows more complex than before. So verification and simulation of systems become an important facet in hardware-software co-design issues. But it is almost impossible to simulate an embedded system without real hardware implementation or environment communication, especially for control-dominated reactive systems. Therefore, in this paper, we will introduce a GUI environment module generator for integrated Esterel\C++ simulation. By generating the GUI modeling environment, we can simulate and verify the whole embedded system conveniently.

A Study on the Mask Fabrication Process for X-ray Lithography (X-선 노광용 마스크 제작공정에 관한 연구)

  • 박창모;우상균;이승윤;안진호
    • Journal of the Microelectronics and Packaging Society
    • /
    • v.7 no.2
    • /
    • pp.1-6
    • /
    • 2000
  • X-ray lithography mask with SiC membrane and Ta absorber patterns has been fabricated using ECR plasma CVD, d.c. magnetron sputtering, and ECR plasma etching. The stress of stoichiometric SiC film was adjusted by rapid thermal annealing under $N_2$, ambient. Adjusting the working pressure during sputtering process resulted in a near-zero residual stress, reasonable density, and smooth surface morphology of Ta film. Cl-based plasma showed a good etching characteristics of Ta, and two-step etching process was implemented to suppress microloading effect fur sub-quarter $\mu\textrm{m}$ patterning.

  • PDF

19th Century's Typical System of Commoner's House in Southwestern Island Area of Korea (19세기 한국 남서해(南西海) 도서지역(島嶼地域) 민가(民家)의 유형적 체계)

  • Kim, Ji-Min
    • Journal of architectural history
    • /
    • v.1 no.1 s.1
    • /
    • pp.49-67
    • /
    • 1992
  • This study is an architectural investigation paper which has been investigated for 5 years from 1986 about commoner's traditional houses and village in southwestern island area of Korea. Man has lived in this area form the prehistoric age. But from 13C to 14C and in 16C most of people had left this islands by external invasion (Japan) and from 17C many people have lived in real earnest. This area did not have cultural interchange easily than inland area because of geographical conditions, Therefore, so far, many traditional factors have been handed down and especially, a good many commoner's traditional houses exist. The time of builging of these houses is mainly 19C and building shape of those days remains nearly as it is. About 450 houses have been investigated for 5 years. The composition of the houses is composed of Anchae (a centeral house), Sarangchae (an attached house of anchae) and Chukganchae (It has rest room and stores barnyard manure). Somtimes, Sarangchae was ommitted according to the circumstance of the house. Generally, the form of arrangement of house is divided into two shapes; One is 'ㅡ'shape which has only Anchae and the other is 'ㄱ' shape which has Anchae and Sarangchae. In the scale of the house, Anchae averages $41m^2$ and Sarangchae averages $27m^2$.

  • PDF

Effects of ${ZnAl_2}{O_4}$ on the Microstructure and Electrical Properties of ZnO Varistor (ZnO 바리스터의 미세구조와 전기적특성에 미치는 ${ZnAl_2}{O_4}$의 영향)

  • 손세구;김경남;한상목
    • Journal of the Korean Ceramic Society
    • /
    • v.37 no.4
    • /
    • pp.314-319
    • /
    • 2000
  • Microstructueral development and electrical properties in ZnO-Bi2O3-ZnAl2O4 system were investigated with ZnAl2O4 content(0.1~1.0 mol%). The shrinakge of specimens started around $700^{\circ}C$ and finished at 110$0^{\circ}C$, reaching a maximum shrinkage rate at 80$0^{\circ}C$. The shrinkage rate is strongly related to the fromation of a Bi-rich liquid. The increase of the ZnAl2O4 content inhibited the grain growth of ZnO. Most of ZnAl2O4 particles located at the grain boundaries were about 2~3${\mu}{\textrm}{m}$. ZnO grain size changed little up to 110$0^{\circ}C$, but increased markedly above 115$0^{\circ}C$, especially at lower ZnAl2O4 content. Drastic decreasing in breakdown voltage(Vb) with increasing temperature is expected to be dependent on the ZnO grain size and the distribution of the largest grains between the electrode. The nonlinear I-V characteristic was significantly influenced by the ZnAl2O4 content, which exhibited a maximum value at about 15${\mu}{\textrm}{m}$ of ZnO grain size.

  • PDF